960 resultados para MARGINAL DONORS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the frequency of different HLA-DRB1 alleles in Plasmodium vivax-infected individuals and in healthy blood donors from malaria endemic areas of Brazil. Low-resolution human leukocyte antigen-DRB1 genotyping was performed for 73 malaria patients and 29 healthy blood donors. The most frequent alleles in individuals from northern Brazil were human leukocyte antigen-DRB1*04, *08, *07 and *13. The frequency of human leukocyte antigen-DRB1*07 was higher in malaria-infected individuals than in the control group, which reinforces the theory that this allele plays an important role in susceptibility to malaria. This study offers new information about a potential susceptibility factor for P. vivax malaria in a Brazilian population that is naturally exposed to malaria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A metal coping may undergo changes during porcelain firing, which compromises its marginal adaptation. The use of NiCrTi alloy proposes to minimize this effect through the high melting point of titanium present in its composition. This study evaluated the influence of porcelain firing cycle on the marginal adaptation of NiCrTi copings in different preparation designs. Forty standardized metal dies were fabricated with the following combinations finish line/convergence of the axial walls: 1) shoulder/6°; 2) shoulder/20°; 3) sloping shoulder/6°; 4) sloping shoulder/20°. On each die a metal ceramic restoration coping was made. The die/coping set was stabilized with orthodontic elastics, divided into four equidistant areas with three measurement points each and a cementation pressure was simulated. The measurements were taken under a stereomicroscope (32×). After the first measurement, the copings were submitted to sintering cycles simulating porcelain application. For repeated measurements, the same procedures described above were performed. Data were submitted to Student’s-t test, 1-way ANOVA and Tukey´s test (α = 0.05). Adaptation means (µm) before and after porcelain firing in different preparations were: 1) 111.92 and 127.31; 2) 124.15 and 135.48; 3) 122.19 and 138.77; 4) 166.09 and 186.72; respectively. The porcelain firing impaired adaptation, regardless of the preparation design. The preparation in a 20° sloping shoulder provided a worse adaptation when compared with preparations that had 6° and 20° shoulder, which were statistically equal. The 6° sloping shoulder was statistically equal to the other three preparation designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of this paper was to verify if the final irrigation at 17% EDTA, separately or followed by chlorhexidine digluconate at 2% interferes on the apical marginal leakage in root canal overfilling, due to the use of two root canal filling materials (Sealer 26TM or SealapexTM). Methods: Forty lower incisors extracted, with a single root canal, were biomechanically prepared, at 2.0mm beyond the radicular apex, with ProTaper SystemTM, finishing it with the F3 instrument. Irrigation was accomplished with 1.0 mL NaOCl at 2.5% at each change of equipment caliper and, in the end, with 5.0 mL normal saline solution. After achieving this procedure, the foraminal channels was standardized with a file K 25 until its DO appears in the foraminal opening. From this moment, the teeth were subdivided into two groups of 20 specimens each, because of the final irrigation method used: I – irrigation with EDTA at 17% for 3min and II – identical protocol, thus, after EDTA aspiration at17%, it was again irrigated with chlorhexidine digluconate at 2%, also kept intra-canal for 3min. Each group was again sub-divided into two sub-groups (ten teeth each), according to the cement used (Sealer 26TM or SealapexTM), and filled by using a single gutta-percha F1 (ProTaperTM, Universal Filling), in such a manner that it goes 2.0 mm beyond the radicular apex. Soon after that, the teeth were immersed in Rhodamine BTM for 72h, vacuum and after the roots have been bucolingually grooved, the leakages marked were measured with program Image ToolTM. Results and Conclusions: The leakage magnitude was similar among themselves (p > 0.05), except for group Sealapex®, thus the final use with chlorhexidine reduced apical leakage (p < 0.05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to assess the use of chlorhexidine with several excipients as a dentin surface treatment and its effect on marginal adaptation of class V restorations with current-generation dentin bonding agents. A total of 120 human third molars were selected and allocated into 12 groups, with standardized buccal class V restorations randomly divided into preconditioned dentin rinsed with: water; water + chlorhexidine; ethanol; or ethanol + chlorhexidine. After rinsing of dentin (previously conditioned with 35% phosphoric acid) with the test solutions, the Adper single bond 2, prime and bond 2.1, and Excite bonding systems were applied randomly. Restorations were performed with FiltekTM Z350 XT composite resin. The resulting specimens were subjected to thermal and mechanical load cycling. Quantitative analysis of marginal adaptation was performed on epoxy replicas by means of scanning electron microscopy. Results were assessed by means of the Kruskal-Wallis test (percentages of continuous margins) and Wilcoxon test (differences between percentages of continuous margins before and after thermal cycling and mechanical loading), at a significance level of p < 0.05. Outcomes in the chlorhexidine-treated groups were not superior to those obtained with other treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a heterozygous case of Hb I-Philadelphia [alpha 16 (A14) LYS-->GLU] in a blood donor from the Acre State Blood Bank, in the Brazilian Amazon region. We confirmed the mutation by electrophoretic and chromatographic methods and by DNA sequencing. A literature search showed that this is the first description of this alpha globin mutant in a Brazilian Caucasian group. We also emphasize the importance of the hemoglobin study in blood donors for the purpose of the genetic counseling and quality assurance of the blood to be transfused. Screening tests for hemoglobin mutants are also important for gathering anthropological information about the Brazilian population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effect of bovine somatotropin (bST; 500 mg) administration on lactating buffalo donors submitted to two different ovum pick-up (OPU) and in vitro embryo production schemes with a 7 or 14 d intersession OPU interval. A total of 16 lactating buffalo cows were randomly assigned into one of four experimental groups according to the bST treatment (bST or No-bST) and the OPU intersession interval (7 or 14 d) in a 2 x 2 factorial design (16 weeks of OPU sessions). The females submitted to OPU every 14d had a larger (P < 0.001) number of ovarian follicles suitable for puncture (15.6 +/- 0.7 vs. 12.8 +/- 0.4) and an increased (P = 0.004) number of cumulus-oocyte complexes (COCs) recovered (10.0 +/- 0.5 vs. 8.5 +/- 0.3) compared to the 7 d interval group. However, a 7 or 14 d interval between OPU sessions had no effect (P = 0.34) on the number of blastocysts produced per OPU (1.0 +/- 0.1 vs. 13 +/- 0.2, respectively). In addition, bST treatment increased (P < 0.001) the number of ovarian follicles suitable for puncture (15.3 +/- 0.5 vs. 12.1 +/- 0.4) but reduced the percentage (18.9% vs. 10.9%; P = 0.009) and the number (1.4 +/- 0.2 vs. 0.8 +/- 0.1; P = 0.003) of blastocysts produced per OPU session compared with the non-bST-treated buffaloes. In conclusion, the 14d interval between OPU sessions and bST treatment efficiently increased the number of ovarian follicles suitable for puncture. However, the OPU session interval had no effect on embryo production, and bST treatment reduced the in vitro blastocyst outcomes in lactating buffalo donors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Prospective studies evaluating the risk of hepatitis B virus (HBV) transmission in transplants of kidneys from hepatitis B core antibody (anti-HBc)-positive/ hepatitis B surface antibody (anti-HBs) negative donors are still lacking. The objective of this study was to assess the safety of kidney transplantation with the use of anti-HBc positive donors.Methods. This prospective case series study included 50 kidney transplant recipients from anti-HBc positive donors with or without anti-HBs positivity. Recipients were required to test positive for anti-HBs (titers >10 mUI/mL), regardless of anti-HBc status, and negative for hepatitis B surface antigen (HBsAg). Recipient and donor data were retrieved from medical records, databases, and organ procurement organization sheets. Liver function tests were performed at progressively increasing post-transplantation intervals. Complete serologic tests for HBV were performed before transplantation, 3 and 6 months after transplantation, and annually thereafter.Results. Six months after transplantation, all recipients were negative for HBsAg, HBeAg, anti-HBe, and anti-HBcIgM. No seroconversion was observed among the 20 patients who received kidneys from anti-HBc positive/anti-HBs negative donors. No patient showed elevated liver enzymes during follow-up.Conclusions. Kidney transplantation using organs from anti-HBeIgG positive donors (even when they are concurrently anti-HBs negative) in anti-HBs positive recipients is a safe procedure and may be considered as a way to expand the donor pool.