840 resultados para FRACTURES
Resumo:
Background: This is the first report of involvement of Australian and New Zealand oral and maxillofacial surgeons in the management of isolated orbital floor blow-out fractures and was conducted to obtain comparisons with the results from a recent similar survey of British oral and maxillofacial surgeons. Methods: A questionnaire survey was sent to all 113 practising members of the Australian and New Zealand Association of Oral and Maxillofacial Surgeons in April 2002 with a second mailout 1 month later. Results: Sixty-nine per cent of the respondents were referred isolated orbital floor blow-out fractures for manage-ment, and just over half of these respondents estimated that 50% or more of the cases went to surgery. The materials most commonly used in orbital floor reconstruction were resorbable membrane for small defects and autologous bone for large defects. Conclusion: As in Britain, management of isolated orbital floor blow-out fractures comprises part of the surgical spectrum for many oral and maxillofacial surgeons in Australia and New Zealand. The management protocol was observed to be very similar between the two groups.
Resumo:
We investigated the effect of pneumatic pressure applied to the proximal musculature of the sheep foreleg on load at the site of a transverse osteotomy of the distal radius. The distal radii of 10 fresh sheep foreleg specimens were osteotomized and a pressure sensor was inserted between the two bone fragments. An inflatable cuff, connected to a second pressure sensor, was positioned around the proximal forelimb musculature and the leg then was immobilized in a plaster cast. The inflatable cuff was inflated and deflated repeatedly to various pressures. Measurements of the cuff pressure and corresponding change in pressure at the osteotomy site were recorded. The results indicated that application of pneumatic pressure to the proximal foreleg musculature produced a corresponding increase in load at the osteotomy site. For the cuff pressures tested (109.8-238.4 mm Hg), there was a linear correlation with the load at the osteotomy site with a gradient of 12 mm Hg/N. It is conceivable, based on the results of this study, that a technique could be developed to provide dynamic loading to accelerate fracture healing in the upper limb of humans.
Resumo:
Background: fall-related hip fractures are one of the most common causes of disability and mortality in older age. The study aimed to quantify the relationship between lifestyle behaviours and the risk of fall-related hip fracture in community-dwelling older people. The purpose was to contribute evidence for the promotion of healthy ageing as a population-based intervention for falls injury prevention. Methods: a case-control study was conducted with 387 participants, with a case-control ratio of 1:2. Incident cases of fall-related hip fracture in people aged 65 and over were recruited from six hospital sites in Brisbane, Australia, in 2003-04. Community-based controls, matched by age, sex and postcode, were recruited via electoral roll sampling. A questionnaire designed to assess lifestyle risk factors, identified as determinants of healthy ageing, was administered at face-to-face interviews. Results: behavioural factors which had a significant independent protective effect on the risk of hip fracture included never smoking [adjusted odds ratio (AOR): 0.33 (0.12-0.88)], moderate alcohol consumption in mid- and older age [AOR: 0.49 (0.25-0.95)], not losing weight between mid- and older age [AOR: 0.36 (0.20-0.65)], playing sport in older age [AOR: 0.49 (0.29-0.83)] and practising a greater number of preventive medical care [AOR: 0.54 (0.32-0.94)] and self-health behaviours [AOR: 0.56 (0.33-0.94)]. Conclusion: with universal exposures, clear associations and modifiable behavioural factors, this study has contributed evidence to reduce the major public health burden of fall-related hip fractures using readily implemented population-based healthy ageing strategies.
Resumo:
Pediatric musculoskeletal trauma accounts for most childhood injuries. The anatomy and physiology of the pediatric skeleton is unique as is its response to trauma. The pediatric skeleton has periods of rapid growth; therefore the effect of trauma to the musculoskeletal system may have significant long-term complications.
Resumo:
Introduction: Pelvic rami fractures in the elderly are associated with significant morbidity and mortality. Despite our rapidly aging population there is a paucity of literature dealing with fractures of the pelvic rami in this age group. The purpose of this study is report mortality rates following these injuries in the Eastern region of Newfoundland. Additionally, we aim to describe and quantify the important resultant morbidity in this vulnerable elderly population . Methods: A retrospective chart review was performed of all the pelvic fractures in individuals over the age of 60 between 2000 and 2005 in the Eastern Health region of Newfoundland and Labrador. From these patients, only those with the radiographic parameters consistent with low energy pattern pelvic ring injuries were included. Excluded from the study were those with concurrent fractures of the femur. Survival data, comorbidities, injury characteristics, hospital stay, ambulatory status, and place of residence were recorded from the chart. A surrogate control group was formulated from Statistics Canada survival data for use as a survival comparison group. Results: There were 80 fractures of the pelvis identified in patients over 60 years old from 2000-2005. Of these, 43 met our inclusion/exclusion criteria and were used in our analysis. The one and five year mortalities of these patients were 16.3% (95% CI; 7.80% to 30.3%) and 58.1% (95% CI; 43.3% to 71.6%), respectively. These were both significantly different from the point estimates from our constructed age and gender matched control group from the Statistics Canada data of 6.58% (one year mortality) and 31.3% (five year mortality). Morbidity was quantified by change in ambulatory status (independent, walker/cane assisted, wheelchair) and change in residential independence (independent, assisted living, nursing home). Post fracture, 36% of patients permanently required increased ambulatory aids and 21% of patients required a permanent increase in everyday level of care. Conclusion: This study suggests that there may be significantly increased mortality and morbidity following low energy pattern pelvic rami fractures in an elderly population compared to age and gender matched controls. In contrast to previous studies describing these injuries, there is greater homogeneity in this population with respect to age and mechanism of injury. This study generates several important hypotheses for future research and in particular highlights the need for larger prospective studies to identify factors predicting the highest risk for poor outcomes in this population.
