993 resultados para Rudy, Gerard
Resumo:
The usual practice to study a large power system is through digital computer simulation. However, the impact of large scale use of small distributed generators on a power network cannot be evaluated strictly by simulation since many of these components cannot be accurately modelled. Moreover, the network complexity makes the task of practical testing on a physical network nearly impossible. This study discusses the paradigm of interfacing a real-time simulation of a power system to real-life hardware devices. This type of splitting a network into two parts and running a real-time simulation with a physical system in parallel is usually termed as power-hardware-in-the-loop (PHIL) simulation. The hardware part is driven by a voltage source converter that amplifies the signals of the simulator. In this paper, the effects of suitable control strategy on the performance of PHIL and the associated stability aspects are analysed in detail. The analyses are validated through several experimental tests using an real-time digital simulator.
Resumo:
In the electricity market environment, load-serving entities (LSEs) will inevitably face risks in purchasing electricity because there are a plethora of uncertainties involved. To maximize profits and minimize risks, LSEs need to develop an optimal strategy to reasonably allocate the purchased electricity amount in different electricity markets such as the spot market, bilateral contract market, and options market. Because risks originate from uncertainties, an approach is presented to address the risk evaluation problem by the combined use of the lower partial moment and information entropy (LPME). The lower partial moment is used to measure the amount and probability of the loss, whereas the information entropy is used to represent the uncertainty of the loss. Electricity purchasing is a repeated procedure; therefore, the model presented represents a dynamic strategy. Under the chance-constrained programming framework, the developed optimization model minimizes the risk of the electricity purchasing portfolio in different markets because the actual profit of the LSE concerned is not less than the specified target under a required confidence level. Then, the particle swarm optimization (PSO) algorithm is employed to solve the optimization model. Finally, a sample example is used to illustrate the basic features of the developed model and method.
Resumo:
A new small full bridge module for MMCC research is presented. Each full bridge converter cell is a single small (65 × 30 mm) multilayer PCB with two low voltage high current (22 V, 40 A) integrated half bridge ICs and the necessary isolated control signals and auxiliary power supply (2500 V isolation). All devices are surface mount, minimising cell height (4 mm) and parasitic inductance. Each converter cell can be physically stacked with PCB connectors propagating the control signals and inter-cell power connections. Many cells can be trivially stacked to create a large multilevel converter leg with isolated auxiliary power and control signals. Any of the MMCC family members is then easily formed. With a change in placement of stacking connector, a parallel connection of bridges is also possible. Operation of a nine level parallel full bridge is demonstrated at 12 V and 384 kHz switching frequency delivering a 30 W 2 kHz sinewave into a resistive load. A number of new applications for this novel module aside from MMCC development are listed.
Resumo:
To overcome the limitations of existing gate drive topologies an improved gate drive concept is proposed to provide fast, controlled switching of power MOSFETs. The proposed topology exploits the cascode configuration with the inclusion of an active gate clamp to ensure that the driven MOSFET may be turned off under all load conditions. Key operating principles and advantages of the proposed gate drive topology are discussed. Characteristic waveforms are investigated via simulation and experimentation for the cascode driver in an inductive switching application at 375V and 10A. Experimental waveforms compared well with simulations with long gate charging delays (including the Miller plateau) being eliminated from the gate voltage waveform.
Resumo:
A nine level modular multilevel cascade converter (MMCC) based on four full bridge cells is shown driving a piezoelectric ultrasonic transducer at 71 and 39 kHz, in simulation and experimentally. The modular cells are small stackable PCBs, each with two fully integrated surface mount 22 V, 40 A MOSFET half-bridge converters, and include all control signal and power isolation. In this work, the bridges operate at 12 V and 384 kHz, to deliver a 96 Vpp 9 level waveform with an effective switching frequency of 3 MHz. A 9 pH air cored inductor forms a low pass filter in conjunction with the 3000 pF capacitance of the transducer load. Eight equally phase-displaced naturally sampled pulse width modulation (PWM) drive signals, along with the modulating sinusoid, are generated using phase accumulation techniques in a dedicated FPGA. Experimental time domain and FFT plots of the multilevel and transducer output waveforms are presented and discussed.
