971 resultados para Industry Efficiency
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright 2013 Springer Netherlands.
Resumo:
In the present paper we analyzed the behavior of firms in the construction and manufacturing sectors, located in the region of Vale do Sousa, in the north of Portugal. From the literature, even existing some disagreements, it is possible to conclude that planning is crucial for firms survival and growth. Cooperation is another aspect that the literature presents as an important factor for firms sustainability. It also plays a major role in competition, since firms are adopting coopetition strategies. By studying a sample of 251 firms, it was possible to realize, that the majority started their business without a formal planning, and they keep going without using it. In cooperation aspects, there is a lack of cooperation. It was possible to verify, that existing cooperation has some evidence but at a vertical level. These vertical relations were also identified in stakeholder’s involvement.
Resumo:
Cork processing wastewater is a very complex mixture of vegetal extracts and has, among other natural compounds, a very high content of phenolic/tannic colloidal matter that is responsible for severe environmental problems. In the present work, the concentration of this wastewater by nanofiltration was investigated with the aim of producing a cork tannin concentrate to be utilized in tanning. Permeation results showed that the permeate fluxes are controlled by both osmotic pressure and fouling/gel layer phenomena, leading to a rapid decrease of permeate fluxes with the concentration factor. The rejection coefficients to organic matter were higher than 95%, indicating that nanofiltration has a very good ability to concentrate the tannins and produce a permeate stream depleted from organic matter. The cork tannin concentrate obtained by nanofiltration and evaporation had total solids concentration of 34.8 g/l. The skins tanned by this concentrate were effectively converted to leather with a shrinking temperature of 7 degrees C.
Resumo:
Wastewater from cork processing industry present high levels of organic and phenolic compounds, such as tannins, with a low biodegradability and a significant toxicity. These compounds are not readily removed by conventional municipal wastewater treatment, which is largely based on primary sedimentation followed by biological treatment. The purpose of this work is to study the biodegradability of different cork wastewater fractions, obtained through membrane separation, in order to assess its potential for biological treatment and having in view its valorisation through tannins recovery, which could be applied in other industries. Various ultrafiltration and nanofiltration membranes where used, with molecular weight cut-offs (MWCO) ranging from 0.125 to 91 kDa. The wastewater and the different permeated fractions were analyzed in terms of Total Organic Carbon (TOC), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Total Phenols (TP), Tannins, Color, pH and Conductivity. Results for the wastewater shown that it is characterized by a high organic content (670.5-1056.8 mg TOC/L, 2285-2604 mg COD/L, 1000-1225 mg BOD/L), a relatively low biodegradability (0.35-0.38 for BODs/COD and 0.44-0.47 for BOD20/COD) and a high content of phenols (360-410 mg tannic acid/L) and tannins (250-270 mg tannic acid/L). The results for the wastewater fractions shown a general decrease on the pollutant content of permeates, and an increase of its biodegradability, with the decrease of the membrane MWCO applied. Particularly, the permeated fraction from the membrane MWCO of 3.8 kDa, presented a favourable index of biodegradability (0.8) and a minimized phenols toxicity that enables it to undergo a biological treatment and so, to be treated in a municipal wastewater treatment plant. Also, within the perspective of valorisation, the rejected fraction obtained through this membrane MWCO may have a significant potential for tannins recovery. Permeated fractions from membranes with MWCO lower than 3.8 kDa, presented a particularly significant decline of organic matter and phenols, enabling this permeates to be reused in the cork processing and so, representing an interesting perspective of zero discharge for the cork industry, with evident environmental and economic advantages. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Cork processing involves a boiling step to make the cork softer, which consumes a high volume of water and generates a wastewater with a high organic content, rich in tannins. An assessment of the final wastewater characteristics and of the boiling water composition along the boiling process was performed. The parameters studied were pH, color, total organic carbon (TOC), chemical and biochemical oxygen demands (COD, BOD5, BOD20), total suspended solids (TSS), total phenols and tannins (TP, TT). It was observed that the water solutes extraction power is significantly reduced for higher quantities of cork processed. Valid relationships between parameters were established not only envisaging wastewater characterization but also to provide an important tool for wastewater monitoring and for process control/optimization. Boiling water biodegradability presented decreasing values with the increase of cork processed and for the final wastewater its value is always lower than 0.5, indicating that these wastewaters are very difficult to treat by biological processes. The biodegradability was associated with the increase of tannin content that can rise up to 0.7 g/L. These compounds can be used by other industries when concentrated and the clarified wastewater can be reused, which is a potential asset in this wastewater treatment.
Resumo:
Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia
Resumo:
Dissertação de Mestrado, Gestão de Empresa (MBA), 16 de Julho de 2013, Universidade dos Açores.
Resumo:
Espresso spent coffee grounds were chemically characterized to predict their potential, as a source of bioactive compounds, by comparison with the ones from the soluble coffee industry. Sampling included a total of 50 samples from 14 trademarks, collected in several coffee shops and prepared with distinct coffee machines. A high compositional variability was verified, particularly with regard to such water-soluble components as caffeine, total chlorogenic acids (CGA), and minerals, supported by strong positive correlations with total soluble solids retained. This is a direct consequence of the reduced extraction efficiency during espresso coffee preparation, leaving a significant pool of bioactivity retained in the extracted grounds. Besides the lipid (12.5%) and nitrogen (2.3%) contents, similar to those of industrial coffee residues, the CGA content (478.9 mg/100 g), for its antioxidant capacity, and its caffeine content (452.6 mg/100 g), due to its extensive use in the food and pharmaceutical industries, justify the selective assembly of this residue for subsequent use.
