999 resultados para Laboratório de Eletroquímica e Células a Combustível da Universidade Federal do Pará - LECaC–UFPA


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of wireless telecommunication in the last years has been great. It has been taking academics to conceive new ideas and techniques. Their aims are to increase the capacity and the quality of the system s services. Cells that are smaller every time, frequencies that are every time higher and environments that get more and more complex, all those facts deserve more accurate models the propagation prediction techniques are inserted in this context and results with a merger of error that is compatible with the next generations of communication systems. The objective of this Work is to present results of a propagation measurement campaign, aiming at pointing the characteristics of the mobile systems covering in the city of Natal (state of Rio Grande do Norte, Brazil). A mobile laboratory was set up, using the infra-structure available and frequently used by ANATEL. The measures were taken in three different areas: one characterized by high buildings, high relief, presence of trees and towers of different highs. These areas covered the city s central zone, a suburban / rural zone and a section of coast surrounded by sand dunes. It is important to highlight that the analysis was made taking into consideration the actual reality of cellular systems with covering ranges by reduced cells, with the intent of causing greater re-use of frequencies and greater capacity of telephone traffic. The predominance of telephone traffic by cell in the city of Natal occurs within a range inferior to 3 (three) km from the Radio-Base Station. The frequency band used was 800 MHz, corresponding to the control channels of the respective sites, which adopt the FSK modulation technique. This Dissertation starts by presenting a general vision of the models used for predicting propagation. Then, there is a description of the methodology used in the measuring, which were done using the same channels of control of the cellular system. The results obtained were compared with many existing prediction models, and some adaptations were developed by using regression techniques trying to obtain the most optimized solutions. Furthermore, according to regulations from the old Brazilian Holding Telebrás, a minimum covering of 90% of a determined previously area, in 90% of the time, must be obeyed when implanting cellular systems. For such value to be reached, considerations and studies involving the specific environment that is being covered are important. The objective of this work is contribute to this aspect

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foi estudado o consumo de combustível de diferentes sistemas de preparo periódico, realizados antes e depois da operação de subsolagem num solo classificado como Nitossolo Vermelho Distroférrico. As operações de preparo foram: a) 1 aração com arado de discos; b) 1 aração com arado de discos e 1 gradagem com grade destorroadora-niveladora; c) 1 gradagem com grade aradora; d) 1 gradagem com grade aradora e 1 gradagem com grade destorroadora-niveladora e; e) 1 escarificação com escarificador. O consumo específico (g kWh-1) de combustível para os diferentes sistemas de preparo periódico do solo variou estatisticamente com a condição de subsolagem realizada antes e depois. A escarificação proporcionou menor volume de combustível requerido por hectare (L ha-1) que os demais sistemas de preparo. O preparo do solo depois da subsolagem obteve um maior volume de combustível consumido por área (L ha-1).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The considered work presents the procedure for evaluation of the uncertainty related to the calibration of flow measurers and to BS&W. It is about a new method of measurement purposed by the conceptual project of the laboratory LAMP, at Universidade Federal do Rio Grande do Norte, that intends to determine the conventional true value of the BS&W from the total height of the liquid column in the auditor tank, hydrostatic pressure exerted by the liquid column, local gravity, specific mass of the water and the specific mass of the oil, and, to determine the flow, from total height of liquid column and transfer time. The calibration uses a automatized system of monitoration and data acquisition of some necessary largnesses to determine of flow and BS&W, allowing a better trustworthiness of through measurements

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conversion of solar energy in electric with photo-voltaic cells has been carried through exclusively with devices of semiconducting junction. To put this situation comes moving for better in them last years, thanks to a new technology of production of known solar cells as Dye Solar Cell. This proposal aims at to develop a DSC having as dye lavonoides of the Capsicum frutescens (malagueta pepper). Front is considered to evaluate the photo-voltaic parameters varies it regions of the visible specter, as well as a good efficiency of conversion

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flex-fuel vehicles are equipped with Otto Cycle internal combustion engines and have the capability of functioning with more than one type of fuel, mixed at the same tank and burned in the combustion chamber simultaneously. This sort of motorization is a world pattern due to the scarcity of petroleum, the trade of several types of fuels, technology advances and the restriction imposed to gas emissions to the atmosphere. In Brazil, the Flexfuel vehicles are a reality, specially the ones using fuel with 20 to 25% anhydrous alcohol mixed with gasoline and those that use natural gas or original liquid fuel (gasoline or hydrated ethanol). The Brazilian model Fiat Siena, the object of this present scientific investigation, is equipped with a unique electronic central capable of managing the liquid or gaseous fuels. The purpose of this research was to perform a comparative analysis in terms of performance (in terms of both potency and consumption) of a tetra-fuel vehicle - using a chassis dynamometer, operating with different fuels: common gasoline, premium gasoline, Podium gasoline, ethanol or natural gas. It became necessary to develop a bench of tests and trials procedures, as well as to know the functioning of the electronic management of the vehicle under analysis. The experiments were performed at the automotive laboratory in CTGAS-ER (Center of Gas Technologies and Renewable energies) at the light of Brazilian standard ABNT, NBR 7024: Light on-road vehicles - measurement of fuel consumption. The essay results on specific fuel consumption using common gasoline, premium gasoline and Podium gasoline have shown similar results, both for urban and road driving cycles

