875 resultados para POSTERIOR CHAMBER LENSES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

70 human temporal bones were analyzed with the aid of an otologic microscope. The styloid prominence was found to be extremely variable in shape, location and occurrence. Depending on the degree of development, the prominence establishes important relationships with the sinus tympani, with the fossula of the cochlear fenestra, and with the suprapyramidal recess. Serial sections were used to study the relationship of the styloid process with the facial nerve inside the bony mass of the mastoid portion of the temporal bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vivo study was to evaluate the clinical performance of a posterior composite resin TRH (Caulk Dentisply) in class I restorations in primary molars. A total of 30 children aged 5 to 8 years old with 49 class I dental lesions in primary molars participated in the study. The cavity preparations involved removal of carious lesion only and the enamel margins were beveled. The results showed after 30 months that, 82% (32/39) of Alfa ratings and 18% (7/39) of Bravo ratings. We concluded that the composite resin TP-H could be used in conservative restorations in primary molars, particularly in the late mixed dentition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To investigate pulp chamber penetration of bleaching agents in teeth following restorative procedures. Methodology: Bovine lateral incisors were sectioned 3 mm apical to the cemento-enamel junction and the coronal pulpal tissue was removed. Teeth were divided into six groups (n = 10): G1, G2 and G3 were not submitted to any restorative procedure, while G4, G5 and G6 were submitted to Class V preparations and restored with composite resin. Acetate buffer was placed in the pulp chamber and treatment agents were applied for 60 min at 37°C as follows: G1 and G4, immersion into distilled water; G2 and G5, 10% carbamide peroxide (CP) exposure; G3 and G6, 35% CP bleaching. The buffer solution was removed and transferred to a glass tube where leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined spectrophotometrically at 596 nm. A standard curve made with known amounts of hydrogen peroxide was used to convert the optical density values of the coloured samples into microgram equivalents of hydrogen peroxide. Data were submitted to ANOVA and Tukey's test (5%). Results: Amounts of hydrogen peroxide found in the pulp chamber of G2 and G5 specimens (0.1833 ± 0.2003 μg) were significantly lower (P = 0.001) when compared to G3 and G6 specimens (0.4604 ± 0.3981 μg). Restored teeth held significantly higher (P = 0.001) hydrogen peroxide concentrations in the pulp chamber than intact teeth. Conclusion: Higher concentrations of the bleaching agent produced higher levels of hydrogen peroxide in the pulp chamber, especially in restored teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A left paravertebral mass discovered incidentally on routine examination in a 39-year-old woman is described. Computerized tomography studies revealed a 7 × 6 cm, well circumscribed, noncalcified soft tissue mass with lobular borders abutting the left inferior pulmonary vein and descending aorta. It was not possible to determine the exact anatomic location of the mass based on the imaging studies as both peripheral lung tumors and posterior mediastinal lesions may exhibit the imaging findings described here. At thoracotomy, the mass was seen to be well circumscribed, focally attached to the pleura but without involvement of lung parenchyma, and situated in the left posterior mediastinum. On histological examination, the lesion showed the classical features of myxopapillary ependymoma. Immunohistochemical studies confirmed this impression by demonstrating strong positivity of the tumor cells for S-100 protein, glial fibrillary acidic protein, and CD99 and negative staining with other differentiation markers. A review of the literature with a discussion of the histologic and radiologic differential diagnosis of these lesions is presented. © 2006 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study has been conducted with the objective of investigating the effects of the flame structure in the combustion oscillation conditions into a laboratorial scale cylindrical chamber. The experiments were conducted in a water-jacketed 1-m long by 25-cm internal diameter stainless steel vertical tube. The combustor operated with liquefied petroleum gas (LPG) in both oscillatory and non oscillatory conditions, under the same input conditions. Part of the reactant mixture was excited acoustically, before the burner exit, by a speaker positioned strategically. The burner was aligned with the chamber longitudinal axis and positioned at its bottom. The experiments were conducted for 0.16 g/s of LPG burning in stoichiometric equivalence ratio. To analyze the flame structure the image tomographic reconstruction process were used, and the resultant images were associated to the oscillatory conditions (frequency and amplitude) into the combustion chamber. The main conclusions were: 1) when the flame premixed condition increase, for example 60% of the total air flow rate