918 resultados para KOOP HARDNESS
Resumo:
Chemical modification of cassava starch was conducted through an acylation reaction by using pyridine and propionic anhydride to replace the functional groups of starch. Polyurethane elastomers were prepared using suspensions of the mixture obtained from castor oil and yucca starch that was modified by a propionic anhydride reaction. The suspensions were characterized by means of tests based on The Fourier Transform Infrared Spectroscopy and the Hydroxyl Index. The castor oil-AMP suspensions were used for the PU synthesis. The PUs were characterized by their physical-mechanical properties like tension- deformation and Shore A. hardness, thermal gravimetric analysis and swelling test. The density cross-linking of from swelling tests was determined by applying the Flory-Rehner equation.
Resumo:
Interlaboratorial comparison of the determination of hardness and chloride in water had been performed by 38 and 37 laboratories, respectively. In all cases the participating laboratories used its routine methods. Homogeneity and stability testing were performed on the samples sent to the laboratories. The codified results are graphically reported and compared to assigned value, determined by the consensus of the laboratories. Satisfactory results were obtained for 71 and 73% of the laboratories, considering hardness and chloride determination, respectively.
Resumo:
The goal of this work was to develop a homemade device to desalinate brackish water, using biological material like seeds from different plant species of the semi arid regions. Umbu seeds (Spondias tuberosa Arruda Câmara) were found to be the most appropriate material, removing a higher quantity of salt from the water compared to the other tested materials. The salt content in 1 L of brackish water typical of the region can be removed with only 1 g of the material, if the water is heated to 50 °C and it may also lower the water hardness, achieving drinking water standards.
Resumo:
Lead and copper concentrations in drinking water increase considerably on going from municipality reservoirs to the households sampled in Ribeirão Preto (SP-Brazil). Flushing of only 3 liters of water reduced metal concentrations by more than 50%. Relatively small changes in water pH rapidly affected corrosion processes in lead pipes, while water hardness appeared to have a long-term effect. This approach aims to encourage University teachers to use its content as a case study in disciplines of Instrumental Analytical Chemistry and consequently increase knowledge about drinking water contamination in locations where no public monitoring of trace metals is in place.
Adhesivos tipo poliuretano obtenidos a partir de aceite de ricino y almidón químicamente modificados
Resumo:
This study reports the preparation of polyurethane adhesives using polyols obtained from castor oil modified by a transesterification reaction with pentaerythritol and starch modified by glycosylation. The physical properties of the polyols such as hydroxyl value were determined and the infrared spectroscopic analysis of the polyols reported. The effect of varying the hydroxyl value in the polyols on physical properties of polyurethane coatings on wood and steel panels was determined. The characterization of polyurethane coatings carried out by IR spectroscopic analysis, scratch hardness resistance, impact resistance, lap shear strength, T-peel strength measurements, solvent resistance and chemical resistant determination were reported.
Resumo:
Kirjallisuusarvostelu
Resumo:
Biodegradable polyurethanes (PUR) were prepared from polyols derived from castor oil by transesterification of pentaerythritol-modified castor oil and lysine polyisocyanates (LDI and LTI). The polyurethanes obtained were characterized by Fourier transform infrared spectroscopy, thermogravimetric analysis (TGA), and dynamic mechanical thermal analysis (DMTA). The mechanical behavior of the polyurethanes was measured by Shore A hardness and tensile testing (stress-strain curves). The biodegradable nature of the material was determined by contact angle, water absorption tests, and in vitro degradation in PBS solution. This study aims to examine the effect of the structure and functionality of diisocyanate on the mechanical properties and in vitro degradation of the material. The results were compared with homologous materials obtained from isophorone diisocyanate (IPDI) used in previous works. The objective was to evaluate candidate materials that can be potentially used in tissue engineering.
