990 resultados para Tropospheric Aerosols
Resumo:
Each year, approximately five million people die worldwide from putatively vaccine-preventable mucosally transmitted diseases. With respect to mass vaccination campaigns, one strategy to cope with this formidable challenge is aerosol vaccine delivery, which offers potential safety, logistical, and cost-saving advantages over traditional vaccination routes. Additionally, aerosol vaccination may elicit pivotal mucosal immune responses that could contain or eliminate mucosally transmitted pathogens in a preventative or therapeutic vaccine context. In this current preclinical non-human primate investigation, we demonstrate the feasibility of aerosol vaccination with the recombinant poxvirus-based vaccine vectors NYVAC and MVA. Real-time in vivo scintigraphy experiments with radiolabeled, aerosol-administered NYVAC-C (Clade C, HIV-1 vaccine) and MVA-HPV vaccines revealed consistent mucosal delivery to the respiratory tract. Furthermore, aerosol delivery of the vaccines was safe, inducing no vaccine-associated pathology, in particular in the brain and lungs, and was immunogenic. Administration of a DNA-C/NYVAC-C prime/boost regime resulted in both systemic and anal-genital HIV-specific immune responses that were still detectable 5 months after immunization. Thus, aerosol vaccination with NYVAC and MVA vectored vaccines constitutes a tool for large-scale vaccine efforts against mucosally transmitted pathogens.
Resumo:
L'utilisation massive d'antibiotiques dans les établissements de santé participe à la sélection des souches bactériennes résistantes aux antibiotiques. Ces bactéries ainsi que les résidus d'antibiotiques se retrouvent dans les effluents des hôpitaux et atteignent les stations d'épuration communales, où elles ne sont pas systématiquement éliminées par le processus de traitement des eaux. La dissémination d'antibiotiques et de souches résistantes dans l'environnement naturel peut avoir des conséquences non négligeables en termes de santé publique et de perturbations écologiques. En Europe, il semble qu'actuellement très peu d'hôpitaux traitent leurs effluents, mais ceci devrait se généraliser à l'avenir. Le but de cette revue est de faire un état des lieux et une synthèse des études ayant mesuré la présence d'antibiotiques et de bactéries résistantes aux antibiotiques dans les eaux de sorties des hôpitaux et d'évaluer les risques potentiels liés à la dissémination aéroportée (bioaérosols) de ces bactéries dans l'environnement direct de l'hôpital. [Auteure]
Resumo:
Previous studies have demonstrated that poultry house workers are exposed to very high levels of organic dust and consequently have an increased prevalence of adverse respiratory symptoms. However, the influence of the age of broilers on bioaerosol concentrations has not been investigated. To evaluate the evolution of bioaerosol concentration during the fattening period, bioaerosol parameters (inhalable dust, endotoxin and bacteria) were measured in 12 poultry confinement buildings in Switzerland, at three different stages of the birds' growth; samples of air taken from within the breathing zones of individual poultry house employees as they caught the chickens ready to be transported for slaughter were also analysed. Quantitative polymerase chain reaction (Q-PCR) was used to assess the quantity of total airborne bacteria and total airborne Staphylococcus species. Bioaerosol levels increased significantly during the fattening period of the chickens. During the task of catching mature birds, the mean inhalable dust concentration for a worker was 26 +/- 1.9 mg m(-3) and endotoxin concentration was 6198 +/- 2.3 EU m(-3) air, >6-fold higher than the Swiss occupational recommended value (1000 EU m(-3)). The mean exposure level of bird catchers to total bacteria and Staphylococcus species measured by Q-PCR is also very high, respectively, reaching values of 53 (+/-2.6) x 10(7) cells m(-3) air and 62 (+/-1.9) x 10(6) m(-3) air. It was concluded that in the absence of wearing protective breathing apparatus, chicken catchers in Switzerland risk exposure beyond recommended limits for all measured bioaerosol parameters. Moreover, the use of Q-PCR to estimate total and specific numbers of airborne bacteria is a promising tool for evaluating any modifications intended to improve the safety of current working practices
Resumo:
