996 resultados para Moraes Neto, Prudente de, 1904 -


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, numerical simulations are made, using the three-dimensional restricted three-body problem as the mathematical model, to calculate the effects of a swing-by with the planet Saturn in the orbit of a comet. To show the results, the orbit of the comet is classified in four groups: elliptic direct, elliptic retrograde, hyperbolic direct and hyperbolic retrograde. Then, the modification in the orbit of the comet due to the close approach is shown in plots that specify from which group the comet's orbit is coming and to which group it is going. Several families of orbits are found and shown in detail. An analysis about the trends as parameters (position and velocity at the periapse) vary is performed and the influence of each of them is shown and explained. The result is a collection of maps that describe the evolution of the trajectory of the comet due to the close approach. Those maps can be used to estimate the probability of some events, like the capture or escape of a comet. An example of this technique is shown in the paper. (C) 2005 COSPAR. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection system with online sample preparation is proposed for the determination of phosphite in liquid fertilizers by spectrophotometry. After loop-based injection, phosphite is oxidized by an acidic permanganate solution (1.0 10(-2) mol L-1 KMnO4 + 1.0 mol L-1 H2SO4) in a heated reactor (50 degreesC). The phosphate generated is then determined by the molybdenum blue method. Influence of flow rates, temperature, and concentration and order of addition of reagents, sample volume, and reactor configuration for the blue complex formation on recorded signals were investigated. The pow system was applied to phosphite determination in commercial samples of liquid fertilizers. The proposed system handles about 80 samples per hour [0.05-0.40% (w/v) H3PO3; R = 0,9998], consuming about 80 muL sample, 1 mg KMnO4, 25 mg (NH)(6)Mo7O24, and Ia mg ascorbic acid per determination. Results are precise [relative standard deviation less than or equal to 3.5% for 0.1% (w/v) H3PO3, n = 12] and in agreement with those obtained by gravimetry at 95% confidence level. (C) 2000 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is proposed for the simultaneous determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by electrothermal atomic absorption spectrometry (ETAAS) using W-Rh permanent modifier together with Pd(NO3)(2) + Mg(NO3)(2) conventional modifier. The integrated platform of a transversely heated graphite atomizer (THGA) was treated with tungsten, followed by rhodium, forming a deposit containing 250 mug W + 200 mug Rh. A 500-muL, volume of fuel ethanol was diluted with 500 muL, of 0.14 mol L-1 HNO3 in an autosampler cup of the spectrometer. Then, 20 muL, of the diluted ethanol was introduced into the pretreated graphite platform followed by the introduction of 5 mug Pd(NO3)(2) + 3 mug Mg(NO3)(2). The injection of this modifier was required to improve arsenic and iron recoveries in fuel ethanol. Calibrations were carried out using multi-element reference solutions prepared in diluted ethanol (1 + 1, v/v) acidified to 0. 14 mol L-1 HNO3. The pyrolysis and atomization temperatures of the heating program were 1200degreesC and 2200degreesC, respectively, which were obtained with multielement reference solutions in acidic diluted ethanol (1 + 1, v/v; 0. 14 mol L-1 HNO3). The characteristic masses for the simultaneous determination in ethanol fuel were 78 pg Al, 33 pg As, 10 pg Cu, 14 pg Fe, 7 pg Mn, and 24 pg Ni. The lifetime of the pretreated tube was about 700 firings. The detection limits (D.L.) were 1.9 mug L-1 Al, 2.9 mug L-1 As, 0.57 mug L-1.Cu, 1.3 mug L-1 Fe, 0.40 mug L-1 Mn, and 1.3 mug L-1 Ni. The relative standard deviations (n = 12) were 4%, 4%, 3%, 1.5%, 1.2%, and 2.2% for Al, As, Cu, Fe, Mn, and Ni, respectively. The recoveries of Al, As, Cu, Fe, Mn, and Ni added to the fuel ethanol samples varied from 81% to 95%, 80% to 98%, 97% to 109%, 85% to 107%, 98% to 106% and 97% to 103%, respectively. Accuracy was checked for the Al, As, Cu, Fe, Mn, and Ni determination in 10 samples purchased at a local gas station in Araraquara-SP City, Brazil. A paired t-test showed that at the 95% confidence level the results were in agreement with those obtained by single-element ETAAS.