998 resultados para Preferência manual - Hand preference


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento, Ciências do Mar (Ecologia Marinha)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basic function of the human hand is the manipulation and grasping of various objects in all daily activities, including work activities. This is greatly influenced by strength and manual dexterity. However age, gender and other contexts such as work or leisure activities could influence strength. Handgrip strength, a measure of maximum voluntary force of the hand, has proved to be reliable and valid as an objective parameter to evaluate the functional integrity of the hand as part of the musculoskeletal system. It correlates highly with strength in other muscular groups and is therefore considered as a good indicator of overall muscular strength and functional stress and could be used as a predictor of physical disability. Handgrip strength assessment is simple and reliable and used commonly by several investigators and health professionals, in different contexts (medical, nutritional, rehabilitation, professional settings, engineering, etc.) and with different purposes (research, diagnostic, assessment, etc.). In clinical and rehabilitation settings is of vital importance in the determination of effectiveness of several interventions and for monitoring evolution of diseases. Various ways (methods, techniques and equipments) of collecting information on grip strength have been reported. This chapter will review basic concepts on handgrip function, methodologies of assessment, contexts of application and correlates, such as physical activity, health or nutritional status. Several populations and reference values as also the relationships between handgrip and clinical status, aging, risk of disability and diseases, will be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado em Ciências Económicas e Empresariais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objectivo deste trabalho era a determinação da influência das condições de armazenamento do biodiesel nas suas propriedades e composição. Para isso foi produzido biodiesel a partir de óleo alimentar usado e armazenado em diferentes condições. O biodiesel foi colocado em frascos de vidro e dividido em três grupos diferentes de temperatura. O primeiro foi colocado a uma temperatura de 6ºC (frigorifico) com frascos fechados e expostos ao ar e água. O segundo grupo foi colocado a uma temperatura de 40ºC (banho termostático) com frascos fechados, abertos ao ar e abertos ao ar e água. O terceiro e ultimo grupo foi colocado à temperatura ambiente (18,6-se que para as amostras armazenadas a 40ºC e expostas a ar e água, o índice de acidez e viscosidade aumentaram, enquanto o teor de ésteres totais diminuiu. Já o índice de peróxidos aumentou inicialmente, até atingir um valor máximo, apresentando de seguida uma tendência decrescente. O aumento inicial corresponde à formação de hidroperóxidos, já o declínio provavelmente corresponderá à sua degradação e formação de compostos como aldeídos. Os aldeídos por sua vez oxidam e dão origem a ácidos, justificando assim o aumento do índice de acidez. Este índice pode aumentar também devido à hidrólise dos ésteres causada pela presença de água, dando origem a álcoois e ácidos. Em contrapartida para as amostras armazenadas a temperaturas mais baixas os parâmetros mantiveram-se praticamente constantes ao longo do tempo. O índice de iodo não permitiu concluir claramente que houve uma diminuição nas ligações duplas como seria espectável. Ao analisar os cromatogramas obtidos na determinação dos ésteres das amostras armazenadas em contacto com ar e água, a 40ºC verifica-se a formação de ácidos gordos a partir dos 81 dias de armazenamento. Com os resultados obtidos verificou-se que para as amostras colocadas a 40ºC e em contacto com ar e água a taxa de oxidação é mais acelerada, fazendo com que o biodiesel perca as características e propriedades iniciais, já no caso das amostras armazenadas a 6ºC e em frascos fechados verifica-se que os parâmetros estudados praticamente não sofrem alterações, mantendo quase inalteradas as propriedades e composição do biodiesel ao fim das 16 semanas de estudo. Assim é possível concluir que para se conseguir manter as características e propriedades do biodiesel durante um armazenamento prolongado é necessário garantir um ambiente fresco de preferência inerte e depósitos completamentos secos, de forma a evitar as condições que provocam oxidação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo enquadra-se no âmbito do Marketing e Comportamento do Consumidor e tem como