897 resultados para fault correction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, there has been an increasing demand for operational and trustworthy digital data transmission and storage systems. This demand has been augmented by the appearance of large-scale, high-speed data networks for the exchange, processing and storage of digital information in the different spheres. In this paper, we explore a way to achieve this goal. For given positive integers n,r, we establish that corresponding to a binary cyclic code C0[n,n-r], there is a binary cyclic code C[(n+1)3k-1,(n+1)3k-1-3kr], where k is a nonnegative integer, which plays a role in enhancing code rate and error correction capability. In the given scheme, the new code C is in fact responsible to carry data transmitted by C0. Consequently, a codeword of the code C0 can be encoded by the generator matrix of C and therefore this arrangement for transferring data offers a safe and swift mode. © 2013 SBMAC - Sociedade Brasileira de Matemática Aplicada e Computacional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of perineal hernias in dogs during routine clinical surgery is frequent. The coexistence of rectal diseases that go undiagnosed or are not correctly treated can cause recurrence and postoperative complications. The objective of this report is to describe a surgical technique for treatment of rectal sacculation through lateral resection in dogs with perineal hernia, whereby restoring the rectal integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An incompetent vulvar seal leads to reproductive failure, and a surgical intervention might be required. The present paper describes modifications to Pouret's surgery. We suggest the use of a simple interrupted vertical mattress suture, which avoids seroma. Eighteen Brazilian Jumping Horse mares, older than 20 years and barren for 3-5 consecutive years, underwent modified Pouret's surgery. A horizontal skin incision of 3-4 cm was made half way between the anus and upper commissure of the vulva. The submucosal and connective tissue were dissected, and the rectovaginal shelf was split horizontally by sectioning the muscular and ligamentous connections between the anus, vulva, caudal portion of the rectum, and vagina until the vulva was oriented vertically. The wound was changed from a horizontal plane to a vertical plane by placing the suture vertically using approximately eight interrupted U sutures distributed in two layers with polyamide thread. The modified Pouret's surgical technique provided a perfect coaptation of the vulvar lips and a correct perineal position. Those mares that presented with horizontally tipped vulvar lips due to advanced age and stretching of the pelvic tissues by multiple foaling had their vulvas replaced. Also, the surgical procedure was easy to perform. As to fertility, of the 18 initial mares, 14 were inseminated, and all became pregnant. Thus, it was possible to conclude that the anatomical changes performed throughout the surgical procedure predisposed to a better vulvar coaptation, correcting the pneumovagina. © 2013 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Far from the continental margin, drainage basins in Central Amazonia should be in topographic steady state; but they are not. Abandoned remnant fluvial valleys up to hundreds of square kilometers in size are observed throughout Amazonia, and are evidence of significant landscape reorganization. While major Late Miocene drainage shifts occurred due to initiation of the transcontinental Amazon River, local landscape change has remained active until today. Driven either by dynamic topography, tectonism, and/or climatic fluctuations, drainage captures in Amazonia provide a natural experiment for assessing the geomorphic response of low-slope basins to sudden, capture related base-level falls. This paper evaluates the timing of geomorphic change by examining a drainage capture event across the Baependi fault scarp involving the Cuieiras and TarumA-Mirim River basins northwest of the city of Manaus in Brazil. A system of capture-related knickpoints was generated by base-level fall following drainage capture; through numerical modeling of their initiation and propagation, the capture event is inferred to have occurred between the middle and late Pleistocene, consistent with other studies of landscape change in surrounding areas. In low-slope settings like the Amazon River basin, base-level fall can increase erosion rates by more than an order of magnitude, and moderate to large river basins can respond to episodes of base-level fall over timescales of tens to hundreds of thousands of years. Copyright (c) 2013 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A superconducting fault current limiter (SCFL) consisted of a transformer with low reactance connected to the power line and with the secondary winding short-circuited by a modular superconducting limiter device with 16 elements connected in series was constructed and tested. The designed coupling transformer has low dispersion reactance in order to limit the voltage drop in the power line within the range of 5 % to 10 %. The experimental results showed that an insertion of a 0.125 Omega resistance limited the peak current to a factor of 2.5 times of the unlimited current. The power dissipation reached 39 kW during 100 ms, with an energy density of 380 J/cm(3). Based on these results, the SCFL will be further tested in a 3 MVA (15 kV/380 V) generator for currents up to 10 kA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i) abutment substitution to compensate the incorrect angulation of the implant, (ii) clinical crown lengthening, (iii) atraumatic extraction of the left central incisor, and (iv) immediate implant placement. Finally, (v) a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resistive-type of superconducting fault current limiters (RSFCL) have been developed for medium voltage class aiming to operate at 1 MVA power capacity and short time recovery (< 2 s). A RSFCL in form of superconducting modular device was designed and constructed using 50 m-length of YBCO coated conductor tapes for operation under 1 kV / 1 kA and acting time of 0.1 s. In order to increase the acting time the RSFCL was combined with an air-core reactor in parallel to increase the fault limiting time up to 1 s. The tests determined the electrical and thermal characteristics of the combined resistive/ inductive protection unit. The combined fault current limiter reached a limiting current of 583 A, corresponding to a limiting factor of 3.3 times within an acting time of up to 1 s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correction of functional posterior crossbite through Planas Direct Tracks has many characteristics that can become advantages. The aim of this study was to present a clinical case showing how to use this procedure for early correction with resources available through public health services. The patient, a 4-year-old girl, arrived to receive treatment due to a functional unilateral crossbite. When the mandible was moved to the centric position, it was observed that the teeth had occlusal trauma. An occlusal adjustment was performed. The adjustment was not sufficient to promote functional equilibrium; thus, Planas Direct Tracks were made, resulting in functional equilibrium and correction of the malocclusion. As shown in the case report, the Planas Direct Tracks were effective for the correction of the posterior crossbite. If malocclusion is considered a public health problem, implementation of low-cost and easy-to-execute techniques is needed.