997 resultados para Posterior-fossa Surgery
Resumo:
Complete fetal bladder outlet obstruction was first diagnosed in a fetus at 13.5 weeks. After sequential vesico-centesis had shown good renal function, a vesico-amniotic shunt was inserted at 17 weeks with a Rodeck catheter. The procedure was successful and amniotic fluid volume re-accumulated to normal levels. A detailed scan at 20 weeks showed that the distal free end of the catheter was wound round the left fetal thigh. As the fetus grew, there was progressive constriction of the fetal thigh by the catheter. By 29 weeks, Doppler blood flow changes to the left leg were apparent. Fetoscopic surgery was performed at 30 weeks to release the constriction. The catheter was divided successfully, but the divided end of the shunt subsequently retracted into the fetal abdomen, producing urinary ascites, bilateral hydroureter and hydronephrosis. The baby was delivered at 31.5 weeks in good condition. Endoscopic resection of anterior and posterior urethral valves was performed at 6 months of age. At 2 years, the child has normal renal function, growth parameters and developmental milestones. Mild indentation of the left thigh was still apparent, although there was no functional impairment. Copyright (C) 2002 S. Karger AG, Basel.
Resumo:
Background. The incidence of, pulp involvement in patients with excessive wear has not been extensively documented. Methods: Clinical, records of 448 patients with excessive tooth wear were reviewed and 52 cases (11.6 per cent) with near or frank pulp exposures or root canal treatments were found and their numbers and sites were tabulated. Light microscopy of study models was used to determine aetiology at each site of exposure as. attrition, erosion or abrasion, scanning electron microscopy (SEM) was performed on some individual teeth. Results: Forty sites of near exposure and 57 sites of frank exposures or root canal treatments were found, some cases had both types of exposure. The commonest sites exposed by erosion were the palatal surfaces of maxillary, and the incisal surfaces of mandibular anterior teeth. Posterior teeth were not commonly affected. Toothbrush abrasion had exacerbated softie lesions as shown by SEM. Conclusions: Endodontic sequelae were found in 11 per cent of tooth wear patients as late stages of dental erosion. Near and frank exposures of the pulp thus constitute a small but significant, problem for,the Australian dental profession's concern in the of the tooth wear cases.
Resumo:
Posterior leukoencephalopathy syndromes have been reported with hypertension, and immunosuppressive and chemotherapy agents. Cerebral vasospasm on MR angiography (MRA) has been noted in cases due to eclampsia. The authors report a case of Balint syndrome with irreversible posterior leukoencephalopathy on MRI following intrathecal methotrexate and cytarabine. Hypertension was not present. Diffuse, reversible arterial irregularities consistent with vasospasm were present on MRA during the acute illness.
Resumo:
The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.
Resumo:
A transitory increase in blood pressure (BP) is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR) and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10) were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05) increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg), diastolic BP (72 ± 4 vs 67 ± 2 mmHg), HR (67 ± 4 vs 57 ± 2 bpm), respiratory disturbance index (RDI) characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep) and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1) after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01) but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively). These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.
Resumo:
Há vários aspectos controversos no tratamento da paralisia facial traumática. Um destes é a natureza precisa da intervenção cirúrgica a ser usada, uma vez que a decisão de ser realizada tenha sido feita. FORMA DE ESTUDO: Clínico retrospectivo. OBJETIVOS E MÉTODOS: Entre o período de junho de 1984 e junho de 1993, 220 casos de paralisia facial traumática com boa função coclear foram tratados na Universidade de São Paulo pela seguinte técnica cirúrgica: descompressão dos segmentos mastóideo e timpânico através do acesso transmastoídeo e descompressão do gânglio geniculado e dos 50% distais do segmento labiríntico, usando-se o acesso pela fossa média. Apresentamos uma revisão de literatura e a discussão e resultados de nosso trabalho.
Resumo:
Estudo experimental em animais. A mitomicina C vem sendo usada como inibidor de fibroblastos, acarretando, com isso, diminuição do processo cicatricial em feridas cirúrgicas. OBJETIVO: Este trabalho visa avaliar o uso de Mitomicina C para diminuir o processo cicatricial, através de seu uso tópico com reforços posteriores injetáveis. MATERIAL E MÉTODOS: Foi usado um modelo de feridas em dorso de ratos, com retirada circular da pele e cicatrização por segunda intenção. Foram usados 18 ratos, divididos em três grupos: controle; com uso tópico; e com reforço de mitomicina C injetável, mensalmente e por 2 meses. Após 3 meses os animais foram sacrificados e as cicatrizes retiradas cirurgicamente e submetidas a estudo histológico. RESULTADOS: Notou-se sob vários critérios que a cicatrização com o uso tópico é menos intensa, mas ao se usar o reforço injetável os parâmetros voltam a ser comparados ao do grupo controle. DISCUSSÃO: Acreditamos que a administração injetável de mitomicina C nas cicatrizes, pela sua elevada característica tóxica, acarreta destruição tecidual e neoformação cicatricial. CONCLUSÕES: A mitomicina C diminui o processo cicatricial quando usada topicamente, mas acarreta aumento da cicatrização quando nestas feridas são feitos reforços injetáveis.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Laparoscopy is a surgical procedure on which operations in the abdomen are performed through small incisions using several specialized instruments. The laparoscopic surgery success greatly depends on surgeon skills and training. To achieve these technical high-standards, different apprenticeship methods have been developed, many based on in vivo training, an approach that involves high costs and complex setup procedures. This paper explores Virtual Reality (VR) simulation as an alternative for novice surgeons training. Even though several simulators are available on the market claiming successful training experiences, their use is extremely limited due to the economic costs involved. In this work, we present a low-cost laparoscopy simulator able to monitor and assist the trainee’s surgical movements. The developed prototype consists of a set of inexpensive sensors, namely an accelerometer, a gyroscope, a magnetometer and a flex sensor, attached to specific laparoscopic instruments. Our approach allows repeated assisted training of an exercise, without time constraints or additional costs, since no human artificial model is needed. A case study of our simulator applied to instrument manipulation practice (hand-eye coordination) is also presented.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.
Resumo:
Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.