968 resultados para PET module DOI calibration


Relevância:

30.00% 30.00%

Publicador:

Resumo:

panels provides a quick way to count the number of panels (groups) in a dataset and display some basic information about the sizes of the panels. Furthermore, -panels- can be used as a prefix command to other Stata commands to apply them to panel units instead of individual observations. This is useful, for example, if you want to compute frequency distributions or summary statistics for panel characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper shows how an Armington-Krugman-Melitz encompassing module based on Dixon and Rimmer (2012) can be calibrated, and clarifies the choice of initial levels for two kinds of number of firms, or parameter values for two kinds of fixed costs, that enter a Melitz-type specification can be set freely to any preferred value, just as the cases we derive quantities from given value data assuming some of the initial prices to be unity. In consequence, only one kind of additional information, which is on the shape parameter related to productivity, just is required in order to incorporate Melitz-type monopolistic competition and heterogeneous firms into a standard applied general equilibrium model. To be a Krugman-type, nothing is needed. This enables model builders in applied economics to fully enjoy the featured properties of the theoretical models invented by Krugman (1980) and Melitz (2003) in practical policy simulations at low cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gamma detectors based on monolithic scintillator blocks coupled to APDs matrices have proved to be a good alternative to pixelated ones for PET scanners. They provide comparable spatial resolution, improve the sensitivity and make easier the mechanical design of the system. In this study we evaluate by means of Geant4-based simulations the possibility of replacing the APDs by SiPMs. Several commercial matrices of light sensors coupled to LYSO:Ce monolithic blocks have been simulated and compared. Regarding the spatial resolution and linearity of the detector, SiPMs with high photo detection efficiency could become an advantageous replacement for the APDs

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have analyzed the performance of a PET demonstrator formed by two sectors of four monolithic detector blocks placed face-to-face. Both front-end and read-out electronics have been evaluated by means of coincidence measurements using a rotating 22Na source placed at the center of the sectors in order to emulate the behavior of a complete full ring. A continuous training method based on neural network (NN) algorithms has been carried out to determine the entrance points over the surface of the detectors. Reconstructed images from 1 MBq 22Na point source and 22Na Derenzo phantom have been obtained using both filtered back projection (FBP) analytic methods and the OSEM 3D iterative algorithm available in the STIR software package [1]. Preliminary data on image reconstruction from a 22Na point source with Ø = 0.25 mm show spatial resolutions from 1.7 to 2.1 mm FWHM in the transverse plane. The results confirm the viability of this design for the development of a full-ring brain PET scanner compatible with magnetic resonance imaging for human studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a new projector model specifically tailored for fast list-mode tomographic reconstructions in Positron emission tomography (PET) scanners with parallel planar detectors. The model provides an accurate estimation of the probability distribution of coincidence events defined by pairs of scintillating crystals. This distribution is parameterized with 2D elliptical Gaussian functions defined in planes perpendicular to the main axis of the tube of response (TOR). The parameters of these Gaussian functions have been obtained by fitting Monte Carlo simulations that include positron range, acolinearity of gamma rays, as well as detector attenuation and scatter effects. The proposed model has been applied efficiently to list-mode reconstruction algorithms. Evaluation with Monte Carlo simulations over a rotating high resolution PET scanner indicates that this model allows to obtain better recovery to noise ratio in OSEM (ordered-subsets, expectation-maximization) reconstruction, if compared to list-mode reconstruction with symmetric circular Gaussian TOR model, and histogram-based OSEM with precalculated system matrix using Monte Carlo simulated models and symmetries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Models based on degradation are powerful and useful tools to evaluate the reliability of those devices in which failure happens because of degradation in the performance parameters. This paper presents a procedure for assessing the reliability of concentrator photovoltaic (CPV) modules operating outdoors in real-time conditions. With this model, the main reliability functions are predicted. This model has been applied to a real case with a module composed of GaAs single-junction solar cells and total internal reflection (TIR) optics