948 resultados para Safe
Resumo:
The research approaches recycling of urban waste compost (UWC) as an alternative fertilizer for sugarcane crop and as a social and environmental solution to the solids residuals growth in urban centers. A mathematical model was used in order to know the metal dynamics as decision support tool, aiming to establish of criteria and procedures for UWC's safe use, limited by the amount of heavy metal. A compartmental model was developed from experimental data in controlled conditions and partially checked with field data. This model described the heavy metal transference in the system soil-root-aerial portion of sugarcane plants and concluded that nickel was metal to be concern, since it takes approximately three years to be attenuated in the soil, reaching the aerial portions of the plant at high concentrations. Regarding factors such as clay content, oxide level and soil pH, it was observed that for soil with higher buffering capacity, the transfer of the majority of the metals was slower. This model may become an important tool for the attainment of laws regarding the UWC use, aiming to reduce environment contamination the waste accumulation and production costs.
Resumo:
OBJECTIVE: To evaluate the positive predictive value for BI-RADS (Breast Imaging Reporting and Data System) categories 3, 4 and 5, correlating mammographic and histological diagnosis in non-palpable breast lesions. MATERIALS AND METHODS: Analytical-descriptive study of 169 women submitted to stereotactic localization for surgical biopsy of non-palpable breast lesions. Mammographic and histological findings were correlated, analyzing the predictive positive value for each category. RESULTS: Forty-two (24.8%) cases were diagnosed with breast cancer - only one in category 3, 19 in category 4, and 22 in category 5. The positive predictive value for categories 3, 4A, 4B, 4C and 5 were, respectively, 3.4%, 10.3%, 11.3%, 36% and 91.7%. Microcalcifications were the most frequent finding related to malignancy, present in 61.5% of these cases. CONCLUSION: The present study has demonstrated that BI-RADS allows a safe prediction of high suspicion of malignancy in lesions category 5 and low suspicion for category 3. As regards the category 4, the positive predictive value has shown a progressive increase in subcategories A, B and C, demonstrating that this subclassification represents an invaluable contribution for a more detailed and accurate assessment of lesions suspicious for malignancy.
Resumo:
Purpose: To analyze the efficacy and safety of intraope-rative mitomycin C (MMC) in combined procedures (extra-capsular cataract extraction + trabeculectomy). Methods: Twenty-four patients were randomized to either MMC (0.5 mg/ml) (n = 14) or saline solution (n = 10) for 3 minutes during the combined procedure. Results: Twelve months after surgery, mean IOP in the MMC group (13.2 ± 2.9 mmHg) was significantly lower than in the control group (16.3 ± 3.9 mmHg) (p = 0.02). The mean number of medications used during the 12-month follow-up in the control group (1.33 ± 0.5) was significantly higher than in the MMC-treated group (0.5 ± 0.5) (p = 0.005). Life table analysis showed a significantly higher probability of IOP control in the MMC group than in the control group (p < 0.01). Conclusions: Intraoperative MMC is safe and effective in pro-moting a better IOP control and reducing the need for postoperative antiglaucoma medications. We suggest intraope-rative MMC to be routinely employed in combined procedures.
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
The purpose of this study was to evaluate the hydrogenionic potential and electrical conductivity of Portland cements and MTA, as well as the amount of arsenic and calcium released from these materials. In Teflon molds, samples of each material were agitated and added to plastic flasks containing distilled water for 3, 24, 72 and 168 h. The results were analyzed with a Kruskal-Wallis non-parametric test for global comparisons and a Dunn-Tukey test for pairwise comparisons. The results revealed no significant differences in the pH of the materials (p > 0.05). The electrical conductivity of the cements were not statistically different (p > 0.05). White non-structural cement and MTA BIO released the largest amount of calcium ions into solution (p < 0.05), while arsenic release was insignificant in all of the materials (p > 0.05). The results indicated that the physico-chemical properties of Portland cements and MTA were similar. Furthermore, all materials produced an alkaline environment and can be considered safe for clinical use because arsenic was not released. The electrical conductivity and the amount of calcium ions released into solution increased over time.
