893 resultados para Hearning and visual problem


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the differences between the Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: Eighty nine eyes of 46 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter / 500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter / 695nm barrier filter) before and after FFA. The quality of the FAF images was estimated, compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo- and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior quality in 18 eyes, while Topcon images were estimated superior in 21 eyes. No difference was found in 50 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found to strongly increase the likelihood of better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (71%), but showed mild autofluorescence on Topcon (88%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 52% Iso-FAF, in 43% mild Hypo-FAF, and in 5% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to exudation showed better on HRA. Pigment epithelium detachment showed identical FAF behaviour on the border, but reduced FAF with Topcon in the center. Cystic edema was visible only on HRA in a petaloid pattern. Hard exsudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blocage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract or poor fixation. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behaviour, there are differences between the two systems which need to be taken into account when interpreting the images.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE We have previously shown that retinal stem cells (RSCs) can be isolated from the radial glia population of the newborn mouse retina (Angénieux et al., 2006). These RSCs have a great capacity to renew and to generate a large number of neurons including cells differentiated towards the photoreceptor lineage (Mehri-Soussi et al., 2006). However, recent published results from our lab revealed that such cells have a poor integration and survival rate after grafting. The uncontrolled environment of a retina seems to prevent good integration and survival after grafting in vivo. To bypass this problem, we are evaluating the possibility of generating in vitro a hemi-retinal tissue before transplantation. METHODS RSC were expanded and cells passaged <10 were seeded in a solution containing poly-ethylene-glycol (PEG) polymer based hydrogels crosslinked with peptides that are chosen to be substrates for matrix metalloproteinases. Various doses of cross linkers peptides allowing connections between PEG polymers were tested. Different growth factors were studied to stimulate cell proliferation and differentiation. RESULTS Cells survived only in the presence of EGF and FGF-2 and generated colonies with a sphere shape. No cells migrated within the gel. To improve the migration and the repartition of the cells in the gels, the integrin ligand RGDSP was added into the gel. In the presence of FGF-2 and EGF, newly formed cell clusters appeared by cell proliferation within several days, but again no outspreading of cells was observed. No difference was even seen when the stiffness of the hydrogels or the concentration of the integrin ligand RGDSP were changed. However, our preliminary results show that RSCs still form spheres when laminin is entrapped in the gel, but they started to spread out having a neuronal morphology after around 2 weeks. The neuronal population was assessed by the presence of the neuronal marker b-tubulin-III. This differentiation was achieved after successive steps of stimulations including FGF-2 and EGF, and then only FGF-2. Glial cells were also present. Further characterizations are under process. CONCLUSIONS RSC can be grown in 3D. Preliminary results show that neuronal cell phenotype acquisition can be instructed by exogenous stimulations and factors linked to the gel. Further developments are necessary to form a homogenous tissue containing retinal cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Previous cross-sectional studies report that cognitive impairment is associated with poor psychosocial functioning in euthymic bipolar patients. There is a lack of long-term studies to determine the course of cognitive impairment and its impact on functional outcome. Method A total of 54 subjects were assessed at baseline and 6 years later; 28 had DSM-IV TR bipolar I or II disorder (recruited, at baseline, from a Lithium Clinic Program) and 26 were healthy matched controls. They were all assessed with a cognitive battery tapping into the main cognitive domains (executive function, attention, processing speed, verbal memory and visual memory) twice over a 6-year follow-up period. All patients were euthymic (Hamilton Rating Scale for Depression score lower than 8 and Young mania rating scale score lower than 6) for at least 3 months before both evaluations. At the end of follow-up, psychosocial functioning was also evaluated by means of the Functioning Assessment Short Test. RESULTS: Repeated-measures multivariate analysis of covariance showed that there were main effects of group in the executive domain, in the inhibition domain, in the processing speed