498 resultados para Eclipse, SODA


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy. Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the DVHs from each plan iteration. We used a tumor control probability (TCP) model to calculate losses in tumor control resulting from not accounting for the couch top and rails. We also verified dose measurements in a phantom. Results: Failure to account for the treatment couch and rails resulted in clinically unacceptable dose and volume coverage losses to the target for both IMRT and RapidArc. The couch caused average dose losses (relative to plans that ignored the couch) to the prostate of 4.2% and 2.0% for IMRT with the rails out and in, respectively, and 3.2% and 2.9% for RapidArc with the rails out and in, respectively. On average, the percentage of the target covered by the prescribed dose dropped to 35% and 84% for IMRT (rails out and in, respectively) and to 18% and 17% for RapidArc (rails out and in, respectively). The TCP was also reduced by as much as 10.5% (6.3% on average). Dose and volume coverage losses for IMRT plans were primarily due to the rails, while the imaging couch top contributed most to losses for RapidArc. Both the couch top and rails contribute to dose and coverage losses that can render plans clinically unacceptable. A follow-up study we performed found that the less attenuating unipanel mesh couch top available with the Varian Exact couch does not cause a clinically impactful loss of dose or coverage for IMRT but still causes an unacceptable loss for RapidArc. Conclusions: Both the imaging couch top and rails contribute to dose and coverage loss to a degree that, if included, would prevent the plan from meeting clinical planning criteria. Therefore, the imaging and mesh couch tops and rails should be accounted for in Arc Therapy and the imaging couch and rails only in IMRT treatment planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pregnant African American women are at higher risk of having a preterm delivery and/or a low birthweight infant. Many factors are associated with adverse pregnancy outcomes but a food habit that deserves further study in the causal process is pica, a craving for, and ingestion of, nonnutritive substances such as laundry starch, clay, dirt, or ice. This food habit is more common in the African American population but has not been adequately studied in relation to preterm and/or low birth weight infants.^ Mothers (n = 281) with infants less than one year of age who participated in the Special Supplementary Food Program for Women, Infants, and Children (WIC) at clinics in Houston and Prairie View, Texas were interviewed regarding pica practices during pregnancy, dietary practices, and some demographic indices. Hospital records were abstracted for health information on the mothers and infants, including birthweight and gestational age at birth of the infant.^ The subjects were 88.6% African American, 6.8% Hispanic, and 4.6% Caucasian. Overall prevalence of pica was 76.5%. Pica prevalence by substance(s) was as follows: ice 53.7%; ice and freezer frost 14.6%; other substances such as baking soda, baking powder, cornstarch, laundry starch, and clay or dirt 8.2%; and 23.5% reported no pica. The women who reported ice/freezer frost pica had a higher percentage of illegal drug use and alcohol use during pregnancy. The women who reported other pica substances had the lowest mean educational level, highest gravidity, and a higher percentage smoked during pregnancy.^ There were no significant differences in nutrient intakes measured by the mean 24-hour dietary recalls between women who reported ice pica (n = 103) and women who denied pica (n = 50). The women who reported ice/freezer frost pica or other pica substances had more food cravings and food dislikes during pregnancy than those who reported ice pica or no pica.^ There were no differences in mean birthweight or mean gestational age at birth of infants born to mothers from the three pica groups and the no pica group but regression analyses revealed a possible relationship between pica, low maternal hemoglobin at delivery, and preterm birth. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We previously reported a record of regionally significant volcanic eruptions in the North Pacific using an ice core from Eclipse Icefield (St. Elias Mountains, Yukon, Canada). The acquisition of two new ice cores from Eclipse Icefield, along with the previously available Eclipse Icefield and Mount Logan Northwest Col ice cores, allows us to extend our record of North Pacific volcanism to 550 years before present using a suite of four ice cores spanning an elevation range of 3 - 5 km. Comparison of volcanic sulfate flux records demonstrates that the results are highly reproducible, especially for the largest eruptions such as Katmai ( A. D. 1912). Correlation of volcanic sulfate signals with historically documented eruptions indicates that at least one-third of the eruptions recorded in St. Elias ice cores are from Alaskan and Kamchatkan volcanoes. Although there are several moderately large ( volcanic explosivity index (VEI) >= 4) eruptions recorded in only one core from Eclipse Icefield, the use of multiple cores provides signals in at least one core from all known VEI >= 4 eruptions in Alaska and Kamchatka since A. D. 1829. Tephrochronological evidence from the Eclipse ice cores documents eruptions in Alaska (Westdahl, Redoubt, Trident, and Katmai), Kamchatka (Avachinsky, Kliuchevoskoi, and Ksudach), and Iceland (Hekla). Several unidentified tephra-bearing horizons, with available geochemical evidence suggesting Alaskan and Kamchatkan sources, were also found. We present a reconstruction of annual volcanic sulfate loading for the North Pacific troposphere based on our ice core data, and we provide a detailed assessment of the atmospheric and climatic effects of the Katmai eruption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A volcanic signal observed in ice cores from both polar regions six years prior to Tambora is attributed to an unknown tropical eruption in 1809. Recovery of dacitic tephra from the 1809 horizon in a Yukon ice core ( Eclipse) that is chemically distinct from andesitic 1809 tephra found in Antarctic ice cores indicates a second eruption in the Northern Hemisphere at this time. Together with the similar magnitude and timing of the 1809 volcanic signal in the Arctic and Antarctic, this could suggest a large tropical eruption produced the sulfate and Antarctic tephra and a minor Northern Hemisphere eruption produced the Eclipse tephra. Nonetheless, the possibility that there were coincidental eruptions of similar magnitude in both hemispheres, rather than a single tropical eruption, should not be discounted. Correctly attributing the source of the 1809 volcanic signal has important implications for modeling the magnitude and latitudinal distribution of volcanic radiative forcing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Within the context of exoplanetary atmospheres, we present a comprehensive linear analysis of forced, damped, magnetized shallow water systems, exploring the effects of dimensionality, geometry (Cartesian, pseudo-spherical, and spherical), rotation, magnetic tension, and hydrodynamic and magnetic sources of friction. Across a broad range of conditions, we find that the key governing equation for atmospheres and quantum harmonic oscillators are identical, even when forcing (stellar irradiation), sources of friction (molecular viscosity, Rayleigh drag, and magnetic drag), and magnetic tension are included. The global atmospheric structure is largely controlled by a single key parameter that involves the Rossby and Prandtl numbers. This near-universality breaks down when either molecular viscosity or magnetic drag acts non-uniformly across latitude or a poloidal magnetic field is present, suggesting that these effects will introduce qualitative changes to the familiar chevron-shaped feature witnessed in simulations of atmospheric circulation. We also find that hydrodynamic and magnetic sources of friction have dissimilar phase signatures and affect the flow in fundamentally different ways, implying that using Rayleigh drag to mimic magnetic drag is inaccurate. We exhaustively lay down the theoretical formalism (dispersion relations, governing equations, and time-dependent wave solutions) for a broad suite of models. In all situations, we derive the steady state of an atmosphere, which is relevant to interpreting infrared phase and eclipse maps of exoplanetary atmospheres. We elucidate a pinching effect that confines the atmospheric structure to be near the equator. Our suite of analytical models may be used to develop decisively physical intuition and as a reference point for three-dimensional magnetohydrodynamic simulations of atmospheric circulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a secondary eclipse observation for the hot Jupiter HD 189733b across the wavelength range 290-570 nm made using the Space Telescope Imaging Spectrograph on the Hubble Space Telescope. We measure geometric albedos of Ag = 0.40 ± 0.12 across 290-450 nm and Ag < 0.12 across 450-570 nm at 1σ confidence. The albedo decrease toward longer wavelengths is also apparent when using six