Resumo:
PURPOSE: Maxillary sinus lifting is a technique, in which, a possible complication is sinus membrane perforation. The aim of this study was to compare two techniques using ultrasound surgery to perform autogenous graft for maxillary sinus lifting. METHODS: Ten rabbits were used in the study, one of them did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side, and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were statistically compared. RESULTS: There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device from rabbit skulls. CONCLUSION: Assessment of operative procedures led to the conclusion that piezoelectric ultrasound was shown to be a safe tool in the surgical approach to the maxillary sinus of rabbits, allowing sinus membrane integrity to be maintained during surgical procedures.
Resumo:
The aim of this in vitro study was to evaluate the tensile bond strength of a self-etching adhesive system to three different dentinal substrates. Primary molar teeth that had been recently exfoliated (RE), with unknown time of exfoliation (UT), and extracted due to prolonged retention (PR) were used for this investigation. Ten primary molar teeth of each group were cut in the middle following the mesio-distal direction, creating a total of twenty specimens per group. The specimens were included in acrylic resin and had a flat dentin surface exposed. The self-etching adhesive system was applied to this surface and a 3-millimeter high cone with diameter of 2 mm in the adhesion area was constructed using composite resin. The specimens were stored in distilled water at 37ºC for 24 hours. Fifteen specimens of each substrate were used for the tensile bond test (n = 15) and 5 had the interface analyzed by scanning electron microscopy (SEM). The data was examined by one-way ANOVA and presented no significant differences between groups (p = 0.5787). The mean values obtained for RE, UT and PR were 18.39 ± 9.70, 19.41 ± 7.80, and 23.30 ± 9.37 MPa, respectively. Any dentinal substrates of primary teeth studied are safe for tensile bond strength tests with adhesive systems.
Resumo:
Current scientific knowledge provides clear evidence that alcohol-based mouthwashes can be beneficial in a daily oral health routine, including dental hygiene and plaque control. Several issues are worth discussing, in spite of the wealth of supporting evidence. Despite some undesirable effects to some people, like burning sensation, and some contraindications, like the use by infants, alcohol addicts and patients with mucosal injuries, there is no reason to avoid the use of alcohol-containing mouthwashes as long as they are used following proper guidance by dental professionals and the manufacturers' instructions. The alleged correlation between oral cancer and alcohol-based mouthrinses presents so little, weak, inconsistent and even contradictory evidence in the literature that any kind of risk warning to patients would be uncalled for. Antimicrobial mouthrinses are safe and effective in reducing plaque and gingivitis, and should be part of a comprehensive oral health care regimen that includes brushing, flossing and rinsing to prevent or minimize periodontal disease.
Resumo:
Para avaliar o efeito anestésico do óleo de cravo em lambaris (Astyanax altiparanae), cinco grupos de 30 alevinos (0,6±0,1g) foram expostos às concentrações de 50, 75, 100, 125 e 150mg L-1, medindo-se, respectivamente: tempo de indução à anestesia profunda (caracterizada pela perda de equilíbrio, pela ausência de natação, pela redução dos movimentos operculares e pelas respostas apenas a estímulos táteis mais intensos), tempo de recuperação e taxa de mortalidade após a exposição. Em uma segunda etapa (10 peixes/tratamento), registraram-se, para cada concentração, os tempos de indução e de recuperação após anestesia cirúrgica (movimentos operculares lentos e irregulares e perda de reações a estímulos), anotando-se a mortalidade após seis minutos de exposição. Observou-se redução linear no tempo de indução à anestesia (0,01min mg-1 de anestésico acrescido) e aumento quadrático do tempo de recuperação com a elevação da concentração (resposta máxima estimada em 7,1 minutos). A anestesia profunda foi alcançada em tempo inferior a 1,5 minuto para todas as concentrações, com recuperação mais rápida e sem mortalidade para 50mg L-1. Para indução à anestesia cirúrgica, foram registrados menores tempos nas concentrações 75 e 100mg L-1; porém, com mortalidade de 80% e 100%, respectivamente. A concentração 50mg L-1 promoveu anestesia cirúrgica e recuperação em 3,29±0,71 e 4,97±0,63 minutos, respectivamente, sem mortalidade. Concluiu-se que o óleo de cravo possui efeito anestésico para alevinos de lambari, sendo 50mg L-1 a concentração eficiente e segura para indução à anestesia profunda em até 1,5 minuto e de anestesia cirúrgica em até 3,3 minutos de exposição.