is premixed with LPG, the region of intense energy released is close to burner exit and strong amplitudes of oscillation (close to 50 mbar) were obtained into the chamber; 2) for long flames, predominantly diffusive flames, just weak amplitudes were detected, in the spite of the speaker exiting the premixed flow; 3) when the energy is released distributed through the combustion chamber, the long flame acts like a baffle. Copyright © 2006 by the American Institute of Aeronautics and Astronautics, Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tractor is one of the machines that more traffics over the soil during the processes involving agricultural production. The interaction tractor/soil is made by the tires which, in most of the cases, are pneumatic. The tire type and the tractor travel speed, interfere directly on the pressure over the soil. One of the techniques employed to evaluate the alterations that tractor traffic causes in the soil is to measure its Cone Index. The aim of this research was to evaluate the same Cone Index alterations caused by an agricultural tractor equipped with both radial tires and bias ply tires, trafficking mobilized soil in four different travel speeds. The experiment was performed in a LATOSSOLO VERMELHO, located 22°51' S, 48°25'W and 770 m of altitude, in Botucatu-SP, Brazil. The soil mobilization was performed with a chisel plow and a disc arrow. The traction was accomplished with a John Deere tractor, model 6600, with 88 kW of power and 6,723 kg. Equipment requiring a force of 25kN was traced by the tractor draw bar. The experimental design was in randomized blocks with 4 × 2 factorial arrangements, with two distinct treatments corresponding to the types of tires (bias and radial) and the four travel speeds, with six replications. There were selected the following speeds: 3.5, 3.9, 5.1 and 5.9 km h-1. To determine the soil resistance, there was utilized MSSU - Mobile Soil Sampling Unit, with which the Cone Index was obtained in layers from 0-100, 100-200, 200-300, 300-400, 400-500 and over 500 mm deep. The Cone Index where evaluated in areas with non contact between tire and soil (ICn) and in the tire footprint track (ICp). There were calculated the Cone Index increments caused by the tractor tire (AIC) and the results showed that as the tractor travel speed increased, there were observed decrements in the medium values of cone index. The radial tire provided smaller values of the Cone Index in the superficial layer of the soil (0 to 100 mm) in relation to the bias ply tire, when the speed was approximately 6 km h-1. The increment in the Cone Index, promoted by the tractor, was more intense in the first 200 mm depth, but it also reached the layer from 200 to 300 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to assess the pulp chamber temperature in different groups of human teeth that had been bleached using hydrogen peroxide gel activated with halogen lamps or hybrid LED/laser appliances. Four groups of ten teeth (maxillary central incisors, mandibular incisors, mandibular canines, and maxillary canines) were used. A digital thermometer with a K-type thermocouple was placed inside pulp chambers that had been filled with thermal paste. A 35% hydrogen peroxide-based red bleaching gel was applied to all teeth and photocured for a total of three minutes and 20 seconds (five activations of 40 seconds each), using light from an LED/laser device and a halogen lamp. The temperatures were gauged every 40 seconds and the data were analyzed by three-way ANOVA, followed by Tukey's test. Regardless of the light source, statistically significant differences were observed between the groups of teeth. The mean temperature values (±SD) were highest for maxillary central incisors and lowest for mandibular canines. The halogen lamp appliance produced more pulp chamber heating than the LED/laser appliance. The increase in irradiation time led to a significant increase in temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the Influence of the coloring agent concentration on the temperature of the gel layer and pulp chamber during dental bleaching with an LED/laser light source. Ten human incisors and a digital thermometer with K-type thermocouples were used. Using a high-speed spherical diamond bur, endodontic access was gained through openings on the lingual faces until pulp chamber was exposed. One end of the thermocouple was placed on the labial surface (immersed in bleaching gel) and the other end in the pulp chamber. The same 10 specimens were used in the 12 groups, according to the type and concentration of bleaching gel. Each bleaching gel was used in four different concentrations: manipulated without coloring, with normal quantity recommended by the manufacturer, with double the recommended amount of coloring, and with triple the recommended amount of coloring. The temperature rise was measured every 30 seconds for three minutes with a K-type thermocouple. The data were analyzed by ANOVA to examine the concentration and type of bleaching gel. This test was followed by Tukey's test, which was performed Independently for the gel at the labial surface and the pulp chamber (a = 5%). For both surfaces, values