wavelength bins over the same wavelength range. This can be interpreted as evidence for optically thick reflective clouds on the dayside hemisphere with sodium absorption suppressing the scattered light signal beyond ~450 nm. Our best-fit albedo values imply that HD 189733b would appear a deep blue color at visible wavelengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. METHODS The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose-volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. RESULTS For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. CONCLUSIONS A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). METHODS As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. RESULTS The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V95% increased from 90% to 96% and V107% decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. CONCLUSIONS MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Open innovation is increasingly being adopted in business and describes a situation in which firms exchange ideas and knowledge with external participants, such as customers, suppliers, partner firms, and universities. This article extends the concept of open innovation with a push model of open innovation: knowledge is voluntarily created outside a firm by individuals and organisations who proceed to push knowledge into a firm’s open innovation project. For empirical analysis, we examine source code and newsgroup data on the Eclipse Development Platform. We find that outsiders invest as much in the firm’s project as the founding firm itself. Based on the insights from Eclipse, we develop four propositions: ‘preemptive generosity’ of a firm, ‘continuous commitment’, ‘adaptive governance structure’, and ‘low entry barrier’ are contexts that enable the push model of open innovation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies on issue tracking systems for open source software (OSS) focused mainly on requests for bug fixes. However, requests to add a new feature or an improvement to an OSS project are often also made in an issue tracking system. These inquiries are particularly important because they determine the further development of the software. This study examines if there is any difference between requests of the IBM developer community and other sources in terms of the likelihood of successful implementation. Our study consists of a case study of the issue tracking system BugZilla in the Eclipse integrated development environment (IDE). Our hypothesis, which was that feature requests from outsiders have less chances of being implemented, than feature requests from IBM developers, was confirmed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Briefe zwischen Mitarbeitern des Instituts für Sozialforschung und Max Horkheimer, 1964-1973; 13 Briefe und Beilagen zwischen dem Verwaltungsleiter IfS Siegfried Geissler und Max Horkheimer, 1968-1973; 9 Briefe zwischen Klaus Körber (Institut für Sozialforschung) und Max Horkheimer, 1971-1973; 2 Briefe zwischen dem Professor Rudolf Gunzert und Max Horkheimer, 1972; 2 Briefe zwischen Dr. Joachim Bergmann (Institut für Sozialforschung) und Max Horkheimer, 1971; 2 Briefe zwischen dem Professor Gerhard Brandt und Max Horkheimer, 1971; 6 Briefe zwischen Herbert Ludwig (Institut für Sozialforschung) und Max Horkheimer, 1966-1967; 3 Briefe von Max Horkheimer an Professor Franz Böhm, 1966; Briefe zwischen den Mitarbeitern des Instituts für Sozialforschung und Max Horkheimer, 1955-1959; 4 Briefe von Jürgen Habermas an Max Horkheimer, Frankfurt, 1957-1959; 3 Briefe zwischen Christoph Oehler und Max Horkheimer, 1959; 13 Briefe zwischen Ludwig von Friedeburg und Max Horkheimer, 1955-1959; 1 Brief von Werner Wilkening an Max Horkheimer, 1958; 1 Brief von Gerhard Brandt an Max Horkheimer, 1958; 1 Brief von Max Horkheimer an den Dekan Helmut Viebrock, 1958; 2 Briefe von Egon Becker mit Helge Pross und Ludwig Friedeburg an Max Horkheimer, Frankfurt, 1958-1959; 2 Briefe von Helge Pross mit Egon Becker und Ludwig Friedeburg an Max Horkheimer, Frankfurt, 1958-1959; 1 Brief von Dieter Arenz an Max Horkheimer, Frankfurt, 1956; Briefe vom und an das Institut für Sozialforschung (Advisory Board of the Institute of Social Research), 1940-1947; Briefe und Briefentwürfe an und von Mitgliedern des Advisory Board betreffend die Zusendung von Max Horkheimer "Eclipse of Reason" und Karl August Wittvogel/Olga Lang, "Chinese Family and Society"; vom Institut für Sozialforschung, 1946-1947; 1 Brief von Edwin Borchard vom Institut für Sozialforschung, 1947; 1 Brief von Friedrich Pollock an Alfred E. Cohn, Los Angeles, 1947; 1 Brief von Friedrich