966 resultados para Fuzzy Logic by the Extension Principle


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Component joining is typically performed by welding, fastening, or adhesive-bonding. For bonded aerospace applications, adhesives must withstand high-temperatures (200°C or above, depending on the application), which implies their mechanical characterization under identical conditions. The extended finite element method (XFEM) is an enhancement of the finite element method (FEM) that can be used for the strength prediction of bonded structures. This work proposes and validates damage laws for a thin layer of an epoxy adhesive at room temperature (RT), 100, 150, and 200°C using the XFEM. The fracture toughness (G Ic ) and maximum load ( ); in pure tensile loading were defined by testing double-cantilever beam (DCB) and bulk tensile specimens, respectively, which permitted building the damage laws for each temperature. The bulk test results revealed that decreased gradually with the temperature. On the other hand, the value of G Ic of the adhesive, extracted from the DCB data, was shown to be relatively insensitive to temperature up to the glass transition temperature (T g ), while above T g (at 200°C) a great reduction took place. The output of the DCB numerical simulations for the various temperatures showed a good agreement with the experimental results, which validated the obtained data for strength prediction of bonded joints in tension. By the obtained results, the XFEM proved to be an alternative for the accurate strength prediction of bonded structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the shear modulus and strength of the acrylic adhesive 3M® DP 8005 was evaluated by two different methods: the Thick Adherend Shear Test (TAST) and the Notched Plate Shear Method (Arcan). However, TAST standards advise the use of a special extensometer attached to the specimen, which requires a very experienced technician. In the present study, the adhesive shear displacement for the TAST was measured using an optical technique, and also with a conventional inductive extensometer of 25 mm used for tensile tests. This allowed for an assessment of suitability of using a conventional extensometer to measure this parameter. Since the results obtained by the two techniques are identical, it can be concluded that using a conventional extensometer is a valid option to obtain the shear modulus for the particular adhesive used. In the Arcan tests, the adhesive shear displacement was only measured using the optical technique. This work also aimed the comparison of shear modulus and strength obtained by the TAST and Arcan test methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article aims to contribute to the discussion of long-term dependence, focusing on the behavior of the main Belgian stock index. Non-parametric analyzes of the general characteristics of temporal frequency show that daily returns are non-ergodic and non-stationary. Therefore, we use the rescaled-range analysis (R/S) and the detrended fluctuation analysis (DFA), under the fractional Brownian motion approach, and we found slight evidence of long-term dependence. These results refute the random walk hypothesis with i.i.d. increments, which is the basis of the EMH in its weak form, and call into question some theoretical modeling of asset pricing. Other more localized complementary study, to identify the evolution of the degree of dependence over time windows, showed that the index has become less persistent from 2010. This may mean a maturing market by the extension of the effects of current financial crisis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The acquisition of a Myocardial Perfusion image (MPI) is of great importance for the diagnosis of the coronary artery disease, since it allows to evaluate which areas of the heart aren’t being properly perfused, in rest and stress situations. This exam is greatly influenced by photon attenuation which creates image artifacts and affects quantification. The acquisition of a Computerized Tomography (CT) image makes it possible to get an atomic images which can be used to perform high-quality attenuation corrections of the radiopharmaceutical distribution, in the MPI image. Studies show that by using hybrid imaging to perform diagnosis of the coronary artery disease, there is an increase on the specificity when evaluating the perfusion of the right coronary artery (RCA). Using an iterative algorithm with a resolution recovery software for the reconstruction, which balances the image quality, the administered activity and the scanning time, we aim to evaluate the influence of attenuation correction on the MPI image and the outcome in perfusion quantification and imaging quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mutagenic activities of 16 anti-parasite drugs were screened by the Simultest in both qualitative (spot test) and quantitative (plate incorporation) assays with a Salmonella typhimurium pool composed by the indicator strains TA97, TA 98, TA100 and TA102. Four anti Chagas' disease drugs (nifurtimox, benznidazole, CL 64,855, and MK 436) and two anti-amebae drugs (metronidazole and tinidazole) gave positive results in qualitative tests and incorporation of rat liver microsomes did not alter the results. Comparative dose response curves of the mutagenic activities of CL 64,855, metronidazole and benznidazole obtained by the simultest and by individual Salmonella indicator strains demonstrated that both approachs have similar sensitivities. The results corroborate the validity of the Simultest, as a simplified, fast and economic version of the Ames test in preliminary screening of potential mutagenic drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research is part of a larger project focused on producing a History of the Popularization of Science and Technology in Portugal. The goal is to find out how scientific knowledge reached the common people in the nineteenth century, using newspapers as the main source of information. Keeping in mind the population’s limited access to written material, nevertheless each newspaper could be read daily by an estimate 30.000 people in Lisbon, which places this source as probably the most widespread vehicle to divulge the latest scientific news at the time to an unspecialised audience. With a cholera morbus epidemic which affected the second largest Portuguese town and all the northern regions, as well as the Algarve, news and reports on its evolution were considered essential. A large database was built in order to analyse the news concerning this disease in 1855 and 1856, especially the ones about prevention and treatment. These are important historical sources that give us real information on the scientific knowledge of the time and the way it was used by society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detection of HBV-DNA by PCR was compared with other serological markers (HBsAg, HBeAg and anti-HBe) in a series of49 Chronic Hepatitis B patients, including 12 with a spontaneous clearance of HBsAg. None of these HBsAg negative cases were PCR positive, but 33/37 (89.2%) HBsAg positive cases were PCR positive (p < 0.0001). Among HBsAg positive samples, nine cases were HBeAg positive and anti-HBe negative, all of them PCR positive. Other 3 patients were HBeAg and anti-HBe positive and these cases were also found PCR positive. A third group included 21 patients anti-HBe positive and HBeAg negative: 19 of them were PCR positive and 2 were PCR negative. The last 4 cases were HBeAg and anti-HBe negative, two of them were PCR positive. The detection of anti-HBe viremic cases in the present series suggest that preC variants could occur in our country. In conclusion, the integrated phase o f chronic hepatitis B seems to be less frequent than it was assumed, when only HBeAg or dot blot hybridization techniques were used. The new term "low replication phase" might favorably replace the former "integrated phase".

