917 resultados para Communication in medicine.
Resumo:
Clinical epidemiology is the most currently used name for a comparatively new branch of medicine covering a certain number of activities related to the practice of clinical medicine, but using epidemiological techniques and methods. Clinical epidemiology has only just begun to be known in Europe, whereas units are being increasingly developed and expanded in North America, particularly within the clinical departments of hospitals. The methods it offers are valid for both practicing physicians and hospital doctors (or those being trained in hospitals) and serve the purpose of promoting a better quality medical service, especially where a more adequate evaluation of the effectiveness of diagnostic methods, therapy and prognosis in medicine is concerned. Clinical epidemiology proposes a methodology of medical reasoning and of decision-making, as well as techniques intended to facilitate the indispensable task of keeping up with advances in medical knowledge.
Resumo:
An online algorithm for determining respiratory mechanics in patients using non-invasive ventilation (NIV) in pressure support mode was developed and embedded in a ventilator system. Based on multiple linear regression (MLR) of respiratory data, the algorithm was tested on a patient bench model under conditions with and without leak and simulating a variety of mechanics. Bland-Altman analysis indicates reliable measures of compliance across the clinical range of interest (± 11-18% limits of agreement). Resistance measures showed large quantitative errors (30-50%), however, it was still possible to qualitatively distinguish between normal and obstructive resistances. This outcome provides clinically significant information for ventilator titration and patient management.
Resumo:
Since 1895, when X-rays were discovered, ionizing radiation became part of our life. Its use in medicine has brought significant health benefits to the population globally. The benefit of any diagnostic procedure is to reduce the uncertainty about the patient's health. However, there are potential detrimental effects of radiation exposure. Therefore, radiation protection authorities have become strict regarding the control of radiation risks.¦There are various situations where the radiation risk needs to be evaluated. International authority bodies point to the increasing number of radiologic procedures and recommend population surveys. These surveys provide valuable data to public health authorities which helps them to prioritize and focus on patient groups in the population that are most highly exposed. On the other hand, physicians need to be aware of radiation risks from diagnostic procedures in order to justify and optimize the procedure and inform the patient.¦The aim of this work was to examine the different aspects of radiation protection and investigate a new method to estimate patient radiation risks.¦The first part of this work concerned radiation risk assessment from the regulatory authority point of view. To do so, a population dose survey was performed to evaluate the annual population exposure. This survey determined the contribution of different imaging modalities to the total collective dose as well as the annual effective dose per caput. It was revealed that although interventional procedures are not so frequent, they significantly contribute to the collective dose. Among the main results of this work, it was shown that interventional cardiological procedures are dose-intensive and therefore more attention should be paid to optimize the exposure.¦The second part of the project was related to the patient and physician oriented risk assessment. In this part, interventional cardiology procedures were studied by means of Monte Carlo simulations. The organ radiation doses as well as effective doses were estimated. Cancer incidence risks for different organs were calculated for different sex and age-at-exposure using the lifetime attributable risks provided by the Biological Effects of Ionizing Radiations Report VII. Advantages and disadvantages of the latter results were examined as an alternative method to estimate radiation risks. The results show that this method is the most accurate, currently available, to estimate radiation risks. The conclusions of this work may guide future studies in the field of radiation protection in medicine.¦-¦Depuis la découverte des rayons X en 1895, ce type de rayonnement a joué un rôle important dans de nombreux domaines. Son utilisation en médecine a bénéficié à la population mondiale puisque l'avantage d'un examen diagnostique est de réduire les incertitudes sur l'état de santé du patient. Cependant, leur utilisation peut conduire à l'apparition de cancers radio-induits. Par conséquent, les autorités sanitaires sont strictes quant au contrôle du risque radiologique.¦Le risque lié aux radiations doit être estimé dans différentes situations pratiques, dont l'utilisation médicale des rayons X. Les autorités internationales de radioprotection indiquent que le nombre d'examens et de procédures radiologiques augmente et elles recommandent des enquêtes visant à déterminer les doses de radiation délivrées à la population. Ces enquêtes assurent que les groupes de patients les plus à risque soient prioritaires. D'un autre côté, les médecins ont également besoin de connaître le risque lié aux radiations afin de justifier et optimiser les procédures et informer les patients.