952 resultados para Pulse Measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. PARTICIPANTS AND METHODS: Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. RESULTS: The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). CONCLUSIONS: Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leprosy is an infectious and contagious spectral disease accompanied by a series of immunological events triggered by the host response to the aetiologic agent, Mycobacterium leprae . The induction and maintenance of the immune/inflammatory response in leprosy are linked to multiple cell interactions and soluble factors, primarily through the action of cytokines. The purpose of the present study was to evaluate the serum levels of tumour necrosis factor (TNF)-α and its soluble receptors (sTNF-R1 and sTNF-R2) in leprosy patients at different stages of multidrug treatment (MDT) in comparison with non-infected individuals and to determine their role as putative biomarkers of the severity of leprosy or the treatment response. ELISA was used to measure the levels of these molecules in 30 healthy controls and 37 leprosy patients at the time of diagnosis and during and after MDT. Our results showed increases in the serum levels of TNF-α and sTNF-R2 in infected individuals in comparison with controls. The levels of TNF-α, but not sTNF-R2, decreased with treatment. The current results corroborate previous reports of elevated serum levels of TNF-α in leprosy and suggest a role for sTNF-R2 in the control of this cytokine during MDT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Landscape is an example of a non-market good where no metrics exist to measure its quality. The paper proposes an original methodology to nevertheless estimate scope variables in those circumstances, allowing then to better test if people's willingnesstopay for such good is sensitive to the scope. The methodology is based on techniques developed in the context of multicriteria decision analysis. It is applied to assess the quality of the landscape of several Swiss alpine resorts. This assessment is then used as an explanatory variable in a hedonic price function to explain the rent of apartments and to derive an implicit price of the landscape quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PROPÒSIT: Estudiar l'efecte de la cirurgia LASIK en la llum dispersa i la sensibilitat al contrast. MÈTODES: Vint-i-vuit pacients van ser tractats amb LASIK. La qualitat visual es va avaluar abans de l'operació i dos mesos després. RESULTATS: La mitjana de llum dispersa i la sensibilitat al contrast abans de l'operació no va canviar en dos mesos després. Només un ull tenia un marcat augment en la llum dispersa. Nou ulls van presentar una lleugera disminució en la sensibilitat al contrast. S'han trobat dues complicacions. CONCLUSIÓ: Després de LASIK la majoria dels pacients (80%) no van tenir complicacions i van mantenir la seva qualitat visual. Uns pocs pacients (16%) van tenir una mica de qualitat visual disminuïda. Molt pocs (4%) van tenir complicacions clíniques amb disminució en la qualitat visual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In epidemiologic studies, measurement error in dietary variables often attenuates association between dietary intake and disease occurrence. To adjust for the attenuation caused by error in dietary intake, regression calibration is commonly used. To apply regression calibration, unbiased reference measurements are required. Short-term reference measurements for foods that are not consumed daily contain excess zeroes that pose challenges in the calibration model. We adapted two-part regression calibration model, initially developed for multiple replicates of reference measurements per individual to a single-replicate setting. We showed how to handle excess zero reference measurements by two-step modeling approach, how to explore heteroscedasticity in the consumed amount with variance-mean graph, how to explore nonlinearity with the generalized additive modeling (GAM) and the empirical logit approaches, and how to select covariates in the calibration model. The performance of two-part calibration model was compared with the one-part counterpart. We used vegetable intake and mortality data from European Prospective Investigation on Cancer and Nutrition (EPIC) study. In the EPIC, reference measurements were taken with 24-hour recalls. For each of the three vegetable subgroups assessed separately, correcting for error with an appropriately specified two-part calibration model resulted in about three fold increase in the strength of association with all-cause mortality, as measured by the log hazard ratio. Further found is that the standard way of including covariates in the calibration model can lead to over fitting the two-part calibration