Resumo:
Background: For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Methods: Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Findings: Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). Interpretation: These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible.
Resumo:
This study was performed to characterize evidence of potential unconformity-type U mineralizing fluids in drill core fractures from the Stewardson Lake prospect, in the Athabasca Basin, located in Northern Saskatchewan and Alberta, Canada. Fractures were visually classified into eight varieties. This classification scheme was improved with the use of mineralogical characterization through SEM (Scanning Electron Microscope) and XRD analyses of the fracture fills and resulted in the identification of various oxides, hydroxides, sulfides, and clays or clay-sized minerals. Fractures were tallied to a total of ten categories with some commonalities in color. The oxidative, reductive or mixed nature of the fluids interacting with each fracture was determined based on its fill mineralogy. The measured Pb isotopic signature of samples was used to distinguish fractures affected solely by fluids emanating from a U mineralization source, from those affected by mixed fluids. Anomalies in U and U-pathfinder elements detected in fractures assisted with attributing them to the secondary dispersion halo of potential mineralization. Three types of fracture functions (chimney, composite and drain) were defined based on their interpreted flow vector and history. A secondary dispersion halo boundary with a zone of dominance of infiltrating fluids was suggested for two boreholes. The control of fill mineralogy on fracture color was investigated and the indicative and non-indicative colors and minerals, with respect to a secondary dispersion halo, were formally described. The fracture colors and fills indicative of proximity to the basement host of the potential mineralization were also identified. In addition, three zones of interest were delineated in the boreholes with respect to their geochemical dynamics and their relationship to the potential mineralization: a shallow barren overburden zone, a dispersion and alteration zone at intermediate depth, and a second deeper zone of dispersion and alteration.
Resumo:
International audience
Resumo:
Electrical impedance tomography is applied to the problem of detecting, locating, and tracking fractures in ballistics gelatin. The hardware developed is intended to be physically robust and based on off-the-shelf hardware. Fractures were created in two separate ways: by shooting a .22 caliber bullet into the gelatin and by injecting saline solution into the gelatin. The .22 caliber bullet created an air gap, which was seen as an increase in resistivity. The saline solution created a fluid filled gap, which was seen as a decrease in resistivity. A double linear array was used to take data for each of the fracture mechanisms and a two dimensional cross section was inverted from the data. The results were validated by visually inspecting the samples during the fracture event. It was found that although there were reconstruction errors present, it was possible to reconstruct a representation of the resistive cross section. Simulations were performed to better understand the reconstructed cross-sections and to demonstrate the ability of a ring array, which was not experimentally tested.
Resumo:
Les méthodes d'opération permettant la stabilisation temporaire de fractures du fémur ont peu changé dans les dernières décennies. Ce mémoire illustre d'abord les différentes techniques chirurgicales présentement utilisées. Ces dernières sont principalement des outils manuels très simples. Un survol des recherches universitaires sur le sujet démontre que l'effort se porte principalement sur des manipulateurs robotisés complexes qui sont peu susceptibles d'être utilisés dans les salles d'opération à court terme. Avec l'aide de chirurgiens, il a été possible de connaître les besoins de ceux-ci en ce qui concerne la réduction et la stabilisation de fractures. Un appareil mécanique transparent à la radiographie a été conçu. Pour ce faire, plusieurs éléments de machine et mécanismes ont dû être développés en matériaux plastiques ou composites. L'appareil permet aux chirurgiens de déplacer un des fragments de l'os dans les six degrés de liberté puis de le maintenir stable. Un prototype a été fabriqué. Des essais avec un simulateur de fracture ont permis de récolter les commentaires de chirurgiens.
Resumo:
A prospective, consecutive series of 106 patients receiving endoscopic anterior scoliosis correction. The aim was to analyse changes in radiographic parameters and rib hump in the two years following surgery. Endoscopic anterior scoliosis correction is a level sparing approach, therefore it is important to assess the amount of decompensation which occurs after surgery. All patients received a single anterior rod and vertebral body screws using a standard compression technique. Cleared disc spaces were packed with either mulched femoral head allograft or rib head/iliac crest autograft. Radiographic parameters (major, instrumented, minor Cobb, T5-T12 kyphosis) and rib hump were measured at 2,6,12 and 24 months after surgery. Paired t-tests and Wilcoxon signed ranks tests were used to assess the statistical significant of changes between adjacent time intervals.----- Results: Mean loss of major curve correction from 2 to 24 months after surgery was 4 degrees. Mean loss of rib hump correction was 1.4 degrees. Mean sagittal kyphosis increased from 27 degrees at 2 months to 30.6 degrees at 24 months. Rod fractures and screw-related complications resulted in several degrees less correction than patients without complications, but overall there was no clinically significant decompensation following complications. The study concluded that there are small changes in deformity measures after endoscopic anterior scoliosis surgery, which are statistically significant but not clinically significant.