domain, and in the verbal memory domain (p<0.04). Among the clinical factors, only longer illness duration was significantly related to slow processing (p=0.01), whereas strong relationships were observed between impoverished cognition along time and poorer psychosocial functioning (p<0.05). CONCLUSIONS: Executive functioning, inhibition, processing speed and verbal memory were impaired in euthymic bipolar out-patients. Although cognitive deficits remained stable on average throughout the follow-up, they had enduring negative effects on psychosocial adaptation of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Dizziness is a common symptom which is frequently due to either peripheral or central vestibular dysfunction. However, some patients may lack typical signs suggesting a vestibular or cerebellar lesion and they mostly complain of vertigo or posture imbalance induced by visual stimulation. The symptoms immediately improve either on cessation of the visual input or upon closure of the eyes. Such a presentation is typical of visual vertigo. PATIENTS AND METHODS: From 1993 to 2003, 242 patients were examined for either "vertigo" or "dizziness". The diagnosis of visual vertigo was based on both history and clinical examination and was present in 11 patients. RESULTS: Visual vertigo was diagnosed in 11/242 patients (4.5 %). Age range was 31 - 77 years (mean 47 years) with a sex ratio of 8 females for 3 males. Neuro-ophthalmological examination was normal in all cases. CONCLUSIONS: Visual vertigo is not a rare condition but the disease is underdiagnosed. The symptoms result from a mismatch between vestibular, proprioceptive and visual inputs. Neuro-ophthalmological, neurological and neuro-otological examination are often normal or not relevant and the diagnosis is largely based on history. It is important to recognize this entity because the symptoms might improve if the patients are treated with psycho-motor rehabilitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared the pupil responses originating from outer versus inner retinal photoreception between patients with isolated hereditary optic neuropathy (HON, n = 8) and healthy controls (n = 8). Three different testing protocols were used. For the first two protocols, a response function of the maximal pupil contraction versus stimulus light intensity was generated and the intensity at which half of the maximal pupil contraction, the half-max intensity, was determined. For the third protocol, the pupil size after light offset, the re-dilation rate and re-dilation amplitude were calculated to assess the post-light stimulus response. Patients with HON had bilateral, symmetric optic atrophy and significant reduction of visual acuity and visual field compared to controls. There were no significant mean differences in the response curve and pupil response parameters that reflect mainly rod, cone or melanopsin activity between patients and controls. In patients, there was a significant correlation between the half-max intensity of the red light sequence and visual field loss. In conclusion, pupil responses derived from outer or inner retinal photoreception in HON patients having mild-to moderate visual dysfunction are not quantitatively different from age-matched controls. However, an association between the degree of visual field loss and the half-max intensity of the cone response suggests that more advanced stages of disease may lead to impaired pupil light reflexes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reaching a consensus in terms of interchangeability and utility (i.e., disease detection/monitoring) of a medical device is the eventual aim of repeatability and agreement studies. The aim of the tolerance and relative utility indices described in this report is to provide a methodology to compare change in clinical measurement noise between different populations (repeatability) or measurement methods (agreement), so as to highlight problematic areas. No longitudinal data are required to calculate these indices. Both indices establish a metric of least to most effected across all parameters to facilitate comparison. If validated, these indices may prove useful tools when combining reports and forming the consensus required in the validation process for software updates and new medical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To define the phenotypic manifestation, confirm the genetic basis, and delineate the pathogenic mechanisms underlying an oculoauricular syndrome (OAS). METHODS: Two individuals from a consanguineous family underwent comprehensive clinical phenotyping and electrodiagnostic testing (EDT). Genome-wide microarray analysis and Sanger sequencing of the candidate gene were used to identify the likely causal variant. Protein modelling, Western blotting, and dual luciferase assays were used to assess the pathogenic effect of the variant in vitro. RESULTS: Complex developmental ocular abnormalities of congenital cataract, anterior segment dysgenesis, iris coloboma, early-onset retinal dystrophy, and abnormal external ear cartilage presented in the affected family members. Genetic analyses identified a homozygous c.650A>C; p.