921 resultados para Objective Image Quality
Resumo:
In this work, a Monte Carlo code was used to investigate the performance of different x-ray spectra in digital mammography, through a figure of merit (FOM), defined as FOM = CNR2/(D) over bar (g), with CNR being the contrast-to-noise ratio in image and (D) over bar (g) being the average glandular dose. The FOM was studied for breasts with different thicknesses t (2 cm <= t <= 8 cm) and glandular contents (25%, 50% and 75% glandularity). The anode/filter combinations evaluated were those traditionally employed in mammography (Mo/Mo, Mo/Rh, Rh/Rh), and a W anode combined with Al or K-edge filters (Zr, Mo, Rh, Pd, Ag, Cd, Sn), for tube potentials between 22 and 34 kVp. Results show that the W anode combined with K-edge filters provides higher values of FOM for all breast thicknesses investigated. Nevertheless, the most suitable filter and tube potential depend on the breast thickness, and for t >= 6 cm, they also depend on breast glandularity. Particularly for thick and dense breasts, a W anode combined with K-edge filters can greatly improve the digital technique, with the values of FOM up to 200% greater than that obtained with the anode/filter combinations and tube potentials traditionally employed in mammography. For breasts with t < 4 cm, a general good performance was obtained with the W anode combined with 60 mu m of the Mo filter at 24-25 kVp, while 60 mu m of the Pd filter provided a general good performance at 24-26 kVp for t = 4 cm, and at 28-30 and 29-31 kVp for t = 6 and 8 cm, respectively.
Resumo:
Objectives: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. Material and Methods: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. Results: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). Conclusions: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.
Resumo:
Context. The ESO public survey VISTA variables in the Via Lactea (VVV) started in 2010. VVV targets 562 sq. deg in the Galactic bulge and an adjacent plane region and is expected to run for about five years. Aims. We describe the progress of the survey observations in the first observing season, the observing strategy, and quality of the data obtained. Methods. The observations are carried out on the 4-m VISTA telescope in the ZYJHK(s) filters. In addition to the multi-band imaging the variability monitoring campaign in the K-s filter has started. Data reduction is carried out using the pipeline at the Cambridge Astronomical Survey Unit. The photometric and astrometric calibration is performed via the numerous 2MASS sources observed in each pointing. Results. The first data release contains the aperture photometry and astrometric catalogues for 348 individual pointings in the ZYJHK(s) filters taken in the 2010 observing season. The typical image quality is similar to 0 ''.9-1 ''.0. The stringent photometric and image quality requirements of the survey are satisfied in 100% of the JHK(s) images in the disk area and 90% of the JHK(s) images in the bulge area. The completeness in the Z and Y images is 84% in the disk, and 40% in the bulge. The first season catalogues contain 1.28 x 10(8) stellar sources in the bulge and 1.68 x 10(8) in the disk area detected in at least one of the photometric bands. The combined, multi-band catalogues contain more than 1.63 x 10(8) stellar sources. About 10% of these are double detections because of overlapping adjacent pointings. These overlapping multiple detections are used to characterise the quality of the data. The images in the JHK(s) bands extend typically similar to 4 mag deeper than 2MASS. The magnitude limit and photometric quality depend strongly on crowding in the inner Galactic regions. The astrometry for K-s = 15-18 mag has rms similar to 35-175 mas. Conclusions. The VVV Survey data products offer a unique dataset to map the stellar populations in the Galactic bulge and the adjacent plane and provide an exciting new tool for the study of the structure, content, and star-formation history of our Galaxy, as well as for investigations of the newly discovered star clusters, star-forming regions in the disk, high proper motion stars, asteroids, planetary nebulae, and other interesting objects.
