996 resultados para COLOR-FLOW DUPLEX
Resumo:
Pulp lifters, also known, as pan lifters are an integral part of the majority of autogenous (AG), semi-autogenous (SAG) and grate discharge ball mills. The performance of the pulp lifters in conjunction with grate design determines the ultimate flow capacity of these mills. Although the function of the pulp lifters is simply to transport the slurry passed through the discharge grate into the discharge trunnion, their performance depends on their design as well as that of the grate and operating conditions such as mill speed and charge level. However, little or no work has been reported on the performance of grate-pulp lifter assemblies and in particular the influence of pulp lifter design on slurry transport. Ideally, the discharge rate through a grate-pulp lifter assembly should be equal to the discharge rate through at a given mill hold-up. However, the results obtained have shown that conventional pulp lifter designs cause considerable restrictions to flow resulting in reduced flow capacity. In this second of a two-part series of papers the performance of conventional pulp lifters (radial and spiral designs) is described and is based on extensive test work carried out in a I m diameter pilot SAG mill. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Discharge grates play an important role in determining the performance of autogenous, semi-autogenous and grate discharge ball mills. The flow capacity (grinding capacity) of these mills is strongly influenced by the discharge grate design-open area and position of apertures, as well as the performance of the pulp lifters. As mill sizes have progressively increased and closed-circuiting has become more popular the importance of grate and pulp lifter design has grown. Unfortunately very few studies have concentrated on this aspect of mill performance. To remedy this a series of laboratory and pilot-scale tests were undertaken to study both the performance of grates on their own and in conjunction with pulp lifters. In this first paper of a two-part series the results from the grate-only experiments are presented and discussed, whilst the performance of the grate-pulp-lifter system is covered in the second paper. The results from the grate-only experiments have shown that the build-up of slurry (hold-up) inside the mill starts from the shoulder of the charge, while the toe position of the slurry progressively moves towards the toe of the charge with increasing flowrate. Besides grate design (open area and position of apertures), charge volume and mill speed were also found to have a strong influence on mill hold-up and interact with grate design variables. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Today, the standard approach for the kinetic analysis of dynamic PET studies is compartment models, in which the tracer and its metabolites are confined to a few well-mixed compartments. We examine whether the standard model is suitable for modern PET data or whether theories including more physiologic realism can advance the interpretation of dynamic PET data. A more detailed microvascular theory is developed for intravascular tracers in single-capillary and multiple-capillary systems. The microvascular models, which account for concentration gradients in capillaries, are validated and compared with the standard model in a pig liver study. Methods: Eight pigs underwent a 5-min dynamic PET study after O-15-carbon monoxide inhalation. Throughout each experiment, hepatic arterial blood and portal venous blood were sampled, and flow was measured with transit-time flow meters. The hepatic dual-inlet concentration was calculated as the flow-weighted inlet concentration. Dynamic PET data were analyzed with a traditional single-compartment model and 2 microvascular models. Results: Microvascular models provided a better fit of the tissue activity of an intravascular tracer than did the compartment model. In particular, the early dynamic phase after a tracer bolus injection was much improved. The regional hepatic blood flow estimates provided by the microvascular models (1.3 +/- 0.3 mL min(-1) mL(-1) for the single-capillary model and 1.14 +/- 0.14 min(-1) mL(-1) for the multiple-capillary model) (mean +/- SEM mL of blood min(-1) mL of liver tissue(-1)) were in agreement with the total blood flow measured by flow meters and normalized to liver weight (1.03 +/- 0.12 mL min(-1) mL(-1)). Conclusion: Compared with the standard compartment model, the 2 microvascular models provide a superior description of tissue activity after an intravascular tracer bolus injection. The microvascular models include only parameters with a clear-cut physiologic interpretation and are applicable to capillary beds in any organ. In this study, the microvascular models were validated for the liver and provided quantitative regional flow estimates in agreement with flow measurements.
