921 resultados para Three-phase line analysis
Resumo:
Bending fatigue tests were carried out to clarify the effects of heat treatment parameters: temperature and time after cadmium electroplating on a high strength steel, to avoid hydrogen embrittlement. Temperatures heat of 190 degrees C, 230 degrees C, 250 degrees C and 300 degrees C at 3, 8 and 24 hours together with the base material electroplated, with and without heat treatment, resulted in 14 conditions studied with respect to fatigue behaviour. Statistical data analysis was performed to identify the best combination temperature/time regarding fatigue strength of the ABNT 4340 steel and the results obtained revealed that the fatigue strength depend on temperature/time conditions.
Resumo:
The present study was designed to determine the optimum dietary zinc supplementation to Nile tilapia juveniles (13.3 +/- 1.13 g), by using vegetable-based diets supplemented with increasing levels of zinc from commercial-grade zinc sulfate monohydrate, a previously determined zinc source of higher bioavailability. The basal diet was supplemented with 25, 50, 100, 150, 200, 300, or 400 mg/kg Zn. The experiment was conducted in forty 250-l tanks arranged in a recirculating water system. The experimental period was divided in two phases. For the first 10-week experimental phase, fish were fed satiation diets supplemented with increasing levels of zinc. For the second 5-week experimental phase, fish that were fed diets supplemented with 0-300 mg/kg Zn during the first phase were fed the 400 mg/kg Zn-supplemented diet; fish fed the diet supplemented with 400 mg/kg Zn (first phase) were fed the nonzinc-supplemented diet (second phase). Broken-line analysis showed that the optimum dietary zinc supplementation ((ZnSO4H2O)-H-.) to Nile tilapia juveniles, using weight gain and bone zinc saturation as response criteria, was 44.50 and 79.51 mg/kg Zn, respectively. When challenged by a zinc-deficient diet, tilapia mobilized stored bone zinc to preserve its zinc status. By considering that bone zinc saturation is a more accurate response criterion than weight gain, it was concluded that the optimum dietary zinc supplementation ((ZnSO4H2O)-H-.) in vegetable-based diets to Nile tilapia juveniles is 79.51 mg/kg Zn. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to determine the role of head, eye and arm movements during the execution of a table tennis forehand stroke. Three-dimensional kinematic analysis of line-of-gaze, arm and ball was used to describe visual and motor behaviour. Skilled and less skilled participants returned the ball to cued right or left target areas under three levels of temporal constraint: pre-, early- and late-cue conditions. In the pre- and early-cue conditions, both high and low skill participants tracked the ball early in flight and kept gaze stable on a location in advance of the ball before ball-bat contact. Skilled participants demonstrated an earlier onset of ball tracking and recorded higher performance accuracy than less skilled counterparts. The manipulation of cue condition showed the limits of adaptation to maintain accuracy on the target. Participants were able to accommodate the constraints imposed by the early-cue condition by using a shorter quiet eye duration, earlier quiet eye offset and reduced arm velocity at contact. In the late-cue condition, modifications to gaze, head and arm movements were not sufficient to preserve accuracy. The findings highlight the functional coupling between perception and action during time-constrained, goal-directed actions.
Resumo:
Three procedures (line transect, point intercept and quadrat) for estimating abundance of macroscopic components of periphyton (macroalgae and bryophytes) were compared in two bedrock streams from southeastern Brazil on the basis of frequency and percent cover. In addition, two quadrat sizes (25 and 50 cm) were tested for best size. Samplings were all made within a 10 m length stream reach. Differences were tested by means of analysis of variance, ANOVA - one way, Student's t test and Chi-square test, whereas associations among them were evaluated by Pearson's r correlation coefficient. Values of frequency and percent cover varied among the different techniques and periphyton species in both sites but ANOVA, t and Chi-square tests revealed no significant difference (p<0.05) for percent cover in the two sites. No consistent pattern was observed for the different procedures between sites. Values for quadrat (25 and 50 cm) percent cover were positively correlated among distinct periphyton species. Significant differences for frequency were found in only one site. Quadrats of 50 cm produced the highest frequency values, whereas point intercept the lowest in both sites. In terms of spatial variation within the stream segment, significant differences were generally observed among all procedures, except between quadrats. As a rule, highly significant correlations for percent cover were found among the different techniques along the stream reach. The strongest relationships were found for quadrats with the other procedures, whereas the weakest between Line and point. Pros and cons of the three techniques are fully discussed.
Resumo:
Comparative genomic hybridization (CGH) analysis was performed for the identification of chromosomal imbalances in two benign gynecomastias and one malignant breast carcinoma derived from patients with male breast disease and compared with cytogenetic analysis in two of the three cases. CGH analysis demonstrated overrepresentation of 8q in all three cases. One case of gynecomastia presented gain of 1p34.3similar topter. 11p14similar toq12. and 17p11.2similar toqter, and loss of 1q41similar toqter and 4q33similar toqter. The other gynecomastia presented del(1)(q41) as detected by both cytogenetic and CGH analysis. CGH analysis of the invasive ductal carcinoma confirmed a gain of 17p11.2similar toqter previously detected by cytogenetic analysis. These regions showed some similarity in their pattern of imbalance to the chromosomal alterations described in female and male breast cancer. (C) 2002 Elsevier B.V. All rights reserved.
