920 resultados para Sleep Rebound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to validate the use of a mandibular repositioner appliance (MRA) to treat obstructive sleep apnea (OSA) and primary snoring, comparing polysomnographic and Epworth Sleepiness Scale (ESS) data obtained prior to and during MRA treatment. Materials and Methods: Sixty-three patients who presented with different degrees of OSA severity or primary snoring were fitted to a PM positioner between 2009 and 2011. The diagnosis was established by a polysomnogram (PSG) prior to treatment and after 6 months to verify the efficacy of MRA therapy. Subjective daytime sleepiness was evaluated by ESS questionnaire prior to treatment and at the follow-up. Results: Patients were divided into primary snoring and OSA groups. For the primary snoring group, PSG variables did not show significant results, except for a decrease in snoring. For the OSA group, the mean apnea-hypopnea index (AHI) was reduced from 23.0 +/- 11 to 5.3 +/- 4.0 and median ESS reduced significantly from 13.0 to 8.5. Complete response (AHI < 5) was found in 25 (40%) patients and partial response (AHI <= 10) in 27 (43%) patients. Conclusion: The findings validate the efficacy of the adjustable PM positioner for the safe treatment of OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). Patients and Methods: We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m 2 and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. Results: The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index ( P = .011) and between the FSS stage and body mass index ( P = .012) was found. There was no correlation between age ( P = .55) and gender ( P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P =.018. Conclusions: In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the association between sleep quality and quality of life of nursing professionals according to their work schedules. Methods: A prospective, cross-sectional, observational study was conducted between January and December 2010, with 264 nursing professionals, drawn from 989 subjects at Botucatu General Hospital and stratified by professional category. The Pittsburg Sleep Quality Index and the WHOQOL-bref were administered to evaluate sleep quality and quality of life, respectively. Self-reported demographic data were collected with a standard form. Continuous variables were reported as means and standard deviations, and categorical variables were expressed as proportions. Associations were evaluated using Spearman's correlation coefficient. The association of night-shift work and gender with sleep disturbance was evaluated by logistic regression analysis using a model adjusted for age and considering sleep disturbance the dependent variable. The level of significance was p < 0.05. Results: Night-shift work was associated with severe worsening of at least one component of sleep quality in the model adjusted for age (OR = 1.91; 95% CI 1.04; 3.50; p = 0.036). Female gender was associated with sleep disturbance (OR = 3.40; 95% CI 1.37; 8.40; p = 0.008). Quality of life and quality of sleep were closely correlated (R = -0.56; p < 0.001). Conclusions: Characteristics of the nursing profession affect sleep quality and quality of life, and these two variables are associated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effect of the use of an occlusal splint in children with bruxism in a pilot study with a short-term follow up. Seventeen children were recruited, only nine of whom formed the sample following the application of the inclusion criteria: presence of sleep bruxism for at least six months (based on parents' reports); presence of at least the first permanent molars; and no previous history of treatment involving an occlusal splint. The sample was submitted to a clinical exam. Other sleep problems were screened with the use of a sleep questionnaire filled out by parents before and after 90 days of occlusal splint usage. The children received a flat acrylic resin splint with full coverage of the occlusal surfaces to be worn in the maxilla. In children with erupting teeth, a space was created in the splint to allow normal eruption. After the 90-day period, the absence of sleep bruxism and sleep movements was noted in most of children. Moreover, snoring was reduced in nearly 50%, which raises a new issue to be investigated with regard to the pathophysiology of sleep bruxism. The use of an occlusal splint was effective in reducing the symptoms of sleep bruxism and other sleep problems. Further investigations should be carried out on the relationship between snoring and sleep bruxism in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to test the association between quality of sleep and stress in individuals with temporomandibular disorder (TMD). Methods: The study sample consisted of 354 adult subjects (males and females) from the municipality of Piacatu, São Paulo state, in the Southeast region of Brazil. Data were collected using the Fonseca’s Questionnaire to record the level of TMD, the Pittsburgh Sleep Quality Index (PSQI) to assess quality of sleep and the Social Readjustment Rating Scale (SRRS) to record stress level. The data were analyzed by the software Epi Info 2000 version 3.2 using a chi-square test at the 0.05 level of significance. Results: One hundred and eighty (50.8%) subjects had some level of TMD. The statistical analysis showed a significant relationship between the three stress scores and the presence or absence of sleep disorders, considering an overall PSQI score > 5 as an indicator of a subject with sleep problems (P<0.01). Conclusion: Both quality of sleep and stress levels were associated with TMD in this sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Apoio à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serous Background: There are few studies assessing the clinical manifestations of sleep breathing disorders and polysomnograms in several pediatric age ranges. This studied aimed to assess polysomnography results such as apnea-hypopnea index, mean oxygen saturation and sleep efficiency in children presenting with airway obstruction and adenotonsillar hypertrophy complaints, and to establish whether they are correlated to age and sex. Methods: A retrospective study with children of both sexes, aged between 2 and 12 years, with clinically suspected obstructive sleep apnea syndrome and adenotonsillar hypertrophy, who underwent polysomnography before surgery. The children were allocated to groups according to their age range (Group I: 2 to 4 years old; Group II: 5 to 8 years old; Group III: 9 to 12 years old). Apnea-hypopnea index, mean oxygen saturation and sleep efficiency data were compared between sexes and among the three groups (Student’s t test, p < 0.05). Results: Of 167 children studied by polysomnography, 76.6% were of school age and 67% were male. For all studied age ranges, there was no difference between sexes for the investigated parameters (body mass index, apnea-hypopnea index, mean oxygen saturation and sleep efficiency). As regards mean oxygen saturation, Group I showed the lowest value (89.9 ± 6.2). Apnea-hypopnea indexes were higher in male children aged between 2 and 4 years (9.9 ± 5.2). Group III had the lowest sleep efficiency (84.1 ± 9.2). Conclusion: There was a predilection of more severe cases of obstructive sleep apnea syndrome for children younger than four years, shown by higher apnea-hypopnea index per hour and lower mean oxygen saturation in this age range.