866 resultados para assessment evaluation
Resumo:
Background and objective: Therapeutic Drug Monitoring (TDM) has been introduced early 1970 in our hospital (CHUV). It represents nowadays an important routine activity of the Division of Clinical Pharmacology and Toxicology (PCL), and its impact and utility for clinicians required assessment. This study thus evaluated the impact of TDM recommendations in terms of dosage regimen adaptation. Design: A prospective observational study was conducted over 5 weeks. The primary objective was to evaluate the application of our TDM recommendations and to identify potential factors associated to variations in their implementation. The secondary objective was to identify pre-analytical problems linked to the collection and processing of blood samples. Setting: Four representative clinical units at CHUV. Main outcome measure: Clinical data, drug related data (intake, collection and processing) and all information regarding the implementation of clinical recommendations were collected and analyzed by descriptive statistics. Results: A total of 241 blood measurement requests were collected, among which 105 triggered a recommendation. 37% of the recommendations delivered were applied, 25 % partially applied and 34% not applied. In 4% it was not applicable. The factors determinant for implementation were the clinical unit and the mode of transmission of the recommendation (written vs oral). No clear difference between types of drugs could be detected. Pre-analytical problems were not uncommon, mostly related to completion of request forms and delays in blood sampling (equilibration or steady-state not reached). We have identified 6% of inappropriate and unusable drug level measurements that could cause a substantial cost for the hospital. Conclusion: This survey highlighted a better implementation of TDM recommendations in clinical units where this routine is well integrated and understood by the medical staff. Our results emphasize the importance of communication with the nurse or the physician in charge, either to transmit clinical recommendations or to establish consensual therapeutic targets in specific conditions. Development of strong partnerships between clinical pharmacists or pharmacologists and clinical units would be beneficial to improve the impact of this clinical activity.
Resumo:
The assessment of medical technologies has to answer several questions ranging from safety and effectiveness to complex economical, social, and health policy issues. The type of data needed to carry out such evaluation depends on the specific questions to be answered, as well as on the stage of development of a technology. Basically two types of data may be distinguished: (a) general demographic, administrative, or financial data which has been collected not specifically for technology assessment; (b) the data collected with respect either to a specific technology or to a disease or medical problem. On the basis of a pilot inquiry in Europe and bibliographic research, the following categories of type (b) data bases have been identified: registries, clinical data bases, banks of factual and bibliographic knowledge, and expert systems. Examples of each category are discussed briefly. The following aims for further research and practical goals are proposed: criteria for the minimal data set required, improvement to the registries and clinical data banks, and development of an international clearinghouse to enhance information diffusion on both existing data bases and available reports on medical technology assessments.
Resumo:
Purpose: Dynamic high-field magnetic resonance (MR) defecography including the evacuation phase is a promising tool for the assessment of functional pelvic disorders, nowadays seen with increasing frequency in elderly women in particular. Learning objectives: 1. To describe the adequate technique of dynamic high-field MRI (3T) in assessing pelvic floor disorders. 2. To provide an overview of the most common pathologies occurring during the evacuation phase, especially in comparison with results of conventional defecography. Methods and materials: After description of the ideal technical parameters of MR defecography performed in supine position after gel rectal filling with a 3 Tesla unit and including the evacuation phase we stress the importance of using a standardized evaluation system for the exact assessment of pelvic floor pathophysiology. Results: The typical pelvic floor disorders occurring before and/or during the evacuation phase, such as sphincter insufficiency, vaginal vault and/or uterine prolapse, cystourethrocele, peritoneo-/ entero-/ sigmoïdocele or rectal prolapse, are demonstrated. The difference between the terms "pelvic floor descent" and "pelvic floor relaxation" are pictorially outlined. MR results are compared with these of conventional defecography. Conclusion: Exact knowledge about the correct technique including the evacuation phase and the use of a standardized evaluation system in assessing pelvic floor disorders by dynamic high-field MRI is mandatory for accurate and reproducible diagnosis.
Resumo:
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.