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The great importance in selecting the profile of an aircraft wing concerns the fact that its relevance in the performance thereof; influencing this displacement costs (fuel consumption, flight level, for example), the conditions of flight safety (response in critical condition) of the plane. The aim of this study was to examine the aerodynamic parameters that affect some types of wing profile, based on wind tunnel testing, to determine the aerodynamic efficiency of each one of them. We compared three types of planforms, chosen from considerations about the characteristics of the aircraft model. One of them has a common setup, and very common in laboratory classes to be a sort of standard aerodynamic, it is a symmetrical profile. The second profile shows a conFiguration of the concave-convex type, the third is also a concave-convex profile, but with different implementation of the second, and finally, the fourth airfoil profile has a plano-convex. Thus, three different categories are covered in profile, showing the main points of relevance to their employment. To perform the experiment used a wind tunnel-type open circuit, where we analyzed the pressure distribution across the surface of each profile. Possession of the drag polar of each wing profile can be, from the theoretical basis of this work, the aerodynamic characteristics relate to the expected performance of the experimental aircraft, thus creating a selection model with guaranteed performance aerodynamics. It is believed that the philosophy used in this dissertation research validates the results, resulting in an experimental alternative for reliable implementation of aerodynamic testing in models of planforms

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the waste generated in the petrochemical industry water associated with oil production is the most important. It is considered one of the great challenges due to the presence of considered toxic chemicals present in this composition. The presence of these substances difficult to reuse the water associated with the enhanced recovery processes, so that prior to their reuse or disposal, treatment is necessary. This paper aimed to study the removal efficiency of chemical species: Ba2+, Ni2+, Cd2+, Cu2+, Cr3+, Sr2+ and Zn2+, present in the composition of the water associated with oil production by electrocoagulation. The evaluation of removal of these chemical species was performed by laboratory tests using electrochemical batch reactors and continuous flow. Initial tests were performed with electrocoagulation of synthetic wastewater in batch reactor using iron electrode. Results of removal of Zn2+ and Ni2+ were 78 % and 59 % respectively. While the percentage of removed Ba2+ was 19 % by 30 minutes of treatment and by applying current of 1.10 A. The tests were performed on effluent batch reactor applying the electrochemical technique with stainless steel electrodes 304, the objective was to remove part of the dispersed oil and also of organic compounds in the effluent. Under the experimental conditions used, the maximum result was obtained TOG was 60 % and TOC was approximately 50 % compared to the initial concentration. In the experiments carried out in continuous reactor, with effluent semisynthetic, have been used electrodes of iron and aluminum and the results were 100 % removal of Cd2+, Cu2+, Cr3+ and Zn2+ and 77 % of Sr2+. These percentages were only attainable through the use of the iron electrode. However, when the electrode was replaced by aluminum, there was a reduction in the percentage of removal to 65 %, using the same flow rate and current. Therefore according to the results obtained using the iron electrode was more effective in removing these metals and the conditions of lower current and lower flow rate was satisfactory, as observed in the experimental design adopted

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this approach is to describe the design and construction of a low-cost automated water sampler prototype. In recent years, there is an increasing need on the use of automated equipments for hydro climatic variables to be use in urban and rural environments. Such devices are always used to provide measured information which is of crucial importance on the development of water resources strategies at watershed scale. Actually, many research and water public institutions have been using these kinds of equipments. In most of the cases, automated equipments are expensive and need to be imported, generating a situation of technologic dependency. The prototype is based on an electronic system which controls a peristaltic pump functioning, five solenoid valves and an ultrasonic sensor connected to a datalloger. An interface with the user allows communication with a PC, when the equipment functioning parameters can be provided. The equipment has a hydraulic module composed by a 12V peristaltic pump connected to a distribution circuit composed by five solenoid valves, one of them being used to clean the circuit before each sampling procedure. Samples are collected by four 1.95 polyethylene bottles. The sampler body was made of acrylic material, with a cylindrical shape, and dimensions 0.72 m and 0.38 m height and diameter, respectively. The weight of the equipment without samples is approximately 15 kg, which infers to its portability. The prototype development total cost budget was approximately US$ 1,560.00. Laboratory tests aimed to evaluate the equipment performance and functioning demonstrated satisfactory results

