938 resultados para Interference screw


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper investigates which of Shannon’s measures (entropy, conditional entropy, mutual information) is the right one for the task of quantifying information flow in a programming language. We examine earlier relevant contributions from Denning, McLean and Gray and we propose and motivate a specific quantitative definition of information flow. We prove results relating equivalence relations, interference of program variables, independence of random variables and the flow of confidential information. Finally, we show how, in our setting, Shannon’s Perfect Secrecy theorem provides a sufficient condition to determine whether a program leaks confidential information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A field trial was carried out in Brazil in March 2002 with the aim to evaluate the effects of different timing and extension of weedy period on maize productivity. The hybrid Pioneer 30K75 was sowed under 7 t ha(-1) mulching promoted by glyphosate spraying. The treatments were divided in two groups: In the first group, weeds were maintained since the maize sowing until different periods in the crop cycle: 0, 14, 28, 42, 56, 70, and 150 days (harvesting time). In the second group, the maize crop was kept weed free for the same periods of the first group. Weed control was done through hand hoeing. A complete randomized blocks experimental design with five replications was used for plots distribution in the field. Nonlinear regression model was used to study the effects of weedy or weedfree periods on maize productivity. Weed community included 13 families and 31 species. Asteraceae, Poaceae, and Euphorbiaceae were the most abundant families. Results showed that under no tillage condition with 7 t ha-1 mulching at sowing time, the maize crop could cohabit with weed community for 54 days without any yield lost. on the other hand, if the crop was kept weed free for 27 days, the weed interference was not enable to reduce maize production. According to these results one weed control measure between 27 and 54 days after crop emergence could be enough to avoid any reduction in maize productivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work was carried out to study the effects of mineral nutrition on peanut (Arachis hypogaea L) cv. IAC Runner-886 and hairy beggarticks (Bidens pilosa L) growth, when submitted to inter- and intraspecific competition. The treatments consisted of two peanut plants per pot, two hairy beggarticks per pot and one plant of each species per pot. The plants were nourished with Hoagland and Arnon (1950) complete solution, or without potassium, or without phosphorus or without nitrogen. Sixty days after planting, no inter- or intraspecific competition effect on growth characteristics of peanut was verified and nutrition was not a limiting factor to the culture. No interaction between competition and nutrition effects was observed for both species. The weed suffered more negative effects from intraspecific competition and nutrition. The absence of N had a pronounced effect compared to the other elements, resulting in a reduction in all the evaluated characteristics. The deficiency of nutrients and competition affected the weed more than the crop, showing that peanut was more competitive than hairy beggarticks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivou-se com este trabalho determinar o período de convivência anterior à interferência das plantas daninhas (PAI) e o período anterior ao dano no rendimento econômico (PADRE) na cultura do feijão, em diferentes espaçamentos (0,45 e 0,60 m) e densidade de plantas (10 e 15 plantas m-1). Os tratamentos foram constituídos de períodos de convivência entre a cultura e as plantas daninhas (0 a 10, 0 a 20, 0 a 30, 0 a 40, 0 a 50, 0 a 60, 0 a 70 e 0 a 80 dias), mais uma testemunha sem convívio com as plantas daninhas. Adotou-se o delineamento experimental de blocos casualizados, com quatro repetições. Os períodos anteriores à interferência (PAI) da cultura foram de 23, 27, 13 e 19 dias após emergência, e os períodos anteriores ao dano no rendimento econômico (PADRE), de 10, 9, 8 e 8 dias, para os tratamentos com espaçamento de 0,45 m e densidades de semeadura de 10 e 15 plantas m-1 e para aqueles com espaçamento de 0,60 m e densidades de semeadura de 10 e 15 plantas m-1, respectivamente, o que reduziu a produtividade de grãos em 63, 50, 42 e 57%, respectivamente, com a presença das plantas daninhas durante todo o ciclo do feijoeiro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the universal conductance fluctuations (UCF) due to quantum interface in a two-dimensional electron gas (2DEG) grown on the substrates with pre-patterned, sub-micron wires. The dependence of UCF on the angle between the direction of the magnetic field and the substrate has been investigated. We found, that magnetoresistance traces for different angles are completely uncorrelated. A non-planar character of electron motion is responsible for these angular conductance fluctuations. We compared the experimental results with