Resumo:
This study aimed to evaluate the sleep quality and impact of thoracentesis on sleep in patients with a large pleural effusion. Patients with large unilateral pleural effusion were evaluated by the Pittsburgh Sleep Quality Index (PSQI) questionnaire and dyspnea Borg scale. Full polysomnography (PSG) was performed on the night before and 36 h after thoracentesis. We studied 19 patients, 11 males and 8 females, age 55 +/- 18 years and body mass index of 26 +/- 5 kg/m(2). The baseline sleep quality was poor (PSQI = 9.1 +/- 3.5). Thoracentesis removed 1.624 +/- 796 mL of pleural fluid and resulted in a significant decrease in dyspnea Borg scale (2.3 +/- 2.1 vs. 0.8 +/- 0.9, p < 0.001). The PSG before and after thoracentesis showed no significant change in apnea-hypopnea index and sleep time with oxygen saturation < 90%. There was a significant improvement in sleep efficiency (76% vs. 81%, p = 0.006), decrease percent sleep stage 1 (16% vs. 14%, p = 0.002), and a trend improvement in total sleep time (344 +/- 92 vs. 380 +/- 69 min, p = 0.056) and percentage of rapid eye movement sleep (15% vs. 20%, p = 0.053). No significant changes occurred in six patients that performed two consecutive PSG before thoracentesis. The improvement in sleep quality was not associated with the volume of pleural fluid withdrawn or changes in dyspnea. Patients with large pleural effusion have poor subjective and objective sleep quality that improves after thoracentesis.
Resumo:
The main problem connected to cone beam computed tomography (CT) systems for industrial applications employing 450 kV X-ray tubes is the high amount of scattered radiation which is added to the primary radiation (signal). This stray radiation leads to a significant degradation of the image quality. A better understanding of the scattering and methods to reduce its effects are therefore necessary to improve the image quality. Several studies have been carried out in the medical field at lower energies, whereas studies in industrial CT, especially for energies up to 450 kV, are lacking. Moreover, the studies reported in literature do not consider the scattered radiation generated by the CT system structure and the walls of the X-ray room (environmental scatter). In order to investigate the scattering on CT projections a GEANT4-based Monte Carlo (MC) model was developed. The model, which has been validated against experimental data, has enabled the calculation of the scattering including the environmental scatter, the optimization of an anti-scatter grid suitable for the CT system, and the optimization of the hardware components of the CT system. The investigation of multiple scattering in the CT projections showed that its contribution is 2.3 times the one of primary radiation for certain objects. The results of the environmental scatter showed that it is the major component of the scattering for aluminum box objects of front size 70 x 70 mm2 and that it strongly depends on the thickness of the object and therefore on the projection. For that reason, its correction is one of the key factors for achieving high quality images. The anti-scatter grid optimized by means of the developed MC model was found to reduce the scatter-toprimary ratio in the reconstructed images by 20 %. The object and environmental scatter calculated by means of the simulation were used to improve the scatter correction algorithm which could be patented by Empa. The results showed that the cupping effect in the corrected image is strongly reduced. The developed CT simulation is a powerful tool to optimize the design of the CT system and to evaluate the contribution of the scattered radiation to the image. Besides, it has offered a basis for a new scatter correction approach by which it has been possible to achieve images with the same spatial resolution as state-of-the-art well collimated fan-beam CT with a gain in the reconstruction time of a factor 10. This result has a high economic impact in non-destructive testing and evaluation, and reverse engineering.
Resumo:
Biological processes are very complex mechanisms, most of them being accompanied by or manifested as signals that reflect their essential characteristics and qualities. The development of diagnostic techniques based on signal and image acquisition from the human body is commonly retained as one of the propelling factors in the advancements in medicine and biosciences recorded in the recent past. It is a fact that the instruments used for biological signal and image recording, like any other acquisition system, are affected by non-idealities which, by different degrees, negatively impact on the accuracy of the recording. This work discusses how it is possible to attenuate, and ideally to remove, these effects, with a particular attention toward ultrasound imaging and extracellular recordings. Original algorithms developed during the Ph.D. research activity will be examined and compared to ones in literature tackling the same problems; results will be drawn on the base of comparative tests on both synthetic and in-vivo acquisitions, evaluating standard metrics in the respective field of application. All the developed algorithms share an adaptive approach to signal analysis, meaning that their behavior is not dependent only on designer choices, but driven by input signal characteristics too. Performance comparisons following the state of the art concerning image quality assessment, contrast gain estimation and resolution gain quantification as well as visual inspection highlighted very good results featured by the proposed ultrasound image deconvolution and restoring algorithms: axial resolution up to 5 times better than algorithms in literature are possible. Concerning extracellular recordings, the results of the proposed denoising technique compared to other signal processing algorithms pointed out an improvement of the state of the art of almost 4 dB.
