904 resultados para Simultaneous Localization
Resumo:
In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC) procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid) and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione) in multivitamin tablets. The linearity of the method was excellent (R² > 0.999) over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.
Resumo:
In the current study, an alternative method has been proposed for simultaneous analysis of palmitic, stearic, oleic, linoleic, and linolenic acids by capillary zone electrophoresis (CZE) using indirect detection. The background electrolyte (BGE) used for the analysis of these fatty acids (FAs) consisted of 15.0 mmol L−1 NaH2PO4/Na2HPO4 at pH 6.86, 4.0 mmol L−1 SDBS, 8.3 mmol L−1 Brij 35, 45% v/v acetonitrile (can), and 2.1% n-octanol. The FAs quantification of FAs was performed using a response factor approach, which provided a high analytical throughput for the real sample. The CZE method, which was applied successfully for the analysis of pequi pulp, has advantages such as short analysis time, absence of lipid fraction extraction and derivatization steps, and no significant difference in the 95% confidence intervals for FA quantification results, compared to the gas chromatography official method (AOCS Ce 1h-05).
Resumo:
A stability-indicating RP-HPLC method is presented for determination of gatifloxacin and flurbiprofen in binary combination. Gatifloxacin, flurbiprofen and their degradation products were detected at 254 nm using a BDS Hypersil C8 (250 X 4.6 mm, 5 µm) column and mixture of 20 mM phosphate buffer (pH 3.0) and methanol 30:70 v/v as mobile phase. Response was linear over the range of 15-105 mg mL-1 for gatifloxacin (r² > 0.998) and of 1.5-10.5 mg mL-1 for flurbiprofen (r² > 0.999). The developed method efficiently separated the analytical peaks from degradation products (peak purity index > 0.9999). The method developed can be applied successfully for determination of gatifloxacin and flurbiprofen in human serum, urine, pharmaceutical formulations, and their stability studies.
Resumo:
Among other applications, Ipomoea pes-caprae is popularly used to treat jellyfish stings, supporting the development of a product for dermatological use. Hydroethanolic spray-dried extract was chosen for the further development of phytomedicines, and a stability-indicative HPLC-UV method was developed and validated for the determination of isoquercitrin and isochlorogenic acids A, B and C. The method was developed using a C18 column (250 x 4.6 mm, 5 µm) with an acetonitrile:water mobile phase at pH 3.0 in a gradient run. The four constituents and other unidentified components of the extract were appropriately resolved without interference of degradation products after stress tests (acid, alkali, neutral, oxidant, photolysis). The method showed linearity in the isoquercitrin concentration range from 5.0-50.0 µg mL-1, with adequate precision (RSD% < 2.5% for the intra- and inter-day studies), accuracy (recovery of 100.0 ± 2.0%), and robustness. Both the herbal drug and spray-dried extract of I. pes-caprae were subjected to stability studies in accelerated and long-term conditions over four months. The samples maintained their characteristics and marker contents (< 10% of variation).
Resumo:
A simple and sensitive spectrophotometric method is proposed for the simultaneous determination of protocatechuic acid and protocatechuic aldehyde. The method is based on the difference in the kinetic rates of the reactions of analytes with [Ag(NH3)2]+ in the presence of polyvinylpyrrolidone to produce silver nanoparticles. The data obtained were processed by chemometric methods using principal component analysis artificial neural network and partial least squares. Excellent linearity was obtained in the concentration ranges of 1.23-58.56 µg mL-1 and 0.08-30.39 µg mL-1 for PAC and PAH, respectively. The limits of detection for PAC and PAH were 0.039 and 0.025 µg mL-1, respectively.
Resumo:
A method has been developed for the simultaneous determination of Cd and Pb in antibiotics used in sugar-cane fermentation by GFAAS. The integrated platform of transversely heated graphite atomizer was treated with tungsten to form a coating of tungsten carbide. Six samples of commercial solid antibiotics were analyzed by injecting 20 µL of digested samples into the pretreated graphite platform with co-injection of 5 µL of 1000 mg L-1 Pd as chemical modifier. Samples were mineralized in a closed-vessel microwave-assisted acid-digestion system using nitric acid plus hydrogen peroxide. The pyrolysis and atomization temperatures of the heating program of the atomizer were selected as 600°C and 2200°C, respectively. The calculated characteristic mass for Cd and Pb was 1.6 pg and 42 pg, respectively. Limits of detection (LOD) based on integrated absorbance were 0.02 µg L-1 Cd and 0.7 µg L-1 Pb and the relative standard deviations (n = 10) for Cd and Pb were 5.7% and 8.0%, respectively. The recoveries of Cd and Pb added to the digested samples varied from 91% to 125% (Cd) and 80% to 112% (Pb).
