989 resultados para Prosthesis coloring


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives were to develop and evaluate an assistive technology for the use of the male condom by visually impaired men. It was a technology development study with the participation of seven subjects. Three workshops were performed between April and May of 2010; they were all filmed and the statements of the participants were transcribed and analyzed by content. Three categories were established: Sexuality of the visually impaired; Utilization of the text, For avoiding STDs, condoms we will use, divided in two subcategories, Concept discussion and Text evaluation; and Construction of a simple penile prosthesis. The knowledge transmitted related to STD, the utilization of the condom on the penile prosthesis made by the subjects themselves, and the interaction during the workshops were effective factors for the study. In the context of sexual health, the necessity of developing works involving the visually impaired was noted, addressing sexually transmitted diseases and focusing on the use of the condom by this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To analyze components of the deposits in the corneal flap interface of granular corneal dystrophy type II (GCD II) patients after laser in situ keratomileusis (LASIK). METHODS: Four corneal GCD II specimens displaying disease exacerbation after LASIK were analyzed. Three of these specimens included the recipient corneal button after penetrating keratoplasty or deep lamellar keratoplasty for advanced GCD II after LASIK. The fourth specimen, a similar case of GCD II after LASIK, included the amputated corneal flap. Specimens were processed for histopathologic and immunohistochemical analyses. RESULTS: Corneal stromal deposits in the LASIK flaps of all specimens were stained with 3 anti-transforming growth factor-beta-induced protein (TGFBIp) antibodies. The deposits displayed bright red color staining with Masson trichrome; however, negative staining was seen with Congo red, suggesting that hyaline is the main component localizing to the TGFBIp deposits rather than amyloid. CONCLUSIONS: Amorphous granular material deposited along the interface of the LASIK flap in GCD II corneas is composed mainly of hyaline deposits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The indication for pulmonary artery banding is currently limited by several factors. Previous attempts have failed to produce adjustable pulmonary artery banding with reliable external regulation. An implantable, telemetrically controlled, battery-free device (FloWatch) developed by EndoArt SA, a medical company established in Lausanne, Switzerland, for externally adjustable pulmonary artery banding was evaluated on minipigs and proved to be effective for up to 6 months. The first human implant was performed on a girl with complete atrioventricular septal defect with unbalanced ventricles, large patent ductus arteriosus and pulmonary hypertension. At one month of age she underwent closure of the patent ductus arteriosus and FloWatch implantation around the pulmonary artery through conventional left thoracotomy. The surgical procedure was rapid and uneventful. During the entire postoperative period bedside adjustments (narrowing or release of pulmonary artery banding with echocardiographic assessment) were repeatedly required to maintain an adequate pressure gradient. The early clinical results demonstrated the clinical benefits of unlimited external telemetric adjustments. The next step will be a multi-centre clinical trial to confirm the early results and adapt therapeutic strategies to this promising technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have recently shown that immunophotodetection of human colon carcinomas in nude mice and in patients is possible by using anti-carcinoembryonic antigen monoclonal antibodies (MAb) coupled to fluorescein. The most common clinical application of photodiagnosis has been for the detection of squamous cell carcinomas (SCC) in the upper respiratory tract, but the free dyes used have a poor tumor selectivity. We selected the known MAb E48 directed against SCC and coupled it to a fluorescent dye: indopentamethinecyanin (indocyanin). This dye has an advantage over fluorescein in that it emits a more penetrating fluorescent red signal at 667 nm after excitation with a laser ray of 640 nm. In vitro, an conjugate with an indocyanin:MAb molar ratio of 2, and an additional trace labeling with 125I, showed more than 80% of binding to cells from the SCC line A431. In vivo, when injected i.v. into nude mice bearing xenografts of the same carcinoma line, the MAb E48-(indocyanin)2 conjugate was almost as efficient as the unconjugated MAb E48 in terms of specific tumor localization: 15% of the injected dose per g of tumor at 24 h after injection and a tumor:overall normal tissue ratio of 6-8. There was no selective tumor localization of an irrelevant IgG1-(indocyanin)2 conjugate. Immunophotodetection of the s.c. SCC xenografts on mice given injections of 100 micrograms of MAb E48-(indocyanin), conjugate (representing 1 microgram of indocyanin) was performed at 24 h. Upon laser irradiation, clearly detectable red fluorescence from the indocyanin-MAb conjugate was observed specifically in the SCC xenografts across the mouse skin. In comparison, injection of 100 micrograms of a MAb E48 coupled to 2 micrograms of fluorescein gave a specific green fluorescence signal in the tumor xenografts, which was detectable, however, only after removing the mouse skin. Injection i.v. of a 15 times higher amount of free indocyanin (15 micrograms) gave a diffuse red fluorescence signal all over the mouse body with no definite increase in intensity in the tumor, indicating a lack of tumor selectivity of the free dye. The results demonstrate the possibility of broadening and improving the efficiency of tumor immunophotodiagnosis by coupling to a MAb directed against SCC, a fluorescent dye absorbing and emitting at higher wavelength than fluorescein, and thus having deeper tissue penetration and lower tissue autofluorescence. Such a demonstration opens the way to a new form of clinical immunophotodiagnosis and possibly to the development of a more specific approach to phototherapy of early bronchial carcinomas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine the risks of prosthesis dislocation, postoperative Trendelenburg gait, and sciatic nerve palsy after a posterior approach compared to a