Resumo:
Direct numerical simulation has been carried out for turbulent flow set up by a rotating cylinder with two backward-facing steps axisymmetrically mounted in the circumferential direction. This flow geometry creates a qualitatively similar flow pattern as observed near, a sudden, pipe expansion or a plane backward-facing step, characterized by flow separation and reattachment. A region of intense turbulence intensity and high wall-shear-stress fluctuations is formed in,the recirculating I region downstream of the step, where high mass-transfer capacity was also experimentally observed. Since, corrosion is frequently mass-transfer., controlled, our findings, put forward this apparatus as useful tool for future corrosion research.
Resumo:
Heat transfer levels have been investigated behind a rearward-facing step in a superorbital expansion tube. The heat transfer was measured along a flat plate and behind 2 and 3mm steps with the same length to step height ratio. Results were obtained with air as the test gas at speeds of 6.76kms(-1) and 9-60kms(-1) corresponding to stagnation enthalpies of 26MJ/kg and 48MJ/kg respectively. A laminar boundary layer was established on the flat plate and measured heat transfer levels were consistent with classical empirical correlations. In the case of flow behind a step, the measurements showed a gradual rise in heat transfer from the rear of the step to a plateau several step heights downstream for both flow conditions. Reattachment distance was estimated to be approximately 1.6 step heights downstream of the 2mm step at the low enthalpy condition through the use of flow visualisation.
Resumo:
B-type natriuretic peptide (BNP) levels increase in systolic heart failure (HF). However, the value of BNP in hypertensive patients with suspected diastolic HF (symptoms suggestive of HF but normal ejection fraction) and its relation to myocardial function in these patients is unclear. We prospectively studied 72 ambulatory hypertensive subjects (40 women, mean age 58 +/- 8 years) with exertional dyspnea and ejection fraction greater than or equal to50%. Diastolic function was evaluated with transmitral and pulmonary venous Doppler, mitral annular velocities (pulsed-wave tissue Doppler), and flow propagation velocity (color M-mode). Systolic function was assessed with strain and strain rate derived from color tissue Doppler imaging. BNP was related to myocardial function and the presence or absence of global diastolic dysfunction. By conventional Doppler criteria, 34 patients had normal left ventricular diastolic function and 38 had isolated diastolic dysfunction. BNP values were higher in patients with diastolic dysfunction (46 +/- 48 vs 20 +/- 20 pg/ml, p = 0.004) and were related independently to blood pressure, systolic strain rate, left atrial function (p < 0.01 for all), and age (p = 0.015). Patients with diastolic dysfunction and pseudonormal filling had higher BNP levels compared with impaired relaxation (89 +/- 47 vs 35 +/- 42 pg/ml, p = 0.001). However, 79% of patients with diastolic dysfunction had BNP levels within the normal range. We conclude that in ambulatory hypertensive patients with symptoms suggestive of mild HF and normal ejection fraction, BNP is related to atrial and ventricular systolic parameters, blood pressure, and age. Although elevated in the presence of diastolic dysfunction, the BNP level mostly is in the normal range and, therefore, has limited diagnostic value in stable patients with suspected diastolic HF. (C) 2003 by Excerpta Medica, Inc.
Resumo:
Recent advances in molecular biology have made it possible to use the trace amounts of DNA in faeces to non-invasively sample endangered species for genetic studies. Here we use faeces as a source of DNA and mtDNA sequence data to elucidate the relationship among Spanish and Moroccan populations of great bustards. 834 bp of combined control region and cytochrome-b mtDNA fragments revealed four variable sites that defined seven closely related haplotypes in 54 individuals. Morocco was fixed for a single mtDNA haplotype that occurs at moderate frequency (28%) in Spain. We could not differentiate among the sampled Spanish populations of Caceres and Andalucia but these combined populations were differentiated from the Moroccan population. Estimates of gene flow (Nm = 0.82) are consistent with extensive observations on the southern Iberian peninsular indicating that few individuals fly across the Strait of Gibraltar. We demonstrate that both this sea barrier and mountain barriers in Spain limit dispersal among adjacent great bustard populations to a similar extent. The Moroccan population is of high ornithological significance as it holds the only population of great bustards in Africa. This population is critically small and genetic and observational data indicate that it is unlikely to be recolonised via immigration from Spain should it be extirpated. In light of the evidence presented here it deserves the maximum level of protection.