Une mauvaise hygiène des mains peut représenter une perte économique importante pour les industries alimentaires ou les industries pharmaceutiques et constitue un gros problème de santé publique dans les établissements de soins. En effet, le risque de transmission manuportée de pathogènes d'un patient à l'autre via le personnel soignant est un problème récurrent dans tous les hôpitaux. C'est pourquoi, une hygiène irréprochable des mains du personnel soignant est une composante fondamentale de lutte contre les infections nosocomiales. En comparaison avec les autres techniques de séchage des mains, l'utilisation d'une serviette en papier à usage unique semble être la méthode la plus efficace pour éliminer les bactéries. En effet, les autres méthodes de séchage, utilisant des appareils à air chaud ou froid, peuvent générer un air contaminé ou remettre en suspension les germes restés sur la peau, facilitant ainsi leur dispersion et leur inhalation. C'est pourquoi, l'OMS a émis des recommandations déconseillant les sèche-mains électriques en milieu hospitalier au profit des serviettes en papiers. Cependant, ces serviettes à usage unique ne sont pas stériles et peuvent elles-mêmes déposer des germes, généralement non pathogènes, sur les mains lors du séchage. Le but du premier article analysé est d'évaluer le niveau de contamination de ces serviettes, ainsi que la possibilité de dépôt de ces bactéries présentes sur les serviettes, sur les mains. À côté du risque de propagation de pathogènes par contact direct, la contamination microbiologique par voie aérienne via les aérosols existe aussi. Pour éviter d'être contaminé par des personnes excrétrices de micro-organismes transmissibles par aérosols (tuberculose, grippe, grippe aviaire SRAS...), il faut porter des protections respiratoires de type FFP2 (1) (norme européenne équivalente à la norme anglosaxonne N95). Ces protections respiratoires ou masques filtrants (en formes de bec de canard) peuvent être portées théoriquement pendant 4 heures. Le but de l'étude du second article est d'évaluer le risque de remise en suspension dans l'air de particules virales présentes sur la face extérieure d'un masque de protection respiratoire lors de simulation d'épisodes de toux provenant du porteur de cette protection.
Resumo:
Q fever is a zoonosis caused by an intracellular Gram-negative bacteria, Coxiella burnetii. Animals are the main reservoir and transmission to men generally is occurring by inhalation of contaminated aerosols. Acute Q fever generally is benign and usually resolves spontaneously. When symptomatic, the clinical presentation typically includes one of the following three syndromes: a flu-like illness, a granulomatous hepatitis or an atypical pneumonia. Individuals presenting risk factors such as patients with valvular heart diseases and vascular prostheses, as well as pregnant women and immuno-suppressed patients represent a population at risk of chronic infection, with endocarditis as the most common clinical form.
Resumo:
Waterproofing agents are widely used to protect leather and textiles in both domestic and occupational activities. An outbreak of acute respiratory syndrome following exposure to waterproofing sprays occurred during the winter 2002-2003 in Switzerland. About 180 cases were reported by the Swiss Toxicological Information Centre between October 2002 and March 2003, whereas fewer than 10 cases per year had been recorded previously. The reported cases involved three brands of sprays containing a common waterproofing mixture, that had undergone a formulation change in the months preceding the outbreak. A retrospective analysis was undertaken in collaboration with the Swiss Toxicological Information Centre and the Swiss Registries for Interstitial and Orphan Lung Diseases to clarify the circumstances and possible causes of the observed health effects. Individual exposure data were generated with questionnaires and experimental emission measurements. The collected data was used to conduct numeric simulation for 102 cases of exposure. A classical two-zone model was used to assess the aerosol dispersion in the near- and far-field during spraying. The resulting assessed dose and exposure levels obtained were spread on large scales, of several orders of magnitude. No dose-response relationship was found between exposure indicators and health effects indicators (perceived severity and clinical indicators). Weak relationships were found between unspecific inflammatory response indicators (leukocytes, C-reactive protein) and the maximal exposure concentration. The results obtained disclose a high interindividual response variability and suggest that some indirect mechanism(s) predominates in the respiratory disease occurrence. Furthermore, no threshold could be found to define a safe level of exposure. These findings suggest that the improvement of environmental exposure conditions during spraying alone does not constitute a sufficient measure to prevent future outbreaks of waterproofing spray toxicity. More efficient preventive measures are needed prior to the marketing and distribution of new waterproofing agents.
