968 resultados para Signal detection
Resumo:
Combination of signals from the two eyes is the gateway to stereo vision. To gain insight into binocular signal processing, we studied binocular summation for luminance-modulated gratings (L or LM) and contrast-modulated gratings (CM). We measured 2AFC detection thresholds for a signal grating (0.75 c/deg, 216msec) shown to one eye, both eyes, or both eyes out-of-phase. For LM and CM, the carrier noise was in both eyes, even when the signal was monocular. Mean binocular thresholds for luminance gratings (L) were 5.4dB better than monocular thresholds - close to perfect linear summation (6dB). For LM and CM the binocular advantage was again 5-6dB, even when the carrier noise was uncorrelated, anti-correlated, or at orthogonal orientations in the two eyes. Binocular combination for CM probably arises from summation of envelope responses, and not from summation of these conflicting carrier patterns. Antiphase signals produced no binocular advantage, but thresholds were about 1-3dB higher than monocular ones. This is not consistent with simple linear summation, which should give complete cancellation and unmeasurably high thresholds. We propose a three-channel model in which noisy monocular responses to the envelope are binocularly combined in a contrast-weighted sum, but also remain separately available to perception via a max operator. Vision selects the largest of the three responses. With in-phase gratings the binocular channel dominates, but antiphase gratings cancel in the binocular channel and the monocular channels mediate detection. The small antiphase disadvantage might be explained by a subtle influence of background responses on binocular and monocular detection.
Resumo:
This novel capillary electrophoresis microchip, or also known as μTAS (micro total analysis system) was designed to separate complex aqueous based compounds, similar to commercial CE & microchip (capillary electrophoresis) systems, but more compact. This system can be potentially used for mobile/portable chemical analysis equipment. Un-doped silicon wafer & ultra-thin borofloat glass (Pyrex) wafers have been used to fabricate the device. Double-L injection feature, micro pillars column, bypass separation channel & hybrid- referenced C4D electrodes were designed to achieve a high SNR (signal to noise ratio), easy- separation, for a durable and reusable μTAS for CE use.
Resumo:
This thesis is concerned with change point analysis for time series, i.e. with detection of structural breaks in time-ordered, random data. This long-standing research field regained popularity over the last few years and is still undergoing, as statistical analysis in general, a transformation to high-dimensional problems. We focus on the fundamental »change in the mean« problem and provide extensions of the classical non-parametric Darling-Erdős-type cumulative sum (CUSUM) testing and estimation theory within highdimensional Hilbert space settings. In the first part we contribute to (long run) principal component based testing methods for Hilbert space valued time series under a rather broad (abrupt, epidemic, gradual, multiple) change setting and under dependence. For the dependence structure we consider either traditional m-dependence assumptions or more recently developed m-approximability conditions which cover, e.g., MA, AR and ARCH models. We derive Gumbel and Brownian bridge type approximations of the distribution of the test statistic under the null hypothesis of no change and consistency conditions under the alternative. A new formulation of the test statistic using projections on subspaces allows us to simplify the standard proof techniques and to weaken common assumptions on the covariance structure. Furthermore, we propose to adjust the principal components by an implicit estimation of a (possible) change direction. This approach adds flexibility to projection based methods, weakens typical technical conditions and provides better consistency properties under the alternative. In the second part we contribute to estimation methods for common changes in the means of panels of Hilbert space valued time series. We analyze weighted CUSUM estimates within a recently proposed »high-dimensional low sample size (HDLSS)« framework, where the sample size is fixed but the number of panels increases. We derive sharp conditions on »pointwise asymptotic accuracy« or »uniform asymptotic accuracy« of those estimates in terms of the weighting function. Particularly, we prove that a covariance-based correction of Darling-Erdős-type CUSUM estimates is required to guarantee uniform asymptotic accuracy under moderate dependence conditions within panels and that these conditions are fulfilled, e.g., by any MA(1) time series. As a counterexample we show that for AR(1) time series, close to the non-stationary case, the dependence is too strong and uniform asymptotic accuracy cannot be ensured. Finally, we conduct simulations to demonstrate that our results are practically applicable and that our methodological suggestions are advantageous.
