999 resultados para Digestion methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesophilic Anaerobic Digestion treating sewage sludge was investigated at five full-scale sewage treatment plants in Ireland. The anaerobic digestion plants are compared and evaluated in terms of design, equipment, operation, monitoring and management. All digesters are cylindrical, gas mixed and heated Continuously Stirred Tank Reactors (CSTR), varying in size from 130m3 to 800m3. Heat exchanger systems heat all digesters. Three plants reported difficulties with the heating systems ranging from blockages to insufficient insulation and design. Exchangers were modified and replaced within one year of operation at two plants. All but one plant had Combined Heat and Power (CHP) systems installed. Parameter monitoring is a problem at all plants mainly due to a lack of staff and knowledge. The plant operators consider pH and temperature the most important parameters to be measured in terms of successful monitoring of an anaerobic digester. The short time taken and the ease at which pH and temperature can be measured may favour these parameters. Three laboratory scale pilot anaerobic digesters were operated using a variety of feeds over at 144-day period. Two of the pilots were unmixed and the third was mechanically mixed. As expected the unmixed reactors removed more COD by retention of solids in the digesters but also produced greater quantities of biogas than the mixed digester, especially when low solids feed such as whey was used. The mixed digester broke down more solids due to the superior contact between the substrate and the biomass. All three reactors showed good performance results for whey and sewage solids. Scum formation occurred giving operational problems for mixed and unmixed reactors when cattle slurry was used as the main feed source. The pilot test was also used to investigate which parameters were the best indicators of process instability. These trials clearly indicated that total Volatile Fatty Acid (VFA) concentrations was the best parameter to show signs of early process imbalance, while methane composition in the biogas was good to indicate possible nutrient deficiencies in the feed and oxygen shocks. pH was found to be a good process parameter only if the wastewater being treated produced low bicarbonate alkalinities during treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrokinetic transport, electrochromatography, electroosmotic flow, electrophoresis, concentration polarization, fixed beds, monoliths, dynamic NMR microscopy, quantitative confocal laser scanning microscopy, mathematical modelling, numerical analysis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Wirtschaftswiss., Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zugl.: Magdeburg, Univ., Fak. für Informatik, Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Abdominal obesity is an important cardiovascular risk factor. Therefore, identifying the best method for measuring waist circumference (WC) is a priority. Objective: To evaluate the eight methods of measuring WC in patients with acute coronary syndrome (ACS) as a predictor of cardiovascular complications during hospitalization. Methods: Prospective study of patients with ACS. The measurement of WC was performed by eight known methods: midpoint between the last rib and the iliac crest (1), point of minimum circumference (2); immediately above the iliac crest (3), umbilicus (4), one inch above the umbilicus (5), one centimeter above the umbilicus (6), smallest rib and (7) the point of greatest circumference around the waist (8). Complications included: angina, arrhythmia, heart failure, cardiogenic shock, hypotension, pericarditis and death. Logistic regression tests were used for predictive factors. Results: A total of 55 patients were evaluated. During the hospitalization period, which corresponded on average to seven days, 37 (67%) patients had complications, with the exception of death, which was not observed in any of the cases. Of these complications, the only one that was associated with WC was angina, and with every cm of WC increase, the risk for angina increased from 7.5 to 9.9%, depending on the measurement site. It is noteworthy the fact that there was no difference between the different methods of measuring WC as a predictor of angina. Conclusion: The eight methods of measuring WC are also predictors of recurrent angina after acute coronary syndromes.