932 resultados para Laboratory wastewaters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The laboratory tests currently available to the clinician for day-to-day management of HIV infection are generally limited to the measurement of the viral load and of the CD4 cell count. More recently, analysis of drug resistance and of plasma drug levels have been added to the monitoring armamentarium. There are, however, numerous other techniques currently available to researchers that may in the future be incorporated into clinical routine. These include the analysis of human and viral genetic determinants of disease evolution, detailed analyses of immune recovery and reserve, pharmacogenetic determinants of treatment response, and toxicity. These approaches may in the future provide highly individualized disease management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sera obtained from 62 patients from four mountain counties in Catalonia (Northeastern Spain), in whom brucellosis had been diagnosed on the basis of clinical evidence and/or personal history, were analyzed using the rose Bengal test, standard serum agglutination test (SAT), Coombs" test, ELISA, and complement fixation. The diagnosis was further confirmed through blood cultures. Clinical evidence, epidemiology, and the results from serologic tests were used to assign patients to one of two groups: group 1 (n = 38) patients had primary infections, whereas group 2 (n = 24) patients had been previously exposed to the microorganism, i.e. re-infection of group 2 individuals occurred after long periods of time during which no active infection by Brucella had been detected. Receivingoperating charts (ROC) were used to determine the diagnostic value of the different tests and to establish discriminant values. Blood culture was a valuable diagnostic tool in group 1 (0.92 sensitivity) but was inappropriate in group 2 (0.08). The combination of positive rose Bengal test and agglutination ≥1/160 was valid for diagnosis in group 1. In group 2, agglutination < 1/160 (including negative agglutination) did not rule out brucellosis. The combination of positive rose Bengal test and Coombs" test ≥1/320 was the best diagnostic criterion (0.8 specificity; 1 sensitivity). ELISA (for IgG, IgM, or both) did not improve diagnostic accuracy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Si le tableau clinique évoque une malaria et que le résultat des examens parasitologiques n?est pas disponible ou est négatif, le praticien n?a pas d?information basée sur l?évidence pour savoir s?il doit donner ou non un traitement présomptif. Afin d?identifier les facteurs cliniques et paracliniques prédictifs d?une parasitémie à Plasmodium, nous avons mené une étude prospective chez les voyageurs ou migrants en provenance d?une zone tropicale ou subtropicale et qui consultaient pour de la fièvre. Le questionnaire comprenait 49 items explorant les données démographiques, les caractéristiques du voyage, les éléments de l?anamnèse et de l?examen clinique ainsi que les résultats de laboratoire. 336 sujets avec données complètes ont été recrutés (97 patients atteints de malaria et 239 contrôles avec fièvre et examen parasitologique négatif). L?analyse de régression multivariée a permis d?identifier les facteurs prédictifs de maiaria suivants : prophylaxie inadéquate, sudations, absence de douleur abdominale, température )38"C, mauvais état général, splénomégalie, compte leucocytaire (1 O x 1 03/L, plaquettes ~ 1 5 0 x l 03/L, taux d?hémoglobine <12 g/dL et éosinophiles (5%. La présence d?une splénomégalie avait le coefficient de probabilité positif pour un diagnostic de malaria le plus élevé (1 3.6) ; venait ensuite la présence d?une thrombopénie (1 1 .O). Dans le contexte de la consultation ambulatoire de la Policlinique Médicale Universitaire (prévalence de malaria de 29%), la probabilité post- test d?avoir un examen parasitologique positif était de 85% pour la splénomégalie et de 82% pour la thrombopénie. Même si le seuil thérapeutique n?est pas absolument défini, il semble raisonnable d?envisager un traitement présomptif lorsque la probabilité post- test est >80%. Si le médecin est réticent à administrer un traitement sans documentation parasitologique, il devrait au moins se retenir d?entreprendre d?autres investigations coûteuses, et plutôt répéter l?examen parasitologique après 12-24 heures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accumulation of aqueous pollutants is becoming a global problem. The search for suitable methods and/or combinations of water treatment processes is a task that can slow down and stop the process of water pollution. In this work, the method of wet oxidation was considered as an appropriate technique for the elimination of the impurities present in paper mill process waters. It has been shown that, when combined with traditional wastewater treatment processes, wet oxidation offers many advantages. The combination of coagulation and wet oxidation offers a new opportunity for the improvement of the quality of wastewater designated for discharge or recycling. First of all, the utilization of coagulated sludge via wet oxidation provides a conditioning process for the sludge, i.e. dewatering, which is rather difficult to carry out with untreated waste. Secondly, Fe2(SO4)3, which is employed earlier as a coagulant, transforms the conventional wet oxidation process into a catalytic one. The use of coagulation as the post-treatment for wet oxidation can offer the possibility of the brown hue that usually accompanies the partial oxidation to be reduced. As a result, the supernatant is less colored and also contains a rather low amount of Fe ions to beconsidered for recycling inside mills. The thickened part that consists of metal ions is then recycled back to the wet oxidation system. It was also observed that wet oxidation is favorable for the degradation of pitch substances (LWEs) and lignin that are present in the process waters of paper mills. Rather low operating temperatures are needed for wet oxidation in order to destruct LWEs. The oxidation in the alkaline media provides not only the faster elimination of pitch and lignin but also significantly improves the biodegradable characteristics of wastewater that