912 resultados para cone-beam CT
Resumo:
AbstractIntroduction:Coronary computed tomography angiography (CCTA) allows for non-invasive coronary artery disease (CAD) phenotyping. There are still some uncertainties regarding the impact this knowledge has on the clinical care of patients.Objective:To determine whether CAD phenotyping by CCTA influences clinical decision making by the prescription of cardiovascular drugs and their impact on non-LDL cholesterol (NLDLC) levels.Methods:We analysed consecutive patients from 2008 to 2011 submitted to CCTA without previous diagnosis of CAD that had two serial measures of NLDLC, one up to 3 months before CCTA and the second from 3 to 6 months after.Results:A total of 97 patients were included, of which 69% were men, mean age 64 ± 12 years. CCTA revealed that 18 (18%) patients had no CAD, 38 (39%) had non-obstructive (< 50%) lesions and 41 (42%) had at least one obstructive ≥ 50% lesion. NLDLC was similar at baseline between the grups (138 ± 52 mg/dL vs. 135 ± 42 mg/dL vs. 131 ± 44 mg/dL, respectively, p = 0.32). We found significative reduction in NLDLC among patients with obstrctive lesions (-18%, p = 0.001). We also found a positive relationship between clinical treatment intensification with aspirin and cholesterol reducing drugs and the severity of CAD.Conclusion:Our data suggest that CCTA results were used for cardiovascular clinical treatment titration, with especial intensification seen in patients with obstructive ≥50% CAD.
Resumo:
Magdeburg, Univ., Med. Fak., Diss., 2011
Resumo:
This work presents the results of an investigation of processes in the melting zone during Electron Beam Welding(EBW) through analysis of the secondary current in the plasma.The studies show that the spectrum of the secondary emission signal during steel welding has a pronounced periodic component at a frequency of around 15–25 kHz. The signal contains quasi-periodic sharp peaks (impulses). These impulses have stochastically varying amplitude and follow each other inseries, at random intervals between series. The impulses have a considerable current (up to 0.5 A). It was established that during electron-beam welding with the focal spot scanning these impulses follow each other almost periodically. It was shown that the probability of occurrence of these high-frequency perturbation increases with the concentration of energy in the interaction zone. The paper also presents hypotheses for the mechanism of the formation of the high-frequency oscillations in the secondary current signal in the plasma.
Resumo:
Die Mesostruktur von Werkstoffen wie Faserverbundwerkstoffen und Schaumstoffen beeinflusst deren mechanisches Verhalten wesentlich. Die inneren Strukturen des Werkstoffes müssen in die Analyse des Verformungs- und Versagensverhaltens einbezogen werden. Die Röntgenanalyse, insbesondere die Röntgen-Computertomographie (Röntgen-CT) ermöglicht eine zerstörungsfreie 3-dimensionale (3-d) Visualisierungund Charakterisierung innerer Strukturen. Für die Untersuchung des Einflusses der Mesostruktur eines Polymethacrymlid-Hartschaumstoffes auf das mechanische Verhalten speziell unter zugbelastung sollte eine speziell vom Fraunhofer-Institut für Werkstoffmechanik in Halle entwickelte In-situ-Verformungseinrichtung erprobt werden. Die Anlage wurde speziell für den Zugversuch optimiert. Es folgten mechanische Experimente, die mit den 3d-Bilddaten der Zellstruktur des Schaumstoffes korrelieren. Die ermittelten Bilddaten werden mit Hilfe einer Bildanalysesoftware ausgewertet und Rückschlüsse auf Verformungs- und Versagensverhalten grtroffen.
Resumo:
Universität Magdeburg, Univ., Dissertation, 2016
Resumo:
v.13:no.4(1964)
Resumo:
We study of noncompact Euclidean cone manifolds with cone angles less than c&2π and singular locus a submanifold. More precisely, we describe its structure outside a compact set. As a corol lary we classify those with cone angles & 2π/3 and those with cone angles = 2π/3.