a simple geometrical model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From the beginning of the AIDS epidemic, pneumocystis pneumonia ( PCP) has been distinguished as one of the most frequent opportunistic diseases with high morbid-mortality. As from 1996, the advent of the highly active antiretroviral therapy ( HAART) has changed the characteristics of such epidemic by reducing its related diseases and, as a result, AIDS-related mortality. With the purpose to estimate PCP occurrence and HAART interference, 376 HIV-infected or AIDS patients were studied from January 1992 to December 2002. Among them, 58 ( 15.5%) PCP cases were found. There was a higher occurrence of PCP in the group of patients in which HAART was not used, with 40 ( 69.0%) of the episodes. As regards the studied period, a tendency to a linear reduction in annual PCP incidence was observed. The mean of T CD4+ lymphocytes in the patients with PCP ( 117 cells/mm(3)) was significantly lower when compared to that of the other individuals ( 325 cells/mm(3)). Therefore, this study suggests a temporal reduction in PCP occurrence related to HAART use with higher T CD4+ lymphocyte counts. Nevertheless, this opportunistic infection still shows significant incidence in AIDS patients. ( NCT00516581).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The misfit between prostheses and implants is a clinical reality, but the level that can be accepted without causing mechanical or biologic problem is not well defined. This study investigates the effect of different levels of unilateral angular misfit prostheses in the prosthesis/implant/retaining screw system and in the surrounding bone using finite element analysis. Four models of a two-dimensional finite element were constructed: group I (control), prosthesis that fit the implant; groups 2 to 4, prostheses with unilateral angular misfit of 50, 100, and 200 mu m, respectively. A load of 133 N was applied with a 30-degree angulation and off-axis at 2 mm from the long axis of the implant at the opposite direction of misfit on the models. Taking into account the increase of the angular misfit, the stress maps showed a gradual increase of prosthesis stress and uniform stress in the implant and trabecular bone. Concerning the displacement, an inclination of the system due to loading and misfit was observed. The decrease of the unilateral contact between prosthesis and implant leads to the displacement of the entire system, and distribution and magnitude alterations of the stress also occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Materials and Methods: Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 x 10(6) cycles was defined. Group means were calculated and compared using analysis of variance and the F test (alpha=.05). Results: Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P=.021). After cyclic loading, there was no significant difference between them (P=.499). Conclusions: Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1061-1067

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cimetidine, referred as antiandrogenic agent, has caused alterations in the seminiferous tubules, including alterations in the peritubular tissue and death of myoid cells by apoptosis. Regarding the structural and functional importance of the peritubular tissue for the maintenance of Sertoli cells (SC), we purpose to investigate the SC-basement membrane interface, focusing the morphological features of SC and their interaction with the basement membrane in the affected tubules by cimetidine. Ten animals were distributed into two groups, control (CG) and cimetidine (CmG) which received saline solution and 50 mg of cimetidine per kg of body weight, respectively, for 52 days. The testes were fixed, dehydrated and embedded for analyses under light and transmission electron microscopy. Paraffin sections were submitted to the TUNEL method; sections of testes embedded in glycol methacrylate were submitted to PAS method and stained by H&E for morphological and quantitative analyses of Sertoli Cells. In the CmG, the SC nuclei were positive to the TUNEL method and showed typical morphological alterations of cell death by apoptosis (from early to advanced stages). A significant reduction in the number of Sertoli Cells was probably due to death of these cells by apoptosis. A close relationship between SC nuclear alterations (including a high frequency of dislocated nuclei from the basal portion) and damage in the peritubular tissue was observed. The ultrastructural analysis showed a parallelism between the gradual advancement of apoptotic process in SC and detachment of the anchoring sites (hemidesmosomes) of SC plasma membrane from the lamina densa. The presence of portions of lamina densa underlying the detached hemidesmosomes indicates a continuous deposition of lamina densa, resulting in the thickening of the basal lamina. The results indicate a possible disarrangement of the SC cytoskeleton, including the focal adhesion structure. These alterations are related to SC apoptosis and probably result from disturbs induced by cimetidine on the peritubular tissue.