Resumo:
BACKGROUND: In patients with malignant pleural mesothelioma undergoing a multimodality therapy, treatment toxicity may outweigh the benefit of progression-free survival. The subjective experience across different treatment phases is an important clinical outcome. This study compares a standard with an individual quality of life (QoL) measure used in a multi-center phase II trial. PATIENTS AND METHODS: Sixty-one patients with stage I-III technically operable pleural mesothelioma were treated with preoperative chemotherapy, followed by pleuropneumonectomy and subsequent radiotherapy. QoL was assessed at baseline, at day 1 of cycle 3, and 1, 3 and 6 months post-surgery by using the Rotterdam Symptom Checklist (RSCL) and the Schedule for the Evaluation of Quality of Life-Direct Weighting (SEIQoL-DW), a measure that is based on five individually nominated and weighted QoL-domains. RESULTS: Completion rates were 98% (RSCL) and 92% (SEIQoL) at baseline and 98%/89% at cycle 3, respectively. Of the operated patients (N=45) RSCL and SEIQoL were available from 86%/72%, 93%/74%, and 94%/76% at months 1, 3, and 6 post-surgery. Average assessment time for the SEIQoL was 24min compared to 8min needed for the RSCL. Median changes from baseline indicate that both RSCL QoL overall score and SEIQoL index remained stable during chemotherapy with a clinically significant deterioration (change>or=8 points) 1 month after surgery (median change of -66 and -14 for RSCL and SEIQoL, respectively). RSCL QoL overall scores improved thereafter, but remained beneath baseline level until 6 months after surgery. SEIQoL scores improved to baseline-level at month 3 after surgery, but worsened again at month 6. RSCL QoL overall score and SEIQoL index were moderately correlated at baseline (r=.30; p<or=.05) and at 6-month follow-up (r=.42; p<or=.05) but not at the other time points. CONCLUSION: The SEIQoL assessment seems to be feasible within a phase II clinical trial, but may require more effort from staff. More distinctive QoL changes in accordance with clinical changes were measured with the RSCL. Our findings suggest that the two measures are not interchangeable: the RSCL is to favor when mainly information related to the course of disease- and treatment is of interest.
Resumo:
Purpose of the study: Reconstruction of the anterior cruciate ligament (ACL) controls laxity but does not enable restoration of strictly normal 3D kinematics. The purpose of this study was to compare the kinematics of the pathological knee with that of the healthy knee after ACL plasty. This study applied a new ambulatory system using miniature captors. Material and method: Five patients with an isolated injury of the ACL participated in this study. The patients were assessed after injury (T1), at five months (T2), and at 14 months (T3) after surgery. The assessment included laxity (KT-1000), the IKDC score and the Lysholm score. The 3D angles of the knees were measured when walking 30 m on flat ground using a system composed of to small inertia units (3D accelerometer and 3D gyroscope) and a portable recorder. Functional settings were optimised and validating to ensure easy precise measurement of the 3D angles. Symmetry of the two knees was quantified using a symmetry index (SI) (difference in amplitude normalised in relation to mean amplitude) and the correlation coefficient CC. Results: Clinical indicators improved during the follow-up (IKDC T1: 3C, 2C; T2: 5B; T3: 2A, 3B; subjective IKD: 53-95; Lysholm 67-96). Mean laxity improved from 8.6m to 2.5 mm. The gait analysis showed increased symmetry in terms of amplitude for flexion-extension (SI: −17% at T1, −1% at T2, 1% at T3), and an increase in symmetry in terms of the rotation signature (CC: 0.16 at T1, 0.99 at T2, 0.99 at T3). There was no trend to varus-valgus. Discussion: This study demonstrates the clinical application of the new ambulatory system for measuring 3D angles of the knee joint. Joint symmetry increased after ACL plasty but still showed some perturbation at 14 months. The results observed here are in agreement with the literature. Other patients and other types of gait are being analysed. Conclusion: This portable system allows gait analysis outside the laboratory, before and after ACL injury. It is very useful for follow-up after surgery.