Resumo:
Estudio elaborado a partir de una estancia en el Karolinska University Hospital, Suecia, entre marzo y junio del 2006. En la radioterapia estereotáxica extracraneal (SBRT) de tumores de pulmón existen principalmente dos problemas en el cálculo de la dosis con los sistemas de planificación disponibles: la precisión limitada de los algoritmos de cálculo en presencia de tejidos con densidades muy diferentes y los movimientos debidos a la respiración del paciente durante el tratamiento. El objetivo de este trabajo ha sido llevar a cabo la simulación con el código Monte Carlo PENELOPE de la distribución de dosis en tumores de pulmón en casos representativos de tratamientos con SBRT teniendo en cuenta los movimientos respiratorios y su comparación con los resultados de varios planificadores. Se han estudiado casos representativos de tratamientos de SBRT en el Karolinska University Hospital. Los haces de radiación se han simulado mediante el código PENELOPE y se han usado para la obtención de los resultados MC de perfiles de dosis. Los resultados obtenidos para el caso estático (sin movimiento respiratorio ) ponen de manifiesto que, en comparación con la MC, la dosis (Gy/MU) calculada por los planificadores en el tumor tiene una precisión del 2-3%. En la zona de interfase entre tumor y tejido pulmonar los planificadores basados en el algoritmo PB sobrestiman la dosis en un 10%, mientras que el algoritmo CC la subestima en un 3-4%. Los resultados de la simulación mediante MC de los movimientos respiratorios indican que los resultados de los planificadores son suficientemente precisos en el tumor, aunque en la interfase hay una mayor subestimación de la dosis en comparación con el caso estático. Estos resultados son compatibles con la experiencia clínica adquirida durante 15 años en el Karolinska University Hospital. Los resultados se han publicado en la revista Acta Oncologica.
Resumo:
A 67-year-old woman was referred for staging of a mucosa-associated lymphoid tumor lymphoma involving the left conjunctiva. CT scan had shown paravertebral and pelvic masses, and a breast nodule. FDG PET/CT demonstrated moderately increased uptake in the left ocular conjunctiva and confirmed the paravertebral and pelvic masses and the breast nodule. Moreover, abnormal FDG uptake was shown in 2 breast nodules, the flank, the gluteus maximus, and the gastric cardia. The patient received 6 cycles of rituximab-bendamustine chemotherapy with a complete clinical and metabolic response at the 6-month follow-up PET/CT and remained relapse-free without visual acuity problem after a 36-month follow-up.
Resumo:
The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.
Resumo:
NR2E3, also called photoreceptor-specific nuclear receptor (PNR), is a transcription factor of the nuclear hormone receptor superfamily whose expression is uniquely restricted to photoreceptors. There, its physiological activity is essential for proper rod and cone photoreceptor development and maintenance. Thirty-two different mutations in NR2E3 have been identified in either homozygous or compound heterozygous state in the recessively inherited enhanced S-cone sensitivity syndrome (ESCS), Goldmann-Favre syndrome (GFS), and clumped pigmentary retinal degeneration (CPRD). The clinical phenotype common to all these patients is night blindness, rudimental or absent rod function, and hyperfunction of the "blue" S-cones. A single p.G56R mutation is inherited in a dominant manner and causes retinitis pigmentosa (RP). We have established a new locus-specific database for NR2E3 (www.LOVD.nl/eye), containing all reported mutations, polymorphisms, and unclassified sequence variants, including novel ones. A high proportion of mutations are located in the evolutionarily-conserved DNA-binding domains (DBDs) and ligand-binding domains (LBDs) of NR2E3. Based on homology modeling of these NR2E3 domains, we propose a structural localization of mutated residues. The high variability of clinical phenotypes observed in patients affected by NR2E3-linked retinal degenerations may be caused by different disease mechanisms, including absence of DNA-binding, altered interactions with transcriptional coregulators, and differential activity of modifier genes.
Resumo:
Purpose: To report a novel maculopathy in a patient with SCA1. To describe autofluorescence findings in family with SCA7 and associated cone-rod retinal dysfunction.Methods: 4 affected patients from two families were assessed to investigate a progressive loss of visual acuity (VA). Examinations included fundus photography, autofluorescence (AF) fundus fluorescein angiogragraphy (FFA) and optical coherence tomography. Electroretinogram (full-field) was performed in 2 affected patients. All patients had color vision testing using Ishihara pseudoisochromatic plates. Molecular analysis was performed in family 2.Results: The patient with known diagnosis of SCA1 had a visual acuity of 20/200 bilaterally and dyschromatopsia. He had saccadic pursuit. Fundus examination showed mild retinal pigment epithelium (RPE) changes at the macula. OCT showed bilateral macular serous detachment, which was not obvious at the FFA and explained his VA. AF imaging showed a central hyperfluorescence. The 45 year old proband from family 2 had a visual acuity of 200/20 and dyschromatopsia. ERG testing showed cone type dysfunction of photoreceptors. Her daughter affected at a younger age had the same ERGs findings. Fundus examination showed mild RPE changes in proband, normal findings in her daughter. AF imaging of both patients showed a ring of high density AF around the fovea. The ring was also obvious on near infrared AF. Later onset of gait imbalance led to the diagnosis of SCA7Conclusions: Within the group of spinocerebellar ataxias, only the type 7 is associated with retinal dysfunction. We present the first report of maculopathy associated with SCA1 causing severe vision loss. The ring of high density AF in SCA7 confirmed an early retinal photoreceptor dysfunction in patient with normal fundus.