987 resultados para building modeling
Resumo:
Applied Mathematical Modelling, Vol.33
Resumo:
Outlining the best strategies for seismic risk mitigation requires that both benefits and costs of retrofitting are known in advance. The assessment of the vulnerability of building typologies is a first step of a more extensive effort, concerning the analysis of the viability of seismic risk mitigation and taking into account retrofitting costs. The methodology adopted to obtain the seismic vulnerability of some classes of residential buildings existing in mainland Portugal is presented. This methodology is based on a structural analysis of individual buildings belonging to the same typology. An application example is presented to illustrate the methodology. Fragility curves of “boxed” building typology are also presented and broken down into three height classes: low rise, medium-rise and high-rise. These curves are based on average capacity spectra derived from several individual buildings belonging to the same typology.
Resumo:
Dual-phase functionally graded materials are a particular type of composite materials whose properties are tailored to vary continuously, depending on its two constituent's composition distribution, and which use is increasing on the most diverse application fields. These materials are known to provide superior thermal and mechanical performances when compared to the traditional laminated composites, exactly because of this continuous properties variation characteristic, which enables among other advantages smoother stresses distribution profile. In this paper we study the influence of different homogenization schemes, namely the schemes due to Voigt, Hashin-Shtrikman and Mod-Tanaka, which can be used to obtain bounds estimates for the material properties of particulate composite structures. To achieve this goal we also use a set of finite element models based on higher order shear deformation theories and also on first order theory. From the studies carried out, on linear static analyses and on free vibration analyses, it is shown that the bounds estimates are as important as the deformation kinematics basis assumed to analyse these types of multifunctional structures. Concerning to the homogenization schemes studied, it is shown that Mori-Tanaka and Hashin-Shtrikman estimates lead to less conservative results when compared to Voigt rule of mixtures.
Resumo:
Conferência: CONTROLO’2012 - 16-18 July 2012 - Funchal
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
An overview of the studies carried out in our laboratories on supercritical fluid extraction (SFE) of volatile oils from seven aromatic plants: pennyroyal (Mentha pulegium L.), fennel seeds (Foeniculum vulgare Mill.), coriander (Coriandrum sativum L.), savory (Satureja fruticosa Beguinot), winter savory (Satureja montana L.), cotton lavender (Santolina chamaecyparisus) and thyme (Thymus vulgaris), is presented. A flow apparatus with a 1 L extractor and two 0.27 L separators was built to perform studies at temperatures ranging from 298 to 353 K and pressures up to 30.0 MPa. The best compromise between yield and composition compared with hydrodistillation (HD) was achieved selecting the optimum experimental conditions of extraction and fractionation. The major differences between HD and SFE oils is the presence of a small percentage of cuticular waxes and the relative amount of thymoquinone, an oxygenated monoterpene with important biological properties, which is present in the oils from thyme and winter savory. On the other hand, the modeling of our data on supercritical extraction of volatile oil from pennyroyal is discussed using Sovova's models. These models have been applied successfully to the other volatile oil extractions. Furthermore, other experimental studies involving supercritical CO2 carried out in our laboratories are also mentioned.
Resumo:
Signal Processing, Vol. 86, nº 10
Resumo:
Most of the traditional software and database development approaches tend to be serial, not evolutionary and certainly not agile, especially on data-oriented aspects. Most of the more commonly used methodologies are strict, meaning they’re composed by several stages each with very specific associated tasks. A clear example is the Rational Unified Process (RUP), divided into Business Modeling, Requirements, Analysis & Design, Implementation, Testing and Deployment. But what happens when the needs of a well design and structured plan, meet the reality of a small starting company that aims to build an entire user experience solution. Here resource control and time productivity is vital, requirements are in constant change, and so is the product itself. In order to succeed in this environment a highly collaborative and evolutionary development approach is mandatory. The implications of constant changing requirements imply an iterative development process. Project focus is on Data Warehouse development and business modeling. This area is usually a tricky one. Business knowledge is part of the enterprise, how they work, their goals, what is relevant for analyses are internal business processes. Throughout this document it will be explained why Agile Modeling development was chosen. How an iterative and evolutionary methodology, allowed for reasonable planning and documentation while permitting development flexibility, from idea to product. More importantly how it was applied on the development of a Retail Focused Data Warehouse. A productized Data Warehouse built on the knowledge of not one but several client needs. One that aims not just to store usual business areas but create an innovative sets of business metrics by joining them with store environment analysis, converting Business Intelligence into Actionable Business Intelligence.
Resumo:
This paper models an n-stage stacked Blumlein generator for bipolar pulses for various load conditions. Calculation of the voltage amplitudes in time domain at the load and between stages is described for an n-stage generator. For this, the reflection and transmission coefficients are mathematically modeled where impedance discontinuity occurs (i.e., at the junctions between two transmission lines). The mathematical model developed is assessed by comparing simulation results to experimental data from a two-stage Blumlein solid-state prototype.
Resumo:
Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.
Resumo:
In this study the inhalation doses and respective risk are calculated for the population living within a 20 km radius of a coal-fired power plant. The dispersion and deposition of natural radionuclides were simulated by a Gaussian dispersion model estimating the ground level activity concentration. The annual effective dose and total risk were 0.03205 mSv/y and 1.25 x 10-8, respectively. The effective dose is lower than the limit established by the ICRP and the risk is lower than the limit proposed by the U.S. EPA, which means that the considered exposure does not pose any risk for the public health.
