943 resultados para loop closure
Resumo:
The safety of percutaneous transapical mitral paravalvular leak (PVL) closure could potentially be enhanced by device closure of the ventricular access site. Percutaneous transapical PVL closure was performed. The 9F delivery sheath was pulled back, and a 6-mm Amplatzer muscular ventricular septal defect occluder was deployed at the apical puncture site. Immediate hemostasis was achieved. Total hospitalization was 9 days. New York Heart Association functional class was improved, hemoglobin and haptoglobin rose, while lactate dehydrogenase fell. Follow-up fluoroscopy and transthoracic echocardiography revealed a good functional result. Closure of the apical access site by means of an Amplatzer muscular ventricular septal defect occluder is feasible.
Resumo:
Background Drugs of plant origin such as Arnica montana, Calendula officinalis or Hypericum perforatum have been frequently used to promote wound healing. While their effect on wound healing using preparations at pharmacological concentrations was supported by several in vitro and clinical studies, investigations of herbal homeopathic remedies on wound healing process are rare. The objective of this study was to investigate the effect of a commercial low potency homeopathic remedy Similasan® Arnica plus Spray on wound closure in a controlled, blind trial in vitro. Methods We investigated the effect of an ethanolic preparation composed of equal parts of Arnica montana 4x, Calendula officinalis 4x, Hypericum perforatum 4x and Symphytum officinale 6x (0712–2), its succussed hydroalcoholic solvent (0712–1) and unsuccussed solvent (0712–3) on NIH 3T3 fibroblasts. Cell viability was determined by WST-1 assay, cell growth using BrdU uptake, cell migration by chemotaxis assay and wound closure by CytoSelect ™Wound Healing Assay Kit which generated a defined “wound field”. All assays were performed in three independent controlled experiments. Results None of the three substances affected cell viability and none showed a stimulating effect on cell proliferation. Preparation (0712–2) exerted a stimulating effect on fibroblast migration (31.9%) vs 14.7% with succussed solvent (0712–1) at 1:100 dilutions (p < 0.001). Unsuccussed solvent (0712–3) had no influence on cell migration (6.3%; p > 0.05). Preparation (0712–2) at a dilution of 1:100 promoted in vitro wound closure by 59.5% and differed significantly (p < 0.001) from succussed solvent (0712–1), which caused 22.1% wound closure. Conclusion Results of this study showed that the low potency homeopathic remedy (0712–2) exerted in vitro wound closure potential in NIH 3T3 fibroblasts. This effect resulted from stimulation of fibroblasts motility rather than of their mitosis.
Resumo:
In excisional body-contouring surgery the surgeon is often confronted with time-consuming closure of long wounds. Recently, a new combination of a self-adhering mesh together with a liquid 2-octyl cyanoacrylate adhesive (Prineo™; Ethicon, Inc., Somerville, NJ, USA) has been introduced to replace intracutaneous running suture.
Resumo:
Measurements of maximum urethral closure pressure (MUCP) are a part of urodynamic investigations preceding an incontinence surgery and a part of urethral function tests.
Resumo:
Background Patients late after open-heart surgery may develop dual-loop reentrant atrial arrhythmias, and mapping and catheter ablation remain challenging despite computer-assisted mapping techniques. Objectives The purpose of the study was to demonstrate the prevalence and characteristics of dual-loop reentrant arrhythmias, and to define the optimal mapping and ablation strategy. Methods Fourty consecutive patients (mean age 52+/-12 years) with intra-atrial reentrant tachycardia (IART) after open-heart surgery (with an incision of the right atrial free wall) were studied. Dual-loop IART was defined as the presence of two simultaneous atrial circuits. Following an abrupt tachycardia change during radiofrequency (RF) ablation, electrical disconnection of the targeted reentry isthmus from the remaining circuit was demonstrated by entrainment mapping. Furthermore, the second circuit loop was localized using electroanatomic mapping and/or entrainment mapping. Results Dual-loop IART was demonstrated in 8 patients (20%, 5 patients with congenital heart disease, 3 with acquired heart disease). Dual-loop IART included an isthmus-dependant atrial flutter combined with a reentry related to the atriotomy scar. The diagnosis of dual-loop IART required the comparison of entrainment mapping before and after tachycardiamodification. Overall, 35 patients had successful RF ablation (88%). Success rates were lower in patients with dual-loop IART than in patient without dual-loop IART. Ablation failures in 3 patients with dual-loop IART were related to the inability to properly transect the second tachycardia isthmus in the right atrial free wall. Conclusions Dual-loop IART is relatively common after heart surgery involving a right atriotomy. Abrupt tachycardia change and specific entrainment mapping maneuvers demonstrate these circuits. Electroanatomic mapping appears to be important to assist catheter ablation of periatriotomy circuits.
Resumo:
Iatrogenic atrial septal defects are described in 2 patients. They occurred after implantation of Amplatzer occluders to close a patent foramen ovale. While device erosions to the extra-atrial space have been described, erosion induced atrial septal defects are a new medical entity. They may be fairly common in the situation of an atrial septal aneurysm whipping the rim of the device incessantly. They are clinically silent and benign and require echocardiography for detection. A second device solved the problem in the cases described.
Resumo:
Two young women with angiographically normal coronary arteries suffered an acute myocardial infarction. Both were found to have a patent foramen ovale (PFO), the likely pathway of a paradoxical embolus causing the infarction. The PFOs were diagnosed and closed percutaneously with an Amplatzer PFO Occluder during the emergency coronary angiography.
Resumo:
BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.
Resumo:
BACKGROUND: The effectiveness of various appendiceal stump closure methods has not been evaluated systematically. The aim of this study was to compare the morbidity of stump closure by stapling or use of endoloops. METHODS: A non-concurrent cohort study of prospectively acquired data was performed. The primary outcome variable was the rate of intra-abdominal surgical-site infection. Secondary outcome measures were complications, duration of intervention, hospital stay, rate of readmission to hospital and the difference in direct costs of the operation. RESULTS: Staples were used in 60.5 per cent and endoloops in 39.5 per cent of 6486 patients operated on for suspected appendicitis between January 1995 and December 2003. Among 4489 patients with acute appendicitis the rate of intra-abdominal surgical-site infection was 0.7 per cent in the stapler group and 1.7 per cent in the endoloop group (P = 0.004). The rate of readmission to hospital was 0.9 and 2.1 per cent respectively (P = 0.001). CONCLUSION: Application of a stapler for transection and closure of the appendiceal stump in patients with acute appendicitis lowered the risk of postoperative intra-abdominal surgical-site infection and the need for readmission to hospital.