tema Promoção no Ponto de Venda. Esta investigação tem como objectivo conhecer a percepção e comportamento de grupos de consumidores face a promoções no ponto de venda. O desenvolvimento deste projecto procurou encontrar resposta para os objectivos de investigação propostos através da realização de um inquérito por questionário. Toda a investigação empírica teve por base os resultados obtidos através de 156 questionários online a consumidores, maiores de 18 anos, de super e hipermercados e centros comerciais. Foi utilizada uma amostra por conveniência, para a qual foi enviado questionário online através de email e redes sociais. Realizou-se então este estudo e os resultados demonstraram que as promoções continuam a motivar o consumo e a despoletar a compra imediata e em maior quantidade. Estas conclusões são diferenciadas face às categorias de produto, com maior interesse por parte do consumidor em relação às promoções nos bens essenciais e moda, e face às tipologias de promoção, cuja preferência de promoção são as que têm incidência no preço. No nosso estudo encontramos quatro segmentos de consumidores, que de uma forma global registam auto percepção de consumidores inteligentes, que procuram com a promoções optimizar a relação qualidade preço, e que são pouco impulsivos no consumo. Concluímos que as promoções no ponto de venda são técnicas de marketing em que os gestores de marketing devem continuar a apostar pois é um factor critico de sucesso no incremento de vendas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Auditoria

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Ciências Económicas e Empresariais, 9 Dezembro de 2015 , Universidade dos Açores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta dissertação, que foi desenvolvida no seio da Divisão de Equipamento Industrial (DEI) da empresa Toyota Caetano Portugal, S.A. (TCAP), consiste na análise do processo de atendimento a clientes, a partir de uma investigação efectuada no escritório oficinal (EO) do sector Após-Venda Empilhadores (AVE). A recolha de dados, bem como o acompanhamento do processo de atendimento a clientes, têm como objectivo perceber quais as principais dificuldades do processo, para posteriormente ser definida a estratégia a utilizar no sentido de combater os pontos críticos do relacionamento com os clientes. Esta investigação permitiu identificar várias dificuldades no registo de pedidos de assistência, na pesquisa de informação e também no acesso aos dados pelo cliente. Assim, foi criado um protótipo informático com capacidade para dar resposta às deficiências identificadas. Foram analisados os requisitos necessários para o sistema de informação de suporte e transformado o processo de tratamento de dados (pedidos de assistência, pesquisas, acessos…), até aqui manual, num processo automático, inovador e acima de tudo funcional. Pretende-se desta forma, oferecer um serviço de confiança aos clientes gerando uma lealdade duradoura e acrescentar valor à empresa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate effects of different manual techniques on cervical ranges of 17 motion and pressure pain sensitivity in subjects with latent trigger point of the upper trapezius muscle. 18 Methods: One hundred seventeen volunteers, with a unilateral latent trigger point on upper trapezius due to computer 19 work, were randomly divided into 5 groups: ischemic compression (IC) group (n = 24); passive stretching group (n = 20 23); muscle energy technique group (n = 23); and 2 control groups, wait-and-see group (n = 25) and placebo group 21 (n = 22). Cervical spine range of movement was measured using a cervical range of motion instrument as well as 22 pressure pain sensitivity by means of an algometer and a visual analog scale. Outcomes were assessed pretreatment, 23 immediately, and 24 hours after the intervention and 1 week later by a blind researcher. A 4 × 5 mixed repeated- 24 measures analysis of variance was used to examine the effects of the intervention and Cohen d coefficient was used. 25 Results: A group-by-time interaction was detected in all variables (P b .01), except contralateral rotation. The 26 immediate effect sizes of the contralateral flexion, ipsilateral rotation, and pressure pain threshold were large for 3 27 experimental groups. Nevertheless, after 24 hours and 1 week, only IC group maintained the effect size. 28 Conclusions: Manual techniques on upper trapezius with latent trigger point seemed to improve the cervical range of 29 motion and the pressure pain sensitivity. These effects persist after 1 week in the IC group. (J Manipulative Physiol 301 Ther 2013;xx:1-10)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A aquisição de competências ao nível da compreensão na leitura apresenta-se, cada vez mais, como o caminho para chegar ao conhecimento. O tipo de texto que se assume como o meio privilegiado de acesso ao conhecimento é o texto expositivo. Como tal, é importante que os textos a que os alunos têm acesso diariamente na sala de aula (nomeadamente, os textos dos manuais) sejam adequados ao desenvolvimento dessas competências. Neste estudo,analisaram-se os textos expositivos do manual de Estudo do Meio do 4.