974 resultados para Gold Catalyst, Formaldehyde Oxidation, Indoor Air Pollution, Ceria Support, TEM Analysis
Resumo:
Many studies have attempted to evaluate the importance of airborne fungi in the development of invasive fungal infection, especially for immunocompromised hosts. Several kinds of instruments are available to quantitate fungal propagule levels in air. We compared the performance of the most frequently used air sampler, the Andersen sampler with six stages, with a portable one, the Reuter centrifugal sampler (RCS). A total of 84 samples were analyzed, 42 with each sampler. Twenty-eight different fungal genera were identified in samples analyzed with the Andersen instrument. In samples obtained with the RCS only seven different fungal genera were identified. The three most frequently isolated genera in samples analyzed with both devices were Penicillium, Aspergillus and Cladophialophora. In areas supplied with a high efficiency particulate air filter, fungal spore levels were usually lower when compared to areas without these filters. There was a significant correlation between total fungal propagule measurements taken with both devices on each sampling occasion (Pearson coefficient = 0.50). However, the Andersen device recovered a broader spectrum of fungi. We conclude that the RCS can be used for quantitative estimates of airborne microbiological concentrations. For qualitative studies, however, this device cannot be recommended.
Resumo:
Mit dieser Arbeit wurde die Selbstassemblierung von dia- und paramagnetischen Molekülen sowie Einzelmolekülmagneten auf Goldsubstraten und magnetisch strukturierten Substraten untersucht. Dazu wurden drei verschiedene Klassen an Phthalocyaninderivaten verwendet: Diamagnetische Subphthalocyanine, paramagnetische Phthalocyaninatometalle und Diphthalocyaninatolanthanidkomplexe. Alle synthetisierten Verbindungen sind peripher thioethersubstituiert. Die Alkylketten (a: n-C8H17, b: n-C12H25) vermitteln die Löslichkeit in vielen organischen Solventien und sorgen für eine geordnete Assemblierung auf einer Oberfläche, wobei die Bindung auf Gold hauptsächlich über die Schwefelatome stattfindet. Die aus Lösung abgeschiedenen selbstassemblierten Monolagen wurden mit XPS, NEXAFS-Spektroskopie und ToF-SIMS untersucht. Bei der Selbstassemblierung auf magnetisch strukturierten Substraten stehen die Moleküle unter dem Einfluss magnetischer Streufelder und binden bevorzugt nur in bestimmten Bereichen. Die gebildeten Submonolagen wurden zusätzlich mit X-PEEM untersucht. Die erstmals dargestellten Manganphthalocyanine [MnClPc(SR)8] 1 wurden ausgehend von MnCl2 erhalten. Hier fand bei der Aufarbeitung an Luft eine Oxidation zu Mangan(III) statt; +III ist die stabilste Oxidationsstufe von Mangan in Phthalocyaninen. Der Nachweis des axialen Chloridoliganden erfolgte mit Massenspektrometrie und FIR- sowie Raman-Spektroskopie. SQUID-Messungen haben gezeigt, dass die Komplexe 1 vier ungepaarte Elektronen haben. Bei den Subphthalocyaninen [BClSubpc(SR)6] 2 wurde der axiale Chloridoligand mit dem stäbchenförmigen Phenolderivat 29-H substituiert und die erfolgreiche Ligandensubstitution durch NMR- und IR-Spektroskopie sowie Massenspektrometrie an den Produkten [BSubpc(SR)6(29)] 30 belegt. Der Radikalcharakter der synthetisierten Terbiumkomplexe [Tb{Pc(SR)8}2] 3 wurde spektroskopisch nachgewiesen; SQUID-Messungen ergaben, dass es sich um Einzelmolekülmagnete mit einer Energiebarriere U des Doppelpotentialtopfs von 880 K oder 610 cm-1 bei 3a handelt. Zunächst wurden die SAMs der