¦Le présent travail a pour objectif d'examiner les différents aspects de la radioprotection et de proposer une manière efficace pour estimer le risque radiologique au patient.¦Premièrement, le risque a été évalué du point de vue des autorités sanitaires. Une enquête nationale a été réalisée pour déterminer la contribution des différentes modalités radiologiques et des divers types d'examens à la dose efficace collective due à l'application médicale des rayons X. Bien que les procédures interventionnelles soient rares, elles contribuent de façon significative à la dose délivrée à la population. Parmi les principaux résultats de ce travail, il a été montré que les procédures de cardiologie interventionnelle délivrent des doses élevées et devraient donc être optimisées en priorité.¦La seconde approche concerne l'évaluation du risque du point de vue du patient et du médecin. Dans cette partie, des procédures interventionnelles cardiaques ont été étudiées au moyen de simulations Monte Carlo. La dose délivrée aux organes ainsi que la dose efficace ont été estimées. Les risques de développer des cancers dans plusieurs organes ont été calculés en fonction du sexe et de l'âge en utilisant la méthode établie dans Biological Effects of Ionizing Radiations Report VII. Les avantages et inconvénients de cette nouvelle technique ont été examinés et comparés à ceux de la dose efficace. Les résultats ont montré que cette méthode est la plus précise actuellement disponible pour estimer le risque lié aux radiations. Les conclusions de ce travail pourront guider de futures études dans le domaine de la radioprotection en médicine.
Resumo:
Specialisation in medicine requires multidisciplinary approaches, and hence coordination in collaborations of the different partners involved. These integrated approaches, sometimes called "disease management", fit particularly well to chronic diseases. Our institution introduced an integrated approach for taking care of the acute somatic hospitalisation of patients suffering from anorexia nervosa. Interfaces with the different partners were defined, specifying tasks, rights, and duties of each person, care givers or patients. This initiative allows now to identify any deviation occurring in the process of care or hole in the care system, so that it can be corrected and recurrence prevented. This model will be extended to other complex and multidisciplinary care processes and other services in our institution.
Resumo:
Songs were the means used by the Romanian Communist Party to ‘educate’ Romanians. Through them, Romanians were told what they had to appreciate, how grateful they were supposed to be to the regime, how great President Ceausescu was and how they had to work harder and harder so that they could be even better Communists. This paper comprises the translation of three songs composed, performed and broadcast in Communist Romania and their analysis from the point of view of communication. In translating the song, I have chosen to translate closest to the original possible meaning and meanwhile to respect to the best of my ability Low’s ‘pentathlon principle’: singability, rhyme, rhythm, naturalness and fidelity to the sense of the source text
Resumo:
High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance frequency f(0) and the radiofrequency power to generate the intended local B(1)+ field. In this work, dual echo time B(0)-map and dual flip angle B(1)+-map acquisition methods are combined to acquire multislice B(0)- and B(1)+-maps simultaneously covering the entire heart in a single breath hold of 18 heartbeats. A previously proposed excitation pulse shape dependent slice profile correction is tested and applied to reduce systematic errors of the multislice B(1)+-map. Localized higher-order shim correction values including the zero-order terms for frequency f(0) and radiofrequency power can be determined based on the acquired B(0)- and B(1)+-maps. This method has been tested in 7 healthy adult human subjects at 3 T and improved the B(0) field homogeneity (standard deviation) from 60 Hz to 35 Hz and the average B(1)+ field from 77% to 100% of the desired B(1)+ field when compared to more commonly used preparation methods.
Resumo:
The behavioural response of Triatoma pseudomaculata to chemical substances present in their faeces or cuticle (footprints) was analyzed. Groups of larvae were simultaneously exposed to a clean filter paper and to another paper impregnated with a chemical stimulus in a circular arena. In these choice experiments, the insects aggregated significantly around papers impregnated with dry faeces. In addition, the bugs also showed a significant aggregation response to papers impregnated with compounds derived from their cuticle that were deposited by contact on the substrate. These results indicate that chemical compounds that affect the behaviour of T. pseudomaculata are present in the faeces and in the cuticle of this species. Results are discussed in relation to chemical communication in the Triatominae, as well as to the potential use of these substances in traps or sensors for the detection of this species.