Resumo:
Characterize ethylbenzene and xylene air concentrations, and explore the biological exposure markers (urinary t,t-muconic acid (t,t-MA) and unmetabolized toluene) among petroleum workers offshore. Offshore workers have increased health risks due to simultaneous exposures to several hydrocarbons present in crude oil. We discuss the pooled benzene exposure results from our previous and current studies and possible co-exposure interactions. BTEX air concentrations were measured during three consecutive 12-h work shifts among 10 tank workers, 15 process operators, and 18 controls. Biological samples were collected pre-shift on the first day of study and post-shift on the third day of the study. The geometric mean exposure over the three work shifts were 0.02 ppm benzene, 0.05 ppm toluene, 0.03 ppm ethylbenzene, and 0.06 ppm xylene. Benzene in air was significantly correlated with unmetabolized benzene in blood (r = 0.69, p < 0.001) and urine (r = 0.64, p < 0.001), but not with urinary t,t-MA (r = 0.27, p = 0.20). Toluene in air was highly correlated with the internal dose of toluene in both blood (r = 0.70, p < 0.001) and urine (r = 0.73, p < 0.001). Co-exposures were present; however, an interaction of metabolism was not likely at these low benzene and toluene exposures. Urinary benzene, but not t,t-MA, was a reliable biomarker for benzene at low exposure levels. Urinary toluene was a useful biomarker for toluene exposure. Xylene and ethylbenzene air levels were low. Dermal exposure assessment needs to be performed in future studies among these workers.
Resumo:
With some 30,000 dependent persons, opiate addiction constitutes a major public health problem in Switzerland. The Swiss Federal Office of Public Health (FOPH) has long played a leading role in the prevention and treatment of opiate addiction and in research on effective means of containing the epidemic of opiate addiction and its consequences. Major milestones on that path have been the successive "Methadone reports" published by that Office and providing guidance on the care of opiate addiction with substitution treatment. In view of updating the recommendations for the appropriateness of substitution treatment for opiate addiction, in particular for the prescription of methadone, the FOPH commissioned a multi-component project involving the following elements. A survey of current attitudes and practices in Switzerland related to opiate substitution treatment Review of Swiss literature on methadone substitution treatment Review of international literature on methadone substitution treatment National Methadone Substitution Conference Multidisciplinary expert panel to evaluate the appropriateness of substitution treatment. The present report documents the process and summarises the results of the latter element above. The RAND appropriateness method (RAM) was used to distil from literature-based evidence and systematically formulated expert opinion, areas where consensus exist on the appropriateness (or inappropriateness) of methadone maintenance treatment (MMT) and areas where disagreement or uncertainty persist and which should be further pursued. The major areas which were addressed by this report are Initial assessment of candidates for MMT Appropriate settings for initiation of MMT (general and special cases) Appropriateness of methadone supportive therapy Co-treatments and accompanying measures Dosage schedules and pharmacokinetic testing Withdrawal from MMT Miscellaneous questions Appropriateness of other (non-methadone) substitution treatment Summary statements for each of the above categories are derived from the panel meeting and presented in the report. In the "first round", agreement was observed for 31% of the 553 theoretical scenarios evaluated. The "second round" rating, following discussion of divergent ratings, resulted in a much higher agreement among panellists, reaching 53% of the 537 scenarios. Frank disagreement was encountered for 7% of all scenarios. Overall 49% of the clinical situations (scenarios) presented were considered appropriate. The areas where at least 50% of the situations were considered appropriate were "initial assessment of candidates for MMT", the "appropriate settings for initiation of MMT", the "appropriate settings for methadone supportive treatment" and "Appropriateness of other (non-methadone) substitution treatment". The area where there was the least consensus on appropriateness concerned "appropriateness of withdrawal from MMT" (6%). The report discusses the implications and limitations of the panel results and provides recommendations for the dissemination, application, and future use of the criteria for the appropriateness of MMT. The RAND Appropriateness Method proved to be an accepted and appreciated method to assess the appropriateness of methadone maintenance treatment for opiate addicts. In the next step, the results of the expert panel process must now be combined with those of the Swiss and international literature reviews and the survey of current attitudes and practices in Switzerland, to be synthesized into formal practice guidelines. Such guidelines should be disseminated to all concerned, promoted, used and rigorously evaluated for compliance and outcome.
Resumo:
Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.