Resumo:
An improved Phase-Locked Loop (PLL) for extracting phase and frequency of the fundamental component of a highly distorted grid voltage is presented. The structure of the single-phase PLL is based on the Synchronous Reference Frame (SRF) PLL and uses an All Pass Filter (APF) to generate the quadrature component from the single phase input voltage. In order to filter the harmonic content, a Moving Average Filter (MAF) is used, and performance is improved by designing a lead compensator and also a feed-forward compensator. The simulation results are compared to show the improved performance with feed-forward. In addition, the frequency dependency of MAF is dealt with by a proposed method for adaption to the frequency. This method changes the window size based on the frequency on a sample-by-sample basis. By using this method, the speed of resizing can be reduced in order to decrease the output ripples caused by window size variations.
Resumo:
Frequency domain spectroscopy (FDS) is being used to assess the insulation condition of oil–paper power transformers. However, it has to date only been implemented on de-energised transformers, which requires the transformers to be shut down for an extended period and may cause significant costs. To solve this issue, a newly improved monitoring method based on the FDS principle is proposed to implement the dielectric measurement on energised transformers. Moreover, a chirp waveform excitation and its novel processing method are introduced. Compared with the conventional FDS results, dielectric results from the energised insulation system have higher tanδ values because of the increased losses. To further understand the insulation ageing process, the effects of the geometric capacitance are removed from the measured imaginary admittance of the insulation system to enhance the ageing signature. The resulting imaginary admittance is then shown to correlate well with the central time constant in return voltage measurements results. The proposed methods address the issues on techniques used on energised transformers and provide a clue for on-line FDS diagnostic application.
Resumo:
Building healthcare resilience is an important step towards creating more resilient communities to better cope with future disasters. To date, however, there appears to be little literature on how the concept of healthcare resilience should be defined and operationalized with a conceptual framework. This article aims to build a comprehensive healthcare disaster management approach guided by the concept of resilience. Methods: Google and major health electronic databases were searched to retrieve critical relevant publications. A total of 61 related publications were included, to provide a comprehensive overview of theories and definitions relevant to disaster resilience. Results and Discussions: Resilience is an inherent and adaptive capacity to cope with future uncertainty, through multiple strategies with all hazards approaches, in an attempt to achieve a positive outcome with linkage and cooperation. Healthcare resilience can be defined as the capability of healthcare organisations to resist, absorb, and respond to the shock of disasters while maintaining the most essential functions, then recover to their original state or adapt to a new state. It can be assessed by criteria, namely: robustness, redundancy, resourcefulness; and a complex of key dimensions, namely: vulnerability and safety, disaster resources and preparedness, continuity of essential health services, recovery and adaptation. Conclusions: This new concept places healthcare organisations’ disaster capabilities, management tasks, activities and disaster outcomes together into a comprehensive whole view, using an integrated approach and establishing achievable goals.
Resumo:
Determining the condition as well as the remaining life of an insulation system is essential for the reliable operation of large oil-filled power transformers. Frequency-domain spectroscopy (FDS) is one of the diagnostic techniques used to identify the dielectric status of a transformer. Currently, this technique can only be implemented on a de-energized transformer. This paper presents an initial investigation into a novel online monitoring method based on FDS dielectric measurements for transformers. The proposed technique specifically aims to address the real operational constraints of online testing. This is achieved by designing an online testing model extending the basic “extended Debye” linear dielectric model and taking unique noise issues only experienced during online measurements into account via simulations. Approaches to signal denoising and potential problems expected to be encountered during online measurements will also be discussed. Using fixed-frequency sinusoidal excitation waveforms will result in a long measurement times. The use of alternatives such as a chirp has been investigated using simulations. The results presented in the paper predict that reliable measurements should be possible during online testing.
Resumo:
Background
With dwindling malaria cases in Bhutan in recent years, the government of Bhutan has made plans for malaria elimination by 2016. This study aimed to determine coverage, use and ownership of LLINs, as well as the prevalence of asymptomatic malaria at a single time-point, in four sub-districts of Bhutan.
Methods
A cross-sectional study was carried out in August 2013. Structured questionnaires were administered to a single respondent in each household (HH) in four sub-districts. Four members from 25 HH, randomly selected from each sub-district, were tested using rapid diagnostic tests (RDT) for asymptomatic Plasmodium falciparum and Plasmodium vivax infection. Multivariable logistic regression models were used to identify factors associated with LLIN use and maintenance.