(Gln217Pro) missense mutation within the highly conserved homeodomain of the H6 family homeobox 1 (HMX1) gene. Protein modelling predicts that the variant may have a detrimental effect on protein folding and/or stability. In vitro analyses were able to demonstrate that the mutation has no effect on protein expression but adversely alters function. CONCLUSIONS: Oculoauricular syndrome is an autosomal recessive condition that has a profound effect on the development of the external ear, anterior segment, and retina, leading to significant visual loss at an early age. This study has delineated the phenotype and confirmed HMX1 as the gene causative of OAS, enabling the description of only the second family with the condition. HMX1 is a key player in ocular development, possibly in both the pathway responsible for lens and retina development, and via the gene network integral to optic fissure closure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nonverbal behavior coding is typically conducted by "hand". To remedy this time and resource intensive undertaking, we illustrate how nonverbal social sensing, defined as the automated recording and extracting of nonverbal behavior via ubiquitous social sensing platforms, can be achieved. More precisely, we show how and what kind of nonverbal cues can be extracted and to what extent automated extracted nonverbal cues can be validly obtained with an illustrative research example. In a job interview, the applicant's vocal and visual nonverbal immediacy behavior was automatically sensed and extracted. Results show that the applicant's nonverbal behavior can be validly extracted. Moreover, both visual and vocal applicant nonverbal behavior predict recruiter hiring decision, which is in line with previous findings on manually coded applicant nonverbal behavior. Finally, applicant average turn duration, tempo variation, and gazing best predict recruiter hiring decision. Results and implications of such a nonverbal social sensing for future research are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Understanding the basis on which recruiters form hirability impressions for a job applicant is a key issue in organizational psychology and can be addressed as a social computing problem. We approach the problem from a face-to-face, nonverbal perspective where behavioral feature extraction and inference are automated. This paper presents a computational framework for the automatic prediction of hirability. To this end, we collected an audio-visual dataset of real job interviews where candidates were applying for a marketing job. We automatically extracted audio and visual behavioral cues related to both the applicant and the interviewer. We then evaluated several regression methods for the prediction of hirability scores and showed the feasibility of conducting such a task, with ridge regression explaining 36.2% of the variance. Feature groups were analyzed, and two main groups of behavioral cues were predictive of hirability: applicant audio features and interviewer visual cues, showing the predictive validity of cues related not only to the applicant, but also to the interviewer. As a last step, we analyzed the predictive validity of psychometric questionnaires often used in the personnel selection process, and found that these questionnaires were unable to predict hirability, suggesting that hirability impressions were formed based on the interaction during the interview rather than on questionnaire data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Client change talk has been proposed as a mechanism of change in motivational interviewing (MI) by mediating the link between therapist MI-consistent behaviors (MICO) and client behavioral outcomes. We tested under what circumstances this mechanism was supported in the context of a clinical trial of brief MI for heavy drinking among nontreatment seeking young men. METHOD: We conducted psycholinguistic coding of 174 sessions using the MI Skill Code 2.1 and derived the frequency of MICO and the strength of change talk (CTS) averaged over the session. CTS was examined as a mediator of the relationship between MICO and a drinking composite score measured at 3-month follow-up, controlling for the composite measure at baseline. Finally, we tested therapist gender and MI experience as well as client readiness to change and alcohol problem severity as moderators of this mediation model. RESULTS: CTS significantly predicted outcome (higher strength related to less drinking), but MICO did not predict CTS. However, CTS mediated the relationship between MICO and drinking outcomes when therapists had more experience in MI and when clients had more severe alcohol problems (i.e., significant conditional indirect effects). CONCLUSIONS: The mechanism hypothesized by MI theory was operative in our brief MI with heavy drinking young men, but only under particular conditions. Our results suggest that attention should be paid to therapist selection, training, and/or supervision until they reach a certain level of competence, and that MI might not be appropriate for nontreatment seeking clients drinking at a lower level of risk. (PsycINFO Database Record