Resumo:
OBJECTIVES: Agriculture is considered one of the occupations most at risk of acute or chronic respiratory problems. The aim of our study was to determine from which level of exposure to organic dust the respiratory function is chronically affected in workers involved in wheat grain or straw manipulation and to test if some of these working populations can recover their respiratory function after an exposure decrease. METHOD: 87 workers exposed to wheat dust: farmers, harvesters, silo workers and livestock farmers and 62 non exposed workers, were included into a longitudinal study comprising two visits at a six months interval with lung function measurements and symptom questionnaires. Cumulative and mean exposure to wheat dust were generated from detailed work history of each worker and a task-exposure matrix based on task-specific exposure measurements. Immunoglobulins (IgG and IgE) specific of the most frequent microorganisms in wheat dust have been determined. RESULTS: FEV1 decreased significantly with the cumulative exposure and mean exposure levels. The estimated decrease was close to 200 mL per year of high exposure, which corresponds roughly to levels of wheat dust higher than 10 mg/m(3). Peak expiratory flow and several acute symptoms correlate with recent exposure level. Recovery of the respiratory function six months after exposure to wheat dust and evolution of exposure indicators in workers blood (IgG and IgE) will be discussed. CONCLUSIONS: These results show a chronic effect of exposure to wheat dust on bronchial obstruction. Short term effects and reversibility will be assessed using the full study results.
Resumo:
Exposure to PM10 and PM2.5 (particulate matter with aerodynamic diameter smaller than 10 μm and 2.5 μm, respectively) is associated with a range of adverse health effects, including cancer, pulmonary and cardiovascular diseases. Surface characteristics (chemical reactivity, surface area) are considered of prime importance to understand the mechanisms which lead to harmful effects. A hypothetical mechanism to explain these adverse effects is the ability of components (organics, metal ions) adsorbed on these particles to generate Reactive Oxygen Species (ROS), and thereby to cause oxidative stress in biological systems (Donaldson et al., 2003). ROS can attack almost any cellular structure, like DNA or cellular membrane, leading to the formation of a wide variety of degradation products which can be used as a biomarker of oxidative stress. The aim of the present research project is to test whether there is a correlation between the exposure to Diesel Exhaust Particulate (DEP) and the oxidative stress status. For that purpose, a survey has been conducted in real occupational situations where workers were exposed to DEP (bus depots). Different exposure variables have been considered: - particulate number, size distribution and surface area (SMPS); - particulate mass - PM2.5 and PM4 (gravimetry); - elemental and organic carbon (coulometry); - total adsorbed heavy metals - iron, copper, manganese (atomic adsorption); - surface functional groups present on aerosols (Knudsen flow reactor). Several biomarkers of oxidative stress (8-hydroxy-2'-deoxyguanosine and several aldehydes) have been determined either in urine or serum of volunteers. Results obtained during the sampling campaign in several bus depots indicated that the occupational exposure to particulates in these places was rather low (40-50 μg/m3 for PM4). Bimodal size distributions were generally observed (5 μm and <1 μm). Surface characteristics of PM4 varied strongly, depending on the bus depot. They were usually characterized by high carbonyl and low acidic sites content. Among the different biomarkers which have been analyzed within the framework of this study, mean urinary levels of 8-hydroxy-2'-deoxyguanosine increased significantly (p<0.05) during two consecutive days of exposure for non-smoker workers. On the other hand, no statistically significant differences were observed for serum levels of hexanal, nonanal and 4- hydroxy-nonenal (p>0.05). Biomarkers levels will be compared to exposure variables to gain a better understanding of the relation between the particulate characteristics and the formation of ROS by-products. This project is financed by the Swiss State Secretariat for Education and Research. It is conducted within the framework of the COST Action 633 "Particulate Matter - Properties Related to Health Effects".