Resumo:
Breast cancer, the most commonly diagnosed type of cancer in women, is a major cause of morbidity and mortality in the western world. Well-established risk factors of breast cancer are mostly related to women’s reproductive history, such as early menarche, late first pregnancy and late menopause. Survival rates have improved due to a combination of factors, including better health education, early detection with large-scale use of screening mammogram, improved surgical techniques, as well as widespread use of adjuvant therapy. At initial presentation, clinicopathological features of breast cancer such as age, nodal status, tumour size, tumour grade, and hormonal receptor status are considered to be the standard prognostic and predictive markers of patient survival, and are used to guide appropriate treatment strategies. Lymphovascular invasion (LBVI), including lymphatic (LVI) and blood (BVI) vessel invasion, has been reported to be prognostic and merit accurate evaluation, particularly in patients with node negative tumours who might benefit from adjuvant chemotherapy. There is a lack of standard assessment and agreement on distinguishing LVI from BVI despite the major challenges in the field. A systematic review of the literatures, examining methods of detection and the prognostic significance of LBVI, LVI and BVI, was carried out. The majority of studies used haematoxylin and eosin (H&E) and classical histochemistry to identify LVI and BVI. Only few recent studies used immunohistochemistry (IHC) staining of the endothelium lining lymphatic and blood vessels, and were able to show clear differences between LVI and BVI. The prognostic significance of LBVI and LVI was well-documented and strongly associated with aggressive features of breast tumours, while the prognostic value and the optimal detection method of BVI were unclear. Assessment and prognostic value of LBVI on H&E sections (LBVIH&E) was examined and compared to that of LVI and BVI detected using IHC with D2-40 for LVI (LVID2–40) and Factor VIII for BVI (BVIFVIII) in patients with breast cancer including node negative and triple negative patients (n=360). LBVIH&E, LVID2–40 and BVIFVIII were present in 102 (28%), 127 (35%) and 59 (16%) patients respectively. In node negative patients (206), LBVIH&E, LVID2–40 and BVIFVIII were present in 41 (20%), 53 (26%) and 21 (10%) respectively. In triple negative patients (102), LBVIH&E, LVID2–40 and BVIFVIII were present in 35 (29%), 36 (35%) and 14 (14%) respectively. LBVIH&E, LVID2–40 and BVIFVIII were all significantly associated with tumour recurrence in all cohorts. On multivariate survival analysis, only LVID2–40 and BVIFVIII were independent predictors of cancer specific survival (CSS) in the whole cohort (P=0.022 and P<0.001 respectively), node negative (P=0.008 and P=0.001 respectively) and triple negative patients (P=0.014 and P<0.001 respectively). Assessment of LVI and BVI by IHC, using D2-40 and Factor VIII, improves prediction of outcome in patients with node negative and triple negative breast cancer and was superior to the conventional detection method. Breast cancer is recognised as a complex molecular disease and histologically identical tumours may have highly variable outcomes, including different responses to therapy. Therefore, there is a compelling need for new prognostic and predictive markers helpful of selecting patients at risk and patients with aggressive diseases who might benefit from adjuvant and targeted therapy. It is increasingly recognised that the development and progression of human breast cancer is not only determined by genetically abnormal cells, but also dependent on complex interactions between malignant cells and the surrounding microenvironment. This has led to reconsider the features of tumour microenvironment as potential predictive and prognostic markers. Among these markers, tumour stroma percentage (TSP) and tumour budding, as well as local tumour inflammatory infiltrate have received recent attention. In particular, the local environment of cytokines, proteases, angiogenic and growth factors secreted by inflammatory cells and stromal fibroblasts has identified crucial roles in facilitating tumour growth, and metastasis of cancer cells through lymphatic and/or blood vessel invasion. This might help understand the underlying process promoting tumour invasion into these vessels. An increase in the proportion of tumour stroma and an increase in the dissociation of tumour cells have been associated with poorer survival in a number of solid tumours, including breast cancer. However, the interrelationship between these variables and other features of the tumour microenvironment in different subgroups of breast cancer are not clear. Also, whether their prognostic values are independent of other components of the tumour microenvironment have yet to be identified. Therefore, the relationship between TSP, clinicopathological characteristics and outcome in patients with invasive ductal breast cancer, in particular node negative and triple negative disease was examined in patients with invasive ductal breast cancer (n=361). The TSP was assessed on the haematoxylin and eosin-stained tissue sections. With a cut-off value of 50% TSP, patients with ≤50% stroma were classified as the low-TSP group and those with >50% stroma were classified as the high-TSP group. A total of 109 (30%) patients had high TSP. Patients with high TSP were old age (P=0.035), had involved lymph node (P=0.049), Her-2 positive tumours (P=0.029), low-grade peri-tumoural inflammatory infiltrate (P=0.034), low CD68+ macrophage infiltrate (P<0.001), low CD4+ (P=0.023) and low CD8+ T-lymphocytes infiltrate (P=0.017), tumour recurrence (P=0.015) and shorter CSS (P<0.001). In node negative patients (n=207), high TSP was associated with low CD68+ macrophage infiltrate (P=0.001), low CD4+ (P=0.040) and low CD8+ T-lymphocytes infiltrate (P=0.016) and shorter CSS (P=0.005). In triple negative patients (n=103), high TSP was associated with increased tumour size (P=0.017) high tumour grade (P=0.014), low CD8+ T-lymphocytes infiltrate (P=0.048) and shorter CSS (P=0.041). The 15-year cancer specific survival rate was 79% vs 21% in the low-TSP group vs high-TSP group. On multivariate survival analysis, a high TSP was associated with reduced CSS in the whole cohort (P=0.007), node negative patients (P=0.005) and those who received systemic adjuvant therapy (P=0.016), independent of other pathological characteristics including local host inflammatory responses. Therefore, a high TSP in invasive ductal breast cancer was associated with recurrence and poorer long-term survival. The inverse relation with the tumour inflammatory infiltrate highlights the importance of the amount of tumour stroma on immunological response in patients with invasive ductal breast cancer. Implementing this simple and reproducible parameter in routine pathological examination may help optimise risk stratification in patients with breast cancer. Similarly, the relationship between tumour budding, clinicopathological characteristics and outcome was examined in patients with invasive ductal breast cancer (n=474), using routine pathological sections. Tumour budding was associated with several adverse pathological characteristics, including positive lymph node (P=0.009), presence of LVI (P<0.001), and high TSP (P=0.001) and low-grade general peri-tumural inflammatory infiltrative (P=0.002). In node negative patients, a high tumour budding was associated with presence of LVI (P<0.001) and low-grade general peri-tumural inflammatory infiltrative (P=0.038). On multivariate survival analysis, tumour budding was associated with reduced CSS (P=0.001), independent of nodal status, tumour necrosis, CD8+ and CD138+ inflammatory cells infiltrate, LVI, BVI and TSP. Furthermore, tumour budding was independently associated with reduced CSS in node negative patients (P=0.004) and in those who have low TSP (P=0.003) and high-grade peri-tumoural inflammatory infiltrative (P=0.012). A high tumour budding was significantly associated with shorter CSS in luminal B and triple negative breast cancer subtypes (all P<0.001). Therefore, tumour budding was a significant predictor of poor survival in patients with invasive ductal breast cancer, independent of adverse pathological characteristics and components of tumour microenvironment. These results suggest that tumour budding may promote disease progression through a direct effect on local and distant invasion into lymph nodes and lymphatic vessels. Therefore, detection of tumour buds at the stroma invasive front might therefore represent a morphologic link between tumour progression, lymphatic invasion, spread of tumour cells to regional lymph nodes, and the establishment of metastatic dissemination. Given the potential importance of the tumour microenvironment, the characterisation of intracellular signalling pathways is important in the tumour microenvironment and is of considerable interest. One plausible signalling molecule that links tumour stroma, inflammatory cell infiltrate and tumour budding is the signal transducer and activator of transcription (STAT). The relationship between total and phosphorylated STAT1 (ph-STAT1), and total and ph-STAT3 tumour cell expression, components of tumour microenvironment and survival in patients with invasive ductal breast cancer was examined. IHC of total and ph-STAT1/STAT3 was performed on tissue microarray of 384 breast cancer specimens. Cellular STAT1 and cellular STAT3 expression at both cytoplasmic and nuclear locations were combined and identified as STAT1/STAT3 tumour cell expression. These results were then related to CSS and phenotypic features of the tumour and host. A high ph-STAT1 and a high ph-STAT3 tumour cell expression was associated with increased ER (P=0.001 and P<0.001 respectively) and PR (all P<0.05), reduced tumour grade (P=0.015 and P<0.001 respectively) and necrosis (all P=0.001). Ph-STAT1 was associated with increased general peri-tumoural inflammatory infiltrate (P=0.007) and ph-STAT3 was associated with lower CD4+ T-lymphocyte infiltrate (P=0.024). On multivariate survival analysis, including both ph-STAT1 and ph-STAT3 tumour cell expression, only high ph-STAT3 tumour cell expression was significantly associated with improved CSS (P=0.010) independent of other tumour and host-based factors. In patients with high necrosis grade, high ph-STAT3 tumour cell expression was independent predictor of improved CSS (P=0.021). Ph-STAT1 and ph-STAT3 were also significantly associated with improved cancer specific survival in luminal A and B subtypes. STAT1 and STAT3 tumour cell expression appeared to be an important determinant of favourable outcome in patients with invasive ductal breast cancer. The present results suggest that STATs may affect disease outcome through direct impact on tumour cells, and the surrounding microenvironment. The above observations of the present thesis point to the importance of the tumour microenvironment in promoting tumour budding, LVI and BVI. The observations from STATs work may suggest that an important driving mechanism for the above associations is the presence of tumour necrosis, probably secondary to hypoxia. Further work is needed to examine the interaction of other molecular pathways involved in the tumour microenvironment, such as HIF and NFkB in patients with invasive ductal breast cancer.