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: This study aims to identify which aspects of the pupil light reflex are most influenced by rods and cones independently by analyzing pupil recordings from different mouse models of photoreceptor deficiency. METHODS: One-month-old wild type (WT), rodless (Rho-/-), coneless (Cnga3-/-), or photoreceptor less (Cnga3-/-; Rho-/- or Gnat1-/-) mice were subjected to brief red and blue light stimuli of increasing intensity. To describe the initial dynamic response to light, the maximal pupillary constriction amplitudes and the derivative curve of the first 3 seconds were determined. To estimate the postillumination phase, the constriction amplitude at 9.5 seconds after light termination was related to the maximal constriction amplitude. RESULTS: Rho-/- mice showed decreased constriction amplitude but more prolonged pupilloconstriction to all blue and red light stimuli compared to wild type mice. Cnga3-/- mice had constriction amplitudes similar to WT however following maximal constriction, the early and rapid dilation to low intensity blue light was decreased. To high intensity blue light, the Cnga3-/- mice demonstrated marked prolongation of the pupillary constriction. Cnga3-/-; Rho-/- mice had no pupil response to red light of low and medium intensity. CONCLUSIONS: From specific gene defective mouse models which selectively voided the rod or cone function, we determined that mouse rod photoreceptors are highly contributing to the pupil response to blue light stimuli but also to low and medium red stimuli. We also observed that cone cells mainly drive the partial rapid dilation of the initial response to low blue light stimuli. Thus photoreceptor dysfunction can be derived from chromatic pupillometry in mouse models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of this study was to examine the changes in the prevalence, incidence, and characteristics of headache in childhood and adolescence. In addition, the predictors of the change in the occurrence of childhood headache and the association between adolescent headache and behavior were studied. The occurrence and characteristics of headache were investigated as part of a prospective follow-up study, where 6-year-old children and their families (n=1132) were followed to the age of 12-years (n=1126). The study design entailed both a cohort and case-control group. The incidence of headache and the association between headache and behavior were studied in another cohort, consisting of 11-year-old twins (n=5393), who were followed to the age of 17 (n=4159). The prevalence rates of headache increased during the follow-up, especially in boys whose mothers suffered from frequent headache. The incidence rates of frequent headache changed the most in girls between ages of 11 and 14. Early-onset migraine and tension-type headache were equal predictors of migraine at age 12. The age-related changes observed in pain localization, concurrent symptoms and triggers were considerable. Headache frequency was significantly associated with externalizing and internalizing problem behaviors and adaptive behaviors as rated by parents, but only with externalizing problem behaviors as rated by teachers. Headache both in children and adolescents is characterized by its changing nature. Its prevention and treatment should take familial, environmental and psychosocial aspects into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sensor-based robot control allows manipulation in dynamic environments with uncertainties. Vision is a versatile low-cost sensory modality, but low sample rate, high sensor delay and uncertain measurements limit its usability, especially in strongly dynamic environments. Force is a complementary sensory modality allowing accurate measurements of local object shape when a tooltip is in contact with the object. In multimodal sensor fusion, several sensors measuring different modalities are combined to give a more accurate estimate of the environment. As force and vision are fundamentally different sensory modalities not sharing a common representation, combining the information from these sensors is not straightforward. In this thesis, methods for fusing proprioception, force and vision together are proposed. Making assumptions of object shape and modeling the uncertainties of the sensors, the measurements can be fused together in an extended Kalman filter. The fusion of force and visual measurements makes it possible to estimate the pose of a moving target with an end-effector mounted moving camera at high rate and accuracy. The proposed approach takes the latency of the vision system into account explicitly, to provide high sample rate estimates. The estimates also allow a smooth transition from vision-based motion control to force control. The velocity of the end-effector can be controlled by estimating the distance to the target by vision and determining the velocity profile giving rapid approach and minimal force overshoot. Experiments with a 5-degree-of-freedom parallel hydraulic manipulator and a 6-degree-of-freedom serial manipulator show that integration of several sensor modalities can increase the accuracy of the measurements significantly.