987 resultados para Valvular prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien? XT stent-valve implantation through the fibrotic thin akinetic apical wall.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0 degrees to 150 degrees of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90 degrees of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 2-kilogram child had a pacemaker implanted by a subxyphoid approach with the generator located under the rectus sheath. Days later, the battery eroded the abdominal wall and the peritoneum. The whole system was removed and a new one was implanted inside the pericardium on an emergent basis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The femoral periprosthetic fracture of the knee is one of the most feared complications because of its repercussions. Incidence are more and more likely due to the increase of total implanted arthroplasty of the knee, due to the increasing lifespan among the general population. The objective of this study is to analyze some of the perioperative aspects of the treatment of these fractures, comparing the use of osteosynthesis with plates and the retrograde nailing in those patients with femoral periprosthetic knee fractures with a stable implant. MATERIAL AND METODS: The study retrospectively examines 18 cases treated consecutively in our hospital (3 men and 15 women, average age of 72.7 years) between the years of 2000 and 2009. All fractures were located in the distal femur and on a stable implant. Eight were treated through retrograde nailing (Group I) and ten with plates (Group II). The cases are analyzed through the tests of the University of Mann-Withney and the exact Fischer test, with significant values of p≤0.05, the variables of median hospital stay, necessity of transfusion indicated with values of hemoglobin less than 8 mg/ml, preoperative radiological alignment and postoperative alignment of the total knee prosthesis (TKR), measured following the anatomical tibiofemoral axis, time of consolidation and incidence of localized complications in both groups. RESULTS: We did not find any statistically significant differences between the two groups in any of the variables analyzed. Localized complications are more frequent in Group I (62.5 percent of patients) than in Group II (10 percent of patients). The need for transfusion is greater in Group II (40 percent) than in Group I (12.5 percent). CONCLUSIONS: The type of implant used in treatment of femoral periprosthetic knee fracture does not significantly influence perioperative factors. The treatment for this type of fractures should be individually chosen in relation to the type of fracture, characteristics of the patient and stability and prosthesis model of the primary knee.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trans-apical aortic valve replacement (AVR) is a new and rapidly growing therapy. However, there are only few training opportunities. The objective of our work is to build an appropriate artificial model of the heart that can replace the use of animals for surgical training in trans-apical AVR procedures. To reduce the necessity for fluoroscopy, we pursued the goal of building a translucent model of the heart that has nature-like dimensions. A simplified 3D model of a human heart with its aortic root was created in silico using the SolidWorks Computer-Aided Design (CAD) program. This heart model was printed using a rapid prototyping system developed by the Fab@Home project and dip-coated two times with dispersion silicone. The translucency of the heart model allows the perception of the deployment area of the valved-stent without using heavy imaging support. The final model was then placed in a human manikin for surgical training on trans-apical AVR procedure. Trans-apical AVR with all the necessary steps (puncture, wiring, catheterization, ballooning etc.) can be realized repeatedly in this setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Assess the degree of satisfaction in a series of patients between 50 and 60 years of age who underwent surgery in our unicompartmental prosthesis unit (UPU) for monocompartmental gonarthrosis. Likewise, the definition based on current literature is assessed, as well as our experience in the indications, inconveniences and results of the internal knee unicompartmental arthroplasty discussed with supra-tuberosity tibial osteotomy, which was the common surgical option in these cases.MATERIAL AND METHOD: This study included 19 patients between 50 and 60 years of age (average age 56.7 years) (Interval of 51-60 years) intervened between 7/2007 and 11/2011 by the same surgeon (GDFB). Functional assessment used the Oxford Knee Score (OKS) questionnaire. A bibliographic search was performed in the MEDLINE, COCHRANE and EMBASE databases from 1988 to 2012. RESULTS: With an average follow-up of 29.4 months, 16 of 19 patients stated that they were satisfied with the results obtained and would repeat the intervention. One patient sufered a prosthetic infection and was reviewed for total knee replacement with good results. CONCLUSIONS: the medial, unicompartmental arthroplasty of the knee is a valid surgical option and reproducible in the medium term treatment of monocompartmental gonarthrosis in patients between 50 and 60 years of age.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We carried out a descriptive, retrospective study with a sample side of 121 patients with Legión® prosthesis replacement in our Vírgen del Rocío hospital area, in the city of Seville, from May of 2008 until March of 2011. This study included epidemiological data as well as technical information about the process performed, including post-operative pain, mobility and functional results using a functional assessment scale and series of radiological studies. Average follow-up was 19 months, with a mean age of 71 years and 87% women. We obtained an average of 20.41º for articular balance obtained, correction of prior deformities by restoring the tibia-femoral axis to the anatomic e balance articular angle; we resolved bone loss prior to replacement and carried out an adequate balance of the inter-lineal joint. 