Results
All blood samples from 380 participants tested negative for Plasmodium infections. A total of 1,223 HH (92.5% of total HH) were surveyed for LLIN coverage and use. Coverage of LLINs was 99.0% (1,203/1,223 HH). Factors associated with decreased odds of sleeping under a LLIN included: washing LLINs
Resumo:
Background Despite the importance of an effective health system response to various disasters, relevant research is still in its infancy, especially in middle- and low-income countries. Objective This paper provides an overview of the status of disaster health management in China, with its aim to promote the effectiveness of the health response for reducing disaster-related mortality and morbidity. Design A scoping review method was used to address the recent progress of and challenges to disaster health management in China. Major health electronic databases were searched to identify English and Chinese literature that were relevant to the research aims. Results The review found that since 2003 considerable progress has been achieved in the health disaster response system in China. However, there remain challenges that hinder effective health disaster responses, including low standards of disaster-resistant infrastructure safety, the lack of specific disaster plans, poor emergency coordination between hospitals, lack of portable diagnostic equipment and underdeveloped triage skills, surge capacity, and psychological interventions. Additional challenges include the fragmentation of the emergency health service system, a lack of specific legislation for emergencies, disparities in the distribution of funding, and inadequate cost-effective considerations for disaster rescue. Conclusions One solution identified to address these challenges appears to be through corresponding policy strategies at multiple levels (e.g. community, hospital, and healthcare system level).
Resumo:
Background The aim of this study is to examine the flood fatality with a view to identifying risks which may inform public policy responses to future flood. On July 21st, 2012, Beijing suffered the heaviest rain since 1963. The average rainfall was 215 mm over a 24 hour period in the central city (301mm in Fangshan District). The rain resulted in a flood that caused severe health, social and financial impact. Results This flood caused 79 deaths. Of the 71 deaths for which a specific cause could be identified, 5 were rescue team members, 42 were killed by drowning (11 in the car), and the others by electricity shock, fallen house, falling items and lightning. The total financial cost was estimated to be US$ 1.7 billion. The causations of the deaths inform the risks associated with the flood. Discussion This flood had a catastrophic impact on Beijing, mainly due to the intensity of the rain (the rain was the heaviest in the modern Beijing history; possibly due to global warming and urban heat island effect), the vulnerability of the infrastructure (poor standards of drainage, disorganized water management systems and decreased permeability of the earth as a result of the city’s rapid development), and the capacity of the response system (mainly dependent on the awareness of the citizens, warning systems and the capacity of the emergency rescue). Implication Many risk management measures have been implemented as a result of this flood, including water level warning marks, flood safety education and warnings sent to mobile phones, a project to move about 74,500 farmers away from the flood-prone areas within 5 years. However, further measures targeted at the fundamental issues identified by this analysis are necessary, especially those targeting at health issues. These may include better planning, improved drainage systems and ecological development to increase permeability etc..
Resumo:
Sleep loss, widespread in today’s society and associated with a number of clinical conditions, has a detrimental effect on a variety of cognitive domains including attention. This study examined the sequelae of sleep deprivation upon BOLD fMRI activation during divided attention. Twelve healthy males completed two randomized sessions; one after 27 h of sleep deprivation and one after a normal night of sleep. During each session, BOLD fMRI was measured while subjects completed a cross-modal divided attention task (visual and auditory). After normal sleep, increased BOLD activation was observed bilaterally in the superior frontal gyrus and the inferior parietal lobe during divided attention performance. Subjects reported feeling significantly more sleepy in the sleep deprivation session, and there was a trend towards poorer divided attention task performance. Sleep deprivation led to a down regulation of activation in the left superior frontal gyrus, possibly reflecting an attenuation of top-down control mechanisms on the attentional system. These findings have implications for understanding the neural correlates of divided attention and the neurofunctional changes that occur in individuals who are sleep deprived.
Resumo:
BreastScreen Queensland (BSQ) is a government-based health service that provides free breast cancer screening services to eligible women using digital mammography technology.' In 2007, BSQ launched its first social marketing campaign' aimed at achieving a 30 per cent increase in women's programme participation by addressing the barriers to regular screening and by dispelling myths about breast cancer (Tornabene 2010). 'The Facts' mass media social marketing campaign used a credible spokesperson, Australian journalist]ana Wendt, to deliver the call to action' Don't make excuses. Make an appointment'.