916 resultados para Fluorescent conjugation
Resumo:
The use of fluorescence is a valuable and increasingly accessible means of probing the pharmacology and physiology of cells and their receptors. To date, the use of fluorescence-based methods for 5-HT3 receptor research has been quite limited and, although a variety of approaches have been described, these are broadly distributed throughout the literature. In this review we condense these findings into a single, accessible source of reference with the hope of promoting the use of these valuable molecular probes.
Resumo:
Neuropharmacology (Elsevier) Special Issue entitled "Fluorescent Tools in Neuropharmacology" includes ten contributions from key researchers in this field. These contributions comprise reviews and orginial research articles.
Resumo:
Conjugation of functional entities with a specific set of optical, mechanical or biological properties to DNA strands allows engineering of sophisticated DNA-containing architectures. Among various hybrid systems, DNA-grafted polymers occupy an important place in modern materials science. In this contribution we present the non-covalent synthesis and properties of DNA-grafted linear supramolecular polymers (SPs), which are assembled in a controllable manner from short chimeric DNA-pyrene oligomers. The synthetic oligomers consist of two parts: a 10 nucleotides long DNA chain and a covalently attached segment of variable number of phosphodiester-linked pyrenes. The temperature-dependent formation of DNA-grafted SPs is described by a nucleation-elongation mechanism. The high tendency of pyrenes to aggregate in water, leads to the rapid formation of SPs. The core of the assemblies consists of stacked pyrenes. They form a 1D platform, to which the DNA chains are attached. Combined spectroscopic and microscopic studies reveal that the major driving forces of the polymerization are π-stacking of pyrenes and hydrophobic interactions, and DNA pairing contributes to a lesser extent. AFM and TEM experiments demonstrate that the 1D SPs appear as elongated ribbons with a length of several hundred nanometers. They exhibit an apparent helical structure with a pitch-to-pitch distance of 50±15 nm. Since DNA pairing is a highly selective process, the ongoing studies are aimed to utilize DNA-grafted SPs for the programmable arrangement of functional entities. For example, the addition of non-modified complementary DNA strands to the DNA-grafted SPs leads to the cooperative formation of higher-order assemblies. Also, our experiments suggest that the fluorescent pyrene core of 1D ribbons serves as an efficient donor platform for energy transfer applications.
Resumo:
Conjugation of functional entities with a specific set of optical, mechanical or biological properties to DNA strands allows engineering of sophisticated DNA-containing architectures. Among various hybrid systems, DNA-grafted polymers occupy an important place in modern materials science. In this contribution we present the non-covalent synthesis and properties of DNA-grafted linear supramolecular polymers (SPs), which are assembled in a controllable manner from short chimeric DNA-pyrene oligomers. The synthetic oligomers consist of two parts: a 10 nucleotides long DNA chain and a covalently attached segment of variable number of phosphodiester-linked pyrenes. The temperature-dependent formation of DNA-grafted SPs is described by a nucleation-elongation mechanism. The high tendency of pyrenes to aggregate in water, leads to the rapid formation of SPs. The core of the assemblies consists of stacked pyrenes. They form a 1D platform, to which the DNA chains are attached. Combined spectroscopic and microscopic studies reveal that the major driving forces of the polymerization are π-stacking of pyrenes and hydrophobic interactions, and DNA pairing contributes to a lesser extent. AFM and TEM experiments demonstrate that the 1D SPs appear as elongated ribbons with a length of several hundred nanometers. They exhibit an apparent helical structure with a pitch-to-pitch distance of 50±15 nm. Since DNA pairing is a highly selective process, the ongoing studies are aimed to utilize DNA-grafted SPs for the programmable arrangement of functional entities. For example, the addition of non-modified complementary DNA strands to the DNA-grafted SPs leads to the cooperative formation of higher-order assemblies. Also, our experiments suggest that the fluorescent pyrene core of 1D ribbons serves as an efficient donor platform for energy transfer applications.
