966 resultados para Endovascular Procedures
Resumo:
OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.
Resumo:
A ruptura de aneurismas intracranianos é causa rara de morbimortalidade na gravidez, havendo poucos relatos de tratamento endovascular na literatura. Documenta-se, neste relato, um caso de uma paciente de 37 anos de idade, no oitavo mês de amenorréia gestacional, apresentando quadro clínico e tomográfico compatível com hemorragia subaracnóidea (Hunt Hess III) por ruptura de aneurisma do segmento oftálmico da artéria carótida interna.
Resumo:
OBJETIVO: Este estudo tem como objetivo a avaliação pós-operatória do tratamento endovascular de aneurismas da aorta abdominal por angiotomografia com multidetectores. MATERIAIS E MÉTODOS: Foram analisadas, retrospectivamente, angiotomografias de 166 pacientes (137 homens e 29 mulheres) com idade média de 73 anos portadores de aneurisma da aorta abdominal submetidos a terapêutica endovascular, no período de junho de 2005 a agosto de 2006. Os exames foram feitos em tomógrafo multidetector de 64 canais e os parâmetros adotados foram: colimação, 0,625 mm; pitch, 0,6-1; mAs, 300-400; kV, 120. Em todos os casos foi utilizado meio de contraste iodado não-iônico (350 mg/ml) administrado por meio de bomba infusora, com fluxo de 4 ml/s a 5 ml/s e com volume variável de 70 ml a 100 ml. Os exames foram avaliados quanto à presença de complicações. RESULTADOS: Dos 166 exames realizados, 93 pacientes não apresentaram complicações e 73 apresentaram os seguintes achados: endoleak (n=37), trombose circunferencial da endoprótese (n=29), angulação (n=17), coleção no sítio de punção (n=10), migração da prótese (n=7), dissecção dos vasos de acesso (n=7) e oclusão (n=6). CONCLUSÃO: O endoleak foi a complicação mais prevalente em nosso estudo, sendo o tipo II o mais comum.
Resumo:
OBJETIVO: Relatar os resultados preliminares da aplicação da técnica de "remodelagem do colo" no tratamento dos aneurismas de colo largo da artéria renal. MATERIAIS E MÉTODOS: Cinco pacientes (três mulheres e dois homens, com idade média de 62 anos, intervalo de 49-72 anos) com aneurismas da artéria renal variando de 10 a 25 mm de diâmetro, de colo largo, foram tratados com técnicas de embolização assistidas por "remodelagem do colo" com balão durante o período de três anos. O microbalão era posicionado diante do colo do aneurisma e insuflado, temporariamente, durante a colocação das micromolas destacáveis no interior do aneurisma. RESULTADOS: O posicionamento do balão e a colocação das micromolas foram realizados com êxito em todos os casos. Oclusão completa do aneurisma, sem protrusão de micromolas ou obstrução do vaso parental, foi alcançada em todos os pacientes. CONCLUSÃO: Nossa experiência preliminar indica que a aplicação da técnica de "remodelagem do colo" no tratamento dos aneurismas de colo largo da artéria renal é tecnicamente viável e eficaz para o tratamento endovascular de aneurismas complexos da artéria renal, sem o sacrifício de qualquer ramo arterial.
Resumo:
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.
Resumo:
OBJETIVO: Relatar os resultados da aplicação de técnicas endovasculares no tratamento de aneurismas cirsoideos do couro cabeludo. MATERIAIS E MÉTODOS: Quatro pacientes com diagnóstico de aneurismas cirsoideos foram submetidos ao tratamento por via endovascular. Todos os quatro pacientes incluídos nesta série tinham malformações arteriovenosas e foram tratados apenas com embolização. RESULTADOS: Três pacientes foram submetidos a tratamento endovascular mediante embolização transarterial e um foi tratado por punção direta da porção venosa. Os resultados clínicos e cosméticos foram satisfatórios em todos os pacientes. Não houve recidiva clínica durante o período de acompanhamento. CONCLUSÃO: A via endovascular é uma alternativa segura e eficaz no tratamento dos aneurismas cirsoideos. Embora possa ser efetivamente utilizado como uma alternativa adjuvante ou complementar à cirurgia, especialmente quando é necessário lidar com aferências profundas, a maioria dos casos pode ser totalmente curada apenas com a terapêutica endovascular. A escolha do método de tratamento deve ser baseada em uma variedade de características próprias da lesão, incluindo sua angioarquitetura, tamanho e apresentação clínica.
Resumo:
OBJETIVO: Relatar uma série de casos de endoleaks, com descrição da classificação vigente. MATERIAIS E MÉTODOS: Realizou-se um estudo retrospectivo dos endoleaks diagnosticados em nossa instituição, entre 2005 e 2009. Foram incluídos 20 casos, utilizados para ilustrar os diferentes tipos de endoleaks. RESULTADOS: Setenta por cento dos pacientes eram do sexo masculino. A idade variou entre 43 e 91 anos, média de 76,3 anos. Treze casos foram observados na aorta abdominal infrarrenal, quatro na aorta torácica, dois nas artérias ilíacas e um no território carotídeo. A ultrassonografia foi o método utilizado para o diagnóstico em 3 casos e a tomografia computadorizada, nos outros 17 casos. Classificação: tipo I, 60%; tipo II, 25%; tipo III, 15%. Não foram observados os demais tipos nesta série. CONCLUSÃO: O diagnóstico precoce e a correta classificação são fundamentais para o manejo adequado dos casos de endoleaks, tornando o conhecimento de seus subtipos conceito fundamental na formação do médico especialista em radiologia e diagnóstico por imagem e para o cirurgião vascular.
Resumo:
OBJETIVO: Avaliar os resultados clínicos imediatos e em médio prazo do tratamento endovascular em pacientes portadores de aneurisma da aorta abdominal em um centro de referência para doenças cardiovasculares. MATERIAIS E MÉTODOS: Estudo retrospectivo de uma série de pacientes submetidos a tratamento endovascular de aneurisma da aorta abdominal, no período de janeiro de 2009 a julho de 2010. Foram avaliados as características demográficas, o sucesso técnico, o sucesso terapêutico, a morbimortalidade, as complicações e a taxa de reintervenções perioperatórias imediatos, e após um ano de acompanhamento. RESULTADOS: Foram analisados 102 pacientes consecutivos com idade média de 72 ± 9 anos, sendo 79% deles do sexo masculino. Houve sucesso técnico em 97,1% e êxito terapêutico em 81% dos casos. A mortalidade perioperatória foi de 0,9% e a anual, de 7,8%. Foram necessárias reintervenções em 18,8% dos pacientes durante o seguimento. CONCLUSÃO: Em nosso estudo, os resultados obtidos justificam a realização desse procedimento nos pacientes com anatomia adequada.