Resumo:
A implementação da evolução tecnológica no setor da construção tem se caracterizado pelo aparecimento de novas tecnologias que dinamizam os processos de troca de informação entre os vários intervenientes no ciclo de vida do empreendimento. O surgimento da tecnologia Building Information Modeling - BIM assente na modelação paramétrica e na interoperabilidade suportada em ficheiros de padrão aberto (IFC) pressupõem um novo paradigma na forma como são tratados os processos de troca de informação entre os vários intervenientes no ciclo de vida dos empreendimentos. Com base no BIM o Construction Operations Building Information Exchange – COBie, é outra tecnologia recente que recolhe informações não geométricas associadas ao modelo e em conjunto com a informação geométrica produzida pelo BIM fazem parte dos documentos de entrega para a fase Facility Management – FM. O objetivo da presente dissertação centrou-se no estudo da evolução de um modelo BIM de construção para a gestão de empreendimento. Foi desenvolvido o estudo de um modelo protótipo que incidiu na utilização de softwares para verificação e aplicação das tecnologias COBie e BIM e também foi sincronizado com a fase FM. Da aplicação dos requisitos COBie e modelação BIM foram extraídas informações geométricas e não geométricas preenchidas nas folhas de trabalho COBie. As principais conclusões do estudo realizado foram que as tecnologias COBie e BIM têm pouca implantação a nível nacional e a sua integração dinamiza os processos, reduzindo custos e aumentando a qualidade da informação fornecida.
Resumo:
O crescente aumento da consciencialização da importância da fase de operação e manutenção, bem como a amplificação que a metodologia Building Information Modelling (BIM) tem obtido nos últimos anos, sugere uma necessidade de alterar a atual abordagem da gestão das instalações de forma a dotá-la das mais recentes inovações tecnológicas como seja a utilização do BIM. Os Building Information Models apresentam as características ideais para a integração da gestão das instalações, não só pela visualização do edifício, mas sobretudo pela potencialidade que a base de dados oferece, com informação referente a cada um dos componentes presentes e suas relações. O âmbito deste trabalho envolve assim a integração da gestão das instalações com o modelo BIM criado, representativo do edifício em estudo. Este trabalho começa com as definições do âmbito e dos objetivos que são propostos no Capítulo 1. No Capítulo 2, é elaborada uma pesquisa sobre o estado da arte atual de cada uma das metodologias BIM e FM, de forma a tomar conhecimento dos seus conceitos principais. Foi feito também um levantamento no campo do BIM-FM de forma a apurar as atuais soluções tecnológicas existentes, a forma como é feita a sua troca de informação e também alguns casos em que esta metodologia foi aplicada. Com base na informação recolhida sobre as metodologias e também nos casos práticos estudados, é realizado no Capítulo 3, capítulo central deste trabalho, a aplicação prática. A realização desta aplicação é dividida por 3 fases principais. Numa primeira fase é especificada e recolhida a informação necessária de ser obtida para a realização do modelo e a posterior aplicação do FM. A escolha da informação a recolher é feita ponderando todos os fatores existentes, mas de forma a cumprir os requisitos pedidos. Numa segunda fase, assente na compilação de informação recolhida anteriormente, realiza-se o modelo do edifício. A modelação, de forma a seguir o método de trabalho BIM é realizada por especialidades, sendo numa primeira fase realizada a especialidade de arquitetura e posteriormente, utilizando esse modelo como base, é feita a modelação das especialidades de águas, águas residuais, AVAC e eletricidade. Esta escolha foi também estimulada pela organização do software utilizado para a modelação, por módulos. Na última fase da aplicação do caso prático a informação inserida na fase de modelação do edifício é exportada para o software de FM, neste caso em específico, o IBM Maximo. Para a exportação destes dados foi utilizado o formato Construction Operations Building Information Exchange (COBie), de forma a garantir a integridade e conformidade da informação transferida. No Capítulo 4 deste trabalho são abordadas as especificidades relativas à informação existente, à modelação e à troca de dados entre o software de modelação e o software utilizado na gestão do edifício. São também sugeridos alguns temas para futuros desenvolvimentos com o intuito de ampliação dos campos de FM com o uso do modelo. O BIM-FM é um tema emergente na atualidade do BIM, sendo a sua utilização encarada como uma mais-valia ao processo BIM. A compilação da informação durante a fase de projeto e execução, aliada à existência do modelo torna a implementação do FM com o modelo BIM como uma sequência natural.
Resumo:
Business History, Vol 50 No 2, p147-162
Resumo:
Pultrusion is an industrial process used to produce glass fibers reinforced polymers profiles. These materials are worldwide used when performing characteristics, such as great electrical and magnetic insulation, high strength to weight ratio, corrosion and weather resistance, long service life and minimal maintenance are required. In this study, we present the results of the modelling and simulation of heat flow through a pultrusion die by means of Finite Element Analysis (FEA). The numerical simulation was calibrated based on temperature profiles computed from thermographic measurements carried out during pultrusion manufacturing process. Obtained results have shown a maximum deviation of 7%, which is considered to be acceptable for this type of analysis, and is below to the 10% value, previously specified as maximum deviation. © 2011, Advanced Engineering Solutions.