965 resultados para Splenic artery aneurysm
Resumo:
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
Resumo:
We describe a simple method to achieve both hemostasis and stabilization of the left anterior descending coronary artery during minimally invasive coronary artery bypass grafting. This technique allows the surgeon to perform a precise anastomosis of the left internal mammary artery to the target vessel on a beating heart.
Resumo:
Instead of standard rigid thoracoscopes, we used a modified gastroscope for video assistance during 12 minimally invasive left internal mammary harvesting. Flexibility and remote control of its last centimeters give to the gastroscope a total freedom of movements, and perfect positioning in every direction. The scope is equipped with cold light, a suction canal and an irrigation canal, which allow for in situ washing without needing to remove it from the thoracic cavity. Thanks to these advantages, vision and lighting are always perfect.
Resumo:
OBJECTIVES: The goal was to test 2 hypotheses: first, that coronary endothelial function can be measured noninvasively and abnormal function detected using clinical 3.0-T magnetic resonance imaging (MRI); and second, that the extent of local coronary artery disease (CAD), in a given patient, is related to the degree of local abnormal coronary endothelial function. BACKGROUND: Abnormal endothelial function mediates the initiation and progression of atherosclerosis and predicts cardiovascular events. However, direct measures of coronary endothelial function have required invasive assessment. METHODS: The MRI was performed in 20 healthy adults and 17 patients with CAD. Cross-sectional coronary area and blood flow were quantified before and during isometric handgrip exercise, an endothelial-dependent stressor. In 10 severe, single-vessel CAD patients, paired endothelial function was measured in the artery with severe stenosis and the contralateral artery with minimal disease. RESULTS: In healthy adults, coronary arteries dilated and flow increased with stress. In CAD patients, coronary artery area and blood flow decreased with stress (both p </= 0.02). In the paired study, coronary artery area and blood flow failed to increase during exercise in the mildly diseased vessel, but both area (p = 0.01) and blood flow (p = 0.02) decreased significantly in the severely diseased, contralateral artery. CONCLUSIONS: Endothelial-dependent coronary artery dilation and increased blood flow in healthy subjects, and their absence in CAD patients, can now be directly visualized and quantified noninvasively. Local coronary endothelial function differs between severely and mildly diseased arteries in a given CAD patient. This novel, safe method may offer new insights regarding the importance of local coronary endothelial function and improved risk stratification in patients at risk for and with known CAD.
Resumo:
Morphological descriptors are practical and essential biomarkers for diagnosis andtreatment selection for intracranial aneurysm management according to the current guidelinesin use. Nevertheless, relatively little work has been dedicated to improve the three-dimensionalquanti cation of aneurysmal morphology, automate the analysis, and hence reduce the inherentintra- and inter-observer variability of manual analysis. In this paper we propose a methodologyfor the automated isolation and morphological quanti cation of saccular intracranial aneurysmsbased on a 3D representation of the vascular anatomy.
Resumo:
This paper presents a technique to estimate and model patient-specific pulsatility of cerebral aneurysms over onecardiac cycle, using 3D rotational X-ray angiography (3DRA) acquisitions. Aneurysm pulsation is modeled as a time varying-spline tensor field representing the deformation applied to a reference volume image, thus producing the instantaneousmorphology at each time point in the cardiac cycle. The estimated deformation is obtained by matching multiple simulated projections of the deforming volume to their corresponding original projections. A weighting scheme is introduced to account for the relevance of each original projection for the selected time point. The wide coverage of the projections, together with the weighting scheme, ensures motion consistency in all directions. The technique has been tested on digital and physical phantoms that are realistic and clinically relevant in terms of geometry, pulsation and imaging conditions. Results from digital phantomexperiments demonstrate that the proposed technique is able to recover subvoxel pulsation with an error lower than 10% of the maximum pulsation in most cases. The experiments with the physical phantom allowed demonstrating the feasibility of pulsation estimation as well as identifying different pulsation regions under clinical conditions.
Resumo:
OBJECTIVE: Absent or reverse end-diastolic flow (Doppler II/III) in umbilical artery is correlated with poor perinatal outcome, particularly in intrauterine growth restricted (IUGR) fetuses. The optimal timing of delivery is still controversial. We studied the short- and long-term morbidity and mortality among these children associated with our defined management. STUDY DESIGN: Sixty-nine IUGR fetuses with umbilical Doppler II/III were divided into three groups; Group 1, severe early IUGR, no therapeutic intervention (n = 7); Group 2, fetuses with pathological biophysical profile, immediate delivery (n = 35); Group 3, fetuses for which expectant management had been decided (n = 27). RESULTS: In Group 1, stillbirth was observed after a mean delay of 6.3 days. Group 2 delivered at an average of 31.6 weeks and two died in the neonatal period (6%). In Group 3 after a mean delay of 8 days, average gestational age at delivery was 31.7 weeks; two intra uterine and four perinatal deaths were observed (22%). Long-term follow-up revealed no sequelae in 25/31 (81%) and 15/18 (83%), and major handicap occurred in 1 (3%) and 2 patients (11%), respectively, for Groups 2 and 3. CONCLUSION: Fetal mortality was observed in 22% of this high risk group. After a mean period of follow-up of 5 years, 82% of infants showed no sequelae. According to our management, IUGR associated with umbilical Doppler II or III does not show any benefit from an expectant management in term of long-term morbidity.
