967 resultados para antibody blood level
Resumo:
Three months after a mass vaccination campaign (coverage: 100%) against measles a random seroepidemiological survey was carried out in students aged 1 to 19 years old in the Municipality of Niterói, State of Rio de Janeiro. Blood samples were tested for measles antibodies by enzyme immunosorbent assay (EIA) and negative cases were tested again using hemagglutination inhibition (HI) and plaque reduction neutralization (PRN). Of the 798 samples tested by EIA, 718 (90.2%) were positive for measles antibodies. PRN test was more sensitive than EIA and HI in detecting measles specific antibodies. The total antibody prevalence increased from 90.2% to 93.2% when HI was employed in EIA negative specimens and to 98.9% when PRN was used. After the mass vaccination campaign a marked decrease in measles incidence was observed in the municipality studied, showing the effectiveness of the strategy used for measles control in developing countries.
Resumo:
We describe a case of human T-lymphotropic virus type I associated myelopathy in a 50-year old woman in Nigeria. The patient presented with progressive loss of tone to the two lower limbs and later inability to walk. The HTLV-I antibody presence in the plasma collected from the patient was repeatedly detected by enzyme immunoassays (Abbott HTLV-I EIA and Coulter SELECT-HTLV I/II) and confirmed by Western blot technique. In addition, HTLV-I DNA was amplified from the genomic DNA isolated from the peripheral blood mononuclear cells of the patient by the polymerase chain reaction technique. This finding is significant being the first report of association of HTLV-I with myelopathy in Nigeria.
Resumo:
The relationship between the IgM antibody response, antigenic load as well as the clinical improvement after chemotherapy was studied in order to obtain useful data for the early diagnosis and monitoring leprosy. A level of 82% (94/115) agreement was obtained between IgM UMELISA HANSEN and slitskin smear examination. Discrepant results were observed in 16 patients who showed positive IgM response despite negative by the skin smear examination. In these patients, the IgM response was seen to be associated to the early signal for bacilli recurrence in the skin. In one of these patients the presence of bacilli was demonstrated in the skin, two months after IgM antibodies being detected by UMELISA HANSEN. Also in one of the treated patients positive by both diagnostic techniques, a remarkable decrease in the IgM antibody levels was seen, correlating with a significant clinical improvement. Moreover it was found a direct relationship between the IgM antibody response and bacterial antigenic load, regardless the time elapsed in the disease's evolution.
Resumo:
The determination of aminotranferases levels is very useful in the diagnosis of hepatopathies. In recent years, an elevated serum ALT level in blood donors has been associated with an increased risk of post-transfusion hepatitis (PTH). The purpose of the study was to research the factors associated with elevated ALT levels in a cohort of voluntary blood donors and to evaluate the relationship between increased ALT levels and the development of hepatitis C (HCV) infection. 166 volunteer blood donors with elevated ALT at the time of their first donation were studied. All of the donors were questioned about previous hepatopathies, exposure to hepatitis, exposure to chemicals, use of medication or drugs, sexual behaviour, contact with blood or secretions and their intake of alcohol. Every three months, the serum levels of AST, ALT, alkaline phosphatase, gamma glutamyl transpeptidase, cholesterol, triglyceride and glycemia are assessed over a two year follow-up. The serum thyroid hormone levels as well as the presence of auto-antibodies were also measured. Abdominal ultrasound was performed in all patients with persistently elevated ALT or AST levels. A needle biopsy of liver was performed in 9 donors without definite diagnostic after medical investigation. The presence of anti-HCV antibodies in 116 donors were assayed again the first clinical evaluation. At the end of follow-up period (2 years later) 71 donors were tested again for the presence of anti-HCV antibodies. None of donors resulted positive for hepatitis B or hepatitis C markers during the follow-up. Of the 116 donors, 101 (87%) had persistently elevated ALT serum levels during the follow-up. Obesity and alcoholism were the principal conditions related to elevated ALT serum levels in 91/101 (90.1%) donors. Hypertriglyceridemia, hypercholesterolemia, hypothyroidism and diabetes mellitus also were associated with increased ALT levels. Only 1/101 (0.9%) had mild chronic active non A-G viral hepatitis and 3/101 (2.9%) had liver biopsy with non-specific reactive hepatitis. The determination of ALT levels was not useful to detect donors infected with HCV at donation in Brazil, including the initial seronegative anti-HCV phase.
Resumo:
We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.
Resumo:
The authors studied 70 leprosy patients and 20 normal individuals, comparing the traditional sera collection method and the finger prick blood with the conservation on filter paper for specific antibodies against the native phenolic glycolipid-I (PGL-I) from Mycobacterium leprae. The finger prick blood dried on filter paper was eluated in phosphate buffer saline (PBS) containing 0.5% gelatin. The classical method for native PGL-I was performed for these eluates, and compared with the antibody determination for sera. It was observed that there is a straight correlation comparing these two methods; although the titles found for the eluates were lower than those obtained for serology. This blood collection method could be useful for investigation of new leprosy cases in field, specially in contacts individuals.