Resumo:
Introduction: Osteoporosis (OP) is a systemic skeletal disease characterized by a low bone mineral density (BMD) and a micro-architectural (MA) deterioration. Clinical risk factors (CRF) are often used as a MA approximation. MA is yet evaluable in daily practice by the Trabecular Bone Score (TBS) measure. TBS is a novel grey-level texture measurement reflecting bone micro-architecture based on the use of experimental variograms of 2D projection images. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis value, partially independent of CRF and BMD. The aim of the OsteoLaus cohort is to combine in daily practice the CRF and the information given by DXA (BMD, TBS and vertebral fracture assessment (VFA)) to better identify women at high fracture risk. Method: The OsteoLaus cohort (1400 women 50 to 80 years living in Lausanne, Switzerland) started in 2010. This study is derived from the cohort COLAUS who started in Lausanne in 2003. The main goals of COLAUS is to obtain information on the epidemiology and genetic determinants of cardiovascular risk in 6700 men and women. CRF for OP, bone ultrasound of the heel, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded in OsteoLaus. Preliminary results are reported. Results: We included 631 women: mean age 67.4±6.7 y, BMI 26.1±4.6, mean lumbar spine BMD 0.943±0.168 (T-score -1.4 SD), TBS 1.271±0.103. As expected, correlation between BMD and site matched TBS is low (r2=0.16). Prevalence of VFx grade 2/3, major OP Fx and all OP Fx is 8.4%, 17.0% and 26.0% respectively. Age- and BMI-adjusted ORs (per SD decrease) are 1.8 (1.2- 2.5), 1.6 (1.2-2.1), 1.3 (1.1-1.6) for BMD for the different categories of fractures and 2.0 (1.4-3.0), 1.9 (1.4-2.5), 1.4 (1.1-1.7) for TBS respectively. Only 32 to 37% of women with OP Fx have a BMD < -2.5 SD or a TBS < 1.200. If we combine a BMD < -2.5 SD or a TBS < 1.200, 54 to 60% of women with an osteoporotic Fx are identified. Conclusion: As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS subsequent to BMD increases significantly the identification of women with prevalent OP Fx which would have been miss-classified by BMD alone. For the first time we are able to have complementary information about fracture (VFA), density (BMD), micro- and macro architecture (TBS & HAS) from a simple, low ionizing radiation and cheap device: DXA. Such complementary information is very useful for the patient in the daily practice and moreover will likely have an impact on cost effectiveness analysis.
Resumo:
Abstract Objectives: In Germany since 2007 children with advanced life-limiting diseases are eligible for Pediatric Palliative Home Care (PPHC), which is provided by newly established specialized PPHC teams. The objective of this study was to evaluate the acceptance and effectiveness of PPHC as perceived by the parents. Methods: Parents of children treated by the PPHC team based at the Munich University Hospital were eligible for this prospective nonrandomized study. The main topics of the two surveys (before and after involvement of the PPHC team) were the assessment of symptom control and quality of life (QoL) in children; and the parents' satisfaction with care, burden of patient care (Häusliche Pflegeskala, home care scale, HPS), anxiety and depression (Hospital Anxiety and Depression Scale, HADS), and QoL (Quality of Life in Life-Threatening Illness-Family Carer Version, QOLLTI-F). Results: Of 43 families newly admitted to PPHC between April 2011 and June 2012, 40 were included in the study. The median interval between the first and second interview was 8.0 weeks. The involvement of the PPHC team led to a significant improvement of children's symptoms and QoL (P<0.001) as perceived by the parents; and the parents' own QoL and burden relief significantly increased (QOLLTI-F, P<0.001; 7-point change on a 10-point scale), while their psychological distress and burden significantly decreased (HADS, P<0.001; HPS, P<0.001). Conclusions: The involvement of specialized PPHC appears to lead to a substantial improvement in QoL of children and their parents, as experienced by the parents, and to lower the burden of home care for the parents of severely ill children.
