433 resultados para Breath


Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Autograph edition limited to 750 copies."

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). BACKGROUND Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. METHODS Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. RESULTS The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. CONCLUSIONS Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice. (C) 2004 by the American College of Cardiology Foundation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Six Bos taurus (Hereford) steers (body weight 324 22 kg) were used in a 45-day study with a replicated 3 x 3 Latin-square design. Three treatments [ad libitum feeding (ADLIB); limit feeding, 85% of ad libitum (LIMIT); bunk management feeding where steers were only given access to feed from 1600 to 0800 hours the following day (BUNK)] were imposed over 3 periods, with 2 steers assigned to each treatment in each period. Cattle were managed in a temperature-controlled metabolism unit and were exposed to both thermoneutral (17.7degreesC-26.1degreesC) and hot (16.7degreesC-32.9degreesC) environmental conditions. By design, during the thermoneutral period, the ADLIB cattle displayed greater intake (P < 0.05) than the LIMIT group, with the BUNK group being intermediate. However, during the hot period, both the LIMIT and BUNK treatment groups increased feed intake 4-5%, whereas feed intake of the ADLIB treatment group declined nearly 2%. During both periods respiration rate (RR, breath/min) followed the same pattern that was observed for feed intake, with the greatest (P < 0.05) RR found in the ADLIB treatment group (81.09 and 109.55, thermoneutral and hot, respectively) and lowest (P < 0.05) RR in the LIMIT treatment group (74.47 and 102.76, thermoneutral and hot, respectively). Rectal temperature (RT) did not differ among treatments during the thermoneutral period or the first hot day, although during the thermoneutral period the ADLIB treatment group did tend to display a lower RT, possibly as a result of other physiological processes (pulse rate and RR) aiding to keep RT lower. During the hot period, differences in RT were found on Day 5, with the LIMIT cattle having lower (P < 0.10) RT (38.92degreesC) than the ADLIB (39.18degreesC) cattle, with BUNK cattle RT (39.14degreesC) being intermediate. However, when hourly data were examined, the ADLIB cattle had greater(P < 0.05) RT than the BUNK and LIMIT at 1800 hours and greater RT (P < 0.05) than the LIMIT group at 1400, 1500, and 1600 hours. Clearly, a change in diurnal RT pattern was obtained by using the LIMIT and BUNK feeding regimen. Both of these groups displayed a peak RT during the hot conditions, between 2100 and 2200 hours, whereas the ADLIB group displayed a peak RT between 1400 and 1500 hours, a time very close to when peak climatic stress occurs. Based on these results it is apparent that feedlot managers could alleviate the effects of adverse hot weather on cattle by utilising either a limit-feeding regimen or altering bunk management practices to prevent feed from being consumed several hours prior to the hottest portion of the day.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After ingestion of a standardized dose of ethanol, alcohol concentrations were assessed, over 3.5 hours from blood (six readings) and breath (10 readings) in a sample of 412 MZ and DZ twins who took part in an Alcohol Challenge Twin Study (ACTS). Nearly all participants were subsequently genotyped on two polymorphic SNPs in the ADH1B and ADH1C loci known to affect in vitro ADH activity. In the DZ pairs, 14 microsatellite markers covering a 20.5 cM region on chromosome 4 that includes the ADH gene family were assessed, Variation in the timed series of autocorrelated blood and breath alcohol readings was studied using a bivariate simplex design. The contribution of a quantitative trait locus (QTL) or QTL's linked to the ADH region was estimated via a mixture of likelihoods weighted by identity-by-descent probabilities. The effects of allelic substitution at the ADH1B and ADH1C loci were estimated in the means part of the model simultaneously with the effects sex and age. There was a major contribution to variance in alcohol metabolism due to a QTL which accounted for about 64% of the additive genetic covariation common to both blood and breath alcohol readings at the first time point. No effects of the ADH1B*47His or ADH1C*349Ile alleles on in vivo metabolism were observed, although these have been shown to have major effects in vitro. This implies that there is a major determinant of variation for in vivo alcohol metabolism in the ADH region that is not accounted for by these polymorphisms. Earlier analyses of these data suggested that alcohol metabolism is related to drinking behavior and imply that this QTL may be protective against alcohol dependence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Smoke inhalation injuries are the leading cause of mortality from burn injury. Airway obstruction due to mucus plugging and bronchoconstriction can cause severe ventilation inhomogeneity and worsen hypoxia. Studies describing changes of viscoelastic characteristics of the lung after smoke inhalation are missing. We present results of a new smoke inhalation device in sheep and describe pathophysiological changes after smoke exposure. Fifteen female Merino ewes