Pollock an Stephan Duggan, Los Angeles, 1947; 2 Briefe zwischen Lloyd K. Garrison und Friedrich. Pollock, 1947; 1 Brief von Friedrich Pollock an Calvin B. Hoover, Los Angeles, 1947; 1 Brief von Friedrich Pollock an Philip C. Jessup, Los Angeles, 1947; 1 Brief von Friedrich Pollock an Wesley C. Mitchell, Los Angeles, 1947; 1 Brief von Friedrich Pollock an William A. Neilson, Los Angeles, 1947; 1 Brief von Friedrich Pollock an Frederick M. Padelford, Los Angeles, 1947; 1 Brief von Friedrich Pollock an Thorsten Sellin, Los Angeles, 1947; 3 Briefe zwischen John Whyte und Friedrich Pollock, 1947; 2 Briefe zwischen Louis Wirth und Friedrich Pollock, 1947; 1 Brief von Friedrich Pollock an Howard Woolston, Los Angeles, 1947; 1 Brief von George H. Sabine an das Institut für Sozialforschung, Ithaca, New York, 1946; Briefe und Briefentwürfe an und von Mitgliedern des Advisory Board betreffend den Druck eines neuen Briefkopfs des Instituts, 1940; 1 Brief von Leo Löwenthal, Pacific Palisades an Margot von Mendelssohn, 1942; 1 Brief von Leo Löwenthal an Margot von Mendelssohn, Pacific Palisades, 1942; 1 Brief von Max Horkheimer an K. Pilser, 1942; 2 Briefe zwischen Charles A. Beard und Max Horkheimer, 1940; 2 Briefe zwischen Edwin M. Borchard und Max Horkheimer, 1940; 3 Briefe zwischen Henry Sloane Coffin und Max Horkheimer, 1940; 2 Briefe zwischen Morris R. Cohen und Max Horkheimer, 1940; 2 Briefe zwischen Alfred E. Cohn und Max Horkheimer, 1940; 2 Briefe zwischen Stephen Duggan und Max Horkheimer, 1940; 2 Briefe zwischen dem Soziologen Henry Pratt Fairchild und Max Horkheimer, 1940; 2 Briefe zwischen Sidney B. Fay und Max Horkheimer, 1940; 2 Briefe zwischen Lloyd K. Garrison und Max Horkheimer, 1940; 1 Brief von Max Horkheimer an Calvin B. Hoover, 1940; 2 Briefe zwischen Robert M. Hutchins und Max Horkheimer, 1940; 2 Briefe zwischen Philip C. Jessup und Max Horkheimer, 1940; 2 Briefe zwischen Lewis L. Lorwin und Max Horkheimer, 1940; 2 Briefe zwischen Robert S. Lynd und Max Horkheimer, 1940; 2 Briefe zwischen Robert M. MacIver und Max Horkheimer, 1940; 2 Briefe von Max Horkheimer an Charles H. McIlwain, 1940; 2 Briefe zwischen Charles E. Merriam und Max Horkheimer, 1940; 2 Briefe zwischen Wesley C. Mitchell und Max Horkheimer, 1940; 2 Briefe zwischen William A. Nielson und Max Horkheimer, 1940; 5 Briefe zwischen Howard W. Odum und Max Horkheimer, 1940; 3 Briefe zwischen Frederick M. Padelford und Max Horkheimer, 1940; 3 Briefe von Max Horkheimer an Max Radin, 1940; 2 Briefe zwischen George H. Sabine und Max Horkheimer, 1940; 2 Briefe zwischen Thorsten Sellin und Max Horkheimer, 1940; 2 Briefe zwischen James T. Shotwell und Max Horkheimer, 1940; 1 Brief von dem Soziologen Louis Wirth an Franz Neumann, Chicago, 1940; 1 Brief von Louis Wirth an Franz L. Neumann, Chicago, 1940; 3 Briefe zwischen Howard Woolston und Max Horkheimer, 1940;

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The high prevalence of obesity among children has spurred creation of a list of possible causative factors, including the advertising of foods of minimal nutritional value, a decrease in physical activity, and increased media use. Few studies show prevalence rates of these factors among large cohorts of children. ^ Methods. Using data from the 2004-2005 School Physical Activity and Nutrition project (SPAN), a secondary analysis of 7907 4th-grade children (mean age 9.74 years) was conducted. In addition, a comic-book–based intervention that addressed advertised food consumption, physical activity, and media use was developed and evaluated using a pre-post test design among 4th-grade children in an urban school district. ^ Results. Among a cohort of 4th-grade children across the state of Texas, children who had more than 2 hours of video game or computer time the previous day were more than twice as likely to drink soda and eat candy or pastries. In addition, children who watched more than 2 hours of TV the previous day were more than three times as likely to consume chips, punch, soda, candy, frozen desserts, or pastries (AOR 3.41, 95% CI: 1.58, 7.37). A comic-book based intervention held great promise and acceptance among 4th-grade children. Outcome evaluation showed that while results moved in a positive direction, they were not statistically significant. ^ Conclusion. Statistically significant associations were found between screen time and eating various types of advertised food. The comic book intervention was widely accepted by the children exposed to it, and pre-post surveys indicated they moved constructs in a positive direction. Further research is needed to look at more specific ways in which children are exposed to TV, and the relationship of the TV viewing time with their consumption of advertised foods. In addition, researchers should look at comic book interventions more closely and attempt to utilize them in more in studies with a longer follow-up time. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The prevalence of obesity and overweight children has been an ongoing health epidemic in the US for the last several decades. The problem has consistently worsened and has disproportionately been the most prevalent among low socioeconomic status (SES) populations. Food availability in the home has been suggested to be a potential factor related to overweight and obesity, as availability is likely associated with intake. Food availability of low SES preschool aged children has not been well examined. The purpose of this study was to explore the food environment of the Harris County Department of Education (HCDE) Head Start population, and describe reported frequency of intake of particular food groups. The effect of food availability on reported intake was also examined.^ Methods. This was a cross-sectional study of secondary data analysis. Data obtained from 17 HCDE Head Start Centers was analyzed using PASW 18 Statistical Software. Demographic analyses included population, age, gender, race, parent occupation, type of home, and language spoken in the home. Descriptive statistics included reported availability of foods in the home as well as frequency of intake.^ Regression analysis examined the relationship of availability of foods on intake. The food categories included were: dark leafy green and orange vegetables, other vegetables, fruits, soda, salty snacks, and sweet snacks. For both vegetable categories reported intake of fresh, frozen, and canned vegetables were included. For the fruit category, intake of fresh, frozen, canned, and dried fruits were reported.^ Results. Results showed that 90-95% of parents reported having vegetables and fruits available in the home. However, the only significant relationship between availability and intake was for fresh fruit and dried fruit. No associations were seen among the vegetable groups. Other vegetables (bell peppers, eggplant, tomatoes, onions, iceberg lettuce, asparagus) that were frozen, approached significance for availability on intake, however once adjusted for confounders the relationship was no longer present. Among soda, salty snacks, and sweet snacks the only significant relationship was seen for soda availability and intake. Salty snacks and sweet snacks presence in the home was not a predictor of increased frequency of intake.^ Conclusions. This research supported the hypothesis that availability of foods has an impact on intake for fresh fruits, dried fruits and soda. No associations were seen for vegetables, salty snacks and sweet snacks. Additionally, most of the parents reported having fruits and vegetables in the home, but reported intakes were not meeting the Dietary Guidelines for Americans recommendations. Strengths of the study included the large sample size taken from numerous HCDE Head Start Centers. Limitations included questionable reliability of participant’s responses, ability to generalize to other populations, and the use of secondary data rather than prospectively collected data.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effectiveness of the Anisotropic Analytical Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered such that at least 95% of Planning Target Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that were placed inside the phantom. The results demonstrate that the AAA superposition-convolution algorithm is able to calculate SBRT treatment plans with all clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil beam superposition-convolution algorithms with Monte Carlo pre-calculated scatter kernels, such as AAA, are able to reliably calculate dose, accounting for increased lateral scattering due to the loss of electronic equilibrium in low density medium. The data for high energy plans (15 MV and 18 MV) showed very good tumor coverage in contrast to findings by other investigators for less sophisticated dose calculation algorithms, which demonstrated less than expected tumor doses and generally worse tumor coverage for high energy plans compared to 6MV plans. This demonstrates that the modern superposition-convolution AAA algorithm is a significant improvement over previous algorithms and is able to calculate doses accurately for SBRT treatment plans in the highly heterogeneous environment of the thorax for both lower (≤12 MV) and higher (greater than 12 MV) beam energies.