Resumo:
Myocardial contractility depends on several mechanisms such as coronary perfusion pressure (CPP) and flow as well as on a1-adrenoceptor stimulation. Both effects occur during the sympathetic stimulation mediated by norepinephrine. Norepinephrine increases force development in the heart and produces vasoconstriction increasing arterial pressure and, in turn, CPP. The contribution of each of these factors to the increase in myocardial performance needs to be clarified. Thus, in the present study we used two protocols: in the first we measured mean arterial pressure, left ventricular pressure and rate of rise of left ventricular pressure development in anesthetized rats (N = 10) submitted to phenylephrine (PE) stimulation before and after propranolol plus atropine treatment. These observations showed that in vivo a1-adrenergic stimulation increases left ventricular-developed pressure (P<0.05) together with arterial blood pressure (P<0.05). In the second protocol, we measured left ventricular isovolumic systolic pressure (ISP) and CPP in Langendorff constant flow-perfused hearts. The hearts (N = 7) were perfused with increasing flow rates under control conditions and PE or PE + nitroprusside (NP). Both CPP and ISP increased (P<0.01) as a function of flow. CPP changes were not affected by drug treatment but ISP increased (P<0.01). The largest ISP increase was obtained with PE + NP treatment (P<0.01). The results suggest that both mechanisms, i.e., direct stimulation of myocardial a1-adrenoceptors and increased flow, increased cardiac performance acting simultaneously and synergistically.
Resumo:
This work discusses the use of optical flow to generate the sensorial information a mobile robot needs to react to the presence of obstacles when navigating in a non-structured environment. A sensing system based on optical flow and time-to-collision calculation is here proposed and experimented, which accomplishes two important paradigms. The first one is that all computations are performed onboard the robot, in spite of the limited computational capability available. The second one is that the algorithms for optical flow and time-to-collision calculations are fast enough to give the mobile robot the capability of reacting to any environmental change in real-time. Results of real experiments in which the sensing system here proposed is used as the only source of sensorial data to guide a mobile robot to avoid obstacles while wandering around are presented, and the analysis of such results allows validating the proposed sensing system.
Resumo:
O comportamento da corrosão e inibição à corrosão dos aços carbono AISI 1010, inox AISI 316 e duplex UNS S31803 foi estudado em meio de solução de íons cloreto à 3,0% (m/v), na ausência e presença do benzimidazol e imidazol como inibidores. A caracterização química e morfológica dos aços foi realizada por meio das técnicas de espectrometria de emissão ótica, difração de raios X (DRX), microscopia ótica, microscopia eletrônica de varredura (MEV) e energia dispersiva de raios X (EDX). As análises eletroquímicas foram realizadas através das técnicas de polarização potenciodinâmica e espectroscopia de impedância eletroquímica. As análises de DRX e de metalografia mostraram as fases presentes em cada aço, sendo o aço AISI 1010 composto pela fase ferrita, o aço AISI 316 pelas fases de FeNi e Cr e o aço UNS S31803 pelas fases austenita e ferrita. Além disso, a metalografia e as análises de MEV e EDX permitiram identificar regiões e certos elementos presentes nos aços que propiciam à ocorrência da corrosão, tais como inclusões. Os inibidores foram testados em diferentes concentrações (25 ppm, 50 ppm, 100 ppm, 500 ppm e 1000 ppm) para os três aços, através das curvas de polarização e impedância eletroquímica, e verificou-se que para todas as concentrações houve aumento da resistência à corrosão dos aços. Pelas curvas de polarização verificou-se que o benzimidazol proporcionou aos aços AISI 1010, AISI 316 e UNS S31803, eficiências de inibição de cerca de 51%, 71% e 75%, respectivamente. Enquanto que o imidazol apresentou eficiência de cerca de 73%, 95% e 86%, respectivamente. Os resultados de impedância eletroquímica mostraram que as eficiências de inibição do benzimidazol foram de aproximadamente 52%, 73% e 71%, respectivamente, para os aços AISI 1010, AISI 316 e UNS S31803. E por sua vez, o imidazol apresentou eficiências de aproximadamente 96% para os aços AISI 1010 e AISI 316 e 85% para o aço UNS S31803. O teste de perda de massa mostrou que para o aço AISI 1010 tanto o benzimidazol quanto e o imidazol inibiram a corrosão, sendo que reduziram a corrosão em cerca de 17% e 24%, respectivamente. Nas análises das curvas de polarização em estudos com a água do mar observou-se que os inibidores foram menos eficientes do que em meio de solução de cloreto. O benzimidazol obteve eficiências de cerca de 14%, 50% e 33%, respectivamente, para os aços AISI 1010, AISI 316 e UNS S31803. Enquanto que o imidazol apresentou eficiências de aproximadamente 21%, 59% e 34%, respectivamente. Em todas as análises eletroquímicas e análise de perda de massa, o imidazol se mostrou o melhor inibidor para os aços estudados.