direct lateral approach for adult patients undergoing total hip arthroplasty (THA) for primary osteoarthritis (OA). METHODS: Medline, Embase, CINHAL, and Cochrane databases were searched until August 2003. All published trials comparing posterior and direct lateral surgical approaches to THA in adults with a diagnosis of primary hip osteoarthritis were collected. Retrieved articles were assessed independently for their methodological quality. RESULTS: Four prospective cohort studies involving 241 participants met the inclusion criteria. Regarding dislocation rate, no significant difference between posterior and direct lateral surgical approach was found (relative risk 0.35). The presence of postoperative Trendelenburg gait was not significantly different between surgical approaches. The risk of nerve palsy or injury was significantly higher with the direct lateral approach (relative risk 0.16). However, there were no significant differences when comparing this risk nerve by nerve, in particular for the sciatic nerve. Of the other outcomes considered, only the average range of internal rotation in extension of the hip was significantly higher (weighted mean difference 16 degrees ) in the posterior approach group (mean 35 degrees, SD 13 degrees ) compared to the direct lateral approach (mean 19 degrees, SD 13 degrees ). CONCLUSION: The quality and quantity of information extracted from the trials performed to date are insufficient to make a firm conclusion on the optimum choice of surgical approach for adult patients undergoing primary THA for OA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is a long-term analysis of a group of patients with infected arthroplasties of the hip or the knee. We identified 28 patients with an infected arthroplasty (22 hips, 6 knees) documented by bacterial culture or on direct examination. At the time of diagnosis and on follow-up (a mean of 46 months after treatment) we evaluated the clinical picture, the radiological appearances of the articulation and the biological parameters. 19/28 patients showed a typical clinical picture, whereas in 9 others the picture was more doubtful. The treatments were 14 two-stage replacements of the arthroplasties, 7 simple resections, 5 conservative treatments and 2 one-stage replacements. On follow-up, 25 patients were considered as cured of their infection and 3 as failures. From a functional viewpoint, 9 patients showed no limitation, whereas 19 were limited in the daily activity. Half of the patients had no pain. Radiology showed that 20/26 evaluated patients had no signs of recurrence. Paraclinical examinations are important in the diagnosis of persistent low grade infections, particularly the demonstration of bacteria by pre-surgical sampling (fine needle aspiration, culture from draining sinuses). In spite of the cure of infection, the functional and painful sequellae are often considerable. As a result of our experience, we recommend a two-stage surgical procedure. Only when the general condition of the patient is poor, or when the infection is not under control, would we envisage an alternative procedure (arthrodesis, girdelstone, conservative).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

HYPOTHESIS: Supraspinatus deficiency associated with total shoulder arthroplasty (TSA) provokes eccentric loading and may induce loosening of the glenoid component. A downward inclination of the glenoid component has been proposed to balance supraspinatus deficiency. METHODS: This hypothesis was assessed by a numeric musculoskeletal model of the glenohumeral joint during active abduction. Three cases were compared: TSA with normal muscular function, TSA with supraspinatus deficiency, and TSA with supraspinatus deficiency and downward inclination of the glenoid. RESULTS: Supraspinatus deficiency increased humeral migration and eccentric loading. A downward inclination of the glenoid partly balanced the loss of stability, but this potential advantage was counterbalanced by an important stress increase within the glenoid cement. The additional subchondral bone reaming required to incline the glenoid component indeed reduced the bone support, increasing cement deformation and stress. CONCLUSION: Glenoid inclination should not be obtained at the expense of subchondral bone support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Retinal angiomatous proliferation (RAP) is a distinct variant of neovascular age-related macular degeneration (AMD). The aim of this study is to evaluate the functional and anatomic outcome after intravitreal ranibizumab (Lucentis) treatment in patients with RAP. METHODS: Prospective study of consecutive patients with newly diagnosed or recurrent RAP treated with intravitreal ranibizumab at the Jules Gonin Eye Hospital between March 2006 and December 2007. Baseline and monthly follow-up visits included best-corrected visual acuity (BCVA), fundus exam and optical coherence tomography. Fluorescein and indocyanine green angiography were performed at baseline and repeated at least every 3 months. RESULTS: Thirty-one eyes of 31 patients were treated with 0.5 mg of intravitreal ranibizumab for RAP between March 2006 and December 2007. The mean age of the patients was 82.6 years (SD:4.9). The mean number of intravitreal injections administered for each patient was 5 (SD: 2.4, range 3 to 12). The mean follow up was 13.4 months (SD: 3, range 10 to 22). The baseline mean logMAR BCVA was 0.72 (SD: 0.45) (decimal equivalent of 0.2). The mean logMAR BCVA was improved significantly (P &lt; 0.0001) at the last follow-up to 0.45, SD: 0.3 (decimal equivalent 0.35). The visual acuity (VA) improved by a mean of 2.7 lines (SD 2.5). Mean baseline central macular thickness (CMT) was 376 microm, and decreased significantly to a mean of 224 microm (P &lt; 0.001) at the last follow-up. Mean reduction of CMT was 152 microm (SD: 58). An average of 81.5% of the total visual improvement and 85% of the total CMT reduction occurred during the first post-operative month after one intravitreal injection of ranibizumab. During follow-up, an RPE tear occurred in one eye (3.2%) of the study group. No injection complications or systemic drug-related side-effects were noted during the follow-up period. CONCLUSIONS: Intravitreal ranibizumab injections appeared to be an effective and safe treatment for RAP, resulting in visual gain and reduction in macular thickness. Further long-term studies to evaluate the efficacy of intravitreal ranibizumab in RAP are warranted.