Resumo:
Acoustic Emission (AE) monitoring can be used to detect the presence of damage as well as determine its location in Structural Health Monitoring (SHM) applications. Information on the time difference of the signal generated by the damage event arriving at different sensors is essential in performing localization. This makes the time of arrival (ToA) an important piece of information to retrieve from the AE signal. Generally, this is determined using statistical methods such as the Akaike Information Criterion (AIC) which is particularly prone to errors in the presence of noise. And given that the structures of interest are surrounded with harsh environments, a way to accurately estimate the arrival time in such noisy scenarios is of particular interest. In this work, two new methods are presented to estimate the arrival times of AE signals which are based on Machine Learning. Inspired by great results in the field, two models are presented which are Deep Learning models - a subset of machine learning. They are based on Convolutional Neural Network (CNN) and Capsule Neural Network (CapsNet). The primary advantage of such models is that they do not require the user to pre-define selected features but only require raw data to be given and the models establish non-linear relationships between the inputs and outputs. The performance of the models is evaluated using AE signals generated by a custom ray-tracing algorithm by propagating them on an aluminium plate and compared to AIC. It was found that the relative error in estimation on the test set was < 5% for the models compared to around 45% of AIC. The testing process was further continued by preparing an experimental setup and acquiring real AE signals to test on. Similar performances were observed where the two models not only outperform AIC by more than a magnitude in their average errors but also they were shown to be a lot more robust as compared to AIC which fails in the presence of noise.
Resumo:
The work described in this Master’s Degree thesis was born after the collaboration with the company Maserati S.p.a, an Italian luxury car maker with its headquarters located in Modena, in the heart of the Italian Motor Valley, where I worked as a stagiaire in the Virtual Engineering team between September 2021 and February 2022. This work proposes the validation using real-world ECUs of a Driver Drowsiness Detection (DDD) system prototype based on different detection methods with the goal to overcome input signal losses and system failures. Detection methods of different categories have been chosen from literature and merged with the goal of utilizing the benefits of each of them, overcoming their limitations and limiting as much as possible their degree of intrusiveness to prevent any kind of driving distraction: an image processing-based technique for human physical signals detection as well as methods based on driver-vehicle interaction are used. A Driver-In-the-Loop simulator is used to gather real data on which a Machine Learning-based algorithm will be trained and validated. These data come from the tests that the company conducts in its daily activities so confidential information about the simulator and the drivers will be omitted. Although the impact of the proposed system is not remarkable and there is still work to do in all its elements, the results indicate the main advantages of the system in terms of robustness against subsystem failures and signal losses.
