980 resultados para Geometric nonlinearities
Resumo:
We review recent developments in quantum and classical soliton theory, leading to the possibility of observing both classical and quantum parametric solitons in higher-dimensional environments. In particular, we consider the theory of three bosonic fields interacting via both parametric (cubic) and quartic couplings. In the case of photonic fields in a nonlinear optical medium this corresponds to the process of sum frequency generation (via chi((2)) nonlinearity) modified by the chi((3)) nonlinearity. Potential applications include an ultrafast photonic AND-gate. The simplest quantum solitons or energy eigenstates (bound-state solutions) of the interacting field Hamiltonian are obtained exactly in three space dimensions. They have a point-like structure-even though the corresponding classical theory is nonsingular. We show that the solutions can be regularized with the imposition of a momentum cut-off on the nonlinear couplings. The case of three-dimensional matter-wave solitons in coupled atomic/molecular Bose-Einstein condensates is discussed.
Resumo:
The development of large-scale solid-stale fermentation (SSF) processes is hampered by the lack of simple tools for the design of SSF bioreactors. The use of semifundamental mathematical models to design and operate SSF bioreactors can be complex. In this work, dimensionless design factors are used to predict the effects of scale and of operational variables on the performance of rotating drum bioreactors. The dimensionless design factor (DDF) is a ratio of the rate of heat generation to the rate of heat removal at the time of peak heat production. It can be used to predict maximum temperatures reached within the substrate bed for given operational variables. Alternatively, given the maximum temperature that can be tolerated during the fermentation, it can be used to explore the combinations of operating variables that prevent that temperature from being exceeded. Comparison of the predictions of the DDF approach with literature data for operation of rotating drums suggests that the DDF is a useful tool. The DDF approach was used to explore the consequences of three scale-up strategies on the required air flow rates and maximum temperatures achieved in the substrate bed as the bioreactor size was increased on the basis of geometric similarity. The first of these strategies was to maintain the superficial flow rate of the process air through the drum constant. The second was to maintain the ratio of volumes of air per volume of bioreactor constant. The third strategy was to adjust the air flow rate with increase in scale in such a manner as to maintain constant the maximum temperature attained in the substrate bed during the fermentation. (C) 2000 John Wiley & Sons, Inc.
Resumo:
We consider the quantum theory of three fields interacting via parametric and repulsive quartic couplings. This can be applied to treat photonic chi((2)) and chi((3)) interactions, and interactions in atomic Bose-Einstein condensates or quantum Fermi gases, describing coherent molecule formation together with a-wave scattering. The simplest two-particle quantum solitons or bound-state solutions of the idealized Hamiltonian, without a momentum cutoff, are obtained exactly. They have a pointlike structure in two and three dimensions-even though the corresponding classical theory is nonsingular. We show that the solutions can be regularized with a momentum cutoff. The parametric quantum solitons have much more realistic length scales and binding energies than chi((3)) quantum solitons, and the resulting effects could potentially be experimentally tested in highly nonlinear optical parametric media or interacting matter-wave systems. N-particle quantum solitons and the ground state energy are analyzed using a variational approach. Applications to atomic/molecular Bose-Einstein condensates (BEC's) are given, where we predict the possibility of forming coupled BEC solitons in three space dimensions, and analyze superchemistry dynamics.
Resumo:
Kinematic analysis is conducted to derive the geometric constraints for the geometric design of foldable barrel vaults (FBV) composed of polar or angulated scissor units. Non-linear structural analysis is followed to determine the structural response of FBVs in the fully deployed configuration under static loading. Two load cases are considered: cross wind and longitudinal wind. The effect of varying member sizes, depth-to-span ratio and geometric imperfections is examined. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
In a primary analysis of a large recently completed randomized trial in 915 high-risk patients undergoing major abdominal surgery, we found no difference in outcome between patients receiving perioperative epidural analgesia and those receiving IV opioids, apart from the incidence of respiratory failure. Therefore, we performed a selected number of predetermined subgroup analyses to identify specific types of patients who may have derived benefit from epidural analgesia. We found no difference in outcome between epidural and control groups in subgroups at increased risk of respiratory or cardiac complications or undergoing aortic surgery, nor in a subgroup with failed epidural block (all P > 0.05). There was a small reduction in the duration of postoperative ventilation (geometric mean [SD]: control group, 0.3 [6.5] h, versus epidural group, 0.2 [4.8] h, P = 0.048). No differences were found in length of stay in intensive care or in the hospital. There was no relationship between frequency of use of epidural analgesia in routine practice outside the trial and benefit from epidural analgesia in the trial. We found no evidence that perioperative epidural analgesia significantly influences major morbidity or mortality after major abdominal surgery.