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eutrophication is a growing process present in the water sources located in the northeast of Brazil. Among the main consequences of these changes in trophic levels of a water source, stands out adding complexity to the treatment to achieve water standards. By these considerations, this study aimed to define, on a laboratory scale, products and operational conditions to be applied in the processing steps using raw water from Gargalheiras dam, RN, Brazil. The dam mentioned shows a high number of cyanobacteria, with a concentration of cells / ml higher than that established by Decree No. 518/04 MS. The same source was also considered by the state environmental agency in 2009 as hypereutrophic. The static tests developed in this research simulated direct filtration (laboratory filters) and pre-oxidation with chlorine and powdered activated carbon adsorption. The research included the evaluation of the coagulants aluminum hydrochloride (HCA) and alum (SA). The development of the research investigated the conditions for rapid mixing, the dosages of coagulants and pHs of coagulation by the drawing of diagrams. The interference of filtration rate and particle size of filtering means were evaluated as samples and the time of contact were tested with chlorine and activated carbon. By the results of the characterization of the raw water source it was possible to identify the presence of a high pH (7.34). The true color was significant (29 uH) in relation to the apparent color and turbidity (66 uH and 13.60 NTU), reflecting in the measurement of organic matter: MON (8.41 mg.L-1) and Abs254 (0.065 cm-1). The optimization of quick mix set time of 17", the speed gradient of 700 s-1 in the coagulation with HCA and the time of 20" with speed gradient of 800 s-1 for SA. The smaller particle sizes of sand filtering means helped the treatment and the variation in filtration rate did not affect significantly the efficiency of the process. The evaluation of the processing steps found adjustment in standard color and turbidity of the Decree nº 518/04 MS, taking in consideration the average values found in raw water. In the treatment using the HCA for direct filtration the palatable pattern based on the apparent color can be achieved with a dose of 25 mg L-1. With the addition of pre-oxidation step, the standard result was achieved with a reduced dose for 12 mgHCA.L-1. The turbidity standard for water was obtained by direct filtration when the dose exceeds 25 mg L-1 of HCA. With pre-oxidation step there is the possibility of reducing the dose to 20 mg L-1.The addition of CAP adsorption, promoted drinking water for both parameters, with even lower dosage, 13 mg L-1 of HCA. With coagulation using SA removal required for the parameter of apparent color it was achieved with pre-oxidation and 22 mgSA.L-1. Despite the satisfactory results of treatment with the alum, it was not possible to provide water with turbidity less than 1.00 NTU even with the use of all stages of treatment

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mesenchymal stem cells (MSCs) are known as a population of multi-potential cells able to proliferate and differentiate into multiple mesodermal tissues including bone, cartilage, muscle, ligament, tendon, fat and stroma. Several applications of the study of EC can be emphasized the therapeutic techniques such as guided bone regeneration by implantation of EC in the affected site, without the need for bone grafts, using titanium as a vehicle. The process of cryopreservation is essential for the maintenance of cell cultures, since the cell line is frozen, it can be maintained in liquid nitrogen for an indefinite period and then thawed for therapeutic or experimental purposes. The aim of this study was to isolate a population of MSCs derived from the subendothelium of the umbilical vein human (MSCs-SUVH) to assess cytogenetic analysis by the possibility of appearance of chromosomal changes in two different situations: MSCs-SUVH regarding the process of cryopreservation and MSCs-SUVH grown on the surface of titanium. Flow cytometry analysis revealed that, this cell population was positive for the markers CD29, CD73 and CD90, but there was no expression of hematopoietic lineage markers, such as CD14, CD34 and CD45 and demonstrated capacity for osteogenic differentiation. The chromosomes obtained from the primary culture of MSCs-SUVH were analyzed by GTW banding technique, and results are described as guidelines to ISCN 2005. There was not the emergence of clonal chromosomal changes in the MSCs-SUVH in different situations analyzed. However one of the strings presented a balanced paracentric inversion, probably a cytogenetic constitutional alterations, which was present before and after the experimental situations that the MSCs-SUVH was submitted