contains lignin and pitch substances. During the course of the kinetic studies, a model, which can predict the enhancements of the biodegradability of wastewater, was elaborated. The model includes lumped concentrations suchas the chemical oxygen demand and biochemical oxygen demand and reflects a generalized reaction network of oxidative transformations. Later developments incorporated a new lump, the immediately available biochemical oxygen demand, which increased the fidelity of the predictions made by the model. Since changes in biodegradability occur simultaneously with the destruction of LWEs, an attempt was made to combine these two facts for modeling purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis the membrane filtration equipment for plate type ceramic membranes was developed based on filtration results achieved with different kinds of wastewaters. The experiments were mainly made with pulp and board mill wastewaters, but some experiments were also made with a bore well water and a stone cutting mine wastewater. The ceramicmembranes used were alpha-alumina membranes with a pore size of 100 nm. Some ofthe membranes were coated with a gamma-alumina layer to reduce the membrane pore size to 10 nm, and some of them were modified with different metal oxides in order to change the surface properties of the membranes. The effects of operationparameters, such as cross-flow velocity, filtration pressure and backflushing on filtration performance were studied. The measured parameters were the permeateflux, the quality of the permeate, as well as the fouling tendency of the membrane. A dynamic membrane or a cake layer forming on top of the membrane was observed to decrease the flux and increase separa-tion of certain substances, especially at low cross-flow velocities. When the cross-flow velocities were increased the membrane properties became more important. Backflushing could also be used to decrease the thickness of the cake layer and thus it improved the permeate flux. However, backflushing can lead to a reduction of retentions in cases where the cake layer is improving them. The wastewater quality was important for the thickness of the dynamic membrane and the membrane pore size influenced the permeate flux. In general, the optimization of operation conditions is very important for the successful operation of a membrane filtration system. The filtration equipment with a reasonable range of operational conditions is necessary, especiallywhen different kinds of wastewaters are treated. This should be taken into account already in the development stage of a filtration equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical analysis is a well-established procedure for the provenancing of archaeological ceramics. Various analytical techniques are routinely used and large amounts of data have been accumulated so far in data banks. However, in order to exchange results obtained by different laboratories, the respective analytical procedures need to be tested in terms of their inter-comparability. In this study, the schemes of analysis used in four laboratories that are involved in archaeological pottery studies on a routine basis were compared. The techniques investigated were neutron activation analysis (NAA), X-ray fluorescence analysis (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). For this comparison series of measurements on different geological standard reference materials (SRM) were carried out and the results were statistically evaluated. An attempt was also made towards the establishment of calibration factors between pairs of analytical setups in order to smooth the systematic differences among the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the rift between Jevons and Mill over the method of political economy serves as a prehistory to recent attempts of behavioural economists to once again explain economic behaviour by taking recourse to mankind's physiology. While Mill relied on the association psychology and its introspective method to establish indubitable first principles, Jevons scorned all recourse to introspection. As exemplified for Jevons's theory of labour, psychophysiology gave Jevons the means to think about economic behaviour in terms of functional form, and promised its assessment by means of experiments. Thus levelling down the Victorian distinction between mind and matter, Jevons turned political economy into social physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the formation of transformation products (TPs) by the enzymatic degradation at laboratory scale of two highly consumed antibiotics: tetracycline (Tc) and erythromycin (ERY). The analysis of the samples was carried out by a fast and simple method based on the novel configuration of the on-line turbulent flow system coupled to a hybrid linear ion trap – high resolution mass spectrometer. The method was optimized and validated for the complete analysis of ERY, Tc and their transformation products within 10 min without any other sample manipulation. Furthermore, the applicability of the on-line procedure was evaluated for 25 additional antibiotics, covering a wide range of chemical classes in different environmental waters with satisfactory quality parameters. Degradation rates obtained for Tc by laccase enzyme and ERY by EreB esterase enzyme without the presence of mediators were ∼78% and ∼50%, respectively. Concerning the identification of TPs, three suspected compounds for Tc and five of ERY have been proposed. In the case of Tc, the tentative molecular formulas with errors mass within 2 ppm have been based on the hypothesis of dehydroxylation, (bi)demethylation and oxidation of the rings A and C as major reactions. In contrast, the major TP detected for ERY has been identified as the “dehydration ERY-A”, with the same molecular formula of its parent compound. In addition, the evaluation of the antibiotic activity of the samples along the enzymatic treatments showed a decrease around 100% in both cases

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. METHODS: Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. RESULTS: By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. CONCLUSIONS: By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.