832 resultados para Otimização de rotas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2001, it was estimated that pesticide used worldwide exceeded 2.27 billion kilograms, over 35%, of which, were herbicides. Brazil is considered one of the leaders in the production of sugarcane and mainly ethanol as fuel. The monoculture of sugarcane requires the usage of a range of pesticides, among these, the herbicides diuron and tebuthiuron. The degradation products most studied (DCA and DCPU) are diuron's, especially for toxicological characteristics of this herbicide that is identified as carcinogen and suspected to be endocrine disruptor in mammals. After optimization of the chromatographic separation using HPLC-UV, the analytical curve was constructed in solvent and subsequently in the matrix (surface water). The extraction method contains the usage of SPE (solid phase extraction) (Strata-X, 200 mg/6 mL), applicating 1L of sample and elution with 5 mL of acetonitrile / methanol (50:50, v/v). Analysis by HPLC/UV was performed in gradient mode, acetonitrile/water (70/30-74/26 by 1 min, 74/26 - 78/22 till 3.2 min, returning to initial conditions and remaining this way until 10 min), 018 column (Phenomenex, 4.6 mm diameter, 250 mm long and 5pm particle size) and detection at 254 nm. Tests F and t were performed to verify the presence of the matrix effect. There was matrix effect to all analytes, ranging from -33% (DCA) and 38% (tebuthiuron). Thereby the method was optimized and validated for analysis of diuron, tebuthiuron, and DCPU DCA in surface water using HPLC/UV. The data obtained show that in order to assure the analytical reliability desired the use of the analytical curves in the matrix for the quantification of these analytes in water is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O extraordinário desenvolvimento da produção avícola, particularmente no setor de frango de corte, tornou o Brasil um importante produtor e exportador de carne de frango. Esse fato aliado a proibição da utilização de cama de frango como ração para ruminantes pela Instrução Normativa nº15 de 17 de julho de 2001, fez com que este resíduo se tornasse um problema ecológico e de saúde pública de alta relevância, tanto pelo volume de resíduos gerado, quanto pela composição do mesmo, que pode conter diversos fármacos utilizados neste tipo de manejo, além de uréia, que após a oxidação natural no ambiente, resulta em nitrato que tem alto poder de contaminação de mananciais hídricos, principalmente subterrâneos. Dentre as substâncias que podem estar presentes na cama de frango, estão os antimicrobianos, utilizados como promotores de crescimento das aves. No Brasil, são pouquíssimos os trabalhos dedicados a investigar a ocorrência e o impacto ambiental de antimicrobianos. Desta maneira, este trabalho teve como objetivo otimizar e validar método para análise de três fluoroquinolonas (ciprofloxacina, norfloxacina e enrofloxacina) em cama de frango. O método estudado baseou-se em trabalhos da literatura em que moléculas similares foram analisadas em diversas matrizes, compreendendo a extração em ultrassom com acetonitrila acidificada com ácido acético (3% v/v) e análise por CLAE-FLU, modo isocrático com a fase móvel composta por 0,02 M H3PO4:ACN (83:17, v/v). Foram avaliados os parâmetros cromatográficos quanto à resolução, eficiência, linearidade e limites de detecção e quantif-1 para os três analitos. O tempo de análise do método cromatográfico otimizado é de 7,5 minutos. Avaliou-se também o efeito de matriz que foi significativo para norfloxacina e ciprofloxacina, correspondendo a 16 e 20%, respectivamente. Para a enrofloxacina a amostra...