Resumo:
Introduction Lesion detection in multiple sclerosis (MS) is an essential part of its clinical diagnosis. In addition, radiological characterisation of MS lesions is an important research field that aims at distinguishing different MS types, monitoring drug response and prognosis. To date, various MR protocols have been proposed to obtain optimal lesion contrast for early and comprehensive diagnosis of the MS disease. In this study, we compare the sensitivity of five different MR contrasts for lesion detection: (i) the DIR sequence (Double Inversion Recovery, [4]), (ii) the Dark-fluid SPACE acquisition schemes, a 3D variant of a 2D FLAIR sequence [1], (iii) the MP2RAGE [2], an MP-RAGE variant that provides homogeneous T1 contrast and quantitative T1-values, and the sequences currently used for clinical MS diagnosis (2D FLAIR, MP-RAGE). Furthermore, we investigate the T1 relaxation times of cortical and sub-cortical regions in the brain hemispheres and the cerebellum at 3T. Methods 10 early-stage female MS patients (age: 31.64.7y; disease duration: 3.81.9y; disability score, EDSS: 1.80.4) and 10 healthy controls (age and gender-matched: 31.25.8y) were included in the study after obtaining informed written consent according to the local ethic protocol. All experiments were performed at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil [5]. The imaging protocol included the following sequences, (all except for axial FLAIR 2D with 1x1x1.2 mm3 voxel and 256x256x160 matrix): DIR (TI1/TI2/TR XX/3652/10000 ms, iPAT=2, TA 12:02 min), MP-RAGE (TI/TR 900/2300 ms, iPAT=3, TA 3:47 min); MP2RAGE (TI1/TI2/TR 700/2500/5000 ms, iPAT=3, TA 8:22 min, cf. [2]); 3D FLAIR SPACE (only for patient 4-6, TI/TR 1800/5000 ms, iPAT=2, TA=5;52 min, cf. [1]); Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix, TI/TR 2500/9000 ms, iPAT=2, TA 4:05 min). Lesions were identified by two experienced neurologist and radiologist, manually contoured and assigned to regional locations (s. table 1). Regional lesion masks (RLM) from each contrast were compared for number and volumes of lesions. In addition, RLM were merged in a single "master" mask, which represented the sum of the lesions of all contrasts. T1 values were derived for each location from this mask for patients 5-10 (3D FLAIR contrast was missing for patient 1-4). Results & Discussion The DIR sequence appears the most sensitive for total lesions count, followed by the MP2RAGE (table 1). The 3D FLAIR SPACE sequence turns out to be more sensitive than the 2D FLAIR, presumably due to reduced partial volume effects. Looking for sub-cortical hemispheric lesions, the DIR contrast appears to be equally sensitive to the MP2RAGE and SPACE, but most sensitive for cerebellar MS plaques. The DIR sequence is also the one that reveals cortical hemispheric lesions best. T1 relaxation times at 3T in the WM and GM of the hemispheres and the cerebellum, as obtained with the MP2RAGE sequence, are shown in table 2. Extending previous studies, we confirm overall longer T1-values in lesion tissue and higher standard deviations compared to the non-lesion tissue and control tissue in healthy controls. We hypothesize a biological (different degree of axonal loss and demyelination) rather than technical origin. Conclusion In this study, we applied 5 MR contrasts including two novel sequences to investigate the contrast of highest sensitivity for early MS diagnosis. In addition, we characterized for the first time the T1 relaxation time in cortical and sub-cortical regions of the hemispheres and the cerebellum. Results are in agreement with previous publications and meaningful biological interpretation of the data.
Resumo:
The quantity of interest for high-energy photon beam therapy recommended by most dosimetric protocols is the absorbed dose to water. Thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (TPS). However, when measurements are performed in a low-density medium, the presence of the ionization chamber generates a perturbation at the level of the secondary particle range. Therefore, the measured quantity is close to the absorbed dose to a volume of water equivalent to the chamber volume. This quantity is not equivalent to the dose calculated by a TPS, which is the absorbed dose to an infinitesimally small volume of water. This phenomenon can lead to an overestimation of the absorbed dose measured with an ionization chamber of up to 40% in extreme cases. In this paper, we propose a method to calculate correction factors based on the Monte Carlo simulations. These correction factors are obtained by the ratio of the absorbed dose to water in a low-density medium □D(w,Q,V1)(low) averaged over a scoring volume V₁ for a geometry where V₁ is filled with the low-density medium and the absorbed dose to water □D(w,QV2)(low) averaged over a volume V₂ for a geometry where V₂ is filled with water. In the Monte Carlo simulations, □D(w,QV2)(low) is obtained by replacing the volume of the ionization chamber by an equivalent volume of water, according to the definition of the absorbed dose to water. The method is validated in two different configurations which allowed us to study the behavior of this correction factor as a function of depth in phantom, photon beam energy, phantom density and field size.