model. Moreover, the extent of adjusting for error is influenced by the number and forms of covariates in the calibration model. For episodically consumed foods, we advise researchers to pay special attention to response distribution, nonlinearity, and covariate inclusion in specifying the calibration model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Patients with non-insulin-dependent diabetes mellitus (NIDDM) are at increased cardiovascular risk due to an accelerated atherosclerotic process. The present study aimed to compare skin microvascular function, pulse wave velocity (PWV), and a variety of hemostatic markers of endothelium injury [von Willebrand factor (vWF), plasminogen activator inhibitor-1 (PAI-1), tissue plasminogen activator (t-PA), tissue factor pathway inhibitor (TFPI), and the soluble form of thrombomodulin (s-TM)] in patients with NIDDM. METHODS: 54 patients with NIDDM and 38 sex- and age-matched controls were studied. 27 diabetics had no overt micro- and/or macrovascular complications, while the remainder had either or both. The forearm skin blood flow was assessed by laser-Doppler imaging, which allowed the measurement of the response to iontophoretically applied acetylcholine (endothelium-dependent vasodilation) and sodium nitroprusside (endothelium-independent vasodilation), as well as the reactive hyperemia triggered by the transient occlusion of the circulation. RESULTS: Both endothelial and non-endothelial reactivity were significantly blunted in diabetics, regardless of the presence or the absence of vascular complications. Plasma vWF, TFPI and s-TM levels were significantly increased compared with controls only in patients exhibiting vascular complications. Concentrations of t-PA and PAI-1 were significantly increased in the two groups of diabetics versus controls. CONCLUSION: In NIDDM, both endothelium-dependent and -independent microvascular skin reactivity are impaired, whether or not underlying vascular complications exist. It also appears that microvascular endothelial dysfunction is not necessarily associated in NIDDM with increased circulating levels of hemostatic markers of endothelial damage known to reflect a hypercoagulable state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies have shown that obesity is associated with chronic kidney disease and end stage renal disease. These studies have used creatinine derived equations to estimate glomerular filtration rate (GFR) and have indexed GFR to body surface area (BSA). However, the use of equations using creatinine as a surrogate marker of glomerular filtration and the indexation of GFR for BSA can be questioned in the obese population. First, these equations lack precision when they are compared to gold standard GFR measurements such as inulin clearances; secondly, the indexation of GFR for 1.73 m(2) of BSA leads to a systematic underestimation of GFR compared to absolute GFR in obese patients who have BSA that usually exceed 1.73 m(2). Obesity is also associated with pathophysiological changes that can affect the pharmacokinetics of drugs. The effect of obesity on both renal function and drug pharmacokinetics raises the issue of correct drug dosage in obese individuals. This may be particularly relevant for drugs known to have a narrow therapeutic range or excreted by the kidney.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perfusion CT studies of regional cerebral blood flow (rCBF), involving sequential acquisition of cerebral CT sections during IV contrast material administration, have classically been reported to be achieved at 120 kVp. We hypothesized that using 80 kVp should result in the same image quality while significantly lowering the patient's radiation dose, and we evaluated this assumption. In five patients undergoing cerebral CT survey, one section level was imaged at 120 kVp and 80 kVp, before and after IV administration of iodinated contrast material. These four cerebral CT sections obtained in each patient were analyzed with special interest to contrast, noise, and radiation dose. Contrast enhancement at 80 kVp is significantly increased (P < .001), as well as contrast between gray matter and white matter after contrast enhancement (P < .001). Mean noise at 80 kVp is not statistically different (P = .042). Finally, performance of perfusion CT studies at 80 kVp, keeping mAs constant, lowers the radiation dose by a factor of 2.8. We, thus, conclude that 80 kVp acquisition of perfusion CT studies of rCBF will result in increased contrast enhancement and should improve rCBF analysis, with a reduced patient's irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 58 newborn infants a new iridium oxide sensor was evaluated for transcutaneous carbon dioxide (tcPCO2) monitoring at 42 degrees C with a prolonged