º ano mais adotado em Portugal no ano letivo 2010/2011. Em concreto, apurou-se a percentagem de textos expositivos existentes no manual, analisou-se a sua estrutura (Meyer, 1985), o tipo de questões que os acompanham, bem como as relações entre as perguntas e as respostas (Raphael, 1986, cit. em Giasson, 2000). O manual foi ainda analisado à luz do que é preconizado pelos documentos oficiais do Ministério da Educação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sendo uma forma natural de interação homem-máquina, o reconhecimento de gestos implica uma forte componente de investigação em áreas como a visão por computador e a aprendizagem computacional. O reconhecimento gestual é uma área com aplicações muito diversas, fornecendo aos utilizadores uma forma mais natural e mais simples de comunicar com sistemas baseados em computador, sem a necessidade de utilização de dispositivos extras. Assim, o objectivo principal da investigação na área de reconhecimento de gestos aplicada à interacção homemmáquina é o da criação de sistemas, que possam identificar gestos específicos e usálos para transmitir informações ou para controlar dispositivos. Para isso as interfaces baseados em visão para o reconhecimento de gestos, necessitam de detectar a mão de forma rápida e robusta e de serem capazes de efetuar o reconhecimento de gestos em tempo real. Hoje em dia, os sistemas de reconhecimento de gestos baseados em visão são capazes de trabalhar com soluções específicas, construídos para resolver um determinado problema e configurados para trabalhar de uma forma particular. Este projeto de investigação estudou e implementou soluções, suficientemente genéricas, com o recurso a algoritmos de aprendizagem computacional, permitindo a sua aplicação num conjunto alargado de sistemas de interface homem-máquina, para reconhecimento de gestos em tempo real. A solução proposta, Gesture Learning Module Architecture (GeLMA), permite de forma simples definir um conjunto de comandos que pode ser baseado em gestos estáticos e dinâmicos e que pode ser facilmente integrado e configurado para ser utilizado numa série de aplicações. É um sistema de baixo custo e fácil de treinar e usar, e uma vez que é construído unicamente com bibliotecas de código. As experiências realizadas permitiram mostrar que o sistema atingiu uma precisão de 99,2% em termos de reconhecimento de gestos estáticos e uma precisão média de 93,7% em termos de reconhecimento de gestos dinâmicos. Para validar a solução proposta, foram implementados dois sistemas completos. O primeiro é um sistema em tempo real capaz de ajudar um árbitro a arbitrar um jogo de futebol robótico. A solução proposta combina um sistema de reconhecimento de gestos baseada em visão com a definição de uma linguagem formal, o CommLang Referee, à qual demos a designação de Referee Command Language Interface System (ReCLIS). O sistema identifica os comandos baseados num conjunto de gestos estáticos e dinâmicos executados pelo árbitro, sendo este posteriormente enviado para um interface de computador que transmite a respectiva informação para os robôs. O segundo é um sistema em tempo real capaz de interpretar um subconjunto da Linguagem Gestual Portuguesa. As experiências demonstraram que o sistema foi capaz de reconhecer as vogais em tempo real de forma fiável. Embora a solução implementada apenas tenha sido treinada para reconhecer as cinco vogais, o sistema é facilmente extensível para reconhecer o resto do alfabeto. As experiências também permitiram mostrar que a base dos sistemas de interação baseados em visão pode ser a mesma para todas as aplicações e, deste modo facilitar a sua implementação. A solução proposta tem ainda a vantagem de ser suficientemente genérica e uma base sólida para o desenvolvimento de sistemas baseados em reconhecimento gestual que podem ser facilmente integrados com qualquer aplicação de interface homem-máquina. A linguagem formal de definição da interface pode ser redefinida e o sistema pode ser facilmente configurado e treinado com um conjunto de gestos diferentes de forma a serem integrados na solução final.