933 resultados para Site-stripping


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The charge stripping injection method has been adopted for the accumulation of light heavy ions in HIRFL-CSR. This method has some special requirements for the accelerating particles, and at the same time the structure of the injection orbit has to be changed. In this paper, the design of the orbit has been presented, as well as the calculation of the beam line matching. According to the result of commissioning, stripping injection can accumulate the beam to a higher current.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The catalytic properties of the passivated, reduced passivated, and fresh bulk molybdenum nitride for hydrazine decomposition were evaluated in a microreactor. The reaction route of hydrazine decomposition over molybdenum nitride catalysts seems to be the same as that of Ir/gamma-Al2O3 catalysts. Below 673 K, the hydrazine decomposes into N-2 and NH3. Above 673 K, the hydrazine decomposes into N-2 and NH3 first, and then the produced NH3 further dissociates into N-2 and H-2. From the in situ FT-IR spectroscopy, hydrazine is adsorbed and decomposes mainly on the Mo site of the Mo2N/gamma-Al2O3 catalyst. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 2.5-D and 3-D multi-fold GPR survey was carried out in the Archaeological Park of Aquileia (northern Italy). The primary objective of the study was the identification of targets of potential archaeological interest in an area designated by local archaeological authorities. The second geophysical objective was to test 2-D and 3-D multi-fold methods and to study localised targets of unknown shape and dimensions in hostile soil conditions. Several portions of the acquisition grid were processed in common offset (CO), common shot (CSG) and common mid point (CMP) geometry. An 8×8 m area was studied with orthogonal CMPs thus achieving a 3-D subsurface coverage with azimuthal range limited to two normal components. Coherent noise components were identified in the pre-stack domain and removed by means of FK filtering of CMP records. Stack velocities were obtained from conventional velocity analysis and azimuthal velocity analysis of 3-D pre-stack gathers. Two major discontinuities were identified in the area of study. The deeper one most probably coincides with the paleosol at the base of the layer associated with activities of man in the area in the last 2500 years. This interpretation is in agreement with the results obtained from nearby cores and excavations. The shallow discontinuity is observed in a part of the investigated area and it shows local interruptions with a linear distribution on the grid. Such interruptions may correspond to buried targets of archaeological interest. The prominent enhancement of the subsurface images obtained by means of multi-fold techniques, compared with the relatively poor quality of the conventional single-fold georadar sections, indicates that multi-fold methods are well suited for the application to high resolution studies in archaeology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports on the performance of a bismuth-coated carbon microdisk electrode (BiFμE) for the determination of trace heavy metals by anodic stripping voltammetry (ASV). The BiFμE was prepared by electrodeposition of a metallic bismuth film onto the microdisk, by applying an in-situ electroplating procedure. To test the performance of the BiFμE, ASV measurements were performed on synthetic solutions containing Cd2+, Pb2+, and Cu2+ as target ions. The results indicated that cadmium and lead gave well-defined ASV peaks with no interference, and their quantitative determination could be carried out straightforwardly. In particular, linear calibration curves over the range 5.0 x 10-8-1.0 x 10-6M for both ions, and detection limits of 7.8 and 2.9 nM, for cadmium and lead, respectively, after applying a 60 sec preconcentration step, were obtained. The reproducibility was also satisfactory, the relative standard deviation (RSD) being within 2.5% for both ions. Copper, instead, gave an ASV response that. in most experimental conditions, overlapped with that of bismuth. This circumstance made the determination of copper at the BiFμE difficult. Since the latter element could be detected reliably at the uncoated carbon microdisk electrode (CμE), both BiFμE and CμE were employed, respectively, for the determination of lead and copper ions in drinking water, wine, and tomato sauce.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

National Natural Science Foundation of China [40771205]; National Science Fund for Distinguished Young Scholars [40625002]; Chinese Academy of Sciences [KZCX2-YW-315]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a new method for the simultaneous determination of Pb(II) and Cd(II) on the multiwalled carbon nanotubes (MWNT)-Nafion-bismuth modified glassy carbon electrode (GCE) using square-wave anodic stripping voltammetry has been studied. Scanning electron microscopy was used to investigate the characteristics of the MWNT-Nafion-bismuth modified GCE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we investigated the analytical performances of the bismuth-modified zeolite doped carbon paste electrode (BiF-ZDCPE) for trace Cd and Pb analysis. The characteristics of bismuth-modified electrodes were improved greatly via addition of synthetic zeolite into carbon paste. To obtain high reproducibility and sensitivity, optimum experimental conditions for bismuth deposition Were Studied.