fixation time of 24 hours. The correlation of tcPCO2 (y; mm Hg) v PaCO2 (x; mm Hg) for 586 paired values was: y = 4.6 + 1.45x; r = .89; syx = 6.1 mm Hg. The correlation was not influenced by the duration of fixation. The transcutaneous sensor detected hypocapnia (PaCO2 less than 35 mm Hg) in 74% and hypercapnia (PCO2 greater than 45 mm Hg) in 74% of all cases. After 24 hours, calibration shifts were less than 4 mm Hg in 90% of the measuring periods. In 86% of the infants, no skin changes were observed; in 12% of infants, there were transitional skin erythemas and in 2% a blister which disappeared without scarring. In newborn infants with normal BPs, continuous tcPCO2 monitoring at 42 degrees C can be extended for as many as 24 hours without loss of reliability or increased risk for skin burns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Dynamics is a central aspect of ski jumping, particularly during take-off and stable flight. Currently, measurement systems able to measure ski jumping dynamics (e.g. 3D cameras, force plates) are complex and only available in few research centres worldwide. This study proposes a method to determine dynamics using a wearable inertial sensor-based system which can be used routinely on any ski jumping hill. The system automatically calculates characteristic dynamic parameters during take-off (position and velocity of the centre of mass perpendicular to the table, force acting on the centre of mass perpendicular to the table and somersault angular velocity) and stable flight (total aerodynamic force). Furthermore, the acceleration of the ski perpendicular to the table was quantified to characterise the skis lift at take-off. The system was tested with two groups of 11 athletes with different jump distances. The force acting on the centre of mass, acceleration of the ski perpendicular to the table, somersault angular velocity and total aerodynamic force were different between groups and correlated with the jump distances. Furthermore, all dynamic parameters were within the range of prior studies based on stationary measurement systems, except for the centre of mass mean force which was slightly lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMEDurant la phase de récupération d'un exercice de course à pied d'intensité maximale ou submaximale, une augmentation de la pression artérielle systolique centrale (aortique) résultant de la réflexion des ondes de pouls sur l'arbre vasculaire est constatée chez l'individu en bonne santé. En diastole cependant, l'impact de la réflexion de ces ondes de pouls sur la pression centrale demeure inconnu durant la récupération d'un exercice.Nous avons évalué les ondes de pouls centrales systolique et diastolique chez onze athlètes d'endurance durant la phase de récupération d'un exercice de course à pied dans des conditions d'effort maximal (sur tapis de course) et lors d'un effort submaximal lors d'une course à pied de 4000 mètres en plein air sur terrain mixte.Pour chaque sujet et lors des deux exercices, l'onde de pouls a été mesurée au niveau radial par tonométrie d'aplanation durant une phase de repos précédant l'exercice, puis à 5, 15, 25, 35 et 45 minutes après la fin de l'exercice. En utilisant une fonction mathématique de transfert, l'onde de pouls centrale a été extrapolée à partir de l'onde de pouls radiale. En compilant la forme de l'onde de pouls centrale avec une mesure simultanée de la pression artérielle brachiale, un index d'augmentation de l'onde de pouls en systole (Alx) et en diastole (Als) peut être calculé, reflétant l'augmentation des pressions résultant de la réflexion des ondes sur l'arbre vasculaire périphérique.A 5 minutes de la fin de l'exercice, les deux index ont été mesurés moindres que ceux mesurés lors de la phase précédant celui-ci. Lors des mesures suivantes, Alx est resté bas, alors que Aid a progressivement augmenté pour finalement dépasser la valeur de repos après 45 minutes de récupération. Le même phénomène a été constaté pour les deux modalités d'exercice (maximal ou submaximal). Ainsi, au-delà de quelques minutes de récupération après un exercice de course d'intensité maximale ou submaximale, nous avons montré par ces investigations que les ondes de pouls réfléchies en périphérie augmentent de façon sélective la pression centrale en diastole chez l'athlète d'endurance.ABSTRACTDuring recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 minutes after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (Alx) and a diastolic index (Aid) of pressure augmentation by reflections. At 5 minutes, both indices were below preexercise. At further time-points, Alx remained low, while Aid progressively increased, to overshoot above preexercise at 45 minutes. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance- trained athletes.