Resumo:
A general description of the work presented in this thesis can be divided into three areas of interest: micropore fabrication, nanopore modification, and their applications. The first part of the thesis is related to the novel, reliable, cost-effective, potable, mass-productive, robust, and ease of use micropore flowcell that works based on the RPS technique. Based on our first goal, which was finding an alternate materials and processes that would shorten production times while lowering costs and improving signal quality, the polyimide film was used as a substrate to create precise pores by femtosecond laser, and the resulting current blockades of different sizes of the nanoparticles were recorded. Based on the results, the device can detecting nano-sized particles by changing the current level. The experimental and theoretical investigation, scanning electron microscopy, and focus ion beam were performed to explain the micropore's performance. The second goal was design and fabrication of a leak-free, easy-to-assemble, and portable polymethyl methacrylate flowcell for nanopore experiments. Here, ion current rectification was studied in our nanodevice. We showed a self-assembly-based, controllable, and monitorable in situ Poly(l-lysine)- g-poly(ethylene glycol) coating method under voltage-driven electrolyte flow and electrostatic interaction between nanopore walls and PLL backbones. Using designed nanopore flowcell and in situ monolayer PLL-g-PEG functionalized 20±4 nm SiN nanopores, we observed non-sticky α-1 anti-trypsin protein translocation. additionally, we could show the enhancement of translocation events through this non-sticky nanopore, and also, estimate the volume of the translocated protein. In this study, by comparing the AAT protein translocation results from functionalized and non-functionalized nanopore we demonstrated the 105 times dwell time reduction (31-0.59ms), 25% amplitude enhancement (0.24-0.3 nA), and 15 times event’s number increase (1-15events/s) after functionalization in 1×PBS at physiological pH. Also, the AAT protein volume was measured, close to the calculated AAT protein hydrodynamic volume and previous reports.
Resumo:
Biomarkers are biological indicators of human health conditions. Their ultra-sensitive quantification is of cardinal importance in clinical monitoring and early disease diagnosis. Biosensors are some worldwide simple and easy-to-use analytical devices as a matter of fact, biosensors using electrochemiluminescence (ECL) are one of the most promising biosensors that needs an ever-increasing sensitivity for improving its clinical effectiveness. The principal aspiration of this project is the investigation of the ECL generation mechanisms for enhancing the ECL intensity and the development of an ultrasensitive sensor, the use of metal-oxide materials (Mox) and the substitution of metal-free dyes. Novel dyes such as BODIPY, TADF are used to improve the sensitivity of ECL techniques thanks to their advantageous and tunable properties, enhancing the signal and also the ECL efficiency. Additionally, the use of Mox could be beneficial for the investigation of two different ECL mechanisms, which occur simultaneously. In this thesis, the investigation of size and distance effects on electrochemical (EC) mechanisms was carried out through the innovative combination of a standard detection system using different size of micromagnetic beads (MBs). That allowed the discovery of an unexpected and highly efficient mechanistic path for electrochemical generation at small distances from the electrode’s surface. The smallest MBs (0.1μm) demostrate an enhancement of electrochemical signal than the bigger one (2.8μm) until 4 times of magnitude. Finally, a novel ultrasensitive sensor, based on the coreactant-luminophores mechanism, was developed for the determination of whole viral genome specific for cardiac HBV and COVID-19 virus. In conclusion, the ECL and the use of EC techniques (such as amperometry), improved the understanding of mechanisms responsible for the ECL/EC signal led to a great enhancement in the signal.
Resumo:
Background and Aim: Acute cardiac rejection is currently diagnosed by endomyocardial biopsy (EMB), but multiparametric cardiac magnetic resonance (CMR) may be a non-invasive alternative by its capacity for myocardial structure and function characterization. Our primary aim was to determine the utility of multiparametric CMR in identifying acute graft rejection in paediatric heart transplant recipients. The second aim was to compare textural features of parametric maps in cases of rejection versus those without rejection. Methods: Fifteen patients were prospectively enrolled for contrast-enhanced CMR followed by EMB and right heart catheterization. Images were acquired on a 1,5 Tesla scanner including T1 mapping (modified Look-Locker inversion recovery sequence – MOLLI) and T2 mapping (modified GraSE sequence). The extracellular volume (ECV) was calculated using pre- and post-gadolinium T1 times of blood and myocardium and the patient’s hematocrit. Markers of graft dysfunction including hemodynamic measurements from echocardiography, catheterization and CMR were collated. Patients were divided into two groups based on degree of rejection at EMB: no rejection with no change in treatment (Group A) and acute rejection requiring new therapy (Group B). Statistical analysis included student’t t test and Pearson correlation. Results: Acute rejection was diagnosed in five patients. Mean T1 values were significantly associated with acute rejection. A monotonic, increasing trend was noted in both mean and peak T1 values, with increasing degree of rejection. ECV was significantly higher in Group B. There was no difference in T2 signal between two groups. Conclusion: Multiparametric CMR serves as a noninvasive screening tool during surveillance encounters and may be used to identify those patients that may be at higher risk of rejection and therefore require further evaluation. Future and multicenter studies are necessary to confirm these results and explore whether multiparametric CMR can decrease the number of surveillance EMBs in paediatric heart transplant recipients.