Resumo:
The aim of this work is to study the tropospheric ozone concentrations and daily peak cycles in the Lisbon MetropolitanArea (LMA) during the summer season (June, July and August, JJA) covering the 4-yr study period 2002-2005. Theresults show that all the stations have the same pattern: a minimum in the early morning followed by an increase at 1000UTC reaching to a peak at 1300-1400 UTC, dropped again to minimum values 1800 UTC but with different concentrationsdue to regional and local wind circulations and complex dynamic interactions. We identified in Lisbon city the ozone “weekendeffect”. Finally, we studied an episode of very high levels of tropospheric ozone and related daily ozone concentrationswith some meteorological variables.
Resumo:
Previous studies have demonstrated that poultry-house workers are exposed to very high levels of organic dust and consequently have an increased prevalence of adverse respiratory symptoms. However, the influence of the age of broilers, on bioaerosol concentrations has not been investigated. To evaluate the evolution of bioaerosol concentration during the fattening period, bioaerosol parameters (inhalable dust, endotoxin and bacteria) were measured in 12 poultry confinement buildings in Switzerland, at 3 different stages of the birds' growth; Samples of air taken from within the breathing zones of individual poultry-house employees as they caught the chickens ready to be transported for slaughter, were also analysed. Quantitative PCR (Q-PCR) was used to assess the quantity of total airborne bacteria and total airborne Staphylococcus species. Bioaerosol levels increased significantly during the fattening period of the chickens. During the task of catching mature birds, the mean inhalable dust concentration for a worker was 31 ± 4.7 mg/m3, and endotoxin concentration was 11'080 ± 3436 UE/m3 air, more than ten-fold higher than the Swiss occupational recommended value (1000 UE/m3). The mean exposure level of bird catchers to total bacteria and Staphylococcus species measured by Q-PCR is also very high, respectively reaching values of 72 (± 11) x107 cells/m3 air and 70 (± 16) x106/m3 air. It was concluded that in the absence of wearing protective breathing apparatus, chicken catchers in Switzerland risk exposure beyond recommended limits for all measured bioaerosol parameters. Moreover, the use of Q-PCR to estimate total and specific numbers of airborne bacteria is a promising tool for evaluating any modifications intended to improve the safety of current working practices.
Resumo:
The complex chemical and physical nature of combustion and secondary organic aerosols (SOAs) in general precludes the complete characterization of both bulk and interfacial components. The bulk composition reveals the history of the growth process and therefore the source region, whereas the interface controls--to a large extent--the interaction with gases, biological membranes, and solid supports. We summarize the development of a soft interrogation technique, using heterogeneous chemistry, for the interfacial functional groups of selected probe gases [N(CH(3))(3), NH(2)OH, CF(3)COOH, HCl, O(3), NO(2)] of different reactivity. The technique reveals the identity and density of surface functional groups. Examples include acidic and basic sites, olefinic and polycyclic aromatic hydrocarbon (PAH) sites, and partially and completely oxidized surface sites. We report on the surface composition and oxidation states of laboratory-generated aerosols and of aerosols sampled in several bus depots. In the latter case, the biomarker 8-hydroxy-2'-deoxyguanosine, signaling oxidative stress caused by aerosol exposure, was isolated. The increase in biomarker levels over a working day is correlated with the surface density N(i)(O3) of olefinic and/or PAH sites obtained from O(3) uptakes as well as with the initial uptake coefficient, γ(0), of five probe gases used in the field. This correlation with γ(0) suggests the idea of competing pathways occurring at the interface of the aerosol particles between the generation of reactive oxygen species (ROS) responsible for oxidative stress and cellular antioxidants.