Resumo:
Serological survey was performed to detect IgG antibodies anti-Taenia solium metacestodes in blood donors of Hemocentro Regional de Uberlândia, Minas Gerais, Brazil. A total of 1133 sera from blood donors coming from four cities of Triângulo Mineiro area were analyzed by the indirect fluorescence antibody test (IFAT) and the enzyme linked immunosorbent assay (ELISA). Specific IgG antibodies were found in 5.6% of the studied population, showing differences in the positive rates according to their origin: Araguari (13.5%), Tupaciguara (5.0%), Monte Alegre de Minas (4.8%) and Uberlândia (4.7%). The results indicate the probable endemicity of cysticercosis in this population.
Resumo:
A serological survey of Toxoplasma gondii infection in blood donors was carried out in order to identify seroprevalence in Recife, Brazil. Sera from 160 individuals (119 male and 41 female) were evaluated by using a Toxoplasma IgG-antibody enzyme immunoassay (Denka Seiken Co., LTD., Tokyo, Japan). The seropositive percentual for males (79.0%) showed to be higher (p < 0.05) than for females (63.4%). This percentage increases with age, ranging from 18.2% to 92.6% for individuals aging under 20 and 40-50 years old, respectively. For women of childbearing age (18-40 years) it was found a prevalence of 51.6%.
Resumo:
JORNADAS DE ELECTROQUÍMICA E INOVAÇÃO 2013
Resumo:
The aim of the present study was to screen the serum of blood donors, which are apparently healthy and residing in Pondicherry or its neighboring districts of Tamil Nadu State, for specific detection of Cysticercus antigens and antibodies. A total of 216 blood samples were collected from blood donors at the Central Blood Bank, JIPMER Hospital, Pondicherry, India during January and February 2004. Enzyme-linked immunosorbent assay (ELISA) was used to demonstrate anti-Cysticercus antibodies and the Co-agglutination (CoA) was used to detect antigen in sera. 14 (6.48 %) males were positive for either anti-Cysticercus antibodies or antigens. Of these eight sera were positive for anti-Cysticercus antibodies and six were positive for antigens. Results of the present study show that serum Cysticercus antigen detection may be a useful adjunct to antibody testing for seroprevalence studies of cysticercosis in the community. The present study is the first kind of study, carried out to determine both cysticercal antibodies as well as antigens in the serum samples collected from the healthy blood donors.
Resumo:
To describe the epidemiologic profile and prevalence of cardiopathy in 163 Trypanosoma cruzi serum positive blood donor candidates, a descriptive study was carried out between August, 1996 and November, 1997 at the Londrina State University Chagas Disease Outpatient Clinic. The profile found was: young, average age 42.95 ± 8.62 years; male (65%); Caucasian (84%); low level of schooling; low family income; agricultural worker (26%); born in the state of Paraná (67%); from rural areas (85%); migrated to the city (85%); and the vector as the main mechanism of transmission. During the clinical characterization a chronic cardiac form was found in 38% of the patients and classified as cardiac suggestive form in 21% and little suggestive of Chagas disease in 17%. No significant difference was found among age group distribution, sex and the presence of cardiac symptoms in patients with or without cardiopathy. This study emphasizes the importance of expanding medical services to areas with a greater prevalence of infected individuals, in a hierarchical manner and aiming at decentralization.
Resumo:
A cross-sectional study was carried out among 996 volunteer blood donors enrolled from May 1999 to December 1999 to determine the seroprevalence of hepatitis E virus (HEV) infection among volunteer blood donors of the Regional Blood Bank of Londrina, State of Paraná, Brazil, and to evaluate whether the rate of seroprevalence of IgG anti-HEV antibodies is associated with sociodemographic variables and with seropositivity for hepatitis A virus (HAV) infection. All participants answered the questionnaire regarding the sociodemographic characterisitcs. Serum samples were tested for IgG antibodies to HEV (anti-HEV) by an enzyme linked immunoassay (ELISA). All serum samples positive for anti-HEV IgG and 237 serum samples negative for anti-HEV were also assayed for IgG anti-HAV antibodies by ELISA. Anti-HEV IgG was confirmed in 23/996 samples, resulting in a seroprevalence of 2.3% for HEV infection, similar to previous results obtained in developed countries. No significant association was found between the presence of anti-HEV IgG antibodies and the sociodemographic variables including gender, age, educational level, rural or urban areas, source of water, and sewer system (p > 0.05). Also, no association with seropositivity for anti-HAV IgG antibodies was observed (p > 0.05). Although this study revealed a low seroprevalence of HEV infection in the population evaluated, the results showed that this virus is circulating among the population from Londrina, South Brazil, and point out the need of further studies to define the clinical and epidemiological importance of HEV infection and to identify additional risk factors involved in the epidemiology and pathogenesis of this infection in this population.
Resumo:
Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.
Resumo:
An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.