Resumo:
The aim of this study was to evaluate the viability of the use of spent laying hens' meat in the manufacturing of mortadella-type sausages with healthy appeal by using vegetable oil instead of animal fat. 120 Hy-line® layer hens were distributed in a completely randomized design into two treatments of six replicates with ten birds each. The treatments were birds from light Hy-line® W36 and semi-heavy Hy-line® Brown lines. Cold carcass, wing, breast and leg fillets yields were determined. Dry matter, protein, and lipid contents were determined in breast and leg fillets. The breast and legg fillets of three replicates per treatment were used to manufacture mortadella. After processing, sausages were evaluated for proximal composition, objective color, microbiological parameters, fatty acid profile and sensory acceptance. The meat of light and semi-heavy spent hens presented good yield and composition, allowing it to be used as raw material for the manufacture of processed products. Mortadellas were safe from microbiological point of view, and those made with semi-heavy hens fillets were redder and better accepted by consumers. Values for all sensory attributes were evaluated over score 5 (neither liked nor disliked). Both products presented high polyunsaturated fatty acid contents and good polyunsaturated to saturated fatty acid ratio. The excellent potential for the use of meat from spent layer hens of both varieties in the manufacturing of healthier mortadella-type sausage was demonstrated.
Resumo:
PURPOSE: Evaluate the bone tissue recovery following transplantation of ovine mesenchymal stem cells (MSC) from bone marrow and human immature dental-pulp stem cells (hIDPSC) in ovine model of induced osteonecrosis of femoral head (ONFH). METHODS: Eight sheep were divided in three experimental groups. First group was composed by four animals with ONFH induced by ethanol through central decompression (CD), for control group without any treatment. The second and third group were compose by two animals, six weeks after ONFH induction received transplantation of heterologous ovine MSC (CD + oMSC), and hIDPSC (CD + hIDPSC), respectively. In both experiments the cells were transplanted without application of any type of immunosupression protocol. RESULTS: Our data indicate that both cell types used in experiments were able to proliferate within injured site providing bone tissue recovery. The histological results obtained from CD+hIDPSC suggested that the bone regeneration in such animals was better than that observed in CD animals. CONCLUSION: Mesenchymal stem cell transplant in induced ovine osteonecrosis of femoral head by central decompression technique is safe, and apparently favors bone regeneration of damaged tissues.
Resumo:
INTRODUÇÃO: A Prótese Implantável de Condução Óssea (BAHA) consiste em uma excelente opção na reabilitação auditiva de pacientes com perda auditiva condutiva e mista uni ou bilateral, e sensorioneural unilateral. Tem sido uma alternativa vantajosa sobre os aparelhos de condução óssea convencionais e os aparelhos de amplificação sonora individuais (AASI) quando o uso dos mesmos fica impossibilitado pela presença de otite externa crônica de difícil controle clínico. OBJETIVO: Apresentar o primeiro caso de BAHA realizado no Brasil, após a autorização da ANVISA, para a reabilitação da perda auditiva mista com episódios de otite externa crônica. MÉTODO: Paciente do sexo feminino, 50 anos, com perda auditiva de grau moderado à direita e severo à esquerda, zumbido bilateral, decorrente de otosclerose, submetida a quatro cirurgias de estapedotomia e com impossibilidade de uso de AASI devido a otorreia e otalgia bilateral. A avaliação médica e audiológica indicaram o benefício do BAHA. Realizada a cirurgia e implantação do sistema BAHA, a paciente apresentou melhora significativa nos limiares audiométricos, na percepção e discriminação da fala, além de relatar extrema satisfação relacionada ao fator estético. COMENTÁRIOS FINAIS: O processo cirúrgico do BAHA é seguro, simples e rápido, proporcionando excelentes resultados audiológicos e alto grau de satisfação por parte dos pacientes.