995 resultados para Flue gas equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas chromatographic-mass spectrometric method is presented which allows the simultaneous determination of the plasma concentrations of fluvoxamine and of the enantiomers of fluoxetine and norfluoxetine after derivatization with the chiral reagent, (S)-(-)-N-trifluoroacetylprolyl chloride. No interference was observed from endogenous compounds following the extraction of plasma samples from six different human subjects. The standard curves were linear over a working range of 10 to 750 ng/ml for racemic fluoxetine and norfluoxetine and of 50 to 500 ng/ml for fluvoxamine. Recoveries ranged from 50 to 66% for the three compounds. Intra- and inter-day coefficients of variation ranged from 4 to 10% for fluvoxamine and from 4 to 13% for fluoxetine and norfluoxetine. The limits of quantitation of the method were found to be 2 ng/ml for fluvoxamine and 1 ng/ml for the (R)- and (S)-enantiomers of fluoxetine and norfluoxetine, hence allowing its use for single dose pharmacokinetics. Finally, by using a steeper gradient of temperature, much shorter analysis times are obtained if one is interested in the concentrations of fluvoxamine alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the Iowa Department of Transportation's Equipment and Vehicle Purchase Report for Fiscal Year 2007 as required by Iowa Code section 307.47. The report is sorted by our accounting object codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Department’s 2007 Greenhouse Gas Inventory is a refinement of previous statewide inventories. It is a bottom-up inventory of two sectors – fossil fuel combustion at federally-recognized major sources of air pollution and fossil fuel combustion and ethanol fermentation at dry mill ethanol plants. This is the first bottomup greenhouse gas inventory conducted for Iowa and the first bottom-up greenhouse gas inventory of ethanol plants in the nation that the Department is aware of. In a bottom-up inventory, facility-specific activity data is used to calculate emissions. In a top-down inventory, aggregate activity data is used to calculate emissions. For example, this bottom-up inventory calculates greenhouse gas emissions from the fossil fuel combustion at each individual facility instead of using the total amount of fossil fuel combusted state-wide, which would be a top-down inventory method. The advantage to a bottom-up inventory is that the calculations are more accurate than a top-down inventory. However, because the two methods differ, the results from a bottom-up inventory are not directly comparable to a top-down inventory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas-filled microbubbles (MB) are a very promising alternative to the currently evaluated lipid- or polymer-based particulate Ag delivery systems. We recently demonstrated the ability of MB to deliver associated Ag to DC, to activate them and thereby induce both humoral and cellular immune responses. We now extended the characterization of MB as antigen-delivery system by appraising the efficiency of MB-associated ovalbumin (OVA-MB) at protecting mice against pathogen infection. Ultrasound-mediated imaging demonstrated that the administration of OVA via MB generates a depot at the injection site that lasts for several hours. We found that OVA-MB injected subcutaneously is far more effective at inducing specific Ab and T cell immunity than immunization with free OVA. Moreover, a covalent link between MB and OVA causes a stronger bias towards a Th1-type of immune response than adsorption of the Ag or its covalent link to liposomes of the same lipid composition. Finally, vaccination of mice with OVA-MB partially protects against a systemic infection with OVA-expressing Listeria monocytogenes. The vaccine induces specific effector CD8 T cell responses capable of decreasing more than 100 fold the bacterial load. MB thus represent a potent Ag delivery system for vaccination against intracellular infectious agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attached is the Equipment and Vehicle Purchase Report for Fiscal Year 2008 as required by Iowa Code section 307.47. The report is sorted by our accounting object codes. The object codes help you sort the equipment into general categories. The following list will help you understand the codes: Object Description 701 Self Propelled Vehicles 702 Road Equipment & Trailers 703 