Resumo:
In this work, we studied the reactivity of picloram in the aqueous phase at the B3LYP/6-311++G(2d,2p) and MP2/6-311++G(2d,2p) levels of theory through global and local reactivity descriptors. The results obtained at the MP2 level indicate that the cationic form of picloram exhibits the highest hardness while the anionic form is the most nucleophilic. From the Fukui function values, the most reactive site for electrophilic and free radical attacks are on the nitrogen in the pyridine ring. The more reactive sites for nucleophilic attacks are located on the nitrogen atom of the amide group and on the carbon atoms located at positions 2 and 3 in the pyridine ring.
Resumo:
Ni–W–P electrodeposits were synthesized in a Hull cell in order to simulate the obtainment under industrial conditions. Complete coverage of panels was accomplished by applying total currents of 1.0 and 2.0 A. Panels obtained with a current of 1.0 A appeared brighter. The best compositional uniformities, as determined by Energy Dispersive Spectrometer (EDS) occurred in the current density ranges of 0.6 to 3.0 A dm−2 and 1.6 to 6.0 A dm−2 obtained with 1.0 and 2.0 A, respectively. However, the best morphological characteristics, as determined by Scanning Electro Microscope (SEM), were observed in those obtained with a total current of 1.0 A. Analysis of corrosion resistance by Electrochemical Impedance Spectroscopy (EIS) and Potentiodynamic Linear Polarization (PLP) in NaCl have shown significant variations in the amount of corrosion potential, polarization resistance, and even total impedance. The alloys exhibited amorphous character (XRD) and crystallized above 400 °C to Ni and Ni3P phases, and possibly Ni–W, with a subsequent increase in hardness. The results suggest that under industrial conditions, current density variations due to the large and complex geometric shapes of substrates lead to formation of distinct alloys. Furthermore, these materials are potential substitutes for chromium deposits in many applications.
Resumo:
Ceramics are widely used in industrial applications due to their advantageous thermal and mechanical stability. Corrosion of ceramics is a great problem resulting in significant costs. Coating is one method of reducing adversities of corrosion. There are several different thin film deposition processes available such as sol-gel, Physical and Chemical Vapour Deposition (PVD and CVD). One of the CVD processes, called Atomic Layer Deposition (ALD) stands out for its excellent controllability, accuracy and wide process capability. The most commonly mentioned disadvantage of this method is its slowness which is partly compensated by its capability of processing large areas at once. Several factors affect the ALD process. Such factors include temperature, the grade of precursors, pulse-purge times and flux of precursors as well as the substrate used. Wrongly chosen process factors may cause loss of self-limiting growth and thus, non-uniformities in the deposited film. Porous substrates require longer pulse times than flat surfaces. The goal of this thesis was to examine the effects of ALD films on surface properties of a porous ceramic material. The analyses applied were for permeability, bubble point pressure and isoelectric point. In addition, effects of the films on corrosion resistance of the substrate in aqueous environment were investigated. After being exposured to different corrosive media the ceramics and liquid samples collected were analysed both mechanically and chemically. Visual and contentual differences between the exposed and coated ceramics versus the untreated and uncoated ones were analysed by scanning electron microscope. Two ALD film materials, dialuminium trioxide and titanium dioxide were deposited on the ceramic substrate using different pulse times. The results of both film materials indicated that surface properties of the ceramic material can be modified to some extent by the ALD method. The effect of the titanium oxide film on the corrosion resistance of the ceramic samples was observed to be fairly small regardless of the pulse time.
Resumo:
Solid-state silicon detectors have replaced conventional ones in almost all recent high-energy physics experiments. Pixel silicon sensors don't have any alternative in the area near the interaction point because of their high resolution and fast operation speed. However, present detectors hardly withstand high radiation doses. Forthcoming upgrade of the LHC in 2014 requires development of a new generation of pixel detectors which will be able to operate under ten times increased luminosity. A planar fabrication technique has some physical limitations; an improvement of the radiation hardness will reduce sensitivity of a detector. In that case a 3D pixel detector seems to be the most promising device which can overcome these difficulties. The objective of this work was to model a structure of the 3D stripixel detector and to simulate electrical characteristics of the device. Silvaco Atlas software has been used for these purposes. The structures of single and double sided dual column detectors with active edges were described using special command language. Simulations of these detectors have shown that electric field inside an active area has more uniform distribution in comparison to the planar structure. A smaller interelectrode space leads to a stronger field and also decreases the collection time. This makes the new type of detectors more radiation resistant. Other discovered advantages are the lower full depletion voltage and increased charge collection efficiency. So the 3D stripixel detectors have demonstrated improved characteristics and will be a suitable replacement for the planar ones.