Resumo:
To date the hospital radiological workflow is completing a transition from analog to digital technology. Since the X-rays digital detection technologies have become mature, hospitals are trading on the natural devices turnover to replace the conventional screen film devices with digital ones. The transition process is complex and involves not just the equipment replacement but also new arrangements for image transmission, display (and reporting) and storage. This work is focused on 2D digital detector’s characterization with a concern to specific clinical application; the systems features linked to the image quality are analyzed to assess the clinical performances, the conversion efficiency, and the minimum dose necessary to get an acceptable image. The first section overviews the digital detector technologies focusing on the recent and promising technological developments. The second section contains a description of the characterization methods considered in this thesis categorized in physical, psychophysical and clinical; theory, models and procedures are described as well. The third section contains a set of characterizations performed on new equipments that appears to be some of the most advanced technologies available to date. The fourth section deals with some procedures and schemes employed for quality assurance programs.
Resumo:
This thesis is focused on the study of techniques that allow to have reliable transmission of multimedia content in streaming and broadcasting applications, targeting in particular video content. The design of efficient error-control mechanisms, to enhance video transmission systems reliability, has been addressed considering cross-layer and multi-layer/multi-dimensional channel coding techniques to cope with bit errors as well as packet erasures. Mechanisms for unequal time interleaving have been designed as a viable solution to reduce the impact of errors and erasures by acting on the time diversity of the data flow, thus enhancing robustness against correlated channel impairments. In order to account for the nature of the factors which affect the physical layer channel in the evaluation of FEC schemes performances, an ad-hoc error-event modeling has been devised. In addition, the impact of error correction/protection techniques on the quality perceived by the consumers of video services applications and techniques for objective/subjective quality evaluation have been studied. The applicability and value of the proposed techniques have been tested by considering practical constraints and requirements of real system implementations.
Resumo:
The diameters of traditional dish concentrators can reach several tens of meters, the construction of monolithic mirrors being difficult at these scales: cheap flat reflecting facets mounted on a common frame generally reproduce a paraboloidal surface. When a standard imaging mirror is coupled with a PV dense array, problems arise since the solar image focused is intrinsically circular. Moreover, the corresponding irradiance distribution is bell-shaped in contrast with the requirement of having all the cells under the same illumination. Mismatch losses occur when interconnected cells experience different conditions, in particular in series connections. In this PhD Thesis, we aim at solving these issues by a multidisciplinary approach, exploiting optical concepts and applications developed specifically for astronomical use, where the improvement of the image quality is a very important issue. The strategy we propose is to boost the spot uniformity acting uniquely on the primary reflector and avoiding the big mirrors segmentation into numerous smaller elements that need to be accurately mounted and aligned. In the proposed method, the shape of the mirrors is analytically described by the Zernike polynomials and its optimization is numerically obtained to give a non-imaging optics able to produce a quasi-square spot, spatially uniform and with prescribed concentration level. The freeform primary optics leads to a substantial gain in efficiency without secondary optics. Simple electrical schemes for the receiver are also required. The concept has been investigated theoretically modeling an example of CPV dense array application, including the development of non-optical aspects as the design of the detector and of the supporting mechanics. For the method proposed and the specific CPV system described, a patent application has been filed in Italy with the number TO2014A000016. The patent has been developed thanks to the collaboration between the University of Bologna and INAF (National Institute for Astrophysics).