Resumo:
The natural dissipation rates of sidestream smoke (SS) particles dispersed in a chamber were studied from the standpoint of a static atmosphere and were expressed as half-lives of residence in the air. The half-lives for particles less than 0.3 micron, 0.3-0.5 micron and 0.5-1 micron were found to be 25.5, 12.8 and 4.9 h, respectively. Total particulate matter (TPM) decreases by half after 6.2 h. Other data on diluted SS in the indoor air were also reported.
Resumo:
Introduction. Preclinical and clinical evidences for a role of oral probiotics in the management of allergic diseases are emerging. Aim. We aimed at testing the immunomodulatory effects of intranasal versus intragastric administration of Lactobacillus paracasei NCC2461 in a mouse model of allergic airway inflammation and the specificity of different probiotics by comparing L. paracasei NCC2461 to Lactobacillus plantarum NCC1107. Methods. L. paracasei NCC2461 or L. plantarum NCC1107 strains were administered either intragastrically (NCC2461) or intranasally (NCC2461 or NCC1107) to OVA-sensitized mice challenged with OVA aerosols. Inflammatory cell recruitment into BALF, eotaxin and IL-5 production in the lungs were measured. Results. Intranasal L. paracasei NCC2461 efficiently protected sensitized mice upon exposure to OVA aerosols in a dose-dependent manner as compared to control mice. Inflammatory cell number, eotaxin and IL-5 were significantly reduced in BALF. Intranasal supplementation of L. paracasei NCC2461 was more potent than intragastric application in limiting the allergic response and possibly linked to an increase in T regulatory cells in the lungs. Finally, intranasal L. plantarum NCC1107 reduced total and eosinophilic lung inflammation, but increased neutrophilia and macrophages infiltration. Conclusion. A concerted selection of intervention schedule, doses, and administration routes (intranasal versus intragastric) may markedly contribute to modulate airway inflammation in a probiotic strain-specific manner.
Resumo:
Aerosolien vaikutusta säteilynkulkuun ilmakehässä tutkitaan muun muassa niiden ilmastonmuutokseen vaikuttavien ominaisuuksien sekä erilaisten maanpuolustukseen liittyvien sovellusten vuoksi. Tässä työssä keskityttiin aerosolien aiheuttamaan infrapunasäteilyn vaimenemiseen horisontaalisella polulla. Mitattuja vaimennuksen arvoja verrattiin mallinnettuihin ja etsittiin syitä niiden välisiin eroihin. Työn alussa tutustuttiin aerosolien tyypillisiin ominaisuuksiin sekä säteilyn ja aerosolien väliseen vuorovaikutukseen. Tämän jälkeen esiteltiin mittauksissa käytetyt laitteet sekä mallinnuksessa käytetty ohjelmisto ja tiedonkäsittely. Työssä tutkittiin mitattujen ja mallinnettujen aerosolivaimennuskertoimien käyttäytymistä eri sääpametrien (näkyvyys, suhteellinen kosteus ja lämpötila) suhteen. Tutkimuksessa tarkasteltiin myös mitattuja kokojakaumia ja niitä verrattiin mallinnuksessa käytettyihin. Mittalaitteiden epävarmuuksien ja käyttökelpoisten mittaustulosten vähyyden johdosta täyttä varmuutta mittauksien tarkkuudesta ei saavutettu. Mittausten epävarmuudesta huolimatta kävi ilmi, että mitatut kokojakaumat eivät täysin vastaa mallin käyttämiä kokojakaumia. Tulevaisuudessa mittauksia pitää jatkaa, jotta tiedon analysointiin saadaan tarpeeksi kelvollisia mittaustuloksia ja mittalaitteiden luotettavuus selviää.