Komplexverbindungen 1, 2, 30 und 3 auf nicht magnetisch strukturierten Goldsubstraten untersucht. Die Manganphthalocyanine 1 bilden geordnete SAMs mit größtenteils flach liegenden Molekülen, wie die XPS-, NEXAFS- und ToF-SIMS-Analyse zeigte. Die Mehrzahl der Thioether-Einheiten ist auf Gold koordiniert und die Alkylketten zeigen ungeordnet von der Oberfläche weg. Bei der Adsorption findet eine Reduktion zu Mangan(II) statt und der axiale Chloridoligand wird abgespalten. Das beruht auf dem sog. Oberflächen-trans-Effekt. Im vorliegenden Fall übt die Metalloberfläche einen stärkeren trans-Effekt als der axiale Ligand aus, was bisher experimentell noch nicht beobachtet wurde. Die thioethersubstituierten Subphthalocyanine 2 und 30 sowie die Diphthalocyaninatoterbium-Komplexe 3 sind ebenfalls für SAMs geeignet. Ihre Monolagen wurden mit XPS und NEXAFS-Spektroskopie untersucht, und trotz einer gewissen Unordnung in den Filmen liegen die Moleküle jeweils im Wesentlichen flach auf der Goldoberfläche. Vermutlich sind bei diesen Systemen auch die Alkylketten größtenteils parallel zur Oberfläche orientiert. Im Gegensatz zu den Manganphthalocyaninen 1 tritt bei 2b, 30a, 30b und 3b neben der koordinativen Bindung der Schwefelatome auf Gold auch eine für Thioether nicht erwartete kovalente Au–S-Bindung auf, die durch C–S-Bindungsbruch unter Abspaltung der Alkylketten ermöglicht wird. Der Anteil, zu dem dieser Prozess stattfindet, scheint nicht mit der Molekülstruktur zu korrelieren. Selbstassemblierte Submonolagen auf magnetisch strukturierten Substraten wurden mit dem diamagnetischen Subphthalocyanin 2b hergestellt. Der Nachweis der Submonolagen war schwierig und gelang schließlich durch eine Kombination von ToF-SIMS, NEXAFS Imaging und X-PEEM. Die Analyse der ToF-SIMS-Daten zeigte, dass tatsächlich eine Modulation der Verteilung der Moleküle auf einem unterwärts magnetisch strukturierten Substrat eintritt. Mit X-PEEM konnte die magnetische Struktur der ferromagnetischen Schicht des Substrats direkt der Verteilung der adsorbierten Moleküle zugeordnet werden. Die Subphthalocyanine 2b adsorbieren nicht an den Domänengrenzen, sondern vermehrt dazwischen. Auf Substraten mit abwechselnd 6.5 und 3.5 µm breiten magnetischen Domänen binden die Moleküle bevorzugt in den Bereichen geringster magnetischer Streufeldgradienten, also den größeren Domänen. Solche Substrate wurden für die ToF-SIMS- und X-PEEM-Messungen verwendet. Bei größeren magnetischen Strukturen mit ca. 400 µm breiten Domänen, wie sie aufgrund der geringeren Ortsauflösung dieser Methode für NEXAFS Imaging eingesetzt wurden, binden die Moleküle dann in allen Domänen. Die diamagnetischen Moleküle werden nach dieser Interpretation aus dem inhomogenen Magnetfeld über der Probenoberfläche heraus gedrängt und verhalten sich analog makroskopischer Diamagnete. Die eindeutige Detektion der Moleküle auf den magnetisch strukturierten Substraten konnte bisher nur für die diamagnetischen Subphthalocyanine 2b erfolgen. Um die Interpretation ihres Verhaltens bei der Selbstassemblierung in einem inhomogenen Magnetfeld weiter voranzutreiben, wurde das Subphthalocyanin 37b dargestellt, welches ein stabiles organisches TEMPO-Radikal in seinem axialen Liganden enthält. Das paramagnetische Subphthalocyanin 37b sollte auf den magnetisch strukturierten Substraten in Regionen starker magnetischer Streufelder binden und damit das entgegengesetzte Verhalten zu den diamagnetischen Subphthalocyaninen 2b zeigen. Aus Zeitgründen konnte dieser Nachweis im Rahmen dieser Arbeit noch nicht erbracht werden.