Resumo:
Tämän diplomityön tavoitteena oli selvittää puupohjaisten kuitukomposiittimateriaalien soveltuvuutta veneteollisuuden valmistusmateriaaliksi. Huviveneiden rakennusta säätelee huvivenedirektiivi ja lukuisat standardit. Standardien mukaan uusien materiaalien käyttö veneenrakennuksessa on mahdollista, mikäli materiaalin ominaisuudet todetaan muun muassa laboratoriotesteissä soveltuviksi kyseiseen käyttötarkoitukseen. Tutkimusta varten valmistettiin kuusi erilaista kuitukomposiittimateriaalia. Tutkimuksessa käytettiin myös neljän kaupallisen puumuovikomposiittivalmistajan materiaalia. Vertailumateriaaleiksi valittiin puuraaka-aineista mänty, saarni ja mahonki sekä muoviraakaaineista ABS – muovi. Tarkisteltaville materiaaleille määriteltiin standardien mukaisin testein taivutuslujuus, vetolujuus, Charpy – iskulujuus, Brinell – kovuus, veden absorptio sekä paksuusturpoama. Saatuja arvoja vertailtiin vertailumateriaalien kirjallisuudessa mainittuihin arvoihin. Puupohjaisten kuitukomposiittien ominaisuudet jäivät vertailumateriaalien vastaavista lukuun ottamatta Brinell – kovuutta. Taivutus- ja vetolujuuden osalta eräiden kaupallisten puumuovikomposiittivalmistajien ilmoittamat lujuusarvot olivat lähellä veneenrakennuksessa käytettyjen materiaalien vastaavia. Suurimpana yksittäisenä haasteena puukuitupohjaisilla kuitukomposiiteilla havaittiin Charpy – iskulujuus. Myös veden absorption saattaminen alhaiseksi havaittiin tärkeäksi veneilysovelluksissa. Ominaisuuksien kehittäminen on kuitenkin käytettävissä olevan tutkimustiedon perusteella mahdollista. Diplomityössä saatujen tulosten perusteella on puupohjaisilla kuitukomposiiteilla potentiaalia veneteollisuudessa. Jatkotutkimusta tulisikin kohdistaa materiaalin ominaisuuksien kehittämiseen.