Resumo:
Der Einsatz von den Polyelektrolytkomplexen von DNA / RNA mit Polykationen oder Lipiden in der Gen-Therapie ist für Wissenschaftler von besonderem Interesse, da sie als Träger für den Transport von genetischem Material in lebende Zellen fungieren können. Interessant ist auch die Komplexbildung aus Gadolinium und Polykation, hier können die stabil gebildeten Aggregate als Kontrastmittel zur Anwendung in der Magnetresonanztomographie eingeführt werden. Ziel der vorliegenden Arbeit war es, strukturdefinierte, positiv geladene, polyvalente sperminanaloge Polymere zu synthetisieren. Durch die polyelektrolytische Natur erlauben solche Polymere die Komplexierung von mehr Gadolinium-Polyoxometalaten und wären deshalb sehr gut als Kontrastmittel geeignet. Aufbauend auf den Vorarbeiten, wurde insbesondere die Komplexbildung von kationischem Polymer mit der Green Fluorescent Protein DNA in physiologischem Salzgehalt untersucht. Die Beschreibung der Synthese im Rahmen dieser Arbeit zeigt, dass es mit dem entwickelten Syntheseprinzip, also unter Einsatz von orthogonaler Schutzgruppenchemie und funktionaler Transformation gelungen ist, durch einfache nukleophile Substitution die Kopplung der Elementareinheiten zu komplexeren, auch ionischen Tensiden durchzuführen. Die Komplexierung von Gadolinium-Polyoxometalat mit kationisch geladenem Polymer in reinem Wasser und in physiologischem Salzgehalt hat gezeigt, dass bei einem Ladungsverhältnis von ungefähr 2:1 stabile sphärische Komplexe gebildet werden. HeLa-Zellen zeigen keine hohe Empfindlichkeit gegenüber Polykation-POM-Komplexen, da deren toxische Wirkung nur einen Anteil toter Zellen von maximal 24 % zur Folge hatte. Die Bildqualität einer MRT-Aufnahme der gebildeten Polykation-POM-Komplexe wurde im Vergleich zu den reinen Gadolinium-Polyoxometalat-Lösungen erheblich verbessert. Die Komplexierung von DNA mit dem im Überschuss vorliegenden kationisch geladenen Polymer wurde mittels Rasterkraftmikroskopie, statischer sowie dynamischer Lichtstreuung untersucht. Die Molmasse und Größe der Polykation-DNA-Komplexe geben eindeutige Hinweise darauf, dass sich in physiologischer Salzlösung Multi-Ketten-Komplexe bilden. Neben der Untersuchung der Polymer-Komplexe wurde eine Reihe neuartiger multivalenter kationischer Tenside hergestellt, wobei ihre Eigenschaften beispielsweise mit Tensid B (C12N4), Tensid C (EG8N4) und Tensid F (EG8C12N4) in wässriger Lösung bei verschiedener Salzkonzentration im Vordergrund stehen.