Resumo:
In order to determine the frequency of therapeutic failures to chloroquine (CQ) in patients with malaria due to either Plasmodium falciparum or P. vivax, and to explore the usefulness of a malaria-free city as a sentinel site to monitor the emergence of drug resistance, 53 patients (44 infected with P. vivax and 9 with P. falciparum) were evaluated at the Laboratory of Parasitology, Universidad del Valle in Cali, Colombia. Patients received 25 mg/kg of CQ divided in three doses over 48 h; they were followed during 28 days according to WHO/PAHO protocols. While therapeutic failures to CQ in the P. vivax group were not detected, the proportion of therapeutic failures in the P. falciparum group was high (78%) and consistent with the reports from endemic areas in Colombia. The diverse origin of cases presenting therapeutic failure confirmed that P. falciparum resistant to CQ is widespread in Colombia, and further supports the change in the national antimalarial drug scheme. Monitoring of drug resistance in malaria free areas would be useful to identify sites requiring efficacy evaluation, and in some situations could be the most appropriate alternative to collect information from endemic areas where therapeutic efficacy studies are not feasible.
Resumo:
Purpose: Extension of retinoblastoma cells anterior to the vitreous surface is a criteria used to categorize retinoblastomas in Group E. In some cases, the assessment of anterior chamber invasion is readily visible by slit lamp examination, but in other cases, invasion of the posterior chamber is clinically difficult to determinate. Ultrasound biomicroscopy (UBM) allows high-resolution images of the anterior segment and structures normally hidden from clinical visualization such as ciliary body, zonule or posterior chamber. This prompted us to evaluate the value of UBM in the assessment of posterior and anterior chamber involvement in patients with peripheral extending retinoblastomas. Methods: We retrospectively reviewed all retinoblastoma cases that underwent enucleation in our institution from 1.1996 till 12.2009 in which UBM ( 35-MHz or 50-MHz) evaluation was available. The UBM results were compared with the histopathological data. Results: From 1.1996 till 12.2009, 146 enucleations were performed in our institution. UBM information was available in 18 cases. There were 8 males and 10 females. The mean age was 4 years old. UBM allowed correct assessement of posterior chamber invasion in 15 cases (13 cases with retinoblastoma in the posterior chamber and 2 cases without retinoblastoma in the posterior chamber). There was a significant correlation between the presence of retinoblastoma cells in the posterior chamber detected by UBM and the histopathological confirmation of posterior chamber involvement (p=0,0008). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity 100%. UBM allowed correct assessment of anterior chamber invasion in 13 cases. The sensitivity of UBM for this purpose was 50% and the specificity 60 %. Conclusions: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the evaluation of the precise extension of the disease. Although our series encompasses only a limited number of cases, the sensitivity and specificity of UBM in the assessment of retinoblastoma anterior extension is interesting. Further prospective multi-centered clinical studies would be necessary to better delineate the utility of this method in the precise categorization of retinoblastoma anterior extension
Resumo:
Purpose: To evaluate the use of high frequency jet ventilation (HFJV) in patients undergoing percutanous thermal ablation procedures.Materials: From may to september 2011 patients with lung, liver or kidney tumors suitable for percutanous thermal ablation were prospectively enrolled to be treated under general anesthesia using HFJV instead of conventional positive pressure ventilation (PPV). Our primary endpoint was feasability of HFJV during percutanous ablation, our secondary endpoints were assessment of breathing related movements by image fusion (CT/US), precision and ease of needle placement by number of CT aquisition/needle reposition and procedure related complications.Results: Twenty-nine patients (21 males, 8 females mean age 66.2 years) with 30 liver tumors, 1 kidney tumors and 6 lung tumors were included. Tumor ablation was performed by radiofrequency (RFA) in 26 cases, microwaves ( MWA) in 2 and cryoablation (CRA) in 1. The ablation procedure could be completed under HFJV in 22 patients. In 2 patients HFVJ had to be stopped in favor of PPV because the tumor was better seen under PPV. HFJV was not performed in 5. Breathing related movements of the target lesion in the cranio-caudal direction as estimated by image fusion were always inferior to 5mm compared to 20mm when patients are under PPV. Needle placement was straightforward under CT as well as US. No patient needed needle repositionning before ablation. We did not observe any HFJV related complications.Conclusions: HFJV significantly reduces breathing movements of target lesion during percutaneous ablation procedures. It does not seem to cause any particular complication. However in some cases such as tumors located at the base of the lungs or in the dome of the liver, the target may be best seen under PPV.