Resumo:
How do resource booms affect human capital accumulation? We exploit time and spatial variation generated by the commodity boom across local governments in Peru to measure the effect of natural resources on human capital formation. We explore the effect of both mining production and tax revenues on test scores, finding a substantial and statistically significant effect for the latter. Transfers to local governments from mining tax revenues are linked to an increase in math test scores of around 0.23 standard deviations. We find that the hiring of permanent teachers as well as the increases in parental employment and improvements in health outcomes of adults and children are plausible mechanisms for such large effect on learning. These findings suggest that redistributive policies could facilitate the accumulation of human capital in resource abundant developing countries as a way to avoid the natural resources curse.
Resumo:
In recent years, some epidemiologic studies have attributed adverse effects of air pollutants on health not only to particles and sulfur dioxide but also to photochemical air pollutants (nitrogen dioxide and ozone). The effects are usually small, leading to some inconsistencies in the results of the studies. Furthermore, the different methodologic approaches of the studies used has made it difficult to derive generic conclusions. We provide here a quantitative summary of the short-term effects of photochemical air pollutants on mortality in seven Spanish cities involved in the EMECAM project, using generalized additive models from analyses of single and multiple pollutants. Nitrogen dioxide and ozone data were provided by seven EMECAM cities (Barcelona, Gijón, Huelva, Madrid, Oviedo, Seville, and Valencia). Mortality indicators included daily total mortality from all causes excluding external causes, daily cardiovascular mortality, and daily respiratory mortality. Individual estimates, obtained from city-specific generalized additive Poisson autoregressive models, were combined by means of fixed effects models and, if significant heterogeneity among local estimates was found, also by random effects models. Significant positive associations were found between daily mortality (all causes and cardiovascular) and NO2, once the rest of air pollutants were taken into account. A 10 μg/m3 increase in the 24-hr average 1-day NO2 level was associated with an increase in the daily number of deaths of 0.43% [95% confidence interval(CI), –0.003–0.86%] for all causes excluding external. In the case of significant relationships, relative risks for cause-specific mortality were nearly twice as much as that for total mortality for all the photochemical pollutants. Ozone was independently related only to cardiovascular daily mortality. No independent statistically significant relationship between photochemical air pollutants and respiratory mortality was found. The results in this study suggest that, given the present levels of photochemical pollutants, people living in Spanish cities are exposed to health risks derived from air pollution
Resumo:
Research shows that poor indoor air quality (IAQ) in school buildings can cause a reduction in the students’ performance assessed by short-term computer-based tests; whereas good air quality in classrooms can enhance children's concentration and also teachers’ productivity. Investigation of air quality in classrooms helps us to characterise pollutant levels and implement corrective measures. Outdoor pollution, ventilation equipment, furnishings, and human activities affect IAQ. In school classrooms, the occupancy density is high (1.8–2.4 m2/person) compared to offices (10 m2/person). Ventilation systems expend energy and there is a trend to save energy by reducing ventilation rates. We need to establish the minimum acceptable level of fresh air required for the health of the occupants. This paper describes a project, which will aim to investigate the effect of IAQ and ventilation rates on pupils’ performance and health using psychological tests. The aim is to recommend suitable ventilation rates for classrooms and examine the suitability of the air quality guidelines for classrooms. The air quality, ventilation rates and pupils’ performance in classrooms will be evaluated in parallel measurements. In addition, Visual Analogue Scales will be used to assess subjective perception of the classroom environment and SBS symptoms. Pupil performance will be measured with Computerised Assessment Tests (CAT), and Pen and Paper Performance Tasks while physical parameters of the classroom environment will be recorded using an advanced data logging system. A total number of 20 primary schools in the Reading area are expected to participate in the present investigation, and the pupils participating in this study will be within the age group of 9–11 years. On completion of the project, based on the overall data recommendations for suitable ventilation rates for schools will be formulated.