Resumo:
In den westlichen Industrieländern ist das Mammakarzinom der häufigste bösartige Tumor der Frau. Sein weltweiter Anteil an allen Krebserkrankungen der Frau beläuft sich auf etwa 21 %. Inzwischen ist jede neunte Frau bedroht, während ihres Lebens an Brustkrebs zu erkranken. Die alterstandardisierte Mortalitätrate liegt derzeit bei knapp 27 %.rnrnDas Mammakarzinom hat eine relative geringe Wachstumsrate. Die Existenz eines diagnostischen Verfahrens, mit dem alle Mammakarzinome unter 10 mm Durchmesser erkannt und entfernt werden, würden den Tod durch Brustkrebs praktisch beseitigen. Denn die 20-Jahres-Überlebungsrate bei Erkrankung durch initiale Karzinome der Größe 5 bis 10 mm liegt mit über 95 % sehr hoch.rnrnMit der Kontrastmittel gestützten Bildgebung durch die MRT steht eine relativ junge Untersuchungsmethode zur Verfügung, die sensitiv genug zur Erkennung von Karzinomen ab einer Größe von 3 mm Durchmesser ist. Die diagnostische Methodik ist jedoch komplex, fehleranfällig, erfordert eine lange Einarbeitungszeit und somit viel Erfahrung des Radiologen.rnrnEine Computer unterstützte Diagnosesoftware kann die Qualität einer solch komplexen Diagnose erhöhen oder zumindest den Prozess beschleunigen. Das Ziel dieser Arbeit ist die Entwicklung einer vollautomatischen Diagnose Software, die als Zweitmeinungssystem eingesetzt werden kann. Meines Wissens existiert eine solche komplette Software bis heute nicht.rnrnDie Software führt eine Kette von verschiedenen Bildverarbeitungsschritten aus, die dem Vorgehen des Radiologen nachgeahmt wurden. Als Ergebnis wird eine selbstständige Diagnose für jede gefundene Läsion erstellt: Zuerst eleminiert eine 3d Bildregistrierung Bewegungsartefakte als Vorverarbeitungsschritt, um die Bildqualität der nachfolgenden Verarbeitungsschritte zu verbessern. Jedes kontrastanreichernde Objekt wird durch eine regelbasierte Segmentierung mit adaptiven Schwellwerten detektiert. Durch die Berechnung kinetischer und morphologischer Merkmale werden die Eigenschaften der Kontrastmittelaufnahme, Form-, Rand- und Textureeigenschaften für jedes Objekt beschrieben. Abschließend werden basierend auf den erhobenen Featurevektor durch zwei trainierte neuronale Netze jedes Objekt in zusätzliche Funde oder in gut- oder bösartige Läsionen klassifiziert.rnrnDie Leistungsfähigkeit der Software wurde auf Bilddaten von 101 weiblichen Patientinnen getested, die 141 histologisch gesicherte Läsionen enthielten. Die Vorhersage der Gesundheit dieser Läsionen ergab eine Sensitivität von 88 % bei einer Spezifität von 72 %. Diese Werte sind den in der Literatur bekannten Vorhersagen von Expertenradiologen ähnlich. Die Vorhersagen enthielten durchschnittlich 2,5 zusätzliche bösartige Funde pro Patientin, die sich als falsch klassifizierte Artefakte herausstellten.rn
Resumo:
Die vorliegende Dissertation zeigt eine erfolgreiche Verknüpfung der Triplett-Triplett-Annihilations-Aufkonversion (TTA-UC) mit möglichen biologischen Anwendungen. Die Grundlage für solche Anwendungen ist ein Transfer der TTA-UC aus seinem üblicherweise verwendeten organischen Medium in eine wässrige Umgebung. Um diesen Transfer zu realisieren, wurden, unter Anwendung der Technik des Miniemulsionsprozesses, in Wasser dispergierte Nanokapseln herstellt. Der Kern dieser Nanokapseln besteht aus einem flüssigen hydrophoben Medium (meist Hexadekan oder Phenylheptadekan), in dem die zur TTA-UC notwendigen Farbstoffe gelöst sind. Dieser flüssige Kern ist vollständig von einer festen Polymerhülle umschlossen und somit isoliert von seiner wässrigen Umgebung. Es wurden insgesamt drei Generationen solcher Nanokapseln hergestellt, die sich hauptsächlich im Herstellungsprozess, aber auch beim Material von Kern und Hülle unterscheiden. Mittels dieser Variationen konnten die Nanokapseln in Bezug auf Effizienz, Anregungswellenlänge und Sauerstoffempfindlichkeit optimiert werden. Bei der ersten Generation wurde die radikalische Miniemulsionspolymerisation zur Kapselbildung verwendet. Die zweite