Resumo:
The BALA project (Biodiversity of Arthropods of Laurisilva of the Azores) is a research initiative to quantify the spatial distribution of arthropod biodiversity in native forests of the Azores archipelago. Arthropods were collected using a combination of two techniques, targeting epigean (ground dwelling) and canopy (arboreal) arthropods: pitfall traps (with Turquin and Ethylene solutions) and beating samples (using the three most dominant plant species). A total of 109 transects distributed amongst 18 forest fragments in seven of the nine Azorean islands were used in this study. The performance of alternative sampling methods and effort were tested. No significant differences were found in the accumulated number of species captured whether an alternative method was used or whether another transect with similar effort was established in another location within the same fragment. A combination of Ethylene and Turquin traps captured more species per individual, Turquin and beating captured more species per sample, and Turquin captured more species per unit time. An optimization exercise was performed and we found that the protocol applied during recent years is very close to optimal, allowing its future replication with confidence. The minimum combinations of sampling effort and methods, in order to monitor or to inventory diversity, taking into account different proportions of sample completeness are discussed.
Resumo:
OBJECTIVE: The Integrated Management of Childhood Illness is a strategy designed to address major causes of child mortality. The aim of this study was to assess the impact of the strategy on the quality of child health care provided at primary facilities. METHODS: Child health quality of care and costs were compared in four states in Northeastern Brazil, in 2001. There were studied 48 health facilities considered to have had stable strategy implementation at least two years before the start of study, with 48 matched comparison facilities in the same states. A single measure of correct management of sick children was used to assess care provided to all sick children. Costs included all resources at the national, state, local and facility levels associated with child health care. RESULTS: Facilities providing strategy-based care had significantly better management of sick children at no additional cost to municipalities relative to the comparison municipalities. At strategy facilities 72% of children were correctly managed compared with 56% in comparison facilities (p=0.001). The cost per child managed correctly was US$13.20 versus US$21.05 in the strategy and comparison municipalities, respectively, after standardization for population size. CONCLUSIONS: The strategy improves the efficiency of primary facilities in Northeastern Brazil. It leads to better health outcomes at no extra cost.
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
O presente trabalho insere-se no âmbito do Mestrado de Engenharia Química, ramo Optimização Energética na Indústria Química e pretende-se efectuar a avaliação energética do Complexo Municipal de Piscinas de Folgosa, localizado no Concelho da Maia, tendo como principais bases os Decretos-Lei 78, 79 e 80 de 04 de Abril 2006. Uma vez que a área útil de pavimento do presente edifício é superior a 1000 m2, encontra-se englobado no conceito de Grande Edifício de Serviços (GES). A escolha do Complexo Municipal de Piscinas de Folgosa para a realização do presente estudo prendeu-se com o facto de ser um objectivo da Câmara Municipal, mais concretamente do Departamento de Conservação e Manutenção de Estruturas Municipais, dar inicio aos procedimentos necessários para a certificação energética dos diversos edifícios Municipais, aliado ao facto das piscinas serem um tipo de edifício desportivo de elevada complexidade em termos de gestão, um grande consumidor de energia e possuidor de uma elevada diversidade de equipamentos. O objectivo principal será o de caracterizar energeticamente o edifício e optimizar os consumos do mesmo, de forma a reduzir, não só os consumos energéticos e respectiva factura, mas também nas emissões dos gases de efeito de estufa (CO2), pelo que a ordem de trabalhos inclui a realização de: - Avaliação Energética de acordo com o n.º1 do artigo 2º e artigo 34º do D. L. 79/2006; - Verificação dos Requisitos de Condução e manutenção das instalações de Aquecimento, Ventilação e Ar Condicionado (AVAC); - Caracterização Energética do Edifício – Índice de Eficiência Energética. A metodologia seguida baseou-se na utilizada para a realização de uma auditoria energética, sendo que foram contempladas as seguintes etapas: estudo pormenorizado da legislação referente à certificação de edifícios; realização de um levantamento de consumos energéticos reais da instalação (com base nas facturas energéticas); das suas características funcionais e levantamento dos vários equipamentos consumidores de energia. O Complexo Municipal de Piscinas de Folgosa é uma instalação cuja média de consumo de energia eléctrica nos últimos três anos foi de 445969 kWh/ano e de 87300 m3 de gás natural, representando um consumo global de energia primária de 174,85 tep/ano. De acordo com o Sistema de Certificação Energética o Índice de Eficiência Energética determinado é de 54,50 kgep/m2 .ano. Uma vez que o IEE determinado é superior ao valor de IEEReferência existentes, o edifício estará obrigado ao cumprimento de um Plano de Racionalização Energética (PRE). É apresentado um conjunto de medidas que visam uma redução do consumo de energia do edifício e consequentemente uma melhoria no Índice de Eficiência Energética.