904 resultados para PASSIVE FIT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study deals with indoor positioning using GSM radio, which has the distinct advantage of wide coverage over other wireless technologies. In particular, we focus on passive localization systems that are able to achieve high localization accuracy without any prior knowledge of the indoor environment or the tracking device radio settings. In order to overcome these challenges, newly proposed localization algorithms based on the exploitation of the received signal strength (RSS) are proposed. We explore the effects of non-line-of-sight communication links, opening and closing of doors, and human mobility on RSS measurements and localization accuracy. We have implemented the proposed algorithms on top of software defined radio systems and carried out detailed empirical indoor experiments. The performance results show that the proposed solutions are accurate with average localization errors between 2.4 and 3.2 meters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. WATSU (WaterShiatsu) is a complementary therapeutic treatment method comprising passive stretches and massage techniques administered in 35°C warm water. Pregnant women claim safe methods to reduce pain, stress, and fatigue. Therefore, we conducted a pilot study evaluating the effects of WATSU on pregnancy-related complaints in third trimester pregnant women. Methods. Nine healthy pregnant women at gestational week ≥34 were included in an intervention group (receiving WATSU) and compared to eight women in a passive control group (receiving no treatment). WATSU was performed on days 1 and 4 of the study, accompanied by ultrasound examinations. Outcomes include physiological and psychometric as well as qualitative data. Participants in the control group completed questionnaires only. Results. WATSU was found to significantly lower participants’ levels of stress and pain and to improve their mental health-related quality of life and mood. In comparison to the passive control group, participants in the intervention group reported reduction in perceived stress from day 1 to day 8 (p = 0.036, Cohen’s f = 0.57). Qualitative data indicate that WATSU was appreciated as enjoyable and deeply relaxing. No negative side effects were reported. Conclusion. Our findings support the notion that WATSU yields therapeutic benefits for pregnant women and warrant further research. This study has been registered at ClinicalTrials.gov: NCT01708018.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic stimulation of the cochlea leads to a travelling wave in the cochlear fluids and on the basilar membrane (BM). It has long been suspected that this travelling wave leads to a steady streaming flow in the cochlea. Theoretical investigations suggested that the steady streaming might be of physiological relevance. Here, we present a quantitative study of the steady streaming in a computational model of a passive cochlea. The structure of the streaming flow is illustrated and the sources of streaming are closely investigated. We describe a source of streaming which has not been considered in the cochlea by previous authors. This source is also related to a steady axial displacement of the BM which leads to a local stretching of this compliant structure. We present theoretical predictions for the streaming intensity which account for these new phenomena. It is shown that these predictions compare well with our numerical results and that there may be steady streaming velocities of the order of millimetres per second. Our results indicate that steady streaming should be more relevant to low-frequency hearing because the strength of the streaming flow rapidly decreases for higher frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various assays have been used as an aid to diagnose failure of passive transfer (FPT) of immunoglobulins in neonatal foals, but often lack sensitivity as screening tests, or are time consuming to perform and impractical as confirmatory tests. The aim of the present study was to evaluate whether measurement of serum total globulins (TG; i.e. total protein minus albumin) can be used to estimate the electrophoretic gamma globulin (EGG) fraction in hospitalised neonatal foals with suspected FPT. Sample data from 56 foals were evaluated retrospectively. The coefficient of rank correlation was 0.84. The area under the curve of ROC analysis was 0.887, 0.922 and 0.930 for EGG concentrations <2 g/L, < 4 g/L and <8 g/L, respectively. Cut-offs for TG achieved ≥90% sensitivity for detecting EGG <2 g/L, < 4 g/L and <8 g/L, with negative predictive values of >97% and >94%, using prevalence of 15% and 30%, respectively. These results suggest that measurement of TG can be used as a guide to predicting EGG, provided that appropriate cut-off values are selected, and this technique could be a useful initial screening test for FPT in foals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Knee pain is associated with radiographic knee osteoarthritis, but the relationships between physical examination, pain and radiographic features are unclear. OBJECTIVE To examine whether deficits in knee extension or flexion were associated with radiographic severity and pain during clinical examination in persons with knee pain or radiographic features of osteoarthritis. DESIGN Cross-sectional data of the Somerset and Avon Survey of Health (SASH) cohort study. METHODS Participants with knee pain or radiographic features of osteoarthritis were included. We assessed the range of passive knee flexion and extension, pain on movement and Kellgren and Lawrence (K/L) grades. Odds ratios were calculated for the association between range of motion and pain as well as radiographic severity. RESULTS/FINDINGS Of 1117 participants with a clinical assessment, 805 participants and 1530 knees had complete data and were used for this analysis. Pain and radiographic changes were associated with limited range of motion. In knees with pain on passive movement, extension and flexion were reduced per one grade of K/L by -1.4° (95% CI -2.2 to -0.5) and -1.6° (95% CI -2.8 to -0.4), while in knees without pain the reduction was -0.3° (95% CI -0.6 to -0.1) (extension) and -1.1° (-1.8 to -0.3) (flexion). The interaction of pain with K/L was significant (p = 0.021) for extension but not for flexion (p = 0.333). CONCLUSIONS Pain during passive movement, which may be an indicator of reversible soft-tissue changes, e.g., reversible through physical therapy, is independently associated with reduced flexion and extension of the knee.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The cost-effectiveness of cast nonprecious frameworks has increased their prevalence in cemented implant crowns. The purpose of this study was to assess the effect of the design and height of the retentive component of a standard titanium implant abutment on the fit, possible horizontal rotation and retention forces of cast nonprecious alloy crowns prior to cementation. MATERIALS AND METHODS Two abutment designs were examined: Type A with a 6° taper and 8 antirotation planes (Straumann Tissue-Level RN) and Type B with a 7.5° taper and 1 antirotation plane (SICace implant). Both types were analyzed using 60 crowns: 20 with a full abutment height (6 mm), 20 with a medium abutment height (4 mm), and 20 with a minimal (2.5 mm) abutment height. The marginal and internal fit and the degree of possible rotation were evaluated by using polyvinylsiloxane impressions under a light microscope (magnification of ×50). To measure the retention force, a custom force-measuring device was employed. STATISTICAL ANALYSIS one-sided Wilcoxon rank-sum tests with Bonferroni-Holm corrections, Fisher's exact tests, and Spearman's rank correlation coefficient. RESULTS Type A exhibited increased marginal gaps (primary end-point: 55 ± 20 μm vs. 138 ± 59 μm, P < 0.001) but less rotation (P < 0.001) than Type B. The internal fit was also better for Type A than for Type B (P < 0.001). The retention force of Type A (2.49 ± 3.2 N) was higher (P = 0.019) than that of Type B (1.27 ± 0.84 N). Reduction in abutment height did not affect the variables observed. CONCLUSION Less-tapered abutments with more antirotation planes provide an increase in the retention force, which confines the horizontal rotation but widens the marginal gaps of the crowns. Thus, casting of nonprecious crowns with Type A abutments may result in clinically unfavorable marginal gaps.