Generation wurde durch die Kombination des Lösungsmittelverdampfungsprozesses mit dem Miniemulsionsprozess entwickelt und liefert somit eine alternative Möglichkeit der Kapselbildung unter milden Reaktionsbedingungen, was eine uneingeschränkte Auswahl der UC-Farbstoffpaare ermöglicht. Durch den Einsatz unterschiedlicher Sensitizer konnte die Anregungswellenlänge der TTA-UC in den roten und in den nahen Infrarot-Bereich des sichtbaren Spektrums verschoben werden. Diese Verschiebung ist im biologischen Anwendungsbereich von enormer Bedeutung, da dort eine Überlappung mit dem natürlichen optischen Fenster von menschlicher Haut und Gewebe stattfindet. Dies reduziert die Streuung der Anregungsquelle im zu untersuchende Medium und ermöglicht hohe Eindringtiefen. Mit den Kapseln der zweiten Generation wurde zum ersten Mal TTA-UC in lebenden HeLa-Zellen (Krebszellen) und MSCs (Mesenchymale Stammzellen) nachgewiesen. Die verzögerte Fluoreszenz aus den Zellen wurde mit biologischen Standardverfahren, sowohl mit der Durchflusszytometrie (FACS) als auch am cLSM nachgewiesen. Besondere Vorteile gegenüber direkter Fluoreszenz konnten bei der Bildgebung von Zellen erreicht werden. Die relativ energiearme Anregungswellenlänge und die dazu anti-Stokes verschobene, detektierte verzögerte UC-Fluoreszenz lieferte eine bessere Bildqualität und eine sehr geringe Phototoxizität der Zellen. Die Kapseln der dritten Generation zeichnen sich durch ihre anorganische, tetraedrisch verknüpfte SiO2-Hülle aus und wurden mittels einer Grenzflächenreaktion (Sol-Gel-Prozess) in Miniemulsion hergestellt. Diese Kapseln weisen im Vergleich zu den Polymernanokapseln eine bessere UC-Effizienz auf und sind zusätzlich stabiler und robuster.
Resumo:
Lo scopo di questo lavoro è la caratterizzazione fisica del flat panel PaxScan4030CB Varian, rivelatore di raggi X impiegato in un ampio spettro di applicazioni cliniche, dalla radiografia generale alla radiologia interventistica. Nell’ambito clinico, al fine di una diagnosi accurata, è necessario avere una buona qualità dell’immagine radiologica mantenendo il più basso livello di dose rilasciata al paziente. Elemento fondamentale per ottenere questo risultato è la scelta del rivelatore di radiazione X, che deve garantire prestazioni fisiche (contrasto, risoluzione spaziale e rumore) adeguati alla specifica procedura. Le metriche oggettive che misurano queste caratteristiche sono SNR (Signal-to-Noise Ratio), MTF (Modulation Transfer Function) ed NPS (Noise Power Spectrum), che insieme contribuiscono alla misura della DQE (Detective Quantum Efficiency), il parametro più completo e adatto a stabilire le performance di un sistema di imaging. L’oggettività di queste misure consente anche di mettere a confronto tra loro diversi sistemi di rivelazione. La misura di questi parametri deve essere effettuata seguendo precisi protocolli di fisica medica, che sono stati applicati al rivelatore PaxScan4030CB presente nel laboratorio del Centro di Coordinamento di Fisica Medica, Policlinico S.Orsola. I risultati ottenuti, conformi a quelli dichiarati dal costruttore, sono stati confrontati con successo con alcuni lavori presenti in letteratura e costituiscono la base necessaria per la verifica di procedure di ottimizzazione dell’immagine radiologica attraverso interventi sul processo di emissione dei raggi X e sul trattamento informatico dell’immagine (Digital Subtraction Angiography).
Resumo:
To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.
Resumo:
Susceptibility-weighted MR imaging (SWI) is usually obtained without administration of intravenous gadolinium (Gd). However, it is occasionally necessary to perform SWI after Gd is injected. The effects of Gd on SWI have not been systematically examined. The aim of this prospective study was to investigate whether performing SWI after Gd would influence the diagnostic image quality, parenchymal signal and vascular enhancement. An additional aim is to suggest potential future applications for Gd-enhanced SWI.