Resumo:
Affective learning, the learning of likes and dislikes, is proposed to differ from signal learning, the learning of relationships between events. However, affective learning research varies in the methodology used, and in addition, researchers concerned primarily with affective learning tend to use different paradigms from those concerned with signal learning. The current research used an affective priming task in addition to verbal ratings to assess changes in the valence of neutral geometric shapes in an aversive differential conditioning procedure. After acquisition, affective learning was present as indexed by ratings and affective priming, whereas after extinction, affective learning remained significant only in the ratings. This study suggests that different measures of affective learning may be differentially sensitive to valence, which has implications for studies that employ verbal ratings as the sole measure of affective learning. Moreover, there is no evidence from the current study that affective learning differs from signal learning.
Resumo:
This paper examines the hysteresis hypothesis in the Brazilian industrialized exports using a time series analysis. This hypothesis finds an empirical representation into the nonlinear adjustments of the exported quantity to relative price changes. Thus, the threshold cointegration analysis proposed by Balke and Fomby [Balke, N.S. and Fomby, T.B. Threshold Cointegration. International Economic Review, 1997; 38; 627-645.] was used for estimating models with asymmetric adjustment of the error correction term. Amongst sixteen industrial sectors selected, there was evidence of nonlinearities in the residuals of long-run relationships of supply or demand for exports in nine of them. These nonlinearities represent asymmetric and/or discontinuous responses of exports to different representative measures of real exchange rates, in addition to other components of long-run demand or supply equations. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fear relevance, the potential of a stimulus to become quickly associated with fear, is a characteristic assumed to have an evolutionary basis and to result in preferential processing. Previous research has shown that fear relevant stimuli share a number of characteristics, negative valence and preferential identification in a visual search task, for instance. The present research examined whether these two characteristics can be acquired by non-fear relevant stimuli (geometric shapes) as a result of Pavlovian fear conditioning. Two experiments employed an aversive learning paradigm with geometric shape CSs and a shock US, with stimulus ratings, affective priming and visual search performance assessed before and after acquisition and after extinction. Differential electrodermal responses, larger during CS1 than CS, were present during acquisition but not during extinction. Affective priming results suggest that the CS1 acquired negative valence during acquisition, which was lost during extinction. However, negative valence as indexed by more negative ratings for CS1 than for CS shapes seemed to survive extinction. Preferential attentional processing as indexed by faster detection of CS1 among CS shapes than vice versa on the visual search task also remained. The current research confirmed that characteristics of fear relevant stimuli can be acquired in an aversive learning episode and that they may be extinguished. This supports the proposal that fear relevance may be malleable through learning.
Resumo:
A series of aluminum-10 wt pet silicon castings were produced in sand molds to investigate the effect of modification on porosity formation. Modification with individual additions of either strontium or sodium resulted in a statistically significant increase in the level of porosity compared to unmodified castings. The increase in porosity with modification is due to the presence of numerous dispersed pores, which were absent in the unmodified casting. It is proposed that these pores form as a result of differences in size of the aluminum-silicon eutectic grains between unmodified and modified alloys. A geometric model is developed to show how the size of eutectic grains can influence the amount and distribution of porosity. Unlike traditional feeding-based models, which incorporate the effect: of microstructure on permeability, this model considers what happens when liquid is isolated from the riser and can no longer flow. This simple isolation model complements rather than contradicts existing theories on modification-related porosity formation and should be considered in the development of future comprehensive models.
Resumo:
The total deposition of environmental tobacco smoke (ETS), diesel and petrol smoke in the respiratory tract of 14 non-smokers between the ages of 20 and 30 was determined experimentally. A scanning mobility particle sizer (SMPS) measuring a size range of 0.016-0.626 mu m was used to characterise the inhaled and exhaled aerosol during relaxed nasal breathing over a period of 10 min. The ETS, diesel, and petrol particles had average count median diameter (and geometric standard deviation) of 0.183 mu m (1.7), 0.125 mu m (1.7), and 0.069 mu m (1.7), respectively. The average total number deposition of ETS was 36% (standard deviation 10%), of diesel smoke 30% (standard deviation 9%), and of petrol smoke 41% (standard deviation 8%). The analysis of the deposition patterns as a function of particle size for the three aerosols in each individual showed that there is a significant difference between each aerosol for a majority of individuals (12 out of 14). This is an important result as it indicates that differences persist regardless of inter-subject variability. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Real time three-dimensional echocardiography (RT3DE) has been demonstrated to be an accurate technique to quantify left ventricular (LV) volumes and function in different patient populations. We sought to determine the value of RT3DE for evaluating patients with hypertrophic cardiomyopathy (HCM), in comparison with cardiac magnetic resonance imaging (MRI). Methods: We studied 20 consecutive patients with HCM who underwent two-dimensional echocardiography (2DE), RT3DE, and MRI. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, ejection fraction (LVEF), mass, geometric index, and dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. Results: There was excellent agreement between 2DE and RT3DE (Rc = 0.92), 2DE and MRI (Rc = 0.85), and RT3DE and MRI (Rc = 0.90) for linear measurements. Agreement indexes for LV end-diastolic and end-systolic volumes were Rc = 0.91 and Rc = 0.91 between 2DE and RT3DE, Rc = 0.94 and Rc = 0.95 between RT3DE and MRI, and Rc = 0.89 and Rc = 0.88 between 2DE and MRI, respectively. Satisfactory agreement was observed between 2DE and RT3DE (Rc = 0.75), RT3DE and MRI (Rc = 0.83), and 2DE and MRI (Rc = 0.73) for determining LVEF, with a mild underestimation of LVEF by 2DE, and smaller variability between RT3DE and MRI. Regarding LV mass, excellent agreement was observed between RT3DE and MRI (Rc = 0.96), with bias of -6.3 g (limits of concordance = 42.22 to -54.73 g). Conclusion: In patients with HCM, RT3DE demonstrated superior performance than 2DE for the evaluation of myocardial hypertrophy, LV volumes, LVEF, and LV mass.