Resumo:
A direct spectrophotometric method for simultaneous determination of Co(II) and Ni(II), with diethanoldithiocarbamate (DEDC) as complexing agent, is proposed using the maximum absorption at 360 and 638 nm (Co(II)/DEDC) and 390 nm (Ni/DEDC). Adjusting the best metal/ligand ratio, supporting eletrolite, pH, and time of analysis, linear analytical curves from 1.0 10-6-4.0 10-4 for Co(II) in the presence of Ni 1.0 10-6-1.0 10-4 mol L-1 were observed. No further treatment or calculation processes have been necessary. Recoveries in different mixing ratios were of 99%. Interference of Fe(III), Cu(II), Zn(II) and Cd(II), and anions as NO3-, Cl-, ClO4-, citrate and phosphate has been evaluated. The method was applied to natural waters spiked with the cations.
Resumo:
The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.
Resumo:
The aim of this work was to develop and validate simple, accurate and precise spectroscopic methods (multicomponent, dual wavelength and simultaneous equations) for the simultaneous estimation and dissolution testing of ofloxacin and ornidazole tablet dosage forms. The medium of dissolution used was 900 ml of 0.01N HCl, using a paddle apparatus at a stirring rate of 50 rpm. The drug release was evaluated by developed and validated spectroscopic methods. Ofloxacin and ornidazole showed 293.4 and 319.6nm as λmax in 0.01N HCl. The methods were validated to meet requirements for a global regulatory filing. The validation included linearity, precision and accuracy. In addition, recovery studies and dissolution studies of three different tablets were compared and the results obtained show no significant difference among products.
Resumo:
PURPOSE: To explore the relationship between morphological characteristics and histologic localization of metastasis within sentinel lymph nodes (SLN) and axillary spread in women with breast cancer. METHODS: We selected 119 patients with positive SLN submitted to complete axillary lymph node dissection from July 2002 to March 2007. We retrieved the age of patients and the primary tumor size. In the primary tumor, we evaluated histologic and nuclear grade, and peritumoral vascular invasion (PVI). In SLNs we evaluated the size of metastasis, their localization in the lymph node, number of foci, number of involved lymph nodes, and extranodal extension. RESULTS: Fifty-one (42.8%) patients had confirmed additional metastasis in non-sentinel lymph nodes (NLSN). High histologic grade, PVI, intraparenchymatous metastasis, extranodal neoplastic extension and size of metastasis were associated with positive NLSN. SLN metastasis affecting the capsule were associated to low risk incidence of additional metastasis. After multivariate analysis, PVI and metastasis size in the SLN remained as the most important risk factors for additional metastasis. CONCLUSIONS:The risk of additional involvement of NSLN is higher in patients with PVI and it increases progressively according the histologic localization in the lymph node, from capsule, where the afferent lymphatic channel arrives, to the opposite side of capsule promoting the extranodal extension. Size of metastasis greater than 6.0 mm presents higher risk of additional lymph node metastasis.