were anesthetized and intubated. Baseline data using electrical impedance tomography and multiple-breath inert-gas washout were obtained by measuring ventilation distribution, functional residual capacity, lung clearance index, dynamic compliance, and stress index. Ten sheep were exposed to standardized cotton smoke insufflations and five sheep to sham smoke insufflations. Measured carboxyhemoglobin before inhalation was 3.87 +/- 0.28% and 5 min after smoke was 61.5 +/- 2.1%, range 50-69.4% ( P < 0.001). Two hours after smoke functional residual capacity decreased from 1,773 +/- 226 to 1,006 +/- 129 ml and lung clearance index increased from 10.4 +/- 0.4 to 14.2 +/- 0.9. Dynamic compliance decreased from 56.6 +/- 5.5 to 32.8 +/- 3.2 ml/ cmH(2)O. Stress index increased from 0.994 +/- 0.009 to 1.081 +/- 0.011 ( P < 0.01) ( all means +/- SE, P < 0.05). Electrical impedance tomography showed a shift of ventilation from the dependent to the independent lung after smoke exposure. No significant change was seen in the sham group. Smoke inhalation caused immediate onset in pulmonary dysfunction and significant ventilation inhomogeneity. The smoke inhalation device as presented may be useful for interventional studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The low-activity variant of the aldehyde dehydrogenase 2 (ALDH2) gene found in East Asian populations leads to the alcohol flush reaction and reduces alcohol consumption and risk of alcohol dependence (AD). We have tested whether other polymorphisms in the ALDH2 gene have similar effects in people of European ancestry. Methods: Serial measurements of blood and breath alcohol, subjective intoxication, body sway, skin temperature, blood pressure, and pulse were obtained in 412 twins who took part in an alcohol challenge study. Participants provided data on alcohol reactions, alcohol consumption, and symptoms related to AD at the time of the study and subsequently. Haplotypes based on 5 single-nucleotide polymorphisms (SNPs) were used in tests of the effects of variation in the ALDH2 gene on alcohol metabolism and alcohol's effects. Results: The typed SNPs were in strong linkage disequilibrium and 2 complementary haplotypes comprised 83% of those observed. Significant effects of ALDH2 haplotype were observed for breath alcohol concentration, with similar but smaller and nonsignificant effects on blood alcohol. Haplotype-related variation in responses to alcohol, and reported alcohol consumption, was small and not consistently in the direction predicted by the effects on alcohol concentrations. Conclusions: Genetic variation in ALDH2 affects alcohol metabolism in Europeans. However, the data do not support the hypothesis that this leads to effects on alcohol sensitivity, consumption, or risk of dependence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article examines the neurocognitive sequelae of repeated exposure to hypoxemia in apnea (breath-hold) divers. A brief review of the literature on the physiological and neurological adaptations involved in the human diving reflex is presented. The results from a neuropsychological investigation of N = 21 elite apnea divers are evaluated. Standard neuropsychological tests, with known sensitivity to mild brain insults, included speed of visuo-motor responding, speed of language comprehension, response inhibition, and visual and verbal attention and recall tasks. Results indicated that the breath-hold divers performed tasks within the average range compared to norms on all tests, suggesting that 1-20 years of repeated exposure to hypoxemia including multiple adverse neurological events did not impact on performance on standard neuropsychological tasks. The results are discussed in relation to implications for clinical conditions such as sleep apnea, respiratory disorders, altitude sickness, and recreational apnea activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sodium cyanide poison is potentially a more humane method to control wild dogs than sodium fluoroacetate (1080) poison. This study quantified the clinical signs and duration of cyanide toxicosis delivered by the M-44 ejector. The device delivered a nominal 0.88 g of sodium cyanide, which caused the animal to loose the menace reflex in a mean of 43 s, and the animal was assumed to have undergone cerebral hypoxia after the last visible breath. The mean time to cerebral hypoxia was 156 s for a vertical pull and 434 s for a side pull. The difference was possibly because some cyanide may be lost in a side Pull. There were three distinct phases of cyanide toxicosis: the initial phase was characterised by head shaking, panting and salivation; the immobilisation phase by incontinence, ataxia and loss of the righting reflex; and the cerebral hypoxia phase by a tetanic seizure. Clinical signs that were exhibited in more than one phase of cyanide toxicosis included retching, agonal breathing, vocalisation, vomiting, altered levels of ocular reflex, leg paddling, tonic muscular spasms, respiratory distress and muscle fasciculations of the muzzle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Alcohol contributes to about 30% of drowning fatalities associated with recreational aquatic activity and to 35% of drownings associated with boating. We consider regulatory and legislative strategies for preventing such deaths. Methods: We contacted water police in each Australian State and