892 resultados para Thin-wall


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnetic properties of BaFe12O19 and BaFe10.2Sn0.74Co0.66O19 single crystals have been investigated in the temperature range (1.8 to 320 K) with a varying field from -5 to +5 T applied parallel and perpendicular to the c axis. Low-temperature magnetic relaxation, which is ascribed to the domain-wall motion, was performed between 1.8 and 15 K. The relaxation of magnetization exhibits a linear dependence on logarithmic time. The magnetic viscosity extracted from the relaxation data, decreases linearly as temperature goes down, which may correspond to the thermal depinning of domain walls. Below 2.5 K, the viscosity begins to deviate from the linear dependence on temperature, tending to be temperature independent. The near temperature independence of viscosity suggests the existence of quantum tunneling of antiferromagnetic domain wall in this temperature range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conversion electron Mossbauer spectra of composition modulated FeSi thin films have been analysed within the framework of a quasi shape independent model in which the distribution function for the hyperfine fields is assumed to be given by a binomial distribution. Both the hyperfine field and the hyperfine field distribution depend on the modulation characteristic length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the applicability of posterior wall repair with a synthetic absorbable mesh. Between January and September 1996, five posterior repairs using absorbable synthetic meshes were performed. Five posterior wall repairs in patients matched for age, parity, and rectocele degree were performed according to usual procedures during the same period, and were used as controls. No febrile morbidity, cuff or posterior vaginal wall infections, thrombophlebitis, rectal injury, or hemorrhagic complications were observed in the 10 women who entered the study. In summary, posterior wall repair can be easily performed with an absorbable soft tissue patch, theoretically preserving sexual activity, and probably offers better functional results with longer experience, thus providing a safe and useful procedure in sexually active women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In thin-layer electrodeposition the dissipated electrical energy leads to a substantial heating of the ion solution. We measured the resulting temperature field by means of an infrared camera. The properties of the temperature field correspond closely with the development of the concentration field. In particular, we find that the thermal gradients at the electrodes act similar to a weak additional driving force to the convection rolls driven by concentration gradients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The time course of atherosclerosis burden in distinct vascular territories remains poorly understood. We longitudinally evaluated the natural history of atherosclerotic progression in two different arterial territories using high spatial resolution magnetic resonance imaging (HR-MRI), a powerful, safe, and non-invasive tool. METHODS AND RESULTS: We prospectively studied a cohort of 30 patients (mean age 68.3, n = 9 females) with high Framingham general cardiovascular disease 10-year risk score (29.5%) and standard medical therapy with mild-to-moderate atherosclerosis intra-individually at the level of both carotid and femoral arteries. A total of 178 HR-MRI studies of carotid and femoral arteries performed at baseline and at 1- and 2-year follow-up were evaluated in consensus reading by two experienced readers for lumen area (LA), total vessel area (TVA), vessel wall area (VWA = TVA - LA), and normalized wall area index (NWI = VWA/TVA). At the carotid level, LA decreased (-3.19%/year, P = 0.018), VWA increased (+3.83%/year, P = 0.019), and TVA remained unchanged. At the femoral level, LA remained unchanged, VWA and TVA increased (+5.23%/year and +3.11%/year, both P < 0.01), and NWI increased for both carotid and femoral arteries (+2.28%/year, P = 0.01, and +1.8%/year, P = 0.033). CONCLUSION: The atherosclerotic burden increased significantly in both carotid and femoral arteries. However, carotid plaque progression was associated with negative remodelling, whereas the increase in femoral plaque burden was compensated by positive remodelling. This finding could be related to anatomic and flow differences and/or to the distinct degree of obstruction in the two arterial territories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using atomic force microscopy we have studied the nanomechanical response to nanoindentations of surfaces of highly oriented molecular organic thin films (thickness¿1000¿nm). The Young¿s modulus E can be estimated from the elastic deformation using Hertzian mechanics. For the quasi-one-dimensional metal tetrathiafulvalene tetracyanoquinodimethane E~20¿GPa and for the ¿ phase of the p-nitrophenyl nitronyl nitroxide radical E~2GPa. Above a few GPa, the surfaces deform plastically as evidenced by discrete discontinuities in the indentation curves associated to molecular layers being expelled by the penetrating tip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the dynamics of the late stages of the Fréedericksz transition in which a periodic transient pattern decays to a final homogeneous state. A stability analysis of an unstable stationary pattern is presented, and equations for the evolution of the domain walls are obtained. Using results of previous theories, we analyze the effect that the specific dynamics of the problem, incorporating hydrodynamic couplings, has on the expected logarithmic domain growth law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrodeposition experiments conducted in a thin-layer horizontal cell containing a nonbinary aqueous electrolyte prepared with cupric sulfate and sodium sulfate gave rise to fingerlike deposits, a novel and unexpected growth mode in this context. Both the leading instability from which fingers emerge and some distinctive features of their steady evolution are interpreted in terms of a simple model based on the existing theory of fingering in fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study discusses the effect of iron doping in TiO2 thin films deposited by rf sputtering. Iron doping induces a structural transformation from anatase to rutile and electrical measurements indicate that iron acts as an acceptor impurity. Thermoelectric power measurement shows a transition between n-type and p-type electrical conduction for an iron concentration around 0.13 at.