Resumo:
Research shows that poor indoor air quality in school buildings can cause a reduction in the students' performance assessed by short term computer based tests; whereas good air quality in classrooms can enhance children's concentration and also teachers' productivity. Investigation of air quality in classrooms helps us to characterise pollutant levels and implement corrective measures. Outdoor pollution, ventilation equipment, furnishings, and human activities affect indoor air quality. In school classrooms the occupancy density is high (1.8 to 2.4 m(2)/person) compared to offices (10 m(2) /person). Ventilation systems expend energy and there is a trend to save energy by reducing ventilation rates. We need to establish the minimum acceptable level of fresh air required for the health of the occupants. This paper describes a project which will aim to investigate the effect of indoor air quality and ventilation rates on pupils' performance and health using psychological tests. The aim is to recommend suitable ventilation rates for classrooms and examine the suitability of the air quality guidelines for classrooms.
Resumo:
Purpose – To evaluate the control strategy for a hybrid natural ventilation wind catchers and air-conditioning system and to assess the contribution of wind catchers to indoor air environments and energy savings if any. Design/methodology/approach – Most of the modeling techniques for assessing wind catchers performance are theoretical. Post-occupancy evaluation studies of buildings will provide an insight into the operation of these building components and help to inform facilities managers. A case study for POE was presented in this paper. Findings – The monitoring of the summer and winter month operations showed that the indoor air quality parameters were kept within the design target range. The design control strategy failed to record data regarding the operation, opening time and position of wind catchers system. Though the implemented control strategy was working effectively in monitoring the operation of mechanical ventilation systems, i.e. AHU, did not integrate the wind catchers with the mechanical ventilation system. Research limitations/implications – Owing to short-falls in the control strategy implemented in this project, it was found difficult to quantify and verify the contribution of the wind catchers to the internal conditions and, hence, energy savings. Practical implications – Controlling the operation of the wind catchers via the AHU will lead to isolation of the wind catchers in the event of malfunctioning of the AHU. Wind catchers will contribute to the ventilation of space, particularly in the summer months. Originality/value – This paper demonstrates the value of POE as indispensable tool for FM professionals. It further provides insight into the application of natural ventilation systems in building for healthier indoor environments at lower energy cost. The design of the control strategy for natural ventilation and air-conditioning should be considered at the design stage involving the FM personnel.
Resumo:
The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. II, Reading, UK, 2000. p. 1013-18; [13] Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.
Resumo:
Until recently, there has been little investigation concerning the poor indoor air quality (IAQ) in classrooms. Despite the evidence that the educational building systems in many of the UK institutions have significant defects that may degrade IAQ, systematic assessments of IAQ measurements has been rarely undertaken. When undertaking IAQ measurement, there is a difficult task of representing and characterizing the environment parameters. Although technologies exist to measure these parameters, direct measurements especially in a naturally ventilated spaces are often difficult. This paper presents a methodology for developing a method to characterize indoor environment flow parameters as well as the Carbon Dioxide (CO2) concentrations. Thus, CO2 concentration level can be influenced by the differences in the selection of sampling points and heights. However, because this research focuses on natural ventilation in classrooms, air exchange is provided mainly by air infiltration. It is hoped that the methodology developed and evaluated in this research can effectively simplify the process of estimating the parameters for a systematic assessment of IAQ measurements in a naturally ventilated classrooms.