of p = 0.00 were obtained for all factors and for the Interaction between them. The varying concentrations of coloring agent produced statistically significant differences in terms of temperature increase for both the gel layer and the pulp chamber during activation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study proposal was to evaluate the changes at a masticatory muscle temporalis and masseter, through a eletromyographic, at ponters of the right unilateral bite posterior, verifying the difference at the eletric activity between right and left sides. Twenty female volunteers, with ages between 7 and 8 (x = 7.4). The eletromyographics signals were collected in both sides in all volunteers in rest situations and in an usual isotonic mastication, right, left and bilateral and the maximun isometric constriction, which sinal was used to the eletric activity amplitude normalization. The results signed that the right masseter muscle presents an expressive statistic difference, if compared with the left masseter muscle during the left and right mastication, suggesting a right unilateral mastication. The muscle haven't gotten any expressive variance in this amplitude which remained to a proximate flat noticed in a right and habitual mastication, suggesting a right and one sided mastication during the left mastication occurs a raise of the eletric signal amplitude of the muscle left masseter. The right masseter muscle haven't gained any expressive variance, which remained in a proximate flat observed in an usual and right mastication, suggesting a muscular pattern hyperfunction next to the dental crossing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are situations which the tomographic exam is done on the affected hip or situations where the contralateral hip presents abnormalities that make it impossible to compare. In this study we aimed to evaluate a tomographic index that does not require comparison between the both hips. Twenty two patients with unilateral acetabular fracture dislocation with fracture of posterior wall were studied. We established the relationship between the remaining posterior wall and the femoral head diameter (head/wall index-H/W index). We evaluated 45 two-dimensional computed tomography scan in normal hips and established the H/W index. In 45 normal hips we simulated a posterior wall fracture with involvement of 25% and 30% of the posterior wall and calculated the H/W index. We divided into five groups with five different H/W index (fractured group with non surgical treatment; fractured group; normal group; normal group with simulated fracture of 25% and; 30% of the posterior wall). 2.4 was the lowest limit of confidence interval of the group with 25% of the posterior wall fracture. When we analyzed the confidence interval of the 30% fracture group the upper limit of the confidence interval was 2.7, close to the lower limit of the surgical group that was 2.9. Thus, we suggest the 2.4 the H/W index limit as an auxiliary criteria to indicate whether or not to operate. H/W index is helpful to decide whether or not surgery indication in the fracture dislocation of the posterior wall of the acetabulum. © 2012 Fujiki et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This clinical study assessed the performance of posterior composite resins applied with the Adper™ Single Bond Plus (SB) and Adper ™ Scotchbond SE (SE) adhesive systems and Filtek ™ Supreme Plus composite resin, using modified US Public Health Service criteria. A total of 97 restorations were placed in posterior teeth by two calibrated operators. Application of the materials followed manufacturers' instructions. The restorations were evaluated by two examiners at baseline and after one year. Statistical analyses were conducted using the proportion test at a significance level of 5% (p<0.05). All the restorations evaluated (ie, 100%) received an alpha rating for the criteria of marginal discoloration and marginal integrity at baseline. At one year, for marginal discoloration, 64.6% of SB and 61.2% of SE received an alpha rating. For marginal integrity, 72.9% of SB and 77.6% of SE received an alpha rating. The other restorations received bravo ratings for both criteria. None of the teeth that received the restorative systems presented caries lesions around the restorations. A total of eight teeth presented postoperative sensitivity one week after baseline, five with SB and three with SE; the symptom had disappeared one year later. One year later, composite resin restorations using either adhesive system showed satisfactory clinical performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rehabilitation with oral implants is, without any doubt, a consecrated technique. But often we face situations of high bone atrophy where the conventional installation of dental implants is not possible. The posterior mandible, when severely resorbed, generally requires complex techniques to be rehabilitated with implants, such as the lateralization of the inferior alveolar nerve. As an option for these cases, this paper proposes the use of short implants for the rehabilitation of severely resorbed posterior mandible. Copyright © 2013 by Mutaz B. Habal, MD.