Resumo:
Protein-protein interactions are fundamental for most biological processes, such as the formation of cellular structures and enzymatic complexes or in signaling pathways. The identification and characterization of protein-protein interactions are therefore essential for understanding the mechanisms and regulation of biological systems. The organization and dynamics of the cytoskeleton, as well as its anchorage to specific sites in the plasma membrane and organelles, are regulated by the plakins. These structurally related proteins anchor different cytoskeletal networks to each other and/or to other cellular structures. The association of several plakins with intermediate filaments (IFs) is critical for maintenance of the cytoarchitecture. Pathogenic mutations in the genes encoding different plakins can lead to dramatic manifestations, occurring principally in the skin, striated muscle, and/or nervous system, due to cytoskeletal disorganization resulting in abnormal cell fragility. Nevertheless, it is still unclear how plakins bind to IFs, although some general rules are slowly emerging. We here describe in detail a recently developed protein-protein fluorescence binding assay, based on the production of recombinant proteins tagged with green fluorescent protein (GFP) and their use as fluid-phase fluorescent ligands on immobilized IF proteins. Using this method, we have been able to assess the ability of C-terminal regions of GFP-tagged plakin proteins to bind to distinct IF proteins and IF domains. This simple and sensitive technique, which is expected to facilitate further studies in this area, can also be potentially employed for any kind of protein-protein interaction studies.
Resumo:
Antibody-drug conjugates (ADCs) have emerged as a promising class of anticancer agents, combining the specificity of antibodies for tumor targeting and the destructive potential of highly potent drugs as payload. An essential component of these immunoconjugates is a bifunctional linker capable of reacting with the antibody and the payload to assemble a functional entity. Linker design is fundamental, as it must provide high stability in the circulation to prevent premature drug release, but be capable of releasing the active drug inside the target cell upon receptor-mediated endocytosis. Although ADCs have demonstrated an increased therapeutic window, compared to conventional chemotherapy in recent clinical trials, therapeutic success rates are still far from optimal. To explore other regimes of half-life variation and drug conjugation stoichiometries, it is necessary to investigate additional binding proteins which offer access to a wide range of formats, all with molecularly defined drug conjugation. Here, we delineate recent progress with site-specific and biorthogonal conjugation chemistries, and discuss alternative, biophysically more stable protein scaffolds like Designed Ankyrin Repeat Proteins (DARPins), which may provide such additional engineering opportunities for drug conjugates with improved pharmacological performance.
Resumo:
With the advent of the Universal Technical Standard for Solar Home Systems, procedures to test the compliance of SHS fluorescent lamps with the standard have been developed. Definition of the laboratory testing procedures is a necessary step in any lamp quality assurance procedure. Particular attention has been paid to test simplicity and to affordability, in order to facilitate local application of the testing procedures, for example by the organisations which carry out electrification programmes. The set of test procedures has been applied to a representative collection of 42 lamps from many different countries, directly acquired in the current photovoltaic rural electrification market. Tests apply to: lamp resistance under normal operating conditions; lamp reliability under extreme conditions; under abnormal conditions; and lamp luminosity. Results are discussed and some recommendations for updating the relevant standard are given. The selected technical standard, together with the proposed testing procedures, form the basis of a complete quality assurance tool that can be applied locally in normal electrical laboratories. Full testing of a lamp requires less than one month, which is very reasonable on the context of quality assurance programmes
Resumo:
This paper proposes a way to quantify the emissions of mercury (Hg) and CO2 associated with the manufacture and operation of compact fluorescent lamps with integrated ballasts (CFLis), as well as the economic cost of using them under different operating cycles. The main purpose of this paper is to find simple criteria for reducing the polluting emissions under consideration and the economic cost of CFLi to a minimum. A lifetime model is proposed that allows the emissions and costs to be described as a function of degradation from turning CFLi on and their continuous operation. An idealized model of a CFLi is defined that combines characteristics stated by different manufacturers. In addition, two CFLi models representing poor-quality products are analyzed. It was found that the emissions and costs per unit of time of operation of the CFLi depend linearly on the number of times per unit of time it is turned on and the time of continuous operation. The optimal conditions (lowest emissions and costs) depend on the place of manufacture, the place of operation and the quality of the components of the lamp/ballast. Finally, it was also found that for each lamp, there are intervals when it is turned off during which emissions of pollutants and costs are identical regardless of how often the lamp is turned on or the time it remains on. For CO2 emissions, the lamp must be off up to 5 minutes; for the cost, up to 7 minutes and for Hg emissions, up to 43 minutes. It is advisable not to turn on a CFLi sooner than 43 minutes from the last time it was turned off.