Territory to identify legislation creating alcohol-related offences for operators of recreational boats in their jurisdiction and to determine whether they conducted random breath testing (RBT). We also sought information from all 152 (81 urban and 71 rural) local government councils in NSW regarding restrictions on consumption of alcohol in public places within their shires. Results: Four Australian States (New South Wales, Queensland, Victoria and South Australia) have legislation prescribing maximum blood alcohol concentrations (BACs) for operators of recreational boats; all support this with RBT Western Australia, Tasmania and the Australian Capital Territory define more general offences for operating vessels while under the influence, of alcohol. Prohibitions or restrictions on consumption of alcohol in public places exist in 78 of the 86 shires in NSW that responded: 69 councils had alcohol-free zones, 53 restricted consumption of alcohol in public parks and reserves, and 33 had prohibitions or restrictions in some aquatic environments. Conclusions/implications: Legislation restricting BACs for recreational boat operators should be adopted in all Australian States and Territories. Optimal legislation would require that all occupants of recreational boats are required to comply with prescribed BAC levels, including when vessels are at anchor. Extension of by-laws prohibiting or restricting the consumption of alcohol specifically in aquatic environments warrants consideration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This Study evaluated the predictive validity of three previously published ActiGraph energy expenditure (EE) prediction equations developed for children and adolescents. Methods: A total of 45 healthy children and adolescents (mean age: 13.7 +/- 2.6 yr) completed four 5-min activity trials (normal walking. brisk walking, easy running, and fast running) in ail indoor exercise facility. During each trial, participants were all ActiGraph accelerometer oil the right hip. EE was monitored breath by breath using the Cosmed K4b(2) portable indirect calorimetry system. Differences and associations between measured and predicted EE were assessed using dependent t-tests and Pearson correlations, respectively. Classification accuracy was assessed using percent agreement, sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve, Results: None of the equations accurately predicted mean energy expenditure during each of the four activity trials. Each equation, however, accurately predicted mean EE in at least one activity trial. The Puyau equation accurately predicted EE during slow walking. The Trost equation accurately predicted EE during slow running. The Freedson equation accurately predicted EE during fast running. None of the three equations accurately predicted EE during brisk walking. The equations exhibited fair to excellent classification accuracy with respect to activity intensity. with the Trost equation exhibiting the highest classification accuracy and the Puyau equation exhibiting the lowest. Conclusions: These data suggest that the three accelerometer prediction equations do not accurately predict EE on a minute-by-minute basis in children and adolescents during overground walking and running. The equations maybe, however, for estimating participation in moderate and vigorous activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work has, as its objective, the development of non-invasive and low-cost systems for monitoring and automatic diagnosing specific neonatal diseases by means of the analysis of suitable video signals. We focus on monitoring infants potentially at risk of diseases characterized by the presence or absence of rhythmic movements of one or more body parts. Seizures and respiratory diseases are specifically considered, but the approach is general. Seizures are defined as sudden neurological and behavioural alterations. They are age-dependent phenomena and the most common sign of central nervous system dysfunction. Neonatal seizures have onset within the 28th day of life in newborns at term and within the 44th week of conceptional age in preterm infants. Their main causes are hypoxic-ischaemic encephalopathy, intracranial haemorrhage, and sepsis. Studies indicate an incidence rate of neonatal seizures of 0.2% live births, 1.1% for preterm neonates, and 1.3% for infants weighing less than 2500 g at birth. Neonatal seizures can be classified into four main categories: clonic, tonic, myoclonic, and subtle. Seizures in newborns have to be promptly and accurately recognized in order to establish timely treatments that could avoid an increase of the underlying brain damage. Respiratory diseases related to the occurrence of apnoea episodes may be caused by cerebrovascular events. Among the wide range of causes of apnoea, besides seizures, a relevant one is Congenital Central Hypoventilation Syndrome (CCHS) \cite{Healy}. With a reported prevalence of 1 in 200,000 live births, CCHS, formerly known as Ondine's curse, is a rare life-threatening disorder characterized by a failure of the automatic control of breathing, caused by mutations in a gene classified as PHOX2B. CCHS manifests itself, in the neonatal period, with episodes of cyanosis or apnoea, especially during quiet sleep. The reported mortality rates range from 8% to 38% of newborn with genetically confirmed CCHS. Nowadays, CCHS is considered