899 resultados para air-lift pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plastic air content is typically tested by the pressure method, ASTM C138. Loss of air content through the paver has been shown to exceed 2 percent at times. Research has shown that early deterioration of pavements in Iowa may be directly or indirectly related to low or inadequate air content. Hardened air content is typically checked using the linear traverse method, ASTM C457. The linear traverse method is very time consuming and could not be used on a production scale. A quick and effective method of testing in place air content is needed. Research has shown a high degree of correlation with the high-pressure method of determining air content of hardened concrete versus plastic air content in laboratory conditions. This research indicated that air contents are more variable when comparing core results to plastic air content, although the overall average for the air content was comparable. Perhaps, the location of the plastic air content test, obtained from construction records, versus location of the cores was not as accurate as needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to adapt a nonlinear model (Wang and Engel - WE) for simulating the phenology of maize (Zea mays L.), and to evaluate this model and a linear one (thermal time), in order to predict developmental stages of a field-grown maize variety. A field experiment, during 2005/2006 and 2006/2007 was conducted in Santa Maria, RS, Brazil, in two growing seasons, with seven sowing dates each. Dates of emergence, silking, and physiological maturity of the maize variety BRS Missões were recorded in six replications in each sowing date. Data collected in 2005/2006 growing season were used to estimate the coefficients of the two models, and data collected in the 2006/2007 growing season were used as independent data set for model evaluations. The nonlinear WE model accurately predicted the date of silking and physiological maturity, and had a lower root mean square error (RMSE) than the linear (thermal time) model. The overall RMSE for silking and physiological maturity was 2.7 and 4.8 days with WE model, and 5.6 and 8.3 days with thermal time model, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

working paper

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The seven members of the FXYD protein family associate with the Na(+)-K(+) pump and modulate its activity. We investigated whether conserved cysteines in FXYD proteins are susceptible to glutathionylation and whether such reactivity affects Na(+)-K(+) pump function in cardiac myocytes and Xenopus oocytes. Glutathionylation was detected by immunoblotting streptavidin precipitate from biotin-GSH loaded cells or by a GSH antibody. Incubation of myocytes with recombinant FXYD proteins resulted in competitive displacement of native FXYD1. Myocyte and Xenopus oocyte pump currents were measured with whole-cell and two-electrode voltage clamp techniques, respectively. Native FXYD1 in myocytes and FXYD1 expressed in oocytes were susceptible to glutathionylation. Mutagenesis identified the specific cysteine in the cytoplasmic terminal that was reactive. Its reactivity was dependent on flanking basic amino acids. We have reported that Na(+)-K(+) pump β(1) subunit glutathionylation induced by oxidative signals causes pump inhibition in a previous study. In the present study, we found that β(1) subunit glutathionylation and pump inhibition could be reversed by exposing myocytes to exogenous wild-type FXYD3. A cysteine-free FXYD3 derivative had no effect. Similar results were obtained with wild-type and mutant FXYD proteins expressed in oocytes. Glutathionylation of the β(1) subunit was increased in myocardium from FXYD1(-/-) mice. In conclusion, there is a dependence of Na(+)-K(+) pump regulation on reactivity of two specifically identified cysteines on separate components of the multimeric Na(+)-K(+) pump complex. By facilitating deglutathionylation of the β(1) subunit, FXYD proteins reverse oxidative inhibition of the Na(+)-K(+) pump and play a dynamic role in its regulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the development response of cultivated rice and red rice to different increases in minimum and maximum daily air temperatures, in Santa Maria, Rio Grande do Sul State, Brazil. One hundred years climate scenarios of temperatures 0, +1, +2, +3, +4, and +5ºC, with symmetric and asymmetric increases in minimum and maximum daily air temperatures were created, using the LARS-WG Weather Generator, and a 1969-2003 database. Nine cultivated rice genotypes (IRGA 421, IRGA 416, IRGA 417, IRGA 420, BRS 7 TAIM, BR-IRGA 409, EPAGRI 109, EEA 406 and a hybrid), and two red rice biotypes (awned black hull-ABHRR, and awned yellow hull-AYHRR) were used. The dates of panicle differentiation (R1), anthesis (R4), and all grains with brown hulls (R9) were estimated with a nonlinear simulation model. Overall, the duration of the emergence-R1 phase decreased, whereas the duration of the R1-R4 and R4-R9 phases most often increased, as temperature increased in the climate change scenarios. The simulated rice development response to elevated temperature was not the same, when the increase in minimum and maximum temperature was symmetric or asymmetric.