Large Office Furniture & Files 704 Shop Tools & Small Equipment 705 Engineer, Survey & Measuring Equipment 706 Copiers, Fax & Communication Equipment 707 Computers & Related Equipment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. However, hydrogen (H2) detection after a GC separation is only possible with a Thermal Conductivity Detector (TCD), a Helium Ionisation Detector (HID) or expensive Atomic Emission Detector (AED). Recently, indirect H2 detection by GC coupled to mass spectrometry (MS) was demonstrated but the mechanism of carrier gas protonation remained unclear. With electron impact as ionisation source of MS and helium (He) as GC carrier gas, H2 is not ionised according the expected Penning ionisation neither according to the Associative ionisation. Rearrangement ionisation (RI) was found to be the main channel for H2 and D2 ionisation under GC-MS conditions used in most of laboratories using GC-MS, leading to the formation of [He−H]+ and [He−D]+ ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitive and specific methods based on gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) for the determination of levels of citalopram, desmethylcitalopram and didesmethylcitalopram in the plasma of patients treated with citalopram are presented, as well as a GC-MS procedure for the assay of the citalopram propionic acid derivative. After addition of a separate internal standard for each drug, liquid-solvent extraction is used to separate the basic compounds from the acid compounds. The demethylated amines are derivatized with trifluoroacetic anhydride, and the acid metabolite with methyl iodide. GC-MS is performed in the electron impact mode, as mass spectrometry by the (positive-ion) chemical ionization mode (methane and ammonia) appeared to be unsuitable. The limits of quantification were 1 ng/ml for citalopram and desmethylcitalopram and 2 ng/ml for the other metabolites. The correlation coefficients for the calibration curves (range 10-500 ng/ml) were > or = 0.999 for all compounds, whether determined by GC or GC-MS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Resuscitated cardiac arrest (CA) patients typically receive therapeutic hypothermia, but arterial blood gases (ABGs) are often assessed after adjustment to 37°C (alpha-stat) instead of actual body temperature (pH-stat). We sought to compare alpha-stat and pH-stat assessment of Pao2 and Paco2 in such patients. MATERIALS AND METHODS: Using ABG data obtained during the first 24 hours of intensive care unit admission, we determined the impact of measured alpha vs calculated pH-stat on Pao2 and Paco2 on patient classification and outcomes for CA patients. RESULTS: We assessed 1013 ABGs from 120 CA patients with a median age of patients 66 years (interquartile range, 50-76). Median alpha-stat Pao2 changed from 122 (95-156) to 107 (82-143) mm Hg with pH-stat and median Paco2 from 39 (34-46) to 35 (30-41) mm Hg (both P < .001). Using the categories of hyperoxemia, normoxemia, and hypoxemia, pH-stat estimation of Pao2 reclassified approximately 20% of patients. Using the categories of hypercapnia, normocapnia, and hypocapnia, pH stat estimation of Paco2 reclassified approximately 40% of patients. The mortality of patients in different Pao2 and Paco2 categories was similar for pH-stat and alpha-stat. CONCLUSIONS: Using the pH-stat method, fewer resuscitated CA patients admitted to intensive care unit were classified as hyperoxemic or hypercapnic compared with alpha-stat. These findings suggest an impact of ABG assessment methodology on Pao2, Paco2, and patient classification but not on associated outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Els negocis relacionats amb les activitats de lleure i els esports d’aventura actualment es troben en expansió, buscant majoritàriament el contacte amb la natura. Les rutes a cavall formen part del gran ventall d’opcions, per aquesta qüestió s’ha pensat en construir un refugi utilitzat com a final d’etapa per a rutes a cavall. En la major part del territori, la presència de població humana es manifesta en pobles, viles i ciutats, les quals disposes d’aigua sanitària, corrent elèctric i sistema de clavegueram. Per altra banda en les urbanitzacions o cases aïllades poder gaudir d’aquests serveis suposa una inversió econòmica elevada, que implica la utilització de sistemes alternatius. En el present projecte s’ha triat un emplaçament on portar a terme el final d’etapa amb