a disorder of autonomic regulation, with related risk of sudden infant death syndrome (SIDS). Currently, the standard method of diagnosis, for both diseases, is based on polysomnography, a set of sensors such as ElectroEncephaloGram (EEG) sensors, ElectroMyoGraphy (EMG) sensors, ElectroCardioGraphy (ECG) sensors, elastic belt sensors, pulse-oximeter and nasal flow-meters. This monitoring system is very expensive, time-consuming, moderately invasive and requires particularly skilled medical personnel, not always available in a Neonatal Intensive Care Unit (NICU). Therefore, automatic, real-time and non-invasive monitoring equipments able to reliably recognize these diseases would be of significant value in the NICU. A very appealing monitoring tool to automatically detect neonatal seizures or breathing disorders may be based on acquiring, through a network of sensors, e.g., a set of video cameras, the movements of the newborn's body (e.g., limbs, chest) and properly processing the relevant signals. An automatic multi-sensor system could be used to permanently monitor every patient in the NICU or specific patients at home. Furthermore, a wire-free technique may be more user-friendly and highly desirable when used with infants, in particular with newborns. This work has focused on a reliable method to estimate the periodicity in pathological movements based on the use of the Maximum Likelihood (ML) criterion. In particular, average differential luminance signals from multiple Red, Green and Blue (RGB) cameras or depth-sensor devices are extracted and the presence or absence of a significant periodicity is analysed in order to detect possible pathological conditions. The efficacy of this monitoring system has been measured on the basis of video recordings provided by the Department of Neurosciences of the University of Parma. Concerning clonic seizures, a kinematic analysis was performed to establish a relationship between neonatal seizures and human inborn pattern of quadrupedal locomotion. Moreover, we have decided to realize simulators able to replicate the symptomatic movements characteristic of the diseases under consideration. The reasons is, essentially, the opportunity to have, at any time, a 'subject' on which to test the continuously evolving detection algorithms. Finally, we have developed a smartphone App, called 'Smartphone based contactless epilepsy detector' (SmartCED), able to detect neonatal clonic seizures and warn the user about the occurrence in real-time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o tamanho do espaço aéreo naso e bucofaríngeo em indivíduos com má oclusão Classe II, divisão 1 de Angle. A metodologia constou da mensuração do espaço aéreo naso e bucofaríngeo em 122 telerradiografias laterais de indivíduos na faixa etária dos 12 aos 21 anos, brasileiros leucodermas. Desses indivíduos, 62 apresentavam respiração nasal e 60 respiração bucal, não sendo submetidos a tratamento ortodôntico prévio. Os resultados demonstraram a ausência de dimorfimo sexual; os indivíduos respiradores nasais apresentaram maiores dimensões dos limites superior e inferior e da menor secção transversal do espaço aéreo quando comparado aos respiradores bucais. O tamanho médio da adenóide foi maior nos pacientes respiradores bucais. Quando comparamos as variáveis estudadas com os padrões faciais não foram observadas diferenças entre os mesmos, porém quando associamos padrão facial com o tipo de respiração foi encontrada maior proporção de indivíduos respiradores bucais nos padrões dolicofacial e mesofacial em relação ao padrão braquifacial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O propósito neste estudo foi determinar a posição de repouso da língua em indivíduos com oclusão dentária normal e respiração nasal, por meio de telerradiografias em norma lateral realizadas após a ingestão de bário. A amostra foi composta por 66 radiografias de indivíduos brancos com oclusão dentária normal, sendo 26 do sexo masculino e 40 do sexo feminino, na faixa etária de 12 a 21 anos de idade, procedentes de escolas da região do Grande ABC Paulista. O critério utilizado para diagnóstico da oclusão normal foi As Seis Chaves para a Oclusão Normal preconizadas por Andrews (1972), devendo estar presentes no mínimo quatro das seis chaves, sendo obrigatória a presença da primeira chave de oclusão que é a da relação interarcos. As radiografias foram obtidas com o indivíduo em posição natural da cabeça após a ingestão de contraste de sulfato de bário para evidenciar o controle da língua. Posteriormente foi feito o desenho anatômico das estruturas pesquisadas, marcados os pontos cefalométricos, traçadas as linhas e os planos, e por último obtidas as seguintes medidas lineares: comprimento e altura da língua, distância do dorso da língua na sua porção média até o palato duro e a distância entre a ponta da língua e a incisal do incisivo inferior. Por meio dos resultados encontrados verificou-se que não existe um padrão único de posicionamento de repouso da língua dentro da cavidade oral, em pacientes respiradores nasais, variando muito sua distância até a incisal dos incisivos inferiores, bem como até o palato duro, havendo uniformidade apenas no fato da língua tocar o palato mole em todos os indivíduos da amostra. Não houve relação estatisticamente significante entre a posição de repouso da língua e os biotipos faciais e nem dimorfismo sexual.