66% of the patients continued with no post-operative pain, with the other 33% reporting slight to moderate pain. With regards to pain at the point of the stem, we have found no significant relationship with the incidence angle of the stem on the cortical or with the type of cement. We observed a 74% rate of intervention without complications, with complications being rupture of the patellar tendon in one patient, one case of peri-prosthesis fracture, two iatrogenic avulsion fractures of the anterior tibial tuberosity and seven infections (4 were diagnosed previously).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Evaluate the results obtained in the simultaneous replacement of a septic arthroplasty or a second septic replacement (implanting the prosthesis in a contaminated eld). Material and method: Series of 17 cases, with a mean age of 66.8 years and average follow-up of 49 months. The exclusion criteria were serious immunological depression and unknown germ or not sensitive to at least three antibiotics. After the intervention, the corresponding antibiotics were administered between six weeks and three months. Recovery was established as the normality for infection indicator variables at least nine months after the replacement. Results: 14 patients developed towards total recovery (follow-up at least 9 months and maximum 84 months). 3 cases presented relapse, all three carriers of Staphylococcus epidermidis (at 1, 3 and 7 months of follow-up respectively). The success percentage is 82.41% (average follow-up of 49 months). Conclusions: Simultaneous replacements is an interesting option for patients with plural pathologies as it o"ers a single operation, less morbidity, quicker return to activities to restore normal function and less associated costs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Popliteal pseudoaneurysm is a rare but important complication of knee arthroplasties. To our knowledge, this complication has not been reported previously in the literature after unicompartmental knee arthroplasty. Apart from intraoperatively caused arterial injuries, obese patients and other previous cardiovascular diseases may be potential factors of risks for pseudoaneurysm in knee surgeries. As it is an uncommon complication and it has inconspicuous symptoms, both diagnosis and treatment can be delayed. This means that a high level of suspicion is necessary to prevent serious complications derived from pseudoaneurysms. LEVEL OF EVIDENCE Level IV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The optimum treatment for prosthetic joint infections has not been clearly defined. We report our experience of the management of acute haematogenous prosthetic joint infection (AHPJI) in patients during a 3-year prospective study in nine Spanish hospitals. Fifty patients, of whom 30 (60%) were female, with a median age of 76 years, were diagnosed with AHPJI. The median infection-free period following joint replacement was 4.9 years. Symptoms were acute in all cases. A distant previous infection and/or bacteraemia were identified in 48%. The aetiology was as follows: Staphylococcus aureus, 19; Streptococcus spp., 14; Gram-negative bacilli, 12; anaerobes, two; and mixed infections, three. Thirty-four (68%) patients were treated with a conservative surgical approach (CSA) with implant retention, and 16 had prosthesis removal. At 2-year follow-up, 24 (48%) were cured, seven (14%) had relapsed, seven (14%) had died, five (10%) had persistent infection, five had re-infection, and two had an unknown evolution. Overall, the treatment failure rates were 57.8% in staphylococcal infections and 14.3% in streptococcal infections. There were no failures in patients with Gram-negative bacillary. By multivariate analysis, CSA was the only factor independently associated with treatment failure (OR 11.6; 95% CI 1.29-104.8). We were unable to identify any factors predicting treatment failure in CSA patients, although a Gram-negative bacillary aetiology was a protective factor. These data suggest that although conservative surgery was the only factor independently associated with treatment failure, it could be the first therapeutic choice for the management of Gram-negative bacillary and streptococcal AHPJI, and for some cases with acute S. aureus infections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: In patients with lateral osteoarthritis of the knee, use of external unicompartmental knee arthroplasty it is a well known surgical alternative, used by the minor trauma involved, short hospital stay and rapid recovery. The purpose of this study is to show the clinical outcomes to short-medium term of patients undergoing this procedure. Methods: we describe the technique used and the peculiarities of the prosthesis (A Mobile-bearing lateral unicompartmental knee replacement, Oxford Domed ®). This is an observational retrospective longitudinal study, of 15 arthroplasties performed in 13 women and 2 men, between 2010 and 2013, with a mean age of 60’7 years, with a diagnosis of lateral osteoarthritis of the knee, without involvement of the medial or patellofemoral compartment and cruciate ligaments functionally intact, with a mean follow up of 25 months. All patients complete the Oxford Knee Score and Visual Analog Scale (VAS) during the study. Results: The results are favorable, with an improvement of 6.60 points on the EVA, 3.73 for 1 in the postoperatory funcionality, the OKS very satisfactory with an average of 38 points over 50 and without any postoperative function surgical revision. Anserine tendinitis was observed in 20% of cases. Conclusions: The benefits of this surgery against their alternatives are assessed, and their potential drawbacks. External unicompartmental knee arthroplasty is an effective alternative in cases of knee osteoarthritis of the lateral compartment with no other associated injuries.