Resumo:
OBJECTIVE: Our aim is to evaluate the feasibility, efficacy, and patency of using coronary stents for the treatment of hepatic artery stenosis after liver transplantation. CONCLUSION: Hepatic artery stenosis after liver transplantation can be treated using coronary stents. The low rate of complication, high technical success, and 1-year patency rates are encouraging.
Resumo:
AIMS: To estimate physical activity trajectories for people who quit smoking, and compare them to what would have been expected had smoking continued. DESIGN, SETTING AND PARTICIPANTS: A total of 5115 participants in the Coronary Artery Risk Development in Young Adults Study (CARDIA) study, a population-based study of African American and European American people recruited at age 18-30 years in 1985/6 and followed over 25 years. MEASUREMENTS: Physical activity was self-reported during clinical examinations at baseline (1985/6) and at years 2, 5, 7, 10, 15, 20 and 25 (2010/11); smoking status was reported each year (at examinations or by telephone, and imputed where missing). We used mixed linear models to estimate trajectories of physical activity under varying smoking conditions, with adjustment for participant characteristics and secular trends. FINDINGS: We found significant interactions by race/sex (P = 0.02 for the interaction with cumulative years of smoking), hence we investigated the subgroups separately. Increasing years of smoking were associated with a decline in physical activity in black and white women and black men [e.g. coefficient for 10 years of smoking: -0.14; 95% confidence interval (CI) = -0.20 to -0.07, P < 0.001 for white women]. An increase in physical activity was associated with years since smoking cessation in white men (coefficient 0.06; 95% CI = 0 to 0.13, P = 0.05). The physical activity trajectory for people who quit diverged progressively towards higher physical activity from the expected trajectory had smoking continued. For example, physical activity was 34% higher (95% CI = 18 to 52%; P < 0.001) for white women 10 years after stopping compared with continuing smoking for those 10 years (P = 0.21 for race/sex differences). CONCLUSIONS: Smokers who quit have progressively higher levels of physical activity in the years after quitting compared with continuing smokers.
Resumo:
Splenic marginal zone lymphoma (SMZL) is an indolent B-cell lymphoproliferative disorder characterised by 7q32 deletion, but the target genes of this deletion remain unknown. In order to elucidate the genetic target of this deletion, we performed an integrative analysis of the genetic, epigenetic, transcriptomic and miRNomic data. High resolution array comparative genomic hybridization of 56 cases of SMZL delineated a minimally deleted region (2.8 Mb) at 7q32, but showed no evidence of any cryptic homozygous deletion or recurrent breakpoint in this region. Integrated transcriptomic analysis confirmed significant under-expression of a number of genes in this region in cases of SMZL with deletion, several of which showed hypermethylation. In addition, a cluster of 8 miRNA in this region showed under-expression in cases with the deletion, and three (miR-182/96/183) were also significantly under-expressed (P<0.05) in SMZL relative to other lymphomas. Genomic sequencing of these miRNA and IRF5, a strong candidate gene, did not show any evidence of somatic mutation in SMZL. These observations provide valuable guidance for further characterisation of 7q deletion.
Resumo:
Objective: Non-operative management (NOM) of blunt splenic injuries (BSI) is nowadays considered the standard treatment. The study aimed to determine the criteria applied for NOM and to identify risk factors for its failure. Methods: Review of all adult patients with BSI treated at the University Hospital Bern, Switzerland, between 2000 and 2008. Results: There were 206 patients (146 men, 70·9%) with a mean age of 38·2 ± 19·1 years and an Injury Severity Score of 30·9 ± 11·6. The American Association for the Surgery of Trauma classification of the splenic injury was: grade I, n=43 (20·9%); grade II, n=52 (25·2%); grade III, n=60 (29·1%); grade IV, n=42 (20·4%) and grade V, n=9 (4·4%). 47 patients (22·8%) required immediate surgery. Five or more units of red cell transfusions (P<0·001), Glasgow Coma Scale<11 (P=0·009) and age ≥55 years (P=0·038) were associated with primary operative management (OM). 159 patients (77·2%) qualified for NOM, which was successful in 89·9% (143/159). The overall splenic salvage rate was 69·4% (143/206). Multivariate analysis found age ≥40 years to be the only factor independently related to the failure of NOM (P=0·001). Conclusion: Advanced age is associated with an increased failure rate ofNOM in patients with BSI.
Resumo:
AIM: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. PATIENTS, METHODS: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curves and independent predictors were determined by Cox multivariate analyses. RESULTS: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 +/- 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p < 0.0001), followed by history of CAD (Hazard Ratio (HR) = 15.9; p = 0.0001), diabetic retinopathy (HR = 10.0; p = 0.001) and inability to exercise (HR = 7.7; p = 0.02). Patients with normal MPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. CONCLUSION: Diabetic patients with normal MPI had an excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a >5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients.
Resumo:
The treatment of craniocervical instability caused by diverse conditions remains challenging. Different techniques have been described to stabilize the craniocervical junction. The authors present 2 cases in which tumoral destruction of the C-1 lateral mass caused craniocervical instability. A one-stage occipitoaxial spinal interarticular stabilization (OASIS) technique with titanium cages and posterior occipitocervical instrumentation was used to reconstruct the C-1 lateral mass and stabilize the craniocervical junction. The ipsilateral vertebral artery was preserved. The OASIS technique offers single-stage tumor resection, C-1 lateral mass reconstruction, and stabilization with a loadsharing construct. It could be an option in the treatment of select cases of C-1 lateral mass failure.