972 resultados para Computer algorithms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, the authors sought to determine whether the efficiency and cost-effectiveness of cognitive-behavioral treatment (CBT) for panic disorder could be improved by adjunctive computer-assisted therapy. Eighteen participants who met Diagnostic and Statistical Manual of Mental Disorders (3rd ed., revised; American Psychiatric Association, 1987) criteria for panic disorder were randomly assigned to a 12-session CBT (CBT12) condition (D. H. Barlow & M. G. Craske, 1989) or to a 4-session computer-assisted CBT (CBT4-CA) condition. Palmtop computers, with a program developed to incorporate basic principles of CBT, were used by CBT4-CA clients whenever they felt anxious or wanted to practice the therapy techniques and were used by all participants as a momentary assessment tool. CBT4-CA clients carried the computer at all times and continued to use it for 8 weeks after termination of therapy. Analyses of clinically significant change showed superiority of CBT12 at posttest on some measures; however, there were no differences at follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The study we assessed how often patients who are manifesting a myocardial infarction (MI) would not be considered candidates for intensive lipid-lowering therapy based on the current guidelines. Methods: In 355 consecutive patients manifesting ST elevation MI (STEMI), admission plasma C-reactive protein (CRP) was measured and Framingham risk score (FRS), PROCAM risk score, Reynolds risk score, ASSIGN risk score, QRISK, and SCORE algorithms were applied. Cardiac computed tomography and carotid ultrasound were performed to assess the coronary artery calcium score (CAC), carotid intima-media thickness (cIMT) and the presence of carotid plaques. Results: Less than 50% of STEMI patients would be identified as having high risk before the event by any of these algorithms. With the exception of FRS (9%), all other algorithms would assign low risk to about half of the enrolled patients. Plasma CRP was <1.0 mg/L in 70% and >2 mg/L in 14% of the patients. The average cIMT was 0.8 +/- 0.2 mm and only in 24% of patients was >= 1.0 mm. Carotid plaques were found in 74% of patients. CAC > 100 was found in 66% of patients. Adding CAC >100 plus the presence of carotid plaque, a high-risk condition would be identified in 100% of the patients using any of the above mentioned algorithms. Conclusion: More than half of patients manifesting STEMI would not be considered as candidates for intensive preventive therapy by the current clinical algorithms. The addition of anatomical parameters such as CAC and the presence of carotid plaques can substantially reduce the CVD risk underestimation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absence of considerations of technology in policy studies reinforces the popular notion that technology is a neutral tool, Through an analysis of the role played by computers in the policy processes of Australia's Department of Social Security, this paper argues that computers are political players in policy processes, Findings indicate that computers make aspects of the social domain knowable and therefore governable, The use of computers makes previously infeasible policies possible, Computers also operate as bureaucrats and as agents of client surveillance. Increased policy change, reduced discretion and increasingly targeted and complex policies can be attributed to the use of computer technology, If policy processes are to be adequately understood and analysed, then the role of technology in those processes must be considered.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a simulated-annealing-based genetic algorithm for solving model parameter estimation problems. The algorithm incorporates advantages of both genetic algorithms and simulated annealing. Tests on computer-generated synthetic data that closely resemble optical constants of a metal were performed to compare the efficiency of plain genetic algorithms against the simulated-annealing-based genetic algorithms. These tests assess the ability of the algorithms to and the global minimum and the accuracy of values obtained for model parameters. Finally, the algorithm with the best performance is used to fit the model dielectric function to data for platinum and aluminum. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider algorithms for computing the Smith normal form of integer matrices. A variety of different strategies have been proposed, primarily aimed at avoiding the major obstacle that occurs in such computations-explosive growth in size of intermediate entries. We present a new algorithm with excellent performance. We investigate the complexity of such computations, indicating relationships with NP-complete problems. We also describe new heuristics which perform well in practice. Wie present experimental evidence which shows our algorithm outperforming previous methods. (C) 1997 Academic Press Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of parameter-space size adjustment is pn,posed in order to enable successful application of genetic algorithms to continuous optimization problems. Performance of genetic algorithms with six different combinations of selection and reproduction mechanisms, with and without parameter-space size adjustment, were severely tested on eleven multiminima test functions. An algorithm with the best performance was employed for the determination of the model parameters of the optical constants of Pt, Ni and Cr.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Current advances in frame modeling and computer software allow stereotactic procedures to be performed with great accuracy and minimal risk of neural tissue or vascular injury. Case Report: In this report we associate a previously described minimally invasive stereotactic technique with state-of-the-art 3D computer guidance technology to successfully treat a 55-year-old patient with an arachnoidal cyst obstructing the aqueduct of Sylvius. We provide 1 detailed technical information and discuss how this technique deals with previous limitations for stereotactic manipulation of the aqueductal region. We further discuss current advances in neuroendoscopy for treating obstructive hydrocephalus and make comparisons with our proposed technique. Conclusion: We advocate that this technique is not only capable of treating this pathology but it also has the advantages to enable reestablishment of physiological CSF flow thus preventing future brainstem compression by cyst enlargement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study is to evaluate blood glucose (BG) control efficacy and safety of 3 insulin protocols in medical intensive care unit (MICU) patients. Methods: This was a multicenter randomized controlled trial involving 167 MICU patients with at least one BG measurement +/- 150 mg/dL and one or more of the following: mechanical ventilation, systemic inflammatory response syndrome, trauma, or burns. The interventions were computer-assisted insulin protocol (CAIP), with insulin infusion maintaining BG between 100 and 130 mg/dL; Leuven protocol, with insulin maintaining BG between 80 and 110 mg/dL; or conventional treatment-subcutaneous insulin if glucose > 150 mg/dL. The main efficacy outcome was the mean of patients` median BG, and the safety outcome was the incidence of hypoglycemia (<= 40 mg/dL). Results: The mean of patients` median BG was 125.0, 127.1, and 158.5 mg/dL for CAIP, Leuven, and conventional treatment, respectively (P = .34, CAIP vs Leuven; P < .001, CAIP vs conventional). In CAIP, 12 patients (21.4%) had at least one episode of hypoglycemia vs 24 (41.4%) in Leuven and 2 (3.8%) in conventional treatment (P = .02, CAIP vs Leuven; P = .006, CAIP vs conventional). Conclusions: The CAIP is safer than and as effective as the standard strict protocol for controlling glucose in MICU patients. Hypoglycemia was rare under conventional treatment. However, BG levels were higher than with IV insulin protocols. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.