979 resultados para air pollution control
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
"This seminar publication contains materials prepared for the U.S. Environmental Protection Agency Technology Transfer Program and presented at industrial pollution-control seminars for the textile industry. This publication was coordinated by the Institute of Textile Technology, Charlottesville, Va."
Resumo:
Prepared by Raytheon Company, Equipment Division, Air Traffic Control Directorate, under contract DOT-FA 76WA-3738.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
"May 1995."--Cover.
Resumo:
This thesis is concerned with various aspects of Air Pollution due to smell, the impact it has on communities exposed to it, the means by which it may be controlled and the manner in which a local authority may investigate the problems it causes. The approach is a practical one drawing on examples occurring within a Local Authority's experience and for that reason the research is anecdotal and is not a comprehensive treatise on the full range of options available. Odour Pollution is not yet a well organised discipline and might be considered esoteric as it is necessary to incorporate elements of science and the humanities. It has been necessary to range widely across a number of aspects of the subject so that discussion is often restricted but many references have been included to enable a reader to pursue a particular point in greater depth. In a `fuzzy' subject there is often a yawning gap separating theory and practice, thus case studies have been used to illustrate the interplay of various disciplines in resolution of a problem. The essence of any science is observation and measurement. Observation has been made of the spread of odour pollution through a community and also of relevant meterological data so that a mathematical model could be constructed and its predictions checked. It has been used to explore the results of some options for odour control. Measurements of odour perception and human behaviour seldom have the precision and accuracy of the physical sciences. However methods of social research enabled individual perception of odour pollution to be quantified and an insight gained into reaction of a community exposed to it. Odours have four attributes that can be measured and together provide a complete description of its perception. No objective techniques of measurement have yet been developed but in this thesis simple, structured procedures of subjective assessment have been improvised and their use enabled the functioning of the components of an odour control system to be assessed. Such data enabled the action of the system to be communicated using terms that are understood by a non specialist audience.
Resumo:
Exhaust emissions from diesel engines are a substantial source of air pollution in this country. In recognition of this fact, the Environmental Protection Agency has issued strict new regulations due to take effect -in 1991 and 1994 that will drastically reduce the amount of some pollutants these engines will be allowed to emit. The technology is not currently available to produce diesel engines that can meet these regulations without large penalties in engine performance and efficiency. One technique that offers promise of being able to reduce emissions from both existing engines and new engines is alcohol fumigation.
Resumo:
The objective of the research project was to seek acceptable solutions to the air pollution problem created in the asphalt recycling process using modified conventional equipment.
Resumo:
Poor hospital indoor air quality (IAQ) may lead to hospital-acquired infections, sick hospital syndrome and various occupational hazards. Air-control measures are crucial for reducing dissemination of airborne biological particles in hospitals. The objective of this study was to perform a survey of bioaerosol quality in different sites in a Portuguese Hospital, namely the operating theater (OT), the emergency service (ES) and the surgical ward (SW). Aerobic mesophilic bacterial counts (BCs) and fungal load (FL) were assessed by impaction directly onto tryptic soy agar and malt extract agar supplemented with antibiotic chloramphenicol (0.05%) plates, respectively using a MAS-100 air sampler. The ES revealed the highest airborne microbial concentrations (BC range 240-736 CFU/m(3) CFU/m(3); FL range 27-933 CFU/m(3)), exceeding, at several sampling sites, conformity criteria defined in national legislation [6]. Bacterial concentrations in the SW (BC range 99-495 CFU/m(3)) and the OT (BC range 12-170 CFU/m(3)) were under recommended criteria. While fungal levels were below 1 CFU/m(3) in the OT, in the SW (range 1-32 CFU/m(3)), there existed a site with fungal indoor concentrations higher than those detected outdoors. Airborne Gram-positive cocci were the most frequent phenotype (88%) detected from the measured bacterial population in all indoor environments. Staphylococcus (51%) and Micrococcus (37%) were dominant among the bacterial genera identified in the present study. Concerning indoor fungal characterization, the prevalent genera were Penicillium (41%) and Aspergillus (24%). Regular monitoring is essential for assessing air control efficiency and for detecting irregular introduction of airborne particles via clothing of visitors and medical staff or carriage by personal and medical materials. Furthermore, microbiological survey data should be used to clearly define specific air quality guidelines for controlled environments in hospital settings.
Resumo:
The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.
Resumo:
Fluoride (F) is an air pollutant that causes phytotoxicity. Besides the importance of this, losses of agricultural crops in the vicinity of F polluting industries in Brazil have been recently reported. Injuries caused to plant leaf cell structures by excess F are not well characterized. However, this may contribute to understanding the ways in which plant physiological and biochemical processes are altered. A study evaluated the effects of the atmospheric F on leaf characteristics and growth of young trees of sweet orange and coffee exposed to low (0.04 mol L(-1)) or high (0.16 mol L(-1)) doses of HF nebulized in closed chamber for 28 days plus a control treatment not exposed. Gladiolus and ryegrass were used as bioindicators in the experiment to monitor F exposure levels. Fluoride concentration and dry mass of leaves were evaluated. Leaf anatomy was observed under light and electron microscopy. High F concentrations (similar to 180 mg kg(-1)) were found in leaves of plants exposed at the highest dose of HF. Visual symptoms of F toxicity in leaves of citrus and coffee were observed. Analyses of plant tissue provided evidence that F caused degeneration of cell wall and cytoplasm and disorganization of bundle sheath, which were more evident in Gladiolus and coffee. Minor changes were observed for sweet orange and ryegrass. Increase on individual stomatal area was also marked for the Gladiolus and coffee, and which were characterized by occurrence of opened ostioles. The increased F absorption by leaves and changes at the structural and ultrastructural level of leaf tissues correlated with reduced plant growth.