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les deux mosaïques bien connues des thermes de la villa de Münsingen ont été récemment restaurées et sont aujourd'hui exposées dans le parc d'une fabrique de la commune bernoise. C'est l'occasion de faire le point sur les fouilles entreprises autour du secteur de la découverte depuis 1941, confirmant ainsi l'existence d'une façade de villa de plus de 100 m, bordée par une aile saillante ou une annexe renfermant une zone thermale. Le frigidarium en est constitué d'une pièce d'accès à médaillon central avec tête d'Océan et d'une salle de bains à abside décorée de poissons et de dauphins. L'analyse des motifs amène à repérer au moins trois mains à l'oeuvre sur les pavements, reflétant les tendances de la seconde moitié du IIe siècle et du début du IIIe siècle apr. J.-C. Le maître d'atelier, sans doute installé à Avenches, s'est occupé d'Océan, centrant son discours sur son abondante chevelure d'où sortent deux monstres marins et deux dauphins, allégorie de l'Univers et de l'Empire romain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter describes the profile of the HIA, provides insight into the process and gives an example of how political decisions may be made on behalf of a concerned population through an HIA approach. [Introduction p. 284]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to investigate the effect of low-permeability concrete, made with reduced water‐to‐binder ratios (w/b) and/or supplementary cementitious materials (SCMs), on the need for air entrainment to achieve freezing‐thawing (F‐T) durability. In the present study, concrete mixes were made with different types of cement (Types I and IP), with or without fly ash replacement (15%), with different water‐to‐binder ratios (w/b =0.25, 0.35, 0.45 and 0.55), and with or without air entraining agent (AEA). All concrete mixtures were controlled to have a similar slump by using different dosages of superplasticizer. The rapid chloride permeability and F-T durability of the concrete samples were determined according to ASTM C1202 and ASTM C666A, respectively. The air void structure of the concrete was studied using the Air Void Analyzer, RapidAir, and porosity tests (ASTM C642). In addition, the general concrete properties, such as slump, air content, unit weight, and 28‐day compressive strength, were evaluated. The results indicate that all concrete mixes with proper air entrainment (ASTM C231 air content ≥ 6%) showed good F‐T resistance (durability factor ≥85%). All concrete mixes without AEA showed poor F‐T resistance (durability factor < 40%), except for one mix that had very low permeability and high strength. This was the concrete made with Type IP cement and with a w/b of 0.25, which had a permeability of 520 coulombs and a compressive strength of 12,760 psi (88 MPa). There were clear relationships between the F‐T durability and hardened concrete properties of non–air entrained concrete. However, such relationships did not exist in concrete with AEA. For concrete with AEA, good F‐T durability was associated with an air void spacing factor ≤ 0.28 mm (by AVA) or ≤ 0.22 mm (by RapidAir).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Hidradenitis suppurativa of the groin is a chronic, relapsing inflammatory disease of the skin and subcutaneous tissues. Radical surgical excision is the treatment of choice. Often split-skin grafting or wound healing by secondary intention are used for defect closure, sometimes with disfiguring results. We describe our experience with radical excision of localised inguinal hidradenitis suppurativa and immediate defect closure with a medial thigh lift. PATIENTS AND METHODS: Our hospital database was searched for all patients presenting to our institution for surgical treatment of hidradenitis suppurativa between 2001 and 2006. Only patients with hidradenitis confined to the groin were included. Exclusion criteria were simple abscess incisions, recurrence after previous grafting or flap surgery and extension of the disease outside the groin and presence of clinical signs of infection at the time of surgery. We documented patient demographics, sizes of defects, complications, time of follow-up, recurrences and patient satisfaction. RESULTS: A total of 8 patients with localised inguinal hidradenitis suppurativa were identified and 15 thigh lifts were performed. Defect size assessed on pathologic examination of the excised specimens averaged 15.9 cm x 4.3 cm x 1.3 cm (length x width x depth). All wounds but one healed primarily. Functional and aesthetic results were satisfactory. No major complications and no irritations of the genital area were observed. No recurrences were observed either. CONCLUSION: We propose the medial thigh lift to be considered for