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Malpighian tubules of workers of the fire ant Solenopsis saevissima (Myrmicinae) were analyzed by scanning and transmission electron microscopy in order to determine their functional organization and association with the hindgut epithelium. The ants showed six Malpighian tubules with three segments morphologically and structurally different. The proximal segment was long and its cells showed abundant smooth endoplasmic reticulum and lipid droplets, which suggest their role in lipid secretion. The mid segment was long and undulated and it was composed by the cells that showed the typical features of ion transporting epithelia. The distal segment, short and flattened, adheres to the rectum wall. The cells of this segment showed the basal lamina fused to that of the rectum, it is probable that this part of the tubule may play a role in ion and water uptake from the feces. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study is reported between C-18 bonded silica gel and powdered polyethylene (PE) as sorbent for Cd, Cu, and Pb determination using ammonium diethyldithiophosphate (ADTP) as the complexing agent in a flow injection system. The complexes were formed in 0.14 mol L-1 HNO3 and processed in a simple flow system comprising a peristaltic pump, a manual injector-commutator, and a sorbent-packed minicolumn. Ethanol was selected as the eluent and analytes in the eluate were determined by flame atomic absorption spectrometry. The optimum concentration of the complexing agent was 0.1% (m/v) ADTP for Cu and Pb determination using either C-18 or PE, and 0.25% (m/v) ADTP for Cd determination using PE. The sample loading flow rates were 5.0, 3.6, and 3.0 mL min(-1) for Cu, Pb, and Cd, respectively. The best elution flow rate was 6.5 mL min(-1). For a 60-sec preconcentration time, the sampling rate was 40 h(-1) and the enrichment factors of 33, 36, and 11 times (C-18) or 18, 22, and 23 times (PE) were obtained for Cu, Pb, and Cd, respectively. The limits of detection (LOD) were 1.6 mug L-1 Cu, 11 mug L-1 Pb, and 2.0 mug L-1 Cd using C-18 or 2.9 mug L-1 Cu, 19 mug L-1 Pb, and 1.0 mug L-1 Cd using PE, respectively. The relative standard deviations (n = 12) were typically <2%, <2%, and <6% for Cd, Cu, and Pb, respectively. The recoveries of Cd, Cu, and Pb added to wine samples varied from 96-99%, 97-102%, and 90-99%, respectively, using C-18 or PE. Accuracy was checked for Cd, Cu, and Pb determination in six wine samples digested by block digestor and open-vessel microwave-assisted digestion systems. The results revealed that C-18 was more efficient for Cu and Pb determination, while PE was the best sorbent for Cd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proposal of this work was to study the effects of lecithin and soy oil on the fermentative performance of Saccharomyces uvarum I Z 1904, a yeast used in the industrial production of ethanol. High Test Molasses (HTM) was chosen as the fermentation media because it is a substratum that is poor in nutrients, and because it permits one to distinguish the action of lipids from other nutritional factors. The study of the optimization of the concentration of lipids by surface response analysis showed that the lipids favor the performance of the yeast principally when applied separately. Maximum concentrations of the two sources of lipids in the media stimulated the budding rate but did not constitute a protection against cell death. Considering the action of lipids on the cellular parameters studied, the supplementation of the media with 3.0 g/l of soy oil permitted the obtention of maximum responses of cellular viability, budding rate and viability of the buds after 6 successive cycles. In relation to the fermentative parameters, the use of 1.5 g/l of soy oil provided high yields and an equilibrium between the mass of ethanol produced (EM) and the alcoholic yield (Y p/s) , whereas the cellular viability after 6 cycles did not differ statistically from that observed with 3g/l of oil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clay mineral analysis contributed to the mineralogical characterization and stratigraphic setting of continental Cenozoic deposits of central-eastern portion of São Paulo State, southeastern Brazil. These deposits, often thin and discontinuous, comprise the Itaqueri Formation (Cretaceous-Paleogene), Rio Claro Formation (Pliocene) and associated Neocenozoic deposits. X-ray diffractometry provided mineralogical and semiquantitative constitution of clays, while scanning electron microscopy (SEM) provided details about mineralogical constitution, packing of microscopic grains and nature (detrital or diagenetic) of clays. These results supported interpretations about paleoenvironmental conditions during sedimentation, revealing possible links between changing climates (dry or humid) and correlative Cenozoic deposits in southeastern Brazil. In addition, SEM images showed microstructures which influence on geotechnical behaviour (erosion and collapse phenomena) of sedimentary materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leaf