Resumo:
Research shows that poor indoor air quality (IAQ) in school buildings can cause a reduction in the students' performance assessed by short-term computer-based tests: whereas good air quality in classrooms can enhance children's concentration and also teachers' productivity. Investigation of air quality in classrooms helps us to characterise pollutant levels and implement corrective measures. Outdoor pollution, ventilation equipment, furnishings, and human activities affect IAQ. In school classrooms, the occupancy density is high (1.8-2.4m(2)/person) compared to offices (10 m(2)/person). Ventilation systems expend energy and there is a trend to save energy by reducing ventilation rates. We need to establish the minimum acceptable level of fresh air required for the health of the occupants. This paper describes a project, which will aim to investigate the effect of IAQ and ventilation rates on pupils' performance and health using psychological tests. The aim is to recommend suitable ventilation rates for classrooms and examine the suitability of the air quality guidelines for classrooms. The air quality, ventilation rates and pupils' performance in classrooms will be evaluated in parallel measurements. In addition, Visual Analogue Scales will be used to assess subjective perception of the classroom environment and SBS symptoms. Pupil performance will be measured with Computerised Assessment Tests (CAT), and Pen and Paper Performance Tasks while physical parameters of the classroom environment will be recorded using an advanced data logging system. A total number of 20 primary schools in the Reading area are expected to participate in the present investigation, and the pupils participating in this study will be within the age group of 9-11 years. On completion of the project, based oil the overall data recommendations for suitable ventilation rates for schools will be formulated. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This article addresses the need for providing good standards of indoor air quality (IAQ) in buildings from the view point of health, well-being and productivity of building occupants. It briefly outlines the role of ventilation in achieving the required IAQ targets and discusses the performance of different types of ventilation systems in use. As a result of new energy efficiency directives and legislations in Europe and elsewhere, the ventilation energy component of HVAC systems has increased in relative terms and this article introduces a method for evaluating the performance air distribution systems that is based on ventilation and energy effectiveness. A range of ventilation systems are discussed, including mechanical and natural ventilation, and results for more recently developed mechanical air distribution systems are compared with conventional systems. The article provides an assessment and comparison of some of these systems with reference to ventilation performance and energy efficiency
Resumo:
Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive feature of the system is its full utilization of cooling capacity and freshness of outdoor air in the transition period of the year round. On the basis of the obtain of the dynamic cooling loads of the typical shopping malls in different four cities located in cold climates in China with the aid of DOE-2, the possibility of increasing the amount of outdoor air volume of CVAV system in the transition period instead of operating the water chillers was confirmed. Moreover, a new concept, Direct Outdoor Air Cooling Efficiency (DOACE), was defined as the ratio of cooling capacity of outdoor air to the water chiller, indicating the degree of outdoor air’s utilization. And the DOACE of the CVAV was calculated and compared with that of conventional all-air constant volume air-conditioning systems, the results showed that CVAV bear much more energy saving potential with the 10%~19% higher DOACE and it is a kind of energy efficient systems and can improve the indoor air quality as well.
Resumo:
This work investigated the personal exposure to indoor particulate matters using the intake fraction metric and provided a possible way to trace the particle inhaled from an indoor particle source. A turbulence model validated by the particle measurements in a room with underfloor air distribution (UFAD) system was used to predict the indoor particle concentrations. Inhalation intake fraction of indoor particles was defined and evaluated in two rooms equipped with the UFAD, i.e., the experimental room and a small office. According to the exposure characteristics and a typical respiratory rate, the intake fraction was determined in two rooms with a continuous and episodic (human cough) source of particles, respectively. The findings showed that the well-mixing assumption of indoor air failed to give an accurate estimation of inhalation exposure and the average concentration at return outlet or within the overall room could not relate well the intake fraction to the amount of particle emitted from an indoor source.
Resumo:
The recent literature proposes many variables as significant determinants of pollution. This paper gives an overview of this literature and asks which of these factors have an empirically robust impact on water and air pollution. We apply Extreme Bound Analysis (EBA) on a panel of up to 120 countries covering the period 1960–2001. We find supportive evidence of the existence of the environmental Kuznets curve for water pollution. Furthermore, mainly variables capturing the economic structure of a country affect air and water pollution.