Resumo:
Visando a aplicação do aço UNS S32304 em embalados para transporte de material radioativo, amostras soldadas por processo TIG, com diferentes gases de proteção, foram submetidas a tratamentos térmicos nas temperaturas de 475°C, 600°C e 750°C por 8 horas, seguidas de resfriamento ao ar, a fim de analisar o efeito de temperaturas críticas no perfil de tensões residuais e microestrutura. A difratometria de raios X foi utilizada para determinação das tensões residuais, em diferentes condições (amostras como recebidas e apenas tratadas termicamente) e o perfil de tensões residuais total das amostras soldadas é apresentado para cada fase (austenita e ferrita). As tensões residuais das fases foram determinadas pela técnica sen2ψ, utilizando um difratômetro com fonte de radiação CuKα (<λ
Resumo:
Color model representation allows characterizing in a quantitative manner, any defined color spectrum of visible light, i.e. with a wavelength between 400nm and 700nm. To accomplish that, each model, or color space, is associated with a function that allows mapping the spectral power distribution of the visible electromagnetic radiation, in a space defined by a set of discrete values that quantify the color components composing the model. Some color spaces are sensitive to changes in lighting conditions. Others assure the preservation of certain chromatic features, remaining immune to these changes. Therefore, it becomes necessary to identify the strengths and weaknesses of each model in order to justify the adoption of color spaces in image processing and analysis techniques. This chapter will address the topic of digital imaging, main standards and formats. Next we will set the mathematical model of the image acquisition sensor response, which enables assessment of the various color spaces, with the aim of determining their invariance to illumination changes.
Resumo:
The objective of this study was to evaluate the influence of the color and phenolic compounds of strawberry jam on acceptance during storage. Jams were processed, stored for 120 days and evaluated monthly for chromatic characteristics, total phenolic compounds, total anthocyanins (ANT), total ellagic acid (TEA), flavonoids and free ellagic acid (FEA), and sensory acceptance as well. Data were submitted to analysis of variance (ANOVA) and the means were compared by the Least Significant Difference (LSD). Cluster Analysis and Partial Least Square Regression (PLS) were performed to investigate the relationships between instrumental data and acceptance. Contents of ANT, TEA and redness decreased during storage. Other chemical characteristics and sensory acceptance showed a nonlinear behavior. Higher acceptance was observed after 60 days, suggesting a trend of quality improvement followed by decline to the initial levels. The same trend was observed for lightness, non-pigment flavonoids and FEA. According to PLS map, for consumers in cluster 2, acceptance was associated to jams at 60 days and to luminosity, FEA, and non-pigment flavonoids. For cluster 1, a positive association between flavor liking, jam at initial storage, and the contents of TEA and ANT was indicated. Jams at 120 days were positively associated to hue and negatively associated to color liking, for cluster 1. Color and texture were positively correlated to overall liking for cluster 2, whereas for cluster 1, overall acceptance seemed to be more associated to flavor liking. Changes in color and phenolic compounds slightly influenced the acceptance of strawberry jams, but in different ways for consumers clusters.