immediate defect closure after radical excision of localised inguinal hidradenitis suppurativa provided that no perifocal signs of infection are present after debridement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A health consultation is a verbal or written response from ATSDR or ATSDR’s Cooperative Agreement Partners to a specific request for information about health risks related to a specific site, a chemical release, or the presence of hazardous material. In order to prevent or mitigate exposures, a consultation may lead to specific actions, such as restricting use of or replacing water supplies; intensifying environmental sampling; restricting site access; or removing the contaminated material. In addition, consultations may recommend additional public health actions, such as conducting health surveillance activities to evaluate exposure or trends in adverse health outcomes; conducting biological indicators of exposure studies to assess exposure; and providing health education for health care providers and community members. This concludes the health consultation process for this site, unless additional information is obtained by ATSDR or ATSDR’s Cooperative Agreement Partner which, in the Agency’s opinion, indicates a need to revise or append the conclusions previously issued.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The U.S. Environmental Protection Agency (EPA), the Alcoa – Davenport Works Facility (Alcoa), and concerned citizens and community leaders of Riverdale, Iowa requested the Iowa Department of Public Health (IDPH) Hazardous Waste Site Health Assessment Program to evaluate the health impacts of exposures to volatile organic vapors detected within residences located immediately to the west of the Alcoa property. This health consultation addresses inhalation exposure to individuals that may have occupied the currently vacant residences in which the air sampling was completed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:In January 2011 Spain modified clean air legislation in force since 2006, removing all existing exceptions applicable to hospitality venues. Although this legal reform was backed by all political parties with parliamentary representation, the government's initiative was contested by the tobacco industry and its allies in the hospitality industry. One of the most voiced arguments against the reform was its potentially disruptive effect on the revenue of hospitality venues. This paper evaluates the impact of this reform on household expenditure at restaurants and bars and cafeterias. Methods and empirical strategy:We use micro-data from the Encuesta de Presupuestos Familiares (EPF) for years 2006 to 2012 to estimate "two part" models where the probability of observing a positive expenditure and, for those who spend, the expected level of expenditure are functions of an array of explanatory variables. We apply a before-after analysis with a wide range of controls for confounding factors and a flexible modeling of time effects.Results:In line with the majority of studies that analyze the effects of smoking bans using objective data, our results suggest that the reform did not cause reductions in households' expenditures on restaurant services or on bars and cafeteria services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To test the validity of a simple, rapid, field-adapted, portable hand-held impedancemeter (HHI) for the estimation of lean body mass (LBM) and percentage body fat (%BF) in African women, and to develop specific predictive equations. DESIGN: Cross-sectional observational study. SETTINGS: Dakar, the capital city of Senegal, West Africa. SUBJECTS: A total sample of 146 women volunteered. Their mean age was of 31.0 y (s.d. 9.1), weight 60.9 kg (s.d. 13.1) and BMI 22.6 kg/m(2) (s.d. 4.5). METHODS: Body composition values estimated by HHI were compared to those measured by whole body densitometry performed by air displacement plethysmography (ADP). The specific density of LBM in black subjects was taken into account for the calculation of %BF from body density. RESULTS: : Estimations from HHI showed a large bias (mean difference) of 5.6 kg LBM (P<10(-4)) and -8.8 %BF (P<10(-4)) and errors (s.d. of the bias) of 2.6 kg LBM and 3.7 %BF. In order to correct for the bias, specific predictive equations were developed. With the HHI result as a single predictor, error values were of 1.9 kg LBM and 3.7 %BF in the prediction group (n=100), and of 2.2 kg LBM and 3.6 %BF in the cross-validation group (n=46). Addition of anthropometrical predictors was not necessary. CONCLUSIONS: The HHI analyser significantly overestimated LBM and underestimated %BF in African women. After correction for the bias, the body compartments could easily be estimated in African women by using the HHI result in an appropriate prediction equation with a good precision. It remains to be seen whether a combination of arm and leg impedancemetry in order to take into account lower limbs would further improve the prediction of body composition in Africans.