una sèrie de requisits a complir : bosc a les proximitats, disposar d’un o varis accessos per a vehicles (transport del material d’intendència), tranquil•litat, bones vistes, i cobertura de telèfon mòbil. S’han acceptat les següents limitacions : no disposar de xarxa pública d’electricitat ni d’aigua. I s’han dimensionat les instal•lacions per a un màxim de dotze persones i els seus respectius cavalls. El principal objectiu del projecte és el dimensionament de les necessitats elèctriques, d’aigua i d’aiguacalenta sanitària en condicions autònomes, i utilitzant energies renovables. La valoració de les possibles solucions per condicionar les instal•lacions, i oferir una resposta eficient per la demanda. No és un objectiu específic del treball la potabilització de l’aigua ni el tractament dels residus produïts. S’han aprofitat els diferents desnivells que presenta l’emplaçament triat a l’hora de distribuir les instal•lacions, i s’ha utilitzat un antic cobert de dos pisos ja existent. Com a residència s’ha triat un model de casa prefabricada de muntanya. Com a sistema de subministrament elèctric, s’instal•laran plaques solars fotovoltaiques i un generador de corrent com a sistema auxiliar. La captació d’aigua s’efectuarà a partir d’un pou que es troba en el terreny i de la recollida d el’aigua pluvial, instal•lant dipòsits d’emmagatzemament d’aigua segons les necessitats. S’utilitzarà un equip de cloració per potabilitzar l’aigua de consum utilitzada a la residència. En la producció d’aigua calenta sanitària s’utilitzaran plaques solars tèrmiques i una caldera instantània de gas propà com a suport. Per cuinar s’ha triat una cuina de gas propà i una barbacoa que s’instal•larà a l’exterior. S’instal•larà una llar de foc amb recuperador d’aire a la residència i una fosa sèptica amb un sistema d’infiltració per poder abocar les aigües provinents de la residència. Els fems dels cavalls podran ser utilitzats com adob pel terreny.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Hospital Punta de Europa en Algeciras (Cádiz), centro sanitario del Servicio Andaluz de Salud, desea optimizar la gestión de sus instalaciones de generación de energía térmica (vapor, agua caliente sanitaria y agua caliente de calefacción) y adecuarlas a la normativa vigente así como la sustitución de bajantes del edificio, para lo cual sacará a concurso público la licitación para la concesión de dominio público de dichas instalaciones. Para definir el alcance y condiciones de la citada concesión, el Hospital Punta de Europa (Algeciras) del Servicio Andaluz de Salud ha solicitado a Pedro Alonso Martín el estudio para la reforma y adecuación de las instalaciones productoras de energía térmica del citado Hospital. El objetivo principal de este trabajo es hacer un estudio, propuesta y valoración de las actuaciones necesarias para la reforma y mejora de la explotación de las instalaciones generadoras de energía térmica y de la red saneamiento interior del Hospital Punta de Europa de Algeciras (Cádiz). Las actuales instalaciones de generación térmica consumidoras de energía del hospital dentro del alcance de este Proyecto son: Generación de vapor (lavandería y esterilización). Producción de agua caliente sanitaria (ACS). Producción de agua caliente de calefacción. La mayoría de los equipos productores de energía datan del año 1975, por lo que en la mayoría de los casos se ha cumplido su plazo de amortización y periodo de vida útil. Se hace necesaria la instalación de gas natural, debido a que se tendrá que abastecer a todas las calderas de la central térmica. El diseño del sistema de producción de agua caliente sanitaria garantiza el máximo confort y economía del usuario, compatible con el máximo ahorro energético y la protección del medio ambiente, cubriendo las necesidades de agua caliente sanitaria mediante la combinación de un sistema de calderas a gas con los colectores solares.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attached is the Equipment and Vehicle Purchase Report for Fiscal Year 2009 as required by Iowa Code section 307.47. The report is sorted by Iowa Department of Transportation accounting object codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attached is the Equipment and Vehicle Purchase Report for Fiscal Year 2009 as required by Iowa Code section 307.47. The report is sorted by Iowa Department of Transportation accounting object codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.