909 resultados para Gold atoms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel material for electrochemical biosensing based on rigid conducting gold nanocomposite (nano-AuGEC) is presented. Islands of chemisorbing material (gold nanoparticles) surrounded by nonreactive, rigid, and conducting graphite epoxy composite are thus achieved to avoid the stringent control of surface coverage parameters required during immobilization of thiolated oligos in continuous gold surfaces. The spatial resolution of the immobilized thiolated DNA was easily controlled by merely varying the percentage of gold nanoparticles in the composition of the composite. As low as 9 fmol (60 pM) of synthetic DNA were detected in hybridization experiments when using a thiolated probe. Moreover, for the first time a double tagging PCR strategy was performed with a thiolated primer for the detection of Salmonella sp., one of the most important foodborne pathogens affecting food safety. Ibis assay was performed by double-labeling the amplicon during the PCR with a -DIG and -SH set of labeled primers. The thiolated end allows the immobilization of the amplicon on the nano-AuGEC electrode, while digoxigenin allows the electrochemical detection with the antiDIG-HRP reporter in the femtomole range. Rigid conducting gold nanocomposite represents a good material for the improved and oriented immobilization of biomolecules with excellent transducing properties for the construction of a wide range of electrochemical biosensors such as immunosensors, genosensors, and enzymosensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 1980-1990 Amazonian gold rush left an enormous liability that increasingly has been substituted by developing fish aquaculture. This work aimed at the identification of the mercury levels in the environment, associated with fish farms located in the North of Mato Grosso State, Southern Amazon. Sediment and soil samples were analyzed for total organic carbon and total mercury. Results indicate that the chemical characteristics of the sediment largely depend on the management procedures of the fish pond (liming, fish food used and fish population). The soils presented relatively low concentrations when compared with other data from the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and inexpensive way to fabricate arrays of gold microelectrodes is proposed. Integrated circuit chips are sawed through their middle, normal to the longest axis, leading to destruction of the silicon circuit and rupture of the gold wires that interconnect it with the external terminals. Polishing the resulting rough surface converts the tips of the wires embedded in the chip halves into arrays of gold microdisks of about 25 mu m diameter. The number of active microelectrodes (MEs), of an array depends on the number of pins in the chip, n, being typically (n/2)-4. These MEs can be used individually or externally interconnected in any combination. X-ray images of the chips and micrographs of the resulting surface of the polished arrays have revealed variable distances between neighbor MEs, which are, however, larger than 10 times the radius of the disks. This feature of the MEs prevents diffusional cross-talk between electrodes. The use of these microdisk electrodes for analytical purposes exhibits sigmoidal voltammograms, and chronoamperometric experiments confirm the nonlinear i vs. t(1/2) plots, typical for processes where radial diffusion prevails. Satisfactory uniformity was observed for the response of each electrode of an array, indicating similarity of geometry and disk areas. The potentialities of these MEs were demonstrated by the determination of cadmium at ppb levels using square wave voltammetry with preconcentration. Due to the relative ease with which these MEs can be manufactured and their good performance in (chemical) analysis, wide applications in electrochemistry and electroanalysis is envisioned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We theoretically investigated how the formation of oxygen vacancies and the addition of niobium and chromium atoms as dopants modify the varistor properties of TiO2. The calculations were carried out at the HF level using a contracted basis set, developed by Huzinaga et al.. to represent the atomic centers on the (110) surface for the large (TiO2)(15) cluster model. The change of the values for the net atomic charges and band gap after oxygen vacancy formation and the presence of dopants in the lattice are analyzed and discussed. It is shown that the formation of oxygen vacancies decreases the band gap while an opposite effect is found when dopants are located in the reduced surface. The theoretical results are compared with available experimental data. A plausible explanation of the varistor behavior of this system is proposed. (C) 1997 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the total mercury determination in fish and shrimps employing chronopotentiometric stripping analysis on gold film electrodes is described. Fish and shrimp tissues were digested using a microwave oven equipped with closed vessels. We developed a microwave heating program which decomposed all the samples employing diluted nitric acid and hydrogen peroxide. The proposed method was validated by analyzing a certified reference material and then applied for different fish species from fresh water and seawater acquired in local markets of São Paulo city, Brazil. The Brazilian legislation establishes 0.5 and 1 mg per kilogram of fish as upper limit of mercury for omnivorous and predator species, respectively. Except for blue shark tissues, the mercury content was situated below 0.5 mu g g(-1) for all the analyzed samples. The detection limit of the proposed method was calculated as 5 ng g(-1) of sample utilizing 5 minutes of electrodeposition (+300 mV vs. Ag/AgCl) on the gold electrode. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we describe a versatile and very sensitive way for copper quantification by potentiometric stripping analysis using gold electrodes obtained from recordable compact disks (CDs). This new source of electrodes (CDtrodes) shown similar performance to the commercial gold electrodes with superior versatility and lower cost. Recordable CDs contains a highly pure gold film with thickness between 50 and 100 nm and superficial area of ca. 100 cm(2). The working electrode developed was used successfully in stationary cell and many experimental parameters have been optimized. For copper, the detection limit attained was 30 ng L-1 (600 s deposition time) with remarkable precision (standard deviation of 1.8 % for 20 repetitive measurements using 25 mu gL(-1) of copper with 60 s of deposition time). The gold electrode developed was used for analysis of copper in sugar cane spirits and tap water samples. The results were compared with those obtained by atomic absorption spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irreversible photoexpansion effect has been observed in amorphous Ga10Ge2S65 glasses when its surface was exposed to light with energy greater than the band gap, 3.52 eV. A volume change of about 5% was reached in bulk samples by controlling illumination time and the laser power density. To understand the atomic scale processes of the photoexpansion effect, extended X-ray absorption fine structure (EXAFS) spectroscopy has been used as a local probe of the germanium environment in the glass samples before and after illumination. Modifications are observed in the average coordination shell around Ge atoms in the illuminated sample compared to the non-illuminated one. For the non-illuminated sample, the Ge coordination shell is described by a distorted tetrahedron of sulfur atoms at around 2.20 Angstrom. After illumination, the EXAFS signal can be explained by introducing an additional contribution to this average environment. Based on an analysis of the EXAFS data we proposed a two-shell model of 0.5 oxygen atoms at 2.01 Angstrom and 3.6 sulfur atoms at a 2.20 Angstrom. The existence of Ge-O bonds in the glass after illumination was confirmed by infrared measurements. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and attractive method for quantification of ascorbic acid (AA) in beers, soda, natural juices and commercial vitamin C tablets was achieved by combining Bow injection analysis and amperometric detection. An array of gold microelectrodes electrochemically modified by deposition of palladium was employed as working electrode which was almost unaffected by fouling effects. Ascorbic acid was quantified in beverages and vitamin tablets using amperometric differential measurements. This method is based on three steps involving the flow injection of: 1) the sample plus a standard addition of AA, 2) the pure sample, and 3) the enzymatically-treated sample. The enzymatic treatment was carried out with Cucumis sativus tissue, which is a rich source of ascorbate oxidase, at pH 7. The calibration plots for freshly prepared ascorbic acid standards were very linear in the concentration range of 0.18-1.8 mg L-1 with a relative standard deviation (RSD) < 1%, while for real samples the deviations were between 2.7% to 8.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray absorption spectroscopy was used to study the local environment of tungsten atoms in NaPO3-BaF2,-WO3 glasses and the results were compared with crystalline references Na2WO4 and WO3. XANES measurements at the W-L-1 edge allowed to determine a distorted octahedral environment of tungsten atoms in these glasses similar to the local order of tungsten in monoclinic WO3. Extended X-ray absorption fine structure (EXAFS) has been used as a local probe to monitor the effect of WO3 concentration on the tungsten environment. Based on an analysis of the EXAFS data, we proposed a three-shell model of oxygen atoms around tungsten as in monoclinic WO3. With increasing WO3 concentration, it was found that R-2 decreases from 1.96 to 1.92 angstrom whereas R-3 increases from 2.07 to 2.12 angstrom. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elastic and inelastic scattering of positronium (Ps) by H, He, He(+) and H(2) have been studied using coupled-channel calculations with a regularised nonlocal model exchange potential. Suitability and reliability of the theoretical scheme have been demonstrated by studying scattering cross-sections in various systems and also by addressing critical dynamic features like binding and resonances of Ps to open-shell-atoms. Results are found to be in good agreement with Variational predictions and experimental observations. (C) 2000 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate a dilute mixture of bosons and spin-polarized fermions in one dimension. With an attractive Bose-Fermi scattering length the ground state is a self-bound droplet, i.e., a Bose-Fermi bright soliton where the Bose and Fermi clouds are superimposed. We find that the quantum fluctuations stabilize the Bose-Fermi soliton such that the one-dimensional bright soliton exists for any finite attractive Bose-Fermi scattering length. We study density profile and collective excitations of the atomic bright soliton showing that they depend on the bosonic regime involved: mean-field or Tonks-Girardeau.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors presents a clinical case treated with brachytherapy performed with special mold of gold-198 disc, with the purpose of evaluating the distribution of radiation dose, the viability of manufacturing the radioactivity prosthesis and its operational cost. In despite of being only one case, we can conclude that the prosthesis with gold-198 foils can be manufactured in acrylic with thickness thinner than those ones with cylinder of cesium-137, resulting lower operational costs, besides permitting better distribution of radiation dose on the lesion. (C) 1999 Elsevier B.V. Ltd. All rights reserved.