%. The highest p-type conductivity at room temperature achieved by iron doping was 10(-6) S m(-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Chest wall resection and reconstruction can be performed with minimal mortality and excellent functional and cosmetic results using synthetic meshes, methylmethacrylate, or other substitutes. However, these techniques are less easily applicable if chest wall resections have to be performed for infections. METHODS: We report a novel technique for this purpose using a modified latissimus dorsi flap harvested in continuity with the thoracolumbar fascia. The vascularized fascia was sutured into the chest wall defect, providing a stable base for the muscular component of the flap. Three patients requiring large full-thickness resections of the anterolateral chest wall for chronic infections were treated accordingly, two presenting with chronic radionecrosis and osteomyelitis and one with chest wall invasion by pulmonary aspergillosis. RESULTS: There were no intraoperative or postoperative complications and immediate extubation was possible in all 3 patients without the need for postoperative ventilation or tracheotomy. Healing of the infected chest wall was observed in all 3 patients. Postoperative cinemagnetic resonance imaging revealed concordant movements of the replaced segments without evidence of paradoxical motion during inspiration and expiration. CONCLUSIONS: This technique is easy and safe. It allows a stable and satisfactory reconstruction after large anterolateral full-thickness chest wall resections of infected, previously irradiated tissues, using only well-vascularized autologous tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this study was to evaluate associations between aortic pulse wave velocity (PWV) and aortic and carotid vessel wall thickness (VWT) using cardiovascular magnetic resonance imaging (MRI) in patients with hypertension as compared with healthy adult volunteers. MATERIALS AND METHODS: Local medical ethics approval was obtained and the participants gave informed consent. Fifteen patients with hypertension (5 men and 10 women; mean [SD] age, 49 [14] years) and 15 age- and sex-matched healthy volunteers were prospectively included and compared. All participants underwent MRI examination for measuring aortic and carotid VWT and aortic PWV with well-validated MRI techniques at 1.5- and 3-T MRI systems: PWV was assessed from velocity-encoded MRI and VWT was assessed by using dual-inversion black-blood gradient-echo imaging techniques. Paired t tests were used for testing differences between the volunteers and the patients and Pearson correlation (r) and univariable and multivariable stepwise linear regression analyses were used to test associations between aortic and carotid arterial wall thickness and stiffness. RESULTS: Mean values for aortic PWV and aortic and carotid VWT (indexed for body surface area [BSA]) were all significantly higher in patients with hypertension as compared with the healthy volunteers (ie, aortic PWV, 7.0 ± 1.4 m/s vs 5.7 ± 1.3 m/s; aortic VWT/BSA, 0.12 ± 0.03 mL/m vs 0.10 ± 0.03 mL/m; carotid VWT/BSA, 0.04 ± 0.01 mL/m vs 0.03 ± 0.01 mL/m; all P < 0.01). Aortic PWV was highly correlated with aortic VWT/BSA (r = 0.76 and P = 0.002 in the patients vs r = 0.63 and P = 0.02 in the volunteers), and in the patients, aortic PWV was moderately correlated with carotid VWT/BSA (r = 0.50; P = 0.04). In the volunteers, correlation between aortic PWV and carotid VWT/BSA was not significant (r = 0.40; P = 0.13). In addition, aortic VWT/BSA was significantly correlated with carotid VWT/BSA, in both the patients (r = 0.60; P = 0.005) and volunteers (r = 0.57; P = 0.007). CONCLUSIONS: In the patients with hypertension and the healthy volunteers, the aortic PWV is associated more strongly with aortic wall thickness than with carotid wall thickness, reflecting site-specific coupling between vascular wall thickness and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Dual-inversion recovery (DIR) is widely used for magnetic resonance vessel wall imaging. However, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. Therefore, an extension of phase-sensitive (PS) DIR is proposed for carotid vessel wall imaging. METHODS: The statistical distribution of the phase signal after DIR is probed to segment carotid lumens and suppress their residual blood signal. The proposed PS-DIR technique was characterized over a broad range of inversion times. Multislice imaging was then implemented by interleaving the acquisition of 3 slices after DIR. Quantitative evaluation was then performed in healthy adult subjects and compared with conventional DIR imaging. RESULTS: Single-slice PS-DIR provided effective blood-signal suppression over a wide range of inversion times, enhancing wall-lumen contrast and vessel wall conspicuity for carotid arteries. Multislice PS-DIR imaging with effective blood-signal suppression is enabled. CONCLUSIONS: A variant of the PS-DIR method has successfully been implemented and tested for carotid vessel wall imaging. This technique removes timing constraints related to inversion recovery, enhances wall-lumen contrast, and enables a 3-fold increase in volumetric coverage at no extra cost in scanning time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Examination report on the City of Wall Lake, Iowa for the period July 1, 2012 through June 30, 2013