Resumo:
Objective: To review the epidemiological evidence for the association between passive smoking and lung cancer. Method: Primary studies and meta-analyses examining the relationship between passive smoking and lung cancer were identified through a computerised literature search of Medline and Embase, secondary references, and experts in the field of passive smoking. Primary studies meeting the inclusion criteria were meta-analysed. Results From 1981 to the end of 1999 there have been 76 primary epidemiological studies of passive smoking and lung cancer, and 20 meta-analyses. There were 43 primary studies that met the inclusion criteria for this meta-analysis; more studies than previous assessments. The pooled relative risk (RR) for never-smoking women exposed to environmental tobacco smoke (ETS) from spouses, compared with unexposed never-smoking women was 1.29 (95% CI 1.17-1.43). Sequential cumulative meta-analysed results for each year from 1981 were calculated: since 1992 the RR has been greater than 1.25. For Western industrialised countries the RR for never-smoking women exposed to ETS compared with unexposed never-smoking women, was 1.21 (95% CI 1.10-1.33). Previously published international spousal meta-analyses have all produced statistically significant RRs greater than 1.17. Conclusions The abundance of evidence in this paper, and the consistency of findings across domestic and workplace primary studies, dosimetric extrapolations and meta-analyses, clearly indicates that non-smokers exposed to ETS are at increased risk of lung cancer. Implications: The recommended public health policy is for a total ban on smoking in enclosed public places and work sites.
Resumo:
The impact of particle emissions by biomass burning is increasing throughout the world. We explored the toxicity of particulate matter produced by sugar cane burning and compared these effects with equivalent mass of traffic-derived particles. For this purpose, BALB/c mice received a single intranasal instillation of either distilled water (C) or total suspended particles (15 mu g) from an urban area (SP group) or biomass burning-derived particles (Bio group). Lung mechanical parameters (total, resistive and viscoelastic pressures, static elastance, and elastic component of viscoelasticity) and histology were analyzed 24h after instillation. Trace elements and polycyclic aromatic hydrocarbons (PAHs) metabolites of the two sources of particles were determined. All mechanical parameters increased similarly in both pollution groups compared with control, except airway resistive pressure, which increased only in Bio. Both exposed groups showed significantly higher fraction area of alveolar collapse, and influx of polymorphonuclear cells in lung parenchyma than C. The composition analysis of total suspended particles showed higher concentrations of PAHs and lower concentration of metals in traffic than in biomass burning-derived particles. In conclusion, we demonstrated that a single low dose of ambient particles, produced by traffic and sugar cane burning, induced significant alterations in pulmonary mechanics and lung histology in mice. Parenchymal changes were similar after exposure to both particle sources, whereas airway mechanics was more affected by biomass-derived particles. Our results indicate that biomass particles were at least as toxic as those produced by traffic. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
Several epidemiological studies have linked particulate matter exposure to numerous adverse health effects on the respiratory, cardiovascular, and reproductive systems (Braga et al., 1999; Zanobetti et al., 2000; Anderson et al., 2001; Farhat et al., 2005). More recently, ambient levels of black carbon were associated to impaired cognitive function in children (Suglia et al., 2008), suggesting that the central nervous system (CNS) may be a target of air pollutants. The present study was conducted to (a) determine whether chronic residual oil fly ash (ROFA) exposure promotes behavioral changes and lipid peroxidation in rat brain areas, and (b) determine whether N-acetylcysteine (NAC), a general antioxidant, prevents these effects. Forty-five-day-old male Wistar rats were exposed or not to ROFA by intranasal instillation and were treated or not with NAC (150 mg/kg) ip for 30 days. One day later, rats were submitted to the open field test to evaluate the motor/exploratory activities and emotionality followed by decapitation. Striatum and cerebellum were dissected to determine lipid peroxidation by the accumulation of thiobarbituric acid-reactive substances (TBARS). ROFA instillation induced an increase in lipid peroxidation level in striatum (p = .033) and cerebellum (p = .030), as compared with the control group. NAC treatment blocked these changes. ROFA promoted a decrease in the frequency of peripheral walking (p = .006) and a decrease in exploration (p = .001), which were not blocked by N-acetylcysteine. The present study provides evidence that toxic particles, administered by the respiratory route, induce oxidative stress in structures of the central nervous system, as well as behavioral alterations. The administration of NAC reduces lipid peroxidation at the striatum and cerebellum levels, but does not influence behavioral disturbances.