Resumo:
This paper presents an improved analysis of a novel Programmable Power-factor-corrected-Based Hybrid Multipulse Power Rectifier (PFC-HMPR) for utility interface of power electronic converters. The proposed hybrid multipulse rectifier is composed of an ordinary three-phase six-pulse diode-bridge rectifier (Graetz bridge) with a parallel connection of single-phase switched converters in each three-phase rectifier leg. In this paper, the authors present a complete discussion about the controlled rectifiers' power contribution and also a complete analysis concerning the total harmonic distortion of current that can be achieved when the proposed converter operates as a conventional 12-pulse rectifier. The mathematical analysis presented in this paper corroborate, with detailed equations, the experimental results of two 6-kW prototypes implemented in a laboratory.
Resumo:
The neutral wire in most power flow software is usually merged into phase wires using Kron's reduction. Since the neutral wire and the ground are not explicitly represented, neutral wire and ground currents and voltages remain unknown. In some applications, like power quality and safety analyses, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of special interest. In this paper, a general power flow algorithm for three-phase four-wire radial distribution networks, considering neutral grounding, based on backward-forward technique, is proposed. In this novel use of the technique, both the neutral wire and ground are explicitly represented. A problem of three-phase distribution system with earth return, as a special case of a four-wire network, is also elucidated. Results obtained from several case studies using medium- and low-voltage test feeders with unbalanced load, are presented and discussed.
Resumo:
The objective of this paper is to show an alternative methodology to estimate per unit length parameters of a line segment of a transmission line. With this methodology the line segment parameters can be obtained starting from the phase currents and -voltages in receiving and sending end of the line segment. If the line segment is represented as being one or more pi circuits whose frequency dependent parameters are considered lumped, its impedance and admittance can be easily expressed as functions of the currents and voltages at the sending and receiving end. Because we are supposing that voltages and currents at the sending and receiving end of the tine segment (in frequency domain) are known, it is possible to obtains its impedance and admittance and consequently its per unit length longitudinal and transversal parameters. The procedure will be applied to estimate the longitudinal and transversal parameters of a small segment of a single-phase line that is already built.
Resumo:
This paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which. justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results.
Resumo:
Three-dimensional kinematic analysis of line of gaze, arm and ball was used to describe the visual and motor behaviour of male adolescents diagnosed with attention deficit hyperactivity disorder (ADHD). The ADHD participants were tested when both on (ADHD-On) and off (ADHD-Off) their medication and compared to age-matched normal controls in a modified table tennis task that required tracking the ball and hitting to cued right and left targets. Long-duration information was provided by a pre-cue, in which the target was illuminated approximately 2 s before the serve, and short-duration information by an early-cue illuminated about 350 ms after the serve, leaving -500 ms to select the target and perform the action. The ADHD groups differed significantly from the control group in both the pre-cue and early-cue conditions in being less accurate, in having a later onset and duration of pursuit tracking, and a higher frequency of gaze on and off the ball. The use of medication significantly reduced the gaze frequency of the ADHD participants, but surprisingly this did not lead to an increase in pursuit tracking, suggesting a barrier was reached beyond which ball flight information could not be processed. The control and ADHD groups did not differ in arm movement onset, duration and velocity in the short-duration early-cue condition; in the long-duration pre-cue condition, however, the ADHD group's movement time onset and arm velocity differed significantly from controls. The results show that the ADHD groups were able to process short-duration information without experiencing adverse effects on their motor behaviour; however, long-duration information contributed to irregular movement control.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
There is controversy over how hormonal conditions influence cerebral physiology. We studied pattern-shift visual evoked potentials (PS-VEP), brain stem auditory evoked potentials (BAEP) and short-latency somatosensory evoked potentials (SSEV) in 20 female volunteers at different phases of the menstrual cycle (estrogen phase, ovulatory day and progesterone phase). Statistical analysis showed decreased latencies for P 100 (PS-VEP), N 19and P 22 (SSEV) waves in the progesterone phase compared with the estrogen phase. There was no significant difference between the estrogen and the ovulation day values. Comparing the three above stages, there were no significant differences in the brainstem auditory evoked potentials. The reduction of the latencies of the potentials generated in multisynaptic circuits provides the first consistent neurophysiological basis for a tentative comprehension of human pre-menstrual syndrome.
Resumo:
For a typical non-symmetrical system with two parallel three phase transmission lines, modal transformation is applied using some examples of single real transformation matrices. These examples are applied searching an adequate single real transformation matrix to two parallel three phase transmission line systems. The analyses are started with the eigenvector and eigenvalue studies, using Clarke's transformation or linear combinations of Clarke's elements. The Z C and parameters are analyzed for the case that presents the smallest errors between the exact eigenvalues and the single real transformation matrix application results. The single real transformation determined for this case is based on Clarke's matrix and its main characteristic is the use of a unique homopolar reference. So, the homopolar mode becomes a connector mode between the two three-phase circuits of the analyzed system. ©2005 IEEE.
Resumo:
In this paper it is proposed a novel hybrid three-phase rectifier capable to achieve high input power factor (PF), and low total harmonic distortion in the input currents (THDI). The proposed hybrid high power rectifier is composed by a standard three-phase 6-pulses diode rectifier (Graetz bridge) with a parallel connection of single-phase Boost rectifiers in each three-phase rectifier leg. Such topology results in a structure capable of programming the input current waveform and providing conditions for obtaining high input power factor and low harmonic current distortion. In order to validate the proposed hybrid rectifier, this paper describes its principles of operation, with detailed experimental results and discussions on power rating of the required Boost converters as related to the desired total harmonic current distortion. It is demonstrated that only a fraction of the output power is processed through the Boost converters, making the proposed solution economically viable for very high power installations, with fast pay back of the investment. Moreover, retrofitting to existing installations is also feasible since the parallel path can be easily controlled by integration with the existing de-link. A prototype rated at 6 kW has been implemented in laboratory and fully demonstrated its operation, performance and feasibility to high power applications. © 2005 IEEE.
Resumo:
This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.