Resumo:
Résumé en français Après un examen critique de la théorie des médias et de la culture développée par l'Ecole de Francfort, abordée ici principalement au travers des oeuvres de T.W. Adorno et de Jürgen Habeimas, ce travail en propose une reconstruction en s'inspirant de la théorie de la reconnaissance d'Axel Honneth. Envisagée sous un angle narratif, la communication publique est vue comme un processus engageant à la fois des relations de reconnaissance et leur négation sous la double forme de la réification et du mépris. La recherche développe une approche des médias sensible à ces tensions et conflits ainsi qu'aux luttes pour la reconnaissance qui travaillent la scène publique, y compris dans sa dimension esthétique. Title and abstract in english « Public sphere, mediations, recognition. Reconstruction elements of a critical theory of communication ». After a critical discussion of media and culture theory developped by the Frankfurt School presented here mainly through the works of T.W. Adorno and Jürgen Habermas, this research proposes to reconstruct it on the basis of the theory of recognition developed by Axel Honneth. Considered through the perspective of narrative, public communication in is seen as a process implying at the same time recognition relations and their negation through the double process of reification and disrespect. The research develops an approach of media which is attentive to those tensions and conflicts and to the struggles for recognition that forms public sphere, also in his aesthetic dimension.
Resumo:
Background: Although the proportion of women in medicine is growing, female physicians continue to be disadvantaged in professional activities. The purpose of the study was to determine and compare the professional activities of female and male primary care physicians in Andalusia and to assess the effect of the health center on the performance of these activities. Methods: Descriptive, cross-sectional, and multicenter study. Setting: Spain. Participants: Population: urban health centers and their physicians. Sample: 88 health centers and 500 physicians. Independent variable: gender. Measurements: Control variables: age, postgraduate family medicine specialty (FMS), patient quota, patients/day, hours/day housework from Monday to Friday, idem weekend, people at home with special care, and family situation. Dependent variables: 24 professional activities in management, teaching, research, and the scientific community. Self-administered questionnaire. Descriptive, bivariate, and multilevel logistic regression analyses. Results: Response: 73.6%. Female physicians: 50.8%. Age: female physicians, 49.1 ± 4.3 yrs; male physicians, 51.3 ± 4.9 yrs (p < 0.001). Female physicians with FMS: 44.2%, male physicians with FMS: 33.3% (p < 0.001). Female physicians dedicated more hours to housework and more frequently lived alone versus male physicians. There were no differences in healthcare variables. Thirteen of the studied activities were less frequently performed by female physicians, indicating their lesser visibility in the production and diffusion of scientific knowledge. Performance of the majority of professional activities was independent of the health center in which the physician worked. Conclusions: There are gender inequities in the development of professional activities in urban health centers in Andalusia, even after controlling for family responsibilities, work load, and the effect of the health center, which was important in only a few of the activities under study.
Resumo:
L'objectiu d'aquest projecte és dissenyar i implementar un servei de telefonia IP per a la Unitat de Tecnologies de la Informació i Comunicació (UTIC) de l'Institut Català de la Salut (ICS) a Girona. En primer lloc, es descriu el funcionament actual del servei de telefonia de l'ICS a Girona i la seva infraestructura de xarxa. A continuació s’estudia els fonaments de la VoIP. Es segueix amb el disseny, les eines escollides i la implementació realitzada, per acabar amb les conclusions
Resumo:
The aim of this study was to propose a methodology allowing a detailed characterization of body sit-to-stand/stand-to-sit postural transition. Parameters characterizing the kinematics of the trunk movement during sit-to-stand (Si-St) postural transition were calculated using one initial sensor system fixed on the trunk and a data logger. Dynamic complexity of these postural transitions was estimated by fractal dimension of acceleration-angular velocity plot. We concluded that this method provides a simple and accurate tool for monitoring frail elderly and to objectively evaluate the efficacy of a rehabilitation program.