Resumo:
Polymeric materials have been used in dental applications for decades. Adhesion of polymeric materials to each other and to the tooth substrate is essential to their successful use. The aim of this series of studies was two-folded. First, to improve adhesion of poly(paraphenylene) based rigid rod polymer (RRP) to other dental polymers, and secondly, to evaluate the usability of a new dentin primer system based on RRP fillers. Poly(paraphenylene) based RRP would be a tempting material for dental applications because of its good mechanical properties. To be used in dental applications, reliable adhesion between RRP and other dental polymers is required. In this series of studies, the adhesion of RRP to denture base polymer and the mechanical properties of RRP-denture base polymer-material combination were evaluated. Also adhesion of BisGMA-TEGDMA-resin to RRP was determined. Different surface treatments were tested to improve the adhesion of BisGMA-TEGDMA-resin to RRP. Results were based on three-point bending testing, Vickers surface hardness test and scanning electron microscope analysis (SEM), which showed that no reliable adhesion between RRP and denture base polymer was formed. Addition of RRP filler to denture base polymer increased surface hardness and flexural modulus but flexural strength decreased. Results from the shear bond strength test and SEM revealed that adhesion between resin and RRP was possible to improve by surface treatment with dichloromethane (DCM) based primer and a new kind of adhesive surface can be designed. The current dentin bonding agents have good immediate bond strength, but in long term the bond strength may decrease due to the detrimental effect of water and perhaps by matrix metalloproteinases. This leads to problems in longevity of restorations. Current bonding agents use organic monomers. In this series of studies, RRP filled dentin primer was tested in order to decrease the water sorption of the monomer system of the primers. The properties of new dentin primer system were evaluated in vitro by comparing it to commercial etch and rinse adhesive system. The results from the contact angle measurements and SEM showed that experimental primer with RRP reinforcement provided similar resin infiltration to dentin collagen and formed the resin-dentin interface as the control primer. Microtensile bond strength test and SEM revealed that in short term water storing, RRP increased bond strength and primer with BMEP-monomer (bis[2-(methacryloyloxy)-ethyl]phosphate) and high solvent concentration provided comparable bonding properties to the commercial control primers. In long term water storing, the high solvent-monomer concentration of the experimental primers decreased bond strength. However, in low solvent-monomer concentration groups, the long-term water storing did not decrease the bond strength despite the existence of hydrophilic monomers which were used in the system. These studies demonstrated that new dentin primer system reached the mechanical properties of current traditional etch and rinse adhesive system in short time water storing. Improved properties can be achieved by further modifications of the monomer system. Studies of the adhesion of RRP to other polymers suggest that adhesion between RRP and other dental polymers is possible to obtain by certain surface treatments.
Assessment of hydrochemical quality of ground water under some urban areas within sana'a secreteriat
Resumo:
Groundwater from nine wells of three different districts, located at Sana'a secretariat was analyzed for hydrochemical quality assessment. Measurements of water quality parameters including pH, EC, CO3(2-), HCO3-, Cl-, NO3-, SO4(2-), Ca2+, Mg2+, Fe3+, K+, and Na+ were carried out . Classification of the groundwater samples according to Cl, SO4(2-), CO3(2-) and HCO3-, hardness (H), total dissolved solids (TDS), base-exchange, and meteoric genesis was demonstrated. Suitability of ground water samples for irrigation and industrial uses according to sodium adsorption ration (SAR), ratio of dissolved sodium (RDS), residual sodium carbonate (RSC) and saturation index (SI) was also investigated. The results of this study showed that almost all ground water samples were of good quality that makes them suitable for drinking and domestic uses. Results also indicated that even though some of the ground water samples were suitable for irrigation purposes, almost all of them were found not be good for industrial uses. Despite all drawbacks of the sewerage system built around Sana'a secretariat at the beginning of the first decade of the third millennium, the results of this study indicate that there is scope of significant improvement in Sana'a secretariat ground water quality.
Resumo:
Termites are well -known for their capacity to damage and destroy wood and wood products of all kinds in the tropics and subtropics. A field test was undertaken to evaluate variations in wood consumption of Pinus sp. and three species of Eucalyptus by subterranean termites. The test consisted of wooden stakes of each species being initially submitted to water immersion for 0, 24, 48 and 72 h, and buried in the ground to natural infestation by subterranean termites for an exposure period of 30, 45 and 60 days. Three species of subterranean termites were identified: Heterotermes longiceps (Snyder), Coptotermes gestroi (Wasmann) (Isoptera: Rhinotermitidae), and Nasutitermes jaraguae (Holmgren) (Isoptera: Termitidae). This is the first record of occurrence of H. longiceps in the state of Rio de Janeiro. Although the wood-consumption rates were not correlated significantly with their wood densities, there was a tendency of the softwoods (E. robusta and Pinus sp.) to be more consumed by subterranean termites than the woods of intermediate hardness (E. pellita and E. urophylla). Among the eucalyptus, E. robusta showed to be more susceptible to attack by subterranean termites than E. pellita and E. urophylla