Resumo:
From 2010, the Proton Radius has become one of the most interest value to determine. The first proof of not complete understanding of its internal structure was the measurement of the Lamb Shift using the muonic hydrogen, leading to a value 7σ lower. A new road so was open and the Proton Radius Puzzle epoch begun. FAMU Experiment is a project that tries to give an answer to this Puzzle implementing high precision experimental apparatus. The work of this thesis is based on the study, construction and first characterization of a new detection system. Thanks to the previous experiments and simulations, this apparatus is composed by 17 detectors positioned on a semicircular crown with the related electronic circuit. The detectors' characterization is based on the use of a LabView program controlling a digital potentiometer and on other two analog potentiometers, all three used to set the amplitude of each detector to a predefined value, around 1.2 V, set on the oscilloscope by which is possible to observe the signal. This is the requirement in order to have, in the final measurement, a single high peak given by the sum of all the signals coming from the detectors. Each signal has been acquired for almost half of an hour, but the entire circuit has been maintained active for more time to observe its capacity to work for longer periods. The principal results of this thesis are given by the spectra of 12 detectors and the corresponding values of Voltages, FWHM and Resolution. The outcomes of the acquisitions show also another expected behavior: the strong dependence of the detectors from the temperature, demonstrating that an its change causes fluctuations in the signal. In turn, these fluctuations will affect the spectrum, resulting in a shifting of the curve and a lower Resolution. On the other hand, a measurement performed in stable conditions will lead to accordance between the nominal and experimental measurements, as for the detectors 10, 11 and 12 of our system.
Resumo:
Friction and triboelectrification of materials show a strong correlation during sliding contacts. Friction force fluctuations are always accompanied by two tribocharging events at metal-insulator [e.g., polytetrafluoroethylene (PTFE)] interfaces: injection of charged species from the metal into PTFE followed by the flow of charges from PTFE to the metal surface. Adhesion maps that were obtained by atomic force microscopy (AFM) show that the region of contact increases the pull-off force from 10 to 150 nN, reflecting on a resilient electrostatic adhesion between PTFE and the metallic surface. The reported results suggest that friction and triboelectrification have a common origin that must be associated with the occurrence of strong electrostatic interactions at the interface.
Resumo:
To assess binocular detection grating acuity using the LEA GRATINGS test to establish age-related norms in healthy infants during their first 3 months of life. In this prospective, longitudinal study of healthy infants with clear red reflex at birth, responses to gratings were measured at 1, 2, and 3 months of age using LEA gratings at a distance of 28 cm. The results were recorded as detection grating acuity values, which were arranged in frequency tables and converted to a one-octave scale for statistical analysis. For the repeated measurements, analysis of variance (ANOVA) was used to compare the detection grating acuity results between ages. A total of 133 infants were included. The binocular responses to gratings showed development toward higher mean values and spatial frequencies, ranging from 0.55 ± 0.70 cycles per degree (cpd), or 1.74 ± 0.21 logMAR, in month 1 to 3.11 ± 0.54 cpd, or 0.98 ± 0.16 logMAR, in month 3. Repeated ANOVA indicated differences among grating acuity values in the three age groups. The LEA GRATINGS test allowed assessment of detection grating acuity and its development in a cohort of healthy infants during their first 3 months of life.
Resumo:
A novel capillary electrophoresis method using capacitively coupled contactless conductivity detection is proposed for the determination of the biocide tetrakis(hydroxymethyl)phosphonium sulfate. The feasibility of the electrophoretic separation of this biocide was attributed to the formation of an anionic complex between the biocide and borate ions in the background electrolyte. Evidence of this complex formation was provided by (11) B NMR spectroscopy. A linear relationship (R(2) = 0.9990) between the peak area of the complex and the biocide concentration (50-900 μmol/L) was found. The limit of detection and limit of quantification were 15.0 and 50.1 μmol/L, respectively. The proposed method was applied to the determination of tetrakis(hydroxymethyl)phosphonium sulfate in commercial formulations, and the results were in good agreement with those obtained by the standard iodometric titration method. The method was also evaluated for the analysis of tap water and cooling water samples treated with the biocide. The results of the recovery tests at three concentration levels (300, 400, and 600 μmol/L) varied from 75 to 99%, with a relative standard deviation no higher than 9%.
Resumo:
Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the gold standard, and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture.
Resumo:
The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50μgcm(-2).