discs obtained from the first or second non-cotyledonal leaf of cotton (Gossypium hirsutum L.) seedlings were used for the study of the biology of Polyphagotarsonemus latus on cotton IAC-20 cultivar. Seedlings were grown in pots and placed on a layer of cotton moistened with distilled water. The assays were carried out at 28.5 ± 0.3°C, relative humidity of 71.0 ± 2.6% and a 14 h photophase. The duration of immature phases was 4.1 ± 0.1 days for females and 4.1 ± 0.3 days for males, with a survival of 91.2%. After a pre-oviposition period of 1.1 ± 0.2 days, the females deposited 4.5 ± 0.9 eggs per day during 6.8 ± 1.3 days, i.e., 29.6 ± 7.3 eggs per female. The longevity was 10.0 ± 1.5 days for females and 8.8 ± 1.1 days for males. The intrinsic rate of increase (rm) was 0.323; finite rate of increase (λ) 1.38 individual per female per day; mean generation time (T) 9.54 days and net reproductive rate (Ro) 21.73.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new strategy for minimization of Cu2+ and Pb2+ interferences on the spectrophotometric determination of Cd2+ by the Malachite green (MG)-iodide reaction using electrolytic deposition of interfering species and solid phase extraction of Cd2+ in flow system is proposed. The electrolytic cell comprises two coiled Pt electrodes concentrically assembled. When the sample solution is electrolyzed in a mixed solution containing 5% (v/v) HNO3, 0.1% (v/v) H2SO4 and 0.5 M NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. After electrolysis, the remaining solution passes through an AG1-X8 resin (chloride form) packed minicolumn in which Cd2+ is extracted as CdCl4/2-. Electrolyte compositions, flow rates, timing, applied current, and electrolysis time was investigated. With 60 s electrolysis time, 0.25 A applied current, Pb2+ and Cu2+ levels up to 50 and 250 mg 1-1, respectively, can be tolerated without interference. For 90 s resin loading time, a linear relationship between absorbance and analyte concentration in the 5.00-50.0 μg Cd 1-1 range (r2 = 0.9996) is obtained. A throughput of 20 samples per h is achieved, corresponding to about 0.7 mg MG and 500 mg KI and 5 ml sample consumed per determination. The detection limit is 0.23 μg Cd 1-1. The accuracy was checked for cadmium determination in standard reference materials, vegetables and tap water. Results were in agreement with certified values of standard reference materials and with those obtained by graphite furnace atomic absorption spectrometry at 95% confidence level. The R.S.D. for plant digests and water containing 13.0 μg Cd 1-1 was 3.85% (n = 12). The recoveries of analyte spikes added to the water and vegetable samples ranged from 94 to 104%. (C) 2000 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for the direct and simultaneous determination of As, Cu, Mn, Sb, and Se in drinking water by electrothermal atomic absorption spectrometry (ETAAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of analytes during the pyrolysis and atomization stages was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3 and 1 + 1 (v/v) diluted water using mixtures of Pd(NO3)2 + Mg(NO3)2 as the chemical modifier. With 5 μg Pd + 3 μg Mg as the modifier, the pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1400°C and 2100°C, respectively, and 20 μL of the water sample (sample + 0.28 mol L-1 HNO3, 1 + 1, v/v), dispensed into the graphite tube, analytical curves were established ranging from 5.00 -50.0 μg L-1 for As, Sb, Se; 10.0 - 100 μg L-1 for Cu; and 20.0 - 200 μg L-1 for Mn. The characteristic masses were around 39 pg As, 17 pg Cu, 60 pg Mn, 43 pg Sb, and 45 pg Se, and the lifetime of the tube was around 500 firings. The limits of detection (LOD) based on integrated absorbance (0.7 μg L-1 As, 0.2 μg L-1 Cu, 0.6 μg L-1 Mn, 0.3 μg L-1 Sb, 0.9 μg L-1 Se) exceeded the requirements of the Brazilian Food Regulations (decree # 310-ANVS from the Health Department), which established the maximum permissible level for As, Cu, Mn, Sb, and Se at 50 μg L-1, 1000 μg L-1, 2000 μg L-1, 5 μg L-1, and 50 μg L-1, respectively. The relative standard deviations (n = 12) were typically < 5.3% for As, < 0.5% for Cu, < 2.1% for Mn, < 11.7% for Sb, and < 9.2% for Se. The recoveries of As, Cu, Mn, Sb, and Se added to the mineral water samples varied from 102-111%, 91-107%, 92-109%, 89-97%, and 101-109%, respectively. Accuracy for the determination of As, Cu, Mn, Sb, and Se was checked using standard reference materials NIST SRM 1640 - Trace Elements in Natural Water, NIST SRM 1643d - Trace Elements in Water, and 10 mineral water samples. A paired t-test showed that the results were in agreement with the certified values of the standard reference materials at the 95% confidence level.