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present experiment used cell culture to analyze the adhesion capacity of mouse mesenchymal bone marrow cells and rat periodontal ligament to different titanium surfaces. Grade II ASTM F86 titanium discs 15mm in diameter and 1.5mm thick were used and received 2 distinct surface treatments (polished and cathodic cage plasma nitriding). The cells were isolated from the mouse bone marrow and rat periodontal ligament and cultured in α-MEM basic culture medium containing antibiotics and supplemented with 10% FBS and 5% CO2, for 72 hours at 37ºC in a humidified atmosphere. Subculture cells were cultured in a 24-well plate with a density of 1 x 104 cells per well. The titanium discs were distributed in accordance with the groups, including positive controls without titanium discs. After a 24-hour culture, the cells were counted in a Neubauer chamber. The results show that both the mouse mesenchymal bone marrow cells and rat periodontal ligament cells had better adhesion to the control surface. The number of bone marrow cells adhered to the polished Ti surface was not statistically significant when compared to the same type of cell adhered to the Ti surface treated by cathodic cage plasma nitriding. However a significant difference was found between the control and polished Ti groups. In relation to periodontal ligament cell adhesion, a significant difference was only found between the control and plasma-treated Ti surfaces. When comparing equal surfaces with different cells, no statistically significant difference was observed. We can therefore conclude that titanium is a good material for mesenchymal cell adhesion and that different material surface treatments can influence this process

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cryopreservation is a process where cells or biological tissues are preserved by freezing at very low temperatures and aims to cease reversibly, in a controlled manner, all the biological functions of living tissues, i.e., maintain cell preservation so that it can recover with high degree of viability and functional integrity. This study aimed to evaluate the influence of cryopreservation on the mesenchymal stem cells originating from the periodontal ligament of human third molars by in vitro experiments. Six healthy teeth were removed and the periodontal cells grown in culture medium containing α-MEM supplemented with antibiotics and 15% FBS in a humidified atmosphere with 5% CO2 at 37° C. Cells isolated from each sample were divided into two groups: Group I - immediate cell culture (not fresh cryopreserved cells) and Group II - cell cryopreservation, during a period of 30 days. Analyses of rates of cell adhesion and proliferation in different groups were performed by counting the cells adhered to the wells, in intervals of 24, 48 and 72 hours after the start of cultivation. The number of cells in each well was obtained by counting viable cells with the use of hemocytometer and the method of exclusion of cells stained by trypan blue. The difference between groups for each of the times was analyzed by Wilcoxon test. Regarding the temporal evolution for each group, analysis was done by Friedman's test to verify the existence of differences between times and, when it existed, the Wilcoxon penalty was applied. The results showed no statistically significant difference between the two groups analyzed in this study. Therefore, we conclude that the cryopreservation process, after a period of 30 days, did not influence the cell type studied, and there was no difference in growth capacity in vitro between the groups

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last years, many scientific researches in implantology have been focused on alternatives that would provide higher speed and quality in the process of osseointegration. Different treatment methods can be used to modify the topographic and chemical properties of titanium surface in order to optimize the tissue-implant reactions by a positive tissue response. This study aimed to evaluate the adhesion and proliferation of mesenchymal cells from human periodontal ligament on two different titanium surfaces, using cell culture techniques. Grade II titanium discs received different surface treatments, forming two distinct groups: polished and cathodic cage plasma nitriding. Human periodontal ligament mesenchymal cells were cultured on titanium discs in 24-well cell culture plates, at a density of 2 x 104 cells per well, including wells with no discs as positive control. Data obtained by counting the cells that adhered to the titanium surfaces (polished group and cathodic cage group) and to the plastic surface (control group), in the 24, 48 and 72-hour periods after plating, were used to analyze cell adhesion and proliferation and to obtain the cell growing curve in the different groups. The data were submitted to nonparametric analysis and the differences between groups were compared by Kruskal-Wallis and Friedman statistical tests. No statistically significant differences were found in the cells counts between the groups (p>0.05). It was concluded that both treatments produced surfaces compatible with the adhesion and proliferation of human periodontal ligament mesenchymal cells

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The oral manifestations due to HIV infection are, a lot of times, the first clinical signs of the disease. These injuries may also function as beepers and sentries of the curse and progression of the HIV infection and AIDS. The objective of this work was to evaluate the prevalence of the oral injuries in HIV positive patients, relating them with the CD4+ cells counting and the viral load in patients from the Hospital of Infected contagious Gizelda Trigueiro in Natal-RN. One hundred and one patients were evaluated, where after the clinical exam of the oral cavity, these ones were conducted to the peripheral blood collection for the counting of CD4+ lymphocytes. We observed a prevalence of 25,6%, that is, 31 cases. The Oral Candidiasis was the most commum injure, followed by Oral Hairy Leukoplakia, linear gingival erytema, lips herpes, gingivitis and periodontitis - HIV. The average counting of cells CD4+ of the injury carrying patients was of 250 cells/mm3. We did not observe relation between the presence of injuries and the viral load of the individuals