Resumo:
The intercalated discs of working myocardium and Purkinje fibers of the monkey heart were examined by scanning and transmission electron microscopy. The NaOH/ultrasonication technique resulted in the digestion of connective tissue and a separation of the intercellular junctions of intercalated discs, such that these could be visualized three-dimensionally. The intercalated discs of ventricular myocytes, atrial myocytes and Purkinje fibers vary considerably in number and configuration, as do the intercalated discs of the three different layers of the ventricular myocardium. Myocytes in the subepicardial, middle and subendocardial layers of the ventricle have 1-3, 4-5 and 5-6 intercalated discs at the end of these cells, respectively, Those in the endocardial layer are characterized by the presence of small laterally-placed intercalated discs. Atrial myocytes and Purkinje fibers usually only have 1-2 intercalated discs, Individual intercalated discs in ventricular myocytes have complicated stairs with 10-30 steps and corresponding risers, while those of atrial myocytes and Purkinje fibers have simple stairs with 1-3 steps and risers, Steps equivalent to the plicate segments are characterized by densely-packed microplicae and finger-like microprojections which greatly increase surface area in vertricular myocytes, Microprojections in atrial myocytes and Purkinje fibers are sparse by comparison, Risers equivalent to the interplicate segments containing large gap junctional areas are most numerous in left ventricular myocytes, followed by right ventricular myocytes, Purkinje fibers and atrial myocytes in decreasing order. The geometric arrangement of the various types of myocytes may be related with impulse propagation. Large intercalated discs of cell trunks and series branches may participate in longitudinal propagation, while small laterally-placed ones may be the site of transverse propagation.
Resumo:
Background Despite the WHO recommendation that the 2010-2011 trivalent seasonal flu vaccine must contain A/California/7/2009/H1N1-like virus there is no consistent data regarding its immunogenicity and safety in a large autoimmune rheumatic disease (ARD) population. Methods 1668 ARD patients (systemic lupus erythematosus (SLE), rheumatoid arthritis (RA), ankylosing spondylitis (AS), systemic sclerosis, psoriatic arthritis (PsA), Behcet`s disease (BD), mixed connective tissue disease, primary antiphospholipid syndrome (PAPS), dermatomyositis (DM), primary Sjogren`s syndrome, Takayasu`s arteritis, polymyositis and Granulomatosis with polyangiitis (Wegener`s) (GPA)) and 234 healthy controls were vaccinated with a non-adjuvanted influenza A/California/7/2009(H1N1) virus-like strain flu. Subjects were evaluated before vaccination and 21 days post-vaccination. The percentage of seroprotection, seroconversion and the factor increase in geometric mean titre (GMT) were calculated. Results After immunisation, seroprotection rates (68.5% vs 82.9% p < 0.0001), seroconversion rates (63.4% vs 76.9%, p < 0.001) and the factor increase in GMT (8.9 vs 13.2 p < 0.0001) were significantly lower in ARD than controls. Analysis of specific diseases revealed that seroprotection significantly reduced in SLE (p < 0.0001), RA (p < 0.0001), PsA (p=0.0006), AS (p=0.04), BD (p=0.04) and DM (p=0.04) patients than controls. The seroconversion rates in SLE (p < 0.0001), RA (p < 0.0001) and PsA (p=0.0006) patients and the increase in GMTs in SLE (p < 0.0001), RA (p < 0.0001) and PsA (p < 0.0001) patients were also reduced compared with controls. Moderate and severe side effects were not reported. Conclusions The novel recognition of a diverse vaccine immunogenicity profile in distinct ARDs supports the notion that a booster dose may be recommended for diseases with suboptimal immune responses. This large study also settles the issue of vaccine safety. (ClinicalTrials.gov #NCT01151644)
Resumo:
Simultaneous solitary wave solutions for laser propagation in nonlinear parametric media with up to (3 + 1) dimensions are proved to exist. The combination of the large dispersion of a Bragg grating and the strong nonlinearity of chi((2)) optical material results in stable behavior with short interaction distances and low power requirements. The solutions are obtained by using the effective mass approximation to reduce the coupled propagation equations to those describing a dispersive parametric nonlinear waveguide, and are verified by solving the complete set of coupled band-gap equations numerically.
Resumo:
Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010