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Here in is described the clinical and laboratorial findings of a laboratory-acquired infection caused by the virus SP H 114202 (Arenavirus, family Arenaviridae) a recently discovered agent responsible for a viral hemorrhagic fever. The patient was sick for 13 days. The disease had an abrupt onset characterized by high fever (39ºC.), headache, chills and myalgias for 8 days. In addition, on the 3rd day, the patient developed nauseas and vomiting, and in the 10th, epigastralgia, diarrheia and gengivorrhagia. Leucopenia was seen within the 1 st week of onset, with counts as low as 2,500 white cells per mm³. Counts performed after the 23th day of the onset were within normal limits. With the exception of moderate lymphocitosis, no changes were observed in differential counts. An increase in the liter of antibodies by complement fixation, neutralization and ELISA (IgM) was detected. Suckling mice and baby hamsters were inoculated intracerebrally with 0.02 ml of blood samples collected in the 2nd and 7th days of disease. Attempts to isolate the virus were also made in Vero cells. No virus was isolated. This virus was isolated before in a single occasion in São Paulo State, in 1990, from the blood of a patient with hemorrhagic fever with a fatal outcome. The manipulation of the virus under study, must be done carefully, since the transmission can occur through aerosols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) for the detection of circulating antigens from toxic components of Tityus serrulatus scorpion venom was determined in patients stung by T. serrulatus before antivenom administration. Thirty-seven patients were classified as mild cases and 19 as moderate or severe cases. The control absorbance in the venom assay was provided by serum samples from 100 individuals of same socioeconomic group and geographical area who had never been stung by scorpions or treated with horse antisera. The negative cutoff value (mean + 2 SD) corresponded to a venom concentration of 4.8 ng/ml. Three out of the 100 normal sera were positive, resulting in a specificity of 97%. The sensitivity of the ELISA when all cases of scorpion sting were included was 39.3%. When mild cases were excluded, the sensitivity increased to 94.7%. This study showed that this ELISA can be used for the detection of circulating venom toxic antigens in patients with systemic manifestations following. T. serrulatus sting but cannot be used for clinical studies in mild cases of envenoming since the test does not discriminate mild cases from control patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have detected antibodies, in the sera of Chagas disease, Kala-azar and Mucocutaneous leishmaniasis patients, that bind multiple antigens shared between the three causative agents. The Chagas disease sera showed 98 to 100% positive results by ELISA when the Leishmania braziliensis and Leishmania chagasi antigens were used, respectively. The Kala-azar sera showed 100% positive results with Trypanosoma cruzi or L. braziliensis antigens by immunofluorescence assays. The antibodies in the sera of Mucocutaneous leishmaniasis patients showed 100% positive results by ELISA assays with T. cruzi or L. chagasi antigens. Furthermore, the direct agglutination of L. chagasi promastigotes showed that 95% of Kala-azar and 35% of Mucocutaneous leishmaniasis sera agglutinated the parasite in dilutions above 1:512. In contrast, 15% of Chagas sera agglutinated the parasite in dilutions 1:16 and below. Western blot analysis showed that the Chagas sera that formed at least 24 bands with the T. cruzi also formed 13 bands with the L. chagasi and 17 bands with the L. braziliensis. The Kala-azar sera that recognized at least 29 bands with the homologous antigen also formed 14 bands with the T. cruzi and 10 bands with the L. braziliensis antigens. Finally, the Mucocutaneous leishmaniasis sera that formed at least 17 bands with the homologous antigen also formed 10 bands with the T. cruzi and four bands with the L. chagasi antigens. These results indicate the presence of common antigenic determinants in several protozoal proteins and, therefore, explain the serologic cross-reactions reported here.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prevalence of Strongyloides stercoralis infection in three areas of Brazil was surveyed by a recently developed faecal culture method (an agar plate culture). The Strongyloides infection was confirmed in 11.3% of 432 subjects examined. The diagnostic efficacy of the agar plate culture was as high as 93.9% compared to only 28.5% and 26.5% by the Harada-Mori filter paper culture and faecal concentration methods, when faecal samples were examined simultaneously by these three methods. Among the 49 positive samples, about 60% were confirmed to be positive only by the agar plate culture. These results indicate that the agar plate culture is a sensitive new tool for the correct diagnosis of chronic Strongyloides infection.