Resumo:
Tämän pro gradu– tutkielman tavoitteena oli testata täytettyjen taukojen (er ja erm) esiintymistiheyttä, sijaintia kieliopillisessa rakenteessa sekä funktioita Kjellmerin (2003) korpus-tutkimuksessa. Materiaalina käytin viiden yhdysvaltalaisen poliitikon puhetta keskusteluohjelmasta Larry King Live. Tutkimuksessani sovelsin Kjellmerin tutkimusmenetelmiä, joita muokkasin huomattavasti suppeampaan materiaaliini sopiviksi. Lähestymistapani oli täten induktiivinen toisin kuin testatussa tutkimuksessa. Materiaalini oli tarkoituksellisesti rajattu, sillä halusin selvittää, kuvaavatko Kjellmerin laajaan materiaaliin perustuvat tutkimustulokset myös täytettyjen taukojen käyttöä suppeammassa materiaalissa. Materiaalini (kokonaisuudessaan 101 minuuttia) transkriboin ortografisesti. Analyysissäni arvioin täytettyjen taukojen esiintymistiheyden puhujakohtaisesti ja koko ryhmälle suhteuttamalla täytettyjen taukojen lukumäärän kokonaissanamäärään. Tämän jälkeen tein perinteisen kielioppianalyysin rakenteista, joita edeltää tai joissa esiintyy täytetty tauko, ja täytettyjen taukojen sijainnin perusteella luokittelin ne sana-, lauseke-, ja lausetasolle. Lopuksi analysoin täytettyjen taukojen käyttöä soveltaen Kjellmerin ehdottamia funktioita (hesitaatio, vuorottelujäsennyksen merkitseminen, huomion herättäminen ja kontaktin luominen, korostus ja korjaus) ja niiden piirteitä omaan materiaaliini. Tutkimukseni perusteella täytetyt tauot esiintyvät tutkitun viiden poliitikon puheessa suhteellisen usein. Puhujakohtaiset eroavaisuudet olivat kuitenkin huomattavat. Kieliopillisen luokitteluni mukaan sana-, lauseke- ja lausetasot eivät täysin kuvaa täytettyjen taukojen sijoittumista, sillä täytetyt tauot edelsivät mm. määre-lauseita, jotka eivät vastaa lausetasoa englannin kielessä. Materiaalini funktioanalyysi osoitti, että täytetyt tauot yleensä vastaavat yhtä tai useampaa Kjellmerin ehdottamaa funktioita. Lisäksi tutkimukseni mukaan täytetyillä tauoilla on ainakin yksi rakenteellinen funktio. Analyysini perusteella Kjellmerin tutkimustulokset ovat siis pääosin sovellettavissa suppeampaan materiaaliin. Puutteiksi hänen tutkimuksessaan osoittautuivat funktioanalyysille tärkeän kontekstuaalisen informaation puute sekä keskittyminen täytettyihin taukoihin, jotka esiintyvät vain tietyissä kielioppirakenteissa. Yleisesti voin tutkimukseni pohjalta todeta, että täytetyt tauot ovat vielä vajaasti tunnettuja ja että kieliopillisen sijoituksen ja funktioiden lisätutkimus on tarpeellista.
Resumo:
Both atom localization and Raman cooling, considered in the thesis, reflect recent progress in the area of all-optical methods. We focus on twodimensional (2D) case, using a four-level tripod-type atomic scheme for atom localization within the optical half-wavelength as well as for efficient subrecoil Raman cooling. In the first part, we discuss the principles of 1D atom localization, accompanying by an example of the measurement of a spontaneously-emitted photon. Modifying this example, one archives sub-wavelength localization of a three-level -type atom, measuring the population in its upper state. We go further and obtain 2D sub-wavelength localization for a four-level tripod-type atom. The upper-state population is classified according to the spatial distribution, which in turn forms such structures as spikes, craters and waves. The second part of the thesis is devoted to Raman cooling. The cooling process is controlled by a sequence of velocity-selective transfers from one to another ground state. So far, 1D deep subrecoil cooling has been carried out with the sequence of square or Blackman pulses, applied to -type atoms. In turn, we discuss the transfer of atoms by stimulated Raman adiabatic passage (STIRAP), which provides robustness against the pulse duration if the cooling time is not in any critical role. A tripod-type atomic scheme is used for the purpose of 2D Raman cooling, allowing one to increase the efficiency and simplify the realization of the cooling.
Resumo:
This paper deals with the use of the conjugate gradient method of function estimation for the simultaneous identification of two unknown boundary heat fluxes in parallel plate channels. The fluid flow is assumed to be laminar and hydrodynamically developed. Temperature measurements taken inside the channel are used in the inverse analysis. The accuracy of the present solution approach is examined by using simulated measurements containing random errors, for strict cases involving functional forms with discontinuities and sharp-corners for the unknown functions. Three different types of inverse problems are addressed in the paper, involving the estimation of: (i) Spatially dependent heat fluxes; (ii) Time-dependent heat fluxes; and (iii) Time and spatially dependent heat fluxes.
Resumo:
In this report are described means for indoor localization in special, challenging circum-stances in marine industry. The work has been carried out in MARIN project, where a tool based on mobile augmented reality technologies for marine industry is developed. The tool can be used for various inspection and documentation tasks and it is aimed for improving the efficiency in design and construction work by offering the possibility to visualize the newest 3D-CAD model in real environment. Indoor localization is needed to support the system in initialization of the accurate camera pose calculation and auto